Texas Instruments 74ACT11004PWR, 74ACT11004N, 74ACT11004DWR, 74ACT11004DW, 74ACT11004DBR Datasheet

...
0 (0)

 

 

 

 

 

74ACT11004

 

 

 

 

 

HEX INVERTER

 

SCAS215B ± JANAURY 1988 ± REVISED JUNE 1997

 

 

 

 

 

 

D Inputs Are TTL-Voltage Compatible

DB, DW, N, OR PW PACKAGE

D Flow-Through Architecture Optimizes PCB

 

(TOP VIEW)

 

 

 

 

 

 

 

 

Layout

1Y

 

1

20

1A

 

D Center-Pin VCC and GND Configurations

 

2Y

 

2

19

2A

 

Minimize High-Speed Switching Noise

3Y

 

3

18

3A

 

D EPIC (Enhanced-Performance Implanted

GND

 

4

17

NC

 

CMOS) 1-mm Process

GND

 

5

16

VCC

 

 

 

D 500-mA Typical Latch-Up Immunity at

GND

 

6

15

VCC

 

 

°

GND

 

7

14

NC

125 C

4Y

 

8

13

4A

D Package Options Include Plastic

 

 

5Y

 

9

12

5A

Small-Outline (DW), Shrink Small-Outline

 

 

 

 

(DB), and Thin Shrink Small-Outline (PW)

6Y

 

10

11

6A

 

 

 

Packages and Standard Plastic (N) 300-mil

DIPs

NC ± No internal connection

 

description

This device contains six independent inverters. It performs the Boolean function Y = A.

The 74ACT11004 is characterized for operation from ±40°C to 85°C.

 

 

 

FUNCTION TABLE

 

 

 

 

 

(each inverter)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT

 

OUTPUT

 

 

 

 

 

A

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

 

L

 

 

 

 

 

L

 

H

 

 

 

 

 

 

 

 

 

 

 

logic symbol²

 

 

 

 

 

20

 

 

 

 

 

1

 

1A

 

 

1

 

 

1Y

 

 

 

 

19

 

 

 

 

 

2

 

 

 

 

 

 

 

2A

 

 

 

 

 

 

2Y

 

 

 

 

 

 

 

18

 

 

 

 

 

3

 

 

 

 

 

 

 

3A

 

 

 

 

 

3Y

 

 

 

8

13

 

 

 

 

 

4Y

 

 

 

 

 

4A

 

 

 

 

 

 

 

 

 

 

 

12

 

 

 

 

 

9

 

 

 

 

 

 

 

5A

 

 

 

 

 

5Y

 

 

 

 

 

11

 

 

 

 

 

10

 

 

 

 

 

 

 

6A

 

 

 

 

 

 

6Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

² This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.

Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.

EPIC is a trademark of Texas Instruments Incorporated.

PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.

Copyright 1997, Texas Instruments Incorporated

POST OFFICE BOX 655303 DALLAS, TEXAS 75265

1

Texas Instruments 74ACT11004PWR, 74ACT11004N, 74ACT11004DWR, 74ACT11004DW, 74ACT11004DBR Datasheet

74ACT11004 HEX INVERTER

SCAS215B ± JANAURY 1988 ± REVISED JUNE 1997

logic diagram (positive logic)

20

1

1A

1Y

19

2

2A

2Y

18

3

3A

3Y

13

8

4A

4Y

12

9

5A

5Y

11

10

6A

6Y

absolute maximum ratings over operating free-air temperature range (unless otherwise noted)²

Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . ±0.5 V to 7

V

Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

±0.5 V to VCC + 0.5

V

Output voltage range, VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

±0.5 V to VCC + 0.5

V

Input clamp current, IIK (VI < 0 or VI > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . ±20 mA

Output clamp current, IOK (VO < 0 or VO > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . ±50 mA

Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . ±50 mA

Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . ±150 mA

Package thermal impedance, θJA (see Note 2): DB package . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . 115°C/W

DW package . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . 97°C/W

N package . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . 67°C/W

PW package . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . 128°C/W

Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . ±65°C to 150°C

²Stresses beyond those listed under ªabsolute maximum ratingsº may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under ªrecommended operating conditionsº is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.

NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.

2.The package thermal impedance is calculated in accordance with JESD 51, except for through-hole packages, which use a trace length of zero.

recommended operating conditions

 

 

MIN

MAX

UNIT

 

 

 

 

 

 

 

VCC

Supply voltage

4.5

5.5

V

 

VIH

High-level input voltage

2

 

V

 

VIL

Low-level input voltage

 

0.8

V

 

VI

Input voltage

0

VCC

V

 

VO

Output voltage

0

VCC

V

 

IOH

High-level output current

 

±24

mA

 

IOL

Low-level output current

 

24

mA

 

t/ v

Input transition rise or fall rate

0

10

ns/V

 

 

 

 

 

 

 

TA

Operating free-air temperature

±40

85

°C

 

 

 

 

 

 

 

 

 

 

 

 

 