Danfoss D1P 65, D1P 130, D1P 145, D1P 193, D1P 260 Data sheet

0 (0)
Danfoss D1P 65, D1P 130, D1P 145, D1P 193, D1P 260 Data sheet

Data Sheet

D1 High Power Open Circuit Pumps

65/130/145/193/260 cm³

The new D1 pump is a high-pressure, highperformance variable axial piston pump, developed specifically for open-circuit systems in the most extreme application environments. Its robust design makes it an ideal solution for concrete machinery, mining machinery, cranes, drilling machinery, offshore, marine, and oil and gas equipment.

The D1 expands the Danfoss open circuit pump portfolio to include higher hydraulic power product options for customers. It’s designed to work seamlessly with the new PVG 128/256 high flow valves, providing OEMs a full hydraulic system portfolio.

The D1 pump is offered with five displacement options (65cc-260cc), a wide range of control options (pressure, load sense, power limiting and displacement controls), output pressure up to 350bar [5000psi] continuously, 400bar [5802psi] intermittently, and an integral charge pump allows the D1 pump to run at speeds up to 2500rpm.

The D1 pump was developed and designed with global expertise, and customers will benefit from the strong local service provided by Danfoss. Danfoss offers technical support through its wide network of local distributors in more than 100 countries.

Features

Proven and optimized 9 piston rotating group

Angled bore cylinderblock design improves self-priming capability

The spherical valve plate and cylinderblock surface provide stable rotation, thus achieving high efficiency

Mainstream installation

Standardized connector interface

High power density

Integral charge pump option allows the pump to run at higher speed

PLUS+1® compliant control

Full power through drive capability

The electric displacement control features manual override function for diagnosis

Control options

NPE0: PC + EDC (without pilot pressure)

NPE2: PC + EDC (with pilot pressure)

NPNN: PC

NPSN: PC + LS

NPNR: PC + RPC

NNES: EDC + LS

TPSN: MTC + PC + LS

TPE2/TPE5: MTC + PC + EDC

© Danfoss | October 2020

AI152986485542en-CN0303 | 1

Data Sheet

D1 High Power Open Circuit Pumps

Technical Specifications

 

 

 

65

130

145

193

260

Features

Unit

W/O Charge

W/O Charge

W/ Charge

W/O Charge

W/ Charge

W/Charge

W/Charge

 

 

 

Pump

Pump

Pump

Pump

Pump

Pump

Pump

Displacement

 

cm3 [in3]

65 [3.84]

130 [7.93]

130 [7.93]

145 [8.85]

145 [8.85]

193 [11.78]

260 [15.87]

Available Rotation1

CCW [L]

 

 

 

 

 

 

 

 

 

CW [R]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight (approx.)

kg [lbs]

47 [104]

68 [150]

74 [163]

68 [150]

74 [163]

106 [234]

141 [311]

 

 

 

 

 

 

 

 

 

 

 

Min.

 

500

500

500

500

500

500

500

 

 

 

 

 

 

 

 

 

 

Input Speed

Rated

rpm

2550

2200

2500

2200

2500

2500

2300

 

 

 

 

 

 

 

 

 

 

 

Max.

 

3000

2500

2500

2200

2500

2500

2300

 

 

 

 

 

 

 

 

 

 

Theoretical Flow

l/min

165 [44]

286 [76]

325 [86]

319 [84]

363 [96]

483 [128]

598 [158]

 

 

[US gal/min]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max.

 

 

 

 

 

 

 

 

System

Working

 

 

 

 

350 [5076]

 

 

 

Pressure2

bar [psi]

 

 

 

 

 

 

 

Pressure

 

 

 

 

 

 

 

Max.

 

 

 

 

400 [5802]

 

 

 

 

 

 

 

 

 

 

 

 

Pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inlet Pressure

Min.

bar [psi]

0.8 [11.6]

0.8 [11.6]

0.6 [8.7]

0.8 [11.6]

0.6 [8.7]

0.6 [8.7]

0.6 [8.7]

(Abs)

 

 

 

 

 

 

 

 

Max.

30 [435]

30 [435]

2 [29]

30 [435]

2 [29]

2 [29]

2 [29]

 

 

 

 

 

 

 

 

 

 

 

Case

 

 

 

 

 

 

 

 

 

Pressure

Max.

bar [psi]

 

 

 

2 [29]

 

 

 

(Abs)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1Rotation: Counterclockwise (CCW) & Clockwise (CW) directions as viewed from the shaft end of the pump.

2Applied pressures above maximum working pressure requires Danfoss application approval. Maximum (peak) pressure is the highest intermittent (t<1s) outlet pressure allowed.

2 | © Danfoss | October 2020

AI152986485542en-CN0303

Loading...