Flowserve APS2 User Manual

0 (0)
Flowserve APS2 User Manual

Automax Valve Automation Systems

Installation, Operation and Maintenance Instructions

Flowserve Corporation

765 South 100 East

Phone: 801 373 3028

Flow Control Division

Provo, Utah 84606-6160

Facsimile: 801 489 2228

Automation Business Unit

www.flowserve.com

Email: actuators@flowserve.com

 

 

 

APS2 Module

Installation Instructions

The Automax APS2 may be installed very easily to any SuperNova series spring return actuator, with the hardware supplied with the module.

1.Place each o-ring provided into the o-ring bore on the rear of the module (the side with two large ports.) Each o-ring should be completely seated in the bore.

2.Place the actuator with the two ports facing you, and the stem pointing up. Orient the APS2 module with the o-rings toward the actuator, and the breather vent facing left.

3.The module will be mounted to the actuator, using the two diagonal tapped holes next to the ports. Align these holes with C-bored through holes of the module, and mount with screws provided.

Directional valves may be line mounted to the APS2 by connecting the appropriate valve port to the 1/4" NPT supply port on the front of the APS2. In addition, the module supports the NAMUR mounting standard. In this case, the directional valve should be positioned such that the correct port is covering the APS2 supply. Tapped holes are provided for NAMUR mounting.

Two o-rings are required for this arrangement (2mm x 16mm o-ring size).

SuperNova

Operation

The Automax APS2 module works with remote line mounted solenoid valves and diverts exhaust air from between the pistons into the spring chamber. This prevents corrosive atmosphere from being pulled into the spring chamber.

Note: The APS2 can not be used in conjunction with a positioner.

Temperature: -20° F to 180° F

Pressure: 20psig to 100psig

Media: Dry or lubricated non-corrosive gas compatible with nitrile and silicone seals.

Exhaust: C = 0.8 (Spring Return Stroke)

Inlet: C = 1.2 (Pressure Stroke)

Actuator Pressurized

Pressure at supply port presses edge of diaphragm to ring, allowing air flow around and under ring. Air flows into piston port of actuator, compressing springs. Spring side air exhausts out vent to atmosphere.

1/4" NPT

Upper Housing

Supply Port

with NAMUR Mounting

 

Diaphragm

 

Lower

 

 

 

 

Housing

Piston

Spring

Breather

APS2

 

 

Port

Vent

 

Port

 

 

 

 

Actuator Exhausted

Supply pressure is released and springs push on piston to force air out piston port. Pressure forces diaphragm up, covering supply port and revealing spring port. Air flows into spring port, allowing clean air in instead of contaminated air from the environment.

NAMUR Mounting Pattern

1/4" NPT

Supply

 

LMR0016-0

(AUTO-16)

11/01

Page 1 of 2

© 2001, Flowserve Corporation, Provo, Utah