Honeywell AQ2000 Series Installation Guide

0 (0)
Honeywell AQ2000 Series Installation Guide

AQ2000 Series

AQUATROL THERMOSTAT WIRING

INSTALLATION INSTRUCTIONS

Aquatrol zoning modules are compatible with any digital thermostat. The AQ1000 digital communicating thermostats have been designed to enhance the Aquatrol system functionalities. Non-communicating dry-contact thermostats provide the needed heat signals for operation.

 

 

 

 

AQ1000TN2 and AQ1000TP2

Battery-powered/

 

24-VAC Thermostats

Dry-contact Thermostats

 

 

 

 

 

 

 

 

 

Connect TH terminals of the thermostat

Connect Rh and W terminals of the

1.

If any, remove jumper between Rc

to Rh and W terminals of the zone

thermostat to Rh and W terminals of

 

and R on thermostat.

module (no polarity to observe).

the zone module.

2.

Connect 24 VAC from transformer to

 

 

 

C and Rc terminals of thermostat.

 

 

3.

Connect Rh and W terminals of the

 

 

 

thermostat to Rh and W terminals of

 

 

 

the zone module.

 

 

 

 

Aquatrol zoning modules are compatible with any digital thermostat. The AS1000 digital communicating thermostats have been The AQ panels are equipped with a 38 VA transformer which leaves between 27 and 34 VA available (depending on the panel model) to power thermostats or valves. Honeywell's VisionPRO, FocusPRO and PRO thermostat lines draw less than 0.5 VA for each thermostat. Honeywell's Prestige HD thermostat draws 2.7 VA each under normal usage. If additional VA is needed for the system, use a second transformer.

69-2394—02