Flowserve ARG User Manual

4 (1)
User Instructions ARG Series Standard Actuator - ACENIM0123-00 12/12
®
ARG Series Standard Actuator
USER INSTRUCTIONS
Sandwich Gearbox Override Hydraulic Override
FCD ACENIM0123-00 12/12
Installation
Operation
Maintenance
Experience In Motion
Worchester Controls
1
User Instructions ARG Series Standard Actuator - ACENIM0123-00 12/12
STOP!
®
INDEX
1 Using Flowserve valves, actuators and acces-
sories correctly
2 Jackscrew Override
2.2 Install jackscrew override onto heavy duty DA actuator
2.3 install jackscrew override onto existing heavy duty SR actuator
2.4 Operation –Jackscrew Override
2.5 Automatic Operation
3 Gear Override
3.2 Retrofit Gear Override onto Existing ARG Ac­tuator Installation
3.3 Mount a Preassembled Actuator
3.4 Operation
3.5 Restoring Automatic Operation
4 Hydraulic Override
4.2 Install hydraulic override onto existing heavy duty Spring Return actuator
4.3 Operation –SR Override
4.4 Install hydraulic override on Standard DA heavy duty actuator
4.5 Operation –DA Override
1 Using Flowserve Valves, Actuators and Acces-
sories Correctly
1.1 General usage
The following instructions are designed to assist in
unpacking, installing and performing maintenance as required on FLOWSERVE products. Product us­ers and maintenance personnel should thoroughly review this bulletin prior to installing, operating or performing any maintenance.
In most cases FLOWSERVE valves, actuators and
accessories are designed for specific applications with regard to medium, pressure and temperature. For this reason they should not be used in other ap­plications without first contacting the manufacturer.
1.2 Terms concerning safety
The safety terms DANGER, WARNING, CAUTION
and NOTE are used in these instructions to highlight particular dangers and/or to provide additional infor­mation on aspects that may not be readily apparent.
DANGER: indicates that death, severe personal injury
and/or substantial property damage will occur if proper precautions are not taken.
WARNING: indicates that death, severe personal
injury and/or substantial property damage can occur if proper precautions are not taken.
CAUTION: indicates that minor personal injury and/
or property damage can occur if proper precautions are not taken.
NOTE: indicates and provides additional technical
information, which may not be very obvious even to qualified personnel.
Compliance with other, not particularly emphasised
notes, with regard to transport, assembly, operation and maintenance and with regard to technical docu­mentation (e.g. in the operating instruction, product documentation or on the product itself) is essential, in order to avoid faults, which in themselves might directly or indirectly cause severe personal injury or property damage.
1.3 Protective clothing
FLOWSERVE products are often used in problematic
applications (e.g. extremely high pressures, danger­ous, toxic or corrosive mediums). In particular valves with bellows seals point to such applications. When performing service, inspection or repair operations always ensure, that the valve and actuator are depres­surised and that the valve has been cleaned and is free from harmful substances. In such cases pay particular attention to personal protection (protective clothing, gloves, glasses etc.).
1.4 Qualified personnel
Qualified personnel are people who, on account of their
training, experience and instruction and their knowl­edge of relevant standards, specifications, accident prevention regulations and operating conditions, have been authorised by those responsible for the safety of the plant to perform the necessary work and who can recognise and avoid possible dangers.
2
User Instructions ARG Series Standard Actuator - ACENIM0123-00 12/12
STOP!
®
1.5 Installation
DANGER: Before installation check the order-no.,
serial-no. and/or the tag-no. to ensure that the valve/ actuator is correct for the intended application.
Do not insulate extensions that are provided for hot
or cold services.
Pipelines must be correctly aligned to ensure that the
valve is not fitted under tension.
Fire protection must be provided by the user.
1.6 Spare parts
Use on l y FLOWS E R V E origin a l spare parts.
FLOWSERVE cannot accept responsibility for any damages that occur from using spare parts or fasten­ing materials from other manufactures. If FLOWSERVE products (especially sealing materials) have been on store for longer periods check these for corrosion or deterioration before using these products. Fire protec­tion for FLOWSERVE products must be provided by the end user.
1.7 Service / repair
To avoid possible injury to personnel or damage to
products, safety terms must be strictly adhered to. Modifying this product, substituting nonfactory parts, or using maintenance procedures other than outlined in this instruction could drastically affect performance and be hazardous to personnel and equipment, and may void existing warranties. Between actuator and valve there are moving parts. To avoid injury FLOWSERVE provides pinch-point-protection in the form of cover plates, especially where side-mounted positioners are fitted. If these plates are removed for inspection, service or repair special attention is required. After completing work the cover plates must be refitted.
1.8 Storage
In most cases FLOWSERVE products are manufactured
from stainless steel. Products not manufactured from stainless steel are provided with an epoxy resin coating. This means that FLOWSERVE products are well protected from corrosion. Nevertheless FLOWSERVE products must be stored adequately in a clean, dry environment. Plastic caps are fitted to protect the flange faces to prevent the ingress of foreign materials. These caps should not be removed until the valve is actually mounted into the system.
1.9 Valve and actuator variations
These instructions cannot claim to cover all details of
all possible product variations, nor can they provide information for every possible example of installation, operation or maintenance. This means that the instructions normally include only the directions to be followed by qualified personal where the product is being used for is defined purpose. If there are any uncertainties in this respect particularly in the event of missing product-related information, clarification must be obtained via the appropriate FLOWSERVE sales office.
1.10 Unpacking
Each delivery includes a packing slip. When unpacking,
check all delivered valves and accessories using this packing slip.
Report transport damage to the carrier immediately.
In case of discrepancies, contact your nearest
FLOWSERVE location.
Apart from the operating instructions and the
obligatory accident prevention directives valid in the country of use, all recognised regulations for safety and good engineering practices must be followed.
WARNING: Before produ c ts ar e re t urned to
FLOWSERVE for repair or service FLOWSERVE must be provided with a certificate which confirms that the product has been decontaminated and is clean. FLOWSERVE will not accept deliveries if a certificate has not been provided (a form can be obtained from FLOWSERVE).
3
User Instructions ARG Series Standard Actuator - ACENIM0123-00 12/12
®
2 Heavy Duty Jackscrew Overrides
Jackscrew overrides on Worchester Controls heavy duty ac­tuators provide economical, durable method for manually operating the actuator. The jackscrews are either direct oper­ating or bevel gearbox driven, to reduce operation effort. The direct operation consists of a rotating screw, threading into the nut which is fitted on the Torque module/ Spring module, and the hand wheel directly turns the screw.
The bevel gearbox driven jackscrew, has an arrangement of rotating nut and a rising screw. The higher thrust require­ments for models bigger than 4000 Nm and for the stiffer springs are met with this type of jackscrew design.
Jackscrews are available on models ARG1 through ARG5.
2.1 Installation
worchester Controls standard jackscrew overrides are pro­vided as a complete integral component of the heavy duty actuator. Override units are shipped with the jackscrew as­sembly mounted to the actuator and vent valves installed on the pressure module. No additional customer installation is required. Refer Worchester Controls Heavy Duty IOM (FCD AXENIM0121) for instructions on installing Heavy Duty ac­tuator into service.
end flange, locating the spigot in the Torque module.
2.2.4 Use the jackscrew mounting kit and the O-ring from the DA cover.
2.2.5 Tighten the mounting stud nuts fully, with lock wash­ers from the kit.
2.2.6 Fix the 3 way vent valves supplied in the kit, to both ports of the pressure module and connect air supply pressure lines to these valves.
2.2.7 Installation of pressure module side jackscrew re­quires replacement of std end plate of the pressure module. Remove tie rod nuts and end plate, and fit in the jackscrew assembly, supplied preassembled with the suitable thrust base End Plate. Tighten the tie rod nuts back on the pressure module. Fix the 3way valve on the ports.
2.3 Install jackscrew override onto existing heavy duty SR actuator (see Fig.: 2)
2.3.1 Disconnect air pressure and electrical power from ac­tuator.
2.2 Install jackscrew override onto heavy duty DA actuator (see Fig.: 1)
2.2.1 Disconnect air pressure and electrical power from ac­tuator.
2.2.2 Remove the DA end cover plate.
2.2.3 Back off the jackscrew fully in the assembly and mount the jackscrew assembly on the torque module
2.3.2 Remove the end cover plate on the Spring module, re­taining the cover O-ring.
2.3.3 Tighten the mounting studs from the mounting kit with thread lock compound into the spring module end plate.
2.3.4 Back off the jackscrew fully in the assembly and mount the jackscrew assembly on the spring module end plate’s thrust base, locating the spigot in the spring
4
Fig.: 1 Install Jackscrew Override (DA)
Loading...