Honeywell T87 User Manual

0 (0)
Honeywell T87 User Manual

T87 Range Stops

APPLICATION

Use the 50010944-001 range stops with the T87K, N thermostats to limit the minimum and maximum temperature settings.

The 50010944-001 contains two range stop scales and two #2-28 x 3/8 phillips pan head screws.

HIGH LIMIT

SETTING

 

 

RANGE STOP

80

70

 

60

LOW LIMIT

 

SETTING

 

 

SCREW (2)

50

M13675

Fig. 1. Range stop and screws (Fahrenheit range).

HIGH LIMIT

SETTING

 

 

RANGE STOP

26

20

 

15

LOW LIMIT

 

SETTING

 

 

SCREW (2)

09

M13676

Fig. 2. Range stop and screws (Celsius range).

INSTALLATION INSTRUCTIONS

INSTALLATION

1.Set the thermostat to a temperature setting in the middle of the upper and lower range desired.

2.Remove the thermostat from its base (if already attached).

3.On the back of the thermostat, align the range stop with the holes on the back of the thermostat. See Fig. 3.

 

70

60

80

 

50

M13679

Fig. 3. Aligning range stop with thermostat.

4.Using the temperature markings on the range stop, insert supplied screws into the minimum and/or maximum range stop holes and tighten. Refer to Tables 1 and 2 for range stop temperatures. See Figs. 4 and 5.

5.Mount the thermostat onto its base and set desired temperature. See Fig. 5.

69-1864EFS

T87 RANGE STOPS

 

 

64°

70

 

60°

80

60

56° LOW

 

LIMIT

 

 

SETTING

FAHRENHEIT SCALE

 

50°

 

 

 

 

50

 

 

46°

 

 

42°

 

16.5°

20

 

15°

26

 

12° LOW

15

 

LIMIT

 

 

SETTING

 

 

10°

 

 

 

 

09

CELSIUS SCALE

 

 

 

 

 

M13677

Fig. 4. Low range stop settings.

76° HIGH LIMIT SETTING

70°

80°

Table 1. Low Limit Range Stop

°F

°C

 

 

42

4

44

5

 

 

46

6.5

 

 

48

8

 

 

50

9

 

 

52

10

 

 

54

11

 

 

56

12

 

 

58

13

 

 

60

14.5

 

 

62

15.5

 

 

64

16.5

 

 

66

17.5

 

 

68

19

 

 

70

20

 

 

72

21

 

 

74

22.5

 

 

76

23.5

 

 

78

24.5

 

 

80

26

 

 

84°

88°

27° 28°

29°

70 80

FAHRENHEIT SCALE

60

 

23.5° HIGH LIMIT

 

 

SETTING

 

 

21°

19°

 

 

 

20

 

 

26

 

 

 

15

 

CELSIUS SCALE

 

Table 2. High Limit Range Stop

 

°F

°C

 

88

31

 

86

29.5

50

84

28

 

82

27.5

 

80

26

 

78

25

 

76

24

 

74

22.5

 

72

21.5

09

70

20

 

68

19

 

66

18

 

64

17

 

62

16

M13678

60

14.5

Fig. 5. High range stop settings.

Automation and Control Solutions

 

 

 

 

Honeywell International Inc.

Honeywell Limited-Honeywell Limitée

 

 

 

1985 Douglas Drive North

35 Dynamic Drive

 

 

 

Golden Valley, MN 55422

Scarborough, Ontario M1V 4Z9

 

 

 

 

 

 

customer.honeywell.com

 

 

 

 

 

 

 

 

® U.S. Registered Trademark

© 2005 Honeywell International Inc.

69-1864EFS M.S. Rev. 12-05

Loading...
+ 4 hidden pages