Data Sheet
Marine Solenoid Coils
Type BR
Danfoss solenoid valves and coils are usually ordered separately to allow maximum €exibility, enabling you to select a valve and coil combination to best suit your needs.
The Danfoss marine coil program consists of easy-to-handle Clip-On system.
Danfoss Marine coils are designed according to marine requirements. The insulation material burning behavior is V-0 class, Glow Wire Flammability Index (GWFI) 960°C and Glow Wire Ignition Temperature (GWIT) 750°C according to IEC60695.
Features and versions
• Designed for:
◦ Marine applications
◦ For 13,5 mm B systems
◦ EV210B, EV220B, EV224B, EV250B, EVR, EVRA, EVRS, EVRAT, EVRST and EVM Solenoid valves.
• Encapsulated coils with long operating life, even under extreme conditions
• Coils can be ƒtted without use of tools
• Coils can only be removed with use of tools
• Marine coils for AC: ◦ 24V 50/60 Hz
◦ 110-120V 50/60 Hz ◦ 230V 50/60Hz
• Marine coils for DC: ◦ 24V
• Marine coils available with: ◦ Cable plugs IP65 or IP67
AI353443381491en-000201
Marine Solenoid Coils, type BR
Product speci€cation
Coil identi€cation
Figure 1: Coil identi€cation
1 |
|
MADE IN DENMARK |
|
|
||
|
|
Type BR230CS |
|
2 |
||
|
Spare part no. |
018F4720 |
3 |
|||
|
Tambient |
-40T50 °C |
4 |
|||
5 |
230V |
60Hz |
13W |
24VA |
8 |
|
|
230V |
50Hz |
16W |
31VA |
||
6 |
7 |
|||||
|
|
|
|
|||
|
|
|
|
|
||
9 |
|
|
F4620 |
10 |
||
11 |
|
|
||||
Danfoss A/S, 6430 Nordborg, Denmark |
|
1Country of origin
2Coil type
3Spare part no. (code no.)
4Ambient temperature (-40 – 50 °C = Ambient temperature range: -40 °C – 50 °C)
5Supply voltage [V]
6Frequency [Hz]
7Power consumption [W]
8Power consumption [VA]
9CE marking
10Raw coil number (F4620=Raw coil number 018F4620)
11Point of contact
BR marine coils, High performance coils
Figure 2: BR marine coils
features
•Enclosure: Up to IP67 / NEMA 4X
•In accordance with:
© Danfoss | Climate Solutions | 2021.08 |
AI353443381491en-000201 | 2 |
Marine Solenoid Coils, type BR
◦RoHS Directive 2011/65/EU
◦Low Voltage Directive 2014/35/EU
▪EN60730-1
▪EN60730-2-8
▪VDE
▪CSA
•Design according to:
◦Flammability
▪UL94 V0
▪IEC 60695-11-5
Table 1: BR, High performance coils
Type |
Tambient |
Supply voltage |
Voltage variation |
Frequency |
Power consumption |
Code no. |
||
[°C] |
[V] |
[Hz] |
[W] |
[VA] |
||||
|
|
|
||||||
BR024CS |
-40 – 50 |
24 |
±10% |
50 |
14 |
26 |
018F4722 |
|
24 |
±10% |
60 |
12 |
21 |
||||
|
|
|
||||||
BR120CS |
-40 – 50 |
110 |
±10% |
50 |
14 |
27 |
018F4723 |
|
110 – 120 |
±10% |
60 |
14 |
27 |
||||
|
|
|
||||||
|
|
|
±10% |
50 |
16 |
31 |
|
|
BR230CS |
-40 – 50 |
220 - 230 |
018F4720 |
|||||
±10% |
60 |
13 |
24 |
|||||
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
BR024DS |
-40 – 50 |
24 |
±10% |
DC |
16 |
|
018F4721 |
|
|
|
|
|
|
|
|
|
NOTE:
See pages 4 - 5 for MOPD table when ordering coil to speciƒc valve type.
Technical data
Table 2: Technical data
Design |
In accordance with VDE 0580 |
Insulation of coil windings |
Insulation Class H (180 °C) |
Connection |
Spade connector in accordance with DIN 43650 form A |
Flammability GWFI/GWIT |
960 °C / 750 °C |
UL recognition |
UL94 |
Burning behavior |
V-0 class |
Enclosure, IEC 60529 |
Up to IP67 / NEMA 4X |
Plug type IP65 |
Cable plug (042N1278) |
Plug type IP67 |
Cable plug (042N1256) |
|
|
MOPD table for EV solenoid valves
Table 3: MOPD table for EV solenoid valves
|
|
|
|
|
Solenoid marine coils |
|
|
|
Valve type |
Ori€ce size |
|
BR024CS |
|
BR120CS |
|
BR230CS |
BR024DS |
|
(018F4722) |
|
(018F4723) |
|
(018F4720) |
(018F4721) |
||
|
|
|
|
|
||||
|
|
50 Hz |
60 Hz |
50 Hz |
60 Hz |
50 Hz |
60 Hz |
DC |
|
50 15-25 NC |
16 (1) / 10 (2) |
|
16 (1)/ 10 (2) |
|
16 (1)/ 10 |
16 (1)/ 10 |
|
EV220B 15-50 |
32-50 NC |
12 (1)/ 10 (2) |
|
12 (1)/ 10 (2) |
|
12 (1)/ 10 (2) |
12 (1)/ 10 (2) |
|
|
15-50 NO |
10 |
|
10 |
|
10 |
10 |
|
|
6 NC |
20 |
|
20 |
|
20 |
10 |
|
|
6 NO |
10 |
|
10 |
|
10 |
10 |
|
EV220B 6-12 |
10 NC |
20 |
|
20 |
|
20 |
20 |
|
|
10 NO |
10 |
|
10 |
|
10 |
10 |
|
|
12 NC |
10 |
|
10 |
|
10 |
|
|
EV250B |
12 NC |
10 |
|
10 |
|
10 |
6 |
|
12 NO |
10 |
|
10 |
|
10 |
10 |
||
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
1.5 |
|
30 |
|
30 |
|
30 |
30 |
|
2 |
|
30 |
|
30 |
|
30 |
30 |
EV210B 1,5-10 |
3 |
|
20 |
|
20 |
|
20 |
13 |
|
6 |
|
4 |
|
4 |
|
4 |
2 |
|
10 |
|
1.2 |
|
1.2 |
|
1.2 |
0.6 |
|
|
|
|
|
|
|
|
|
© Danfoss | Climate Solutions | 2021.08 |
AI353443381491en-000201 | 3 |