Honeywell TH6220D, TH6320U User Manual

0 (0)

Installation

Guide

FocusPRO® TH6000 Series

Programmable Thermostat

This manual covers the following models

TH6110D: For 1 Heat/1 Cool systems

TH6220D: For up to 2 Heat/2 Cool systems

TH6320U: For up to 3 Heat/2 Cool systems

(Remove battery holder to find model number)

System Types

Gas, oil, or electric heat with air conditioning

Warm air, hot water, highefficiency furnaces, heat pumps, steam, gravity

Heat only — two-wire systems, three-wire zone valves (Series

20), and normally open zone valves

Heat only with fan

Cool only

750 mV heating systems

Must be installed by a trained, experienced technician

Read these instructions carefully. Failure to follow these instructions can damage the product or cause a hazardous condition.

Need Help?

For assistance with this product please visit http://customer.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502

® U.S. Registered Trademark. Patents pending.

 

Copyright © 2009 Honeywell International Inc.

 

All rights reserved.

69-1920EFS-01

Installation Guide

Wallplate installation

1.Separate wallplate from thermostat.

2.Mount wallplate as shown below.

Remove battery holder.

Pull here to remove wallplate from new thermostat.

It's easier to grasp the wallplate and remove it after completely removing the battery holder.

Insert reference card after wallplate is mounted (see instructions, below).

M29433

Drill 3/16" holes for drywall. Drill 7/32" holes for plaster.

Mounting screws

Wire hole

Wall anchors

ENGLISH

Wallplate

MCR29435

CAUTION: ELECTRICAL HAZARD

Can cause electrical shock or equipment damage. Disconnect power before beginning installation.

MERCURY NOTICE

If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. Contact your local waste management authority for instructions regarding recycling and proper disposal.

69-1920EFS—01

2

FocusPRO® TH6000 Series

Power options

Keep wires in this shaded area

Remove factoryinstalled jumper only for twotransformer systems.

Insert batteries for primary or backup power.

MCR29436

Connect C for primary AC power (optional if batteries are installed).

Wiring

Terminal designations

Shaded areas below apply only to TH6320U/TH6220D or as otherwise noted.

Conventional Terminals:

Heat Pump Terminals:

Rc

24VAC power from cooling

Rc

24VAC power from cooling

 

transformer

 

 

 

transformer

 

R

24VAC power from heating

R

24VAC power from heating

 

transformer

 

 

 

transformer

 

W

Heat relay (stage 1)

O/B

Changeover valve

W2

Heat relay (stage 2)

Y

Compressor contactor (stage 1)

Y

Compressor contactor (stage 1)

Y2

Compressor contactor (stage 2)

Y2

Compressor contactor (stage 2)

 

-TH6320U only

 

 

 

G

Fan relay

 

 

 

G

Fan relay

 

 

 

 

 

 

 

C

24VAC common. For 2 transformer

Aux

Auxiliary heat relay*

 

 

 

 

systems, use common wire from cooling

E

Emergency heat relay*

 

transformer.

 

 

L

Sends output when set to Em. Heat

 

 

 

 

 

 

 

 

 

 

 

 

C

24VAC common

TH6110D

 

 

 

 

TH6110D

 

G W C Y R Rc

 

 

G

C Y R Rc

 

TH6220D

 

 

 

 

TH6220D

 

 

Y2 W2 G

W

C

Y

R Rc

 

 

 

TH6320U

 

 

 

 

TH6320U

 

 

Y2 W2 G

W

C

Y

R Rc

 

E

 

 

 

 

 

 

MCR29437

 

MCR29438

 

 

 

 

 

 

*Aux and E terminals combined on TH6320U only.

ENGLISH

3

69-1920EFS—01

Installation Guide

Wiring

Wiring guide — conventional systems

Shaded areas below apply only to TH6320U/TH6220D or as otherwise noted.

1H/1C System

 

 

(1 transformer)

G W C Y R Rc

Rc

Power [1]

 

MCR29439

R

[R+Rc joined by jumper]

 

Y

Compressor contactor

 

C

24VAC common [3]

 

 

W

Heat relay

 

 

G

Fan relay

 

 

Heat-only System

Rc

Power [1]

W C

R Rc

R

[R+Rc joined by jumper]

MCR29440

 

 

 

C

24VAC common [3]

 

 

 

W

Heat relay

 

 

 

Heat-only System

 

 

(Series 20) [5]

W C Y R Rc

Rc

[R+Rc joined by jumper]

MCR29441

 

R

Series 20 valve terminal “R” [1]

 

Y

Series 20 valve terminal “W”

 

C

24VAC common [3]

 

 

W

Series 20 valve terminal “B”

 

Heat-only System

(normally open zone valve) [5]

C Y R Rc

 

Rc

[R+Rc joined by jumper]

MCR29442

 

 

 

 

R

Power [1]

 

 

 

Y

Normally open zone valve

 

 

 

C

24VAC common [3]

 

 

 

1H/1C System

G W C Y R Rc

 

(2 transformers)

 

 

M29443

 

 

 

 

 

Rc

Power (cooling transformer) [1, 2]

ENGLISH

R

Power (heating transformer) [1, 2]

W

Heat relay

 

 

 

Y

Compressor contactor

 

 

C

24VAC common [3, 4]

 

 

G

Fan relay

 

 

NOTES

Wire specifications:

Use 18to 22-gauge thermostat wire. Shielded cable is not required.

[1]Power supply. Provide disconnect means and overload protection as required.

[2]Remove jumper for 2-transformer systems.

[3]Optional 24VAC common connection.

[4]Common connection must come from cooling transformer.

[5]In Installer Setup, set system type to Heat Only.

[6]In Installer Setup, set system type to

2Heat/2Cool Conventional.

Heat-only System

 

 

 

 

with Fan

 

G W

C

 

R Rc

Rc

Power [1]

 

 

 

MCR29444

R

[R+Rc joined by jumper]

 

 

 

C

24VAC common [3]

 

 

 

W

Heat relay

 

 

 

 

G

Fan relay

 

 

 

 

Cool-only System

 

 

 

 

Rc

Power [1]

G

C

Y

R Rc

R

[R+Rc joined by jumper]

 

MCR29445

 

 

 

Y

Compressor contactor

 

 

 

C

24VAC common [3]

 

 

 

G

Fan relay

 

 

 

 

2H/2C System

 

 

 

 

(1 transformer) [6]

Y2 W2 G W

C

Y

R Rc

Rc

Power [1]

 

 

MCR29446

R

[R+Rc joined by jumper]

 

 

 

Y

Compressor contactor (stage 1)

 

C

24VAC common [3]

 

 

 

W

Heat relay (stage 1)

 

 

 

G

Fan relay

 

 

 

 

W2

Heat relay (stage 2)

 

 

 

Y2

Compressor contactor (stage 2)

 

2H/2C System

 

 

 

 

(2 transformers) [6]

Y2 W2 G W

C

Y

R Rc

Rc

Power (cooling transformer) [1, 2]M29447

R

Power (heating transformer) [1, 2]

Y

Compressor contactor (stage 1)

 

C

24VAC common [3, 4]

 

 

 

W

Heat relay (stage 1)

 

 

 

G

Fan relay

 

 

 

 

W2

Heat relay (stage 2)

 

 

 

Y2

Compressor contactor (stage 2)

 

See [notes] below

[7]In Installer Setup, set changeover valve to O or B.

[8]In Installer Setup, set system type to

2Heat/1Cool Heat Pump.

[9]In Installer Setup, set system type to

2Heat/2Cool Heat Pump.

[10]In Installer Setup, set system type to 3Heat/2Cool Heat Pump.

[11]L terminal sends a continuous output when thermostat is set to Em. Heat. Connect to Honeywell zoning panels to switch the panel to Emergency Heat.

[12]Install field jumper between Aux and E if there is no emergency heat relay.

69-1920EFS—01

4

Honeywell TH6220D, TH6320U User Manual

FocusPRO® TH6000 Series

Wiring

Wiring guide — heat pump systems

Shaded areas below apply only to TH6320U/TH6220D or as otherwise noted.

1H/1C Heat

2H/2C Heat

 

Pump System

Pump System

 

Rc

Power [1]

MCR29448 (TH6320U only) [9]

MCR29451

R

[R+Rc joined by jumper]

Rc

Power [1]

 

Y

Compressor contactor

R

[R+Rc joined by jumper]

 

C

24VAC common [3]

Y

Compressor contactor (stage 1)

O/B

Changeover valve [7]

C

24 VAC common [3]

 

G

Fan relay

O/B

Changeover valve [7]

 

 

 

G

Fan relay

 

2H/1C Heat

Y2

Compressor contactor (stage 2)

Pump System

L

Sends output when set to Em. Heat [11]

(TH6220D only) [8]

 

MCR29449

 

 

 

 

Rc

Power [1]

 

3H/2C Heat

 

 

 

 

 

 

R

[R+Rc joined by jumper]

 

Pump System

 

 

Y

Compressor contactor

 

(TH6320U only) [10]

Y2

MCR29452

C

24VAC common [3]

 

 

Rc

Power [1]

E

 

 

 

 

O/B

Changeover valve [7]

 

R

[R+Rc joined by jumper]

 

G

Fan relay

 

 

Y

Compressor contactor (stage 1)

Aux

Auxiliary heat relay [12]

 

C

24VAC common [3]

 

E

Emergency heat relay [12]

 

O/B

Changeover valve [7]

 

L

Sends output when set to Em. Heat [11]

G

Fan relay

 

 

 

 

 

 

Aux/E

Auxiliary/Emergency heat relay

2H/1C Heat

 

 

Y2

Compressor contactor (stage 2)

Pump System

 

 

L

Sends output when set to Em. Heat [11]

(TH6320U only) [8]

 

 

 

 

 

 

Rc

Power [1]

E

MCR29450

 

 

 

 

R

[R+Rc joined by jumper]

 

 

 

 

 

Y

Compressor contactor

 

 

 

 

 

C

24VAC common [3]

 

 

 

 

 

 

O/B

Changeover valve [7]

 

 

 

 

 

G

Fan relay

 

 

 

 

 

 

Aux/E

Auxiliary/Emergency heat relay

 

 

 

 

L

Sends output when set to Em. Heat [11]

See [notes] on page 4.

 

 

 

 

 

 

 

 

Thermostat mounting

Align the 4 tabs on the wallplate with slots on the back of the thermostat, then push gently until the thermostat snaps in place.

Push excess wire back into the wall opening.

Plug wall opening with non-flammable insulation.

ENGLISH

MCR29453

5

69-1920EFS—01

Installation Guide

Installer setup

Follow the procedure below to configure the thermostat to match the installed heating/cooling system, and customize feature operation as desired.

Function

Setting

number

 

1

0

Done

Next

 

MCR29454

To begin, press and hold the σ and FAN buttons until the display changes.

Press σ or τ to change settings.

Press NEXT to advance to the next function.

Press DONE to exit and save settings.

Setup function

Settings & options (factory default in bold)

Shaded areas below apply only to TH6320U/TH6220D or as otherwise noted.

1 System type

0

1 heat/1 cool conventional

 

1

1 heat/1 cool heat pump (no aux. heat)

 

2

Heat only — 2-wire systems, 3-wire zone valves (Series 20), and

 

 

normally open zone valves

 

3

Heat only with fan

 

4

Cool only

 

5

2 heat/1 cool heat pump (with aux. heat)

 

6

2 heat/2 cool conventional

 

7

2 heat/1 cool conventional

 

8

1 heat/2 cool conventional

 

9

2 heat/2 cool heat pump (no aux. heat) - TH6320U only

 

10

3 heat/2 cool heat pump (with aux. heat) - TH6320U only

 

 

 

ENGLISH

2

Changeover valve

0

Changeover valve (O/B terminal energized in cooling)

 

(O/B terminal)

1

Changeover valve (O/B terminal energized in heating)

3

Fan control

0

Gas or oil furnace — equipment controls fan in heating

 

(heating)

1

Electric furnace — thermostat controls fan in heating

5

Stage 1 heat cycle

5

For gas or oil furnaces of less than 90% efficiency

 

rate (CPH: cycles/hour)* 1

For steam or gravity systems

 

 

3

For hot water systems & furnaces of over 90% efficiency

 

 

9

For electric furnaces

 

 

 

 

6

Stage 2 heat cycle

5

For gas or oil furnaces of less than 90% efficiency

 

rate/Auxiliary heat

1

For steam or gravity systems

 

cycle rate (CPH)*

3

For hot water systems & furnaces of over 90% efficiency

 

 

9

For electric furnaces

 

 

 

 

7

Auxiliary heat cycle

5

For gas or oil furnaces of less than 90% efficiency

 

rate (CPH)*

1

For steam or gravity systems

 

 

3

For hot water systems & furnaces of over 90% efficiency

 

Only TH6320U

9

For electric furnaces

 

for 3H/2C Heat Pumps

 

 

 

 

 

 

8

Emergency heat cycle

9

For electric emergency heat

 

rate (CPH)*

1

For steam or gravity systems

 

 

3

For hot water systems & furnaces of over 90% efficiency

 

 

5

For gas or oil furnaces of less than 90% efficiency

 

 

 

 

*[Other cycle rate options: 2, 4, 6, 7, 8, 10, 11 or 12 CPH]

69-1920EFS—01

6

Continued on next page

 

FocusPRO® TH6000 Series

 

 

Installer setup

 

 

 

Setup function

Settings & options (factory default in bold)

Shaded areas below apply only to TH6320U/TH6220D or as otherwise noted.

9

Stage 1 compressor

3

Recommended for most compressors

 

 

cycle rate (CPH)

 

[Other cycle rate options: 1, 2, 4, 5 or 6 CPH]

 

10

Stage 2 compressor

3

Recommended for most compressors

 

 

cycle rate (CPH)

 

[Other cycle rate options: 1, 2, 4, 5 or 6 CPH]

 

12

Manual/Auto

0

Manual changeover (Heat/Cool/Off)

 

 

changeover

1

Auto changeover (Heat/Cool/Auto/Off) **See page 8

 

 

2

Auto changeover only (Auto) **See page 8

 

13

Adaptive Intelligent

1

On**See page 8

 

 

Recovery

0

Off

 

14

Temperature

0

Fahrenheit

 

 

display

1

Celsius

 

15

Compressor

5

Five-minute compressor off time **See page 8

 

protection

 

[Other options: 0, 1, 2, 3 or 4-minute off time]

 

16

Schedule format

0

5/2 (programmable weekdays and weekends)

 

 

 

1

5/1/1 (weekdays, Saturday & Sunday programmable)

27

Heat temperature

90

Max. heat temperature setting is 90° F (32° C)

 

range stops

 

[Other options: 40 °F to 89 °F (4.5 °C to 31.5 °C)]

 

28

Cool temperature

50

Min. cool temperature setting is 50° F (10° C)

 

 

range stops

 

[Other options: 51 °F to 99 °F (10.5 °C to 37 °C)]

 

Installer system test

 

 

 

 

 

Test number

System status

 

 

 

10

0

To begin, press and hold the σ and τ

MCR29455

Press σ / τ to turn system on/off.

buttons until the display changes.

Press NEXT to advance to next test.

 

 

Press DONE to terminate system test.

 

 

 

System test

System status

 

Shaded areas below apply only to TH6320U/TH6220D or as otherwise noted.

10

Heating system

0

Heat and fan turn off.

 

 

1

Stage 1 heat turns on. Fan turns on if Setup Function 1 is set to 1,

 

 

 

5, 9 or 10 OR Setup Function 3 is set to 1 **See page 6

 

 

2

Stage 2 heat turns on

 

 

3

Stage 3 heat turns on - TH6320U only

 

 

 

 

20

Emergency heating

0

Heat and fan turn off

 

system

1

Heat and fan turn on

 

 

2

Stage 2 heat turns on (auxiliary heat) - TH6220D only

30

Cooling system

0

Compressor and fan turn off

 

 

1

Compressor and fan turn on

 

 

2

Stage 2 compressor turns on

40

Fan system

0

Fan turns off

 

 

1

Fan turns on

CAUTION: Compressor protection is bypassed during testing. To prevent equipment damage, avoid cycling the compressor quickly.

ENGLISH

7

69-1920EFS—01

Installation Guide

Special functions

Auto Changeover (Setup Function 12): When set to Auto, the thermostat automatically selects heating or cooling depending on the indoor temperature. The thermostat will automatically adjust heat and cool settings to maintain a 3-degree separation (fixed). Note: If you select Auto Changeover Only, the System Setting on the thermostat will stay locked in the Auto position, preventing the user from changing it to Em Heat, Heat, Cool or Off.

Adaptive Intelligent Recovery(Setup Function 13): Allows the thermostat to “learn” how long the furnace and air conditioner take to reach programmed temperature settings, so the temperature is reached at the scheduled time.

Compressor Protection (Setup Function 15): Forces the compressor to wait a few minutes before restarting, to prevent damage. During the wait time, the message Cool On or Heat On

(heat pumps only) will flash on the display.

Accessories & replacement parts

Please contact your distributor to order replacement parts.

Battery holder. . . . . . . . . .

. . .

.

. Part Number 50007072-001

Cover plate assembly*. . . . . .

. . .

.

. Part Number 50002883-001

12 pack of medium cover plates*. .

. . .

.

. Part Number 50007298-001

*Use to cover marks left by old thermostats.

Specifications

Temperature Ranges

Heat: 40° to 90°F (4.5° to 32°C)

Cool: 50° to 99°F (10° to 37°C)

Operating Ambient Temperature

32° to 120°F (0° to 48.9°C)

Shipping Temperature

-20° to 120°F (-28.9° to 48.9°C)

Operating Relative Humidity

5% to 90% (non-condensing)

Physical Dimensions

3-9/16" H x 5-13/16" W x 1-1/2" D 91 mm H x 147 mm W x 38 mm D

Electrical Ratings

 

 

Terminal

Voltage (50/60Hz)

Running Current

W Heating

 

20-30 Vac

0.02-1.0 A

(Powerpile)

 

750 mV DC

100 mA DC

W2 (Aux) Heating

20-30 Vac

0.02-0.5 A

Y Cooling

 

20-30 Vac

0.02-1.0 A

Y2 Cooling

 

20-30 Vac

0.02-1.0 A

G Fan

 

20-30 Vac

0.02-0.5 A

O/B Changeover

20-30 Vac

0.02-0.5 A

E Emergency heat

20-30 Vac

0.02-1.0 A

L Output

 

20-30 Vac

0.02-0.5 A

Automation and Control Solutions

Honeywell International Inc.

Honeywell Limited-Honeywell Limitée

1985 Douglas Drive North

35 Dynamic Drive

Golden Valley, MN 55422

Toronto, Ontario M1V 4Z9

http://customer.honeywell.com

Printed in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers.

® U.S. Registered Trademark.

© 2009 Honeywell International Inc.

69-1920EFS—01 M.S. 05-09

Loading...