SYSMAC CJ-series CJ2H (Built-in EtherNet/IP) CPU Units
CJ2H-CPU6@-EIP
CSM_CJ2H-CPU-EIP_DS_E_2_1
Flagship PLCs with Built-in
Multifunctional Ethernet Port
•Small, Fast, Flexible:
The CJ2 CPU Units inherit and improve CJ1 features while also adding EtherNet/IP as a standard feature for high-speed, high-capacity Ethernet-based networking.
CJ2H-CPU6@-EIP
Features
•High-speed, high-capacity EtherNet/IP is built into every model.
•The CIP communications protocol is supported for direct access to multivendor devices.
•Tag memory provided for easy access from host PCs and PTs.
•Even more program memory and data memory.
•Superior high-speed control performance: LOAD instructions execute in 16 ns, SINE instructions in 0.59 μs.
1
CJ2H-CPU6@-EIP
Ordering Information
CJ2H (Built-in EtherNet/IP) CPU Units
|
|
Specifications |
|
Current |
|
|
||
|
|
|
consumption (A) |
|
|
|||
|
|
|
|
|
|
|
||
Product |
|
|
|
LD |
|
|
Model |
Standards |
name |
I/O capacity/Mountable |
Program |
|
instruction |
|
|
||
Data memory capacity |
5 V |
24 V |
|
|
||||
|
Units (Expansion Racks) |
capacity |
execution |
|
|
|||
|
|
|
|
|
|
|||
|
|
|
|
time |
|
|
|
|
|
|
|
832K words |
|
|
|
CJ2H-CPU68-EIP |
|
|
|
400K steps |
DM: 32K words |
|
|
|
|
|
|
|
|
EM: 32K words × 25 banks |
|
|
|
|
|
CJ2H |
|
|
512K words |
|
|
|
|
|
(Built-in |
|
|
|
|
|
CJ2H-CPU67-EIP |
|
|
|
250K steps |
DM: 32K words |
|
|
|
|
||
EtherNet/IP) |
|
|
|
|
|
|||
|
|
EM: 32K words × 15 banks |
|
|
|
|
|
|
CPU Units |
|
|
|
|
|
|
|
|
|
|
352K words |
|
0.82 |
|
|
|
|
|
2,560 points / 40 Units |
|
0.016 μs |
− |
CJ2H-CPU66-EIP |
UC1, N, L, |
||
|
150K steps |
DM: 32K words |
(See |
|||||
|
(3 Expansion Racks max.) |
CE |
||||||
|
|
EM: 32K words × 10 banks |
|
note.) |
|
|
||
|
|
|
|
|
|
|
||
|
|
|
160K words |
|
|
|
CJ2H-CPU65-EIP |
|
|
|
100K steps |
DM: 32K words |
|
|
|
|
|
|
|
|
EM: 32K words × 4 banks |
|
|
|
|
|
|
|
|
160K words |
|
|
|
CJ2H-CPU64-EIP |
|
|
|
50K steps |
DM: 32K words |
|
|
|
|
|
|
|
|
EM: 32K words × 4 banks |
|
|
|
|
|
Note: Add 0.15 A per Adapter when using NT-AL001 RS-232C/RS-232A Adapters.
Add 0.04 A per Adapter when using CJ1W-CIF11 RS-422A Adapters.
International Standards
•The standards indicated in the "Standards" column are those current for UL, CSA, cULus, NK, and Lloyd standards and EC Directives as of the end of April 2008. The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives
•Ask your OMRON representative for the conditions under which the standards were met.
Accessories
The following accessories come with CPU Unit:
Item |
Specification |
Battery |
CJ1W-BAT01 |
End Cover |
CJ1W-TER01 (necessary to be mouned at the right end of CPU Rack) |
End Plate |
PFP-M (2 pcs) |
Serial Port (RS-232C) Connector |
Connector set for serial port connection (D-SUB 9-pin male connector) |
|
|
2
CJ2H-CPU6@-EIP
General Specifications
|
Item |
|
|
|
|
CJ2H- |
|
|
|
|
|
CPU64-EIP |
|
CPU65-EIP |
|
CPU66-EIP |
|
CPU67-EIP |
|
CPU68-EIP |
|
|
|
|
|
|
|
|||||
Enclosure |
Mounted in a panel |
|
|
|
|
|
|
|
||
Grounding |
Less than 100 Ω |
|
|
|
|
|
|
|
||
CPU Rack Dimensions |
90 mm × 65 mm × 80 mm (H × D × W) |
|
|
|
|
|
||||
Weight |
280 g or less |
|
|
|
|
|
|
|
||
Current Consumption |
5 VDC, 0.82 A |
|
|
|
|
|
|
|
||
|
Ambient Operating Temperature |
0 to 55°C |
|
|
|
|
|
|
|
|
|
Ambient Operating Humidity |
10% to 90% |
|
|
|
|
|
|
|
|
|
Atmosphere |
Must be free from corrosive gases. |
|
|
|
|
|
|||
|
Ambient Storage Temperature |
−20 to 70°C (excluding battery) |
|
|
|
|
|
|||
|
Altitude |
2,000 m or less |
|
|
|
|
|
|
|
|
|
Pollution Degree |
2 or less: Conforms to JIS B3502 and IEC 61131-2. |
|
|
|
|||||
Use Environment |
Noise Immunity |
2 kV on power supply line (Conforms to IEC 61000-4-4.) |
|
|
|
|||||
Overvoltage Category |
Category II: Conforms to JIS B3502 and IEC 61131-2. |
|
|
|
||||||
|
|
|
|
|||||||
|
EMC Immunity Level |
Zone B |
|
|
|
|
|
|
|
|
|
|
Conforms to JIS C60068-2-6. |
|
|
|
|
|
|||
|
Vibration Resistance |
5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz |
|
|
|
|||||
|
Acceleration of 9.8 m/s2 for 100 min in X, Y, and Z directions (10 sweeps of 10 min each = |
|||||||||
|
|
|||||||||
|
|
100 min total) |
|
|
|
|
|
|
|
|
|
Shock Resistance |
Conforms to JIS C60068-2-27. |
|
|
|
|
|
|||
|
147 m/s2, 3 times in X, Y, and Z directions (100 m/s2 for Relay Output Units) |
|
||||||||
|
|
|
||||||||
Battery |
Life |
5 years at 25°C |
|
|
|
|
|
|
|
|
Model |
CJ1W-BAT01 |
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|||
Applicable Standards |
Conforms to cULus and EC Directives. |
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
3
CJ2H-CPU6@-EIP
Performance Specifications
|
Items |
|
|
|
CJ2H- |
|
|
||
|
|
|
|
|
|
|
|
||
|
CPU64-EIP |
|
CPU65-EIP |
CPU66-EIP |
|
CPU67-EIP |
CPU68-EIP |
||
|
|
|
|
|
|||||
User Memory |
|
|
50K steps |
|
100K steps |
150K steps |
|
250K steps |
400K steps |
I/O Bits |
|
|
2,560 bits |
|
|
|
|
|
|
|
|
|
Normal Mode: 200 μs |
|
|
|
|
||
|
Overhead Processing Time |
(If tag data links are used with EtherNet/IP, add the following to the above time: 100 μs + Number of transferred |
|||||||
|
words × (0.33 μs or 0.87 μs *)) |
|
|
|
|
||||
|
|
|
|
|
|
|
|||
|
|
|
* When High-speed interrupt function is used |
|
|
||||
|
Execution Time |
Basic Instructions: 0.016 μs min.; |
|
|
|
|
|||
Processing |
Special Instructions: 0.048 μs min. |
|
|
|
|
||||
|
|
|
|
|
|
||||
Speed |
|
I/O Interrupts and |
Start time of interrupt task : 26 μs or 17 μs * (30 μs in unit Ver.1.0) |
|
|||||
|
|
Return time to cyclic task : 11 μs or 8 μs * (15 μs in unit Ver.1.0) |
|
|
|||||
|
|
External Interrupts |
|
|
|||||
|
|
* When High-speed interrupt function is used |
|
|
|||||
|
Interrupts |
|
|
|
|||||
|
Scheduled |
Start time of interrupt task : 22 μs or 13 μs * (27 μs in unit Ver.1.0) |
|
||||||
|
|
|
|||||||
|
|
Return time to cyclic task : 11 μs or 8 μs * (15 μs in unit Ver.1.0) |
|
|
|||||
|
|
Interrupts |
|
|
|||||
|
|
* When High-speed interrupt function is used |
|
|
|||||
|
|
|
|
|
|||||
Maximum Number of Connectable Units |
Total per CPU Rack or Expansion Rack: 10 Units max.; |
|
|
||||||
Total per PLC: 40 Units max. |
|
|
|
|
|||||
|
|
|
|
|
|
|
|||
Maximum Number of Expansion Racks |
3 max. |
|
|
|
|
|
|
||
|
I/O Area |
2,560 bits (160 words): Words CIO 0000 to CIO 0159 |
|
|
|||||
|
Link Area |
3,200 bits (200 words): Words CIO 1000 to CIO 1199 |
|
|
|||||
|
CPU Bus Unit Area |
6,400 bits (400 words): Words CIO 1500 to CIO 1899 |
|
|
|||||
CIO Area |
Special I/O Unit Area |
15,360 bits (960 words): Words CIO 2000 to CIO 2959 |
|
|
|||||
|
DeviceNet Area |
9,600 bits (600 words): Words CIO 3200 to CIO 3799 |
|
|
|||||
|
Internal I/O Area |
3,200 bits (200 words): Words CIO 1300 to CIO 1499 |
|
|
|||||
|
37,504 bits (2,344 words): Words CIO 3800 to CIO 6143 |
|
|
||||||
|
|
|
Cannot be used for external I/O. |
|
|
|
|
||
Work Area |
|
|
8,192 bits (512 words): Words W000 to W511 |
|
|
||||
|
|
Cannot be used for external I/O. |
|
|
|
|
|||
|
|
|
|
|
|
|
|||
|
|
|
8,192 bits (512 words): Words H000 to H511 |
|
|
||||
Holding Area |
|
|
Bits in this area maintain their ON/OFF status when PLC is turned OFF or operating mode is changed. |
||||||
|
|
Words H512 to H1535: These words can be used only for function blocks. They can be used only for function |
|||||||
|
|
|
|||||||
|
|
|
block instances (i.e., they are allocated only for internal variables in function blocks). |
|
|||||
|
|
|
Read-only: 31,744 bits (1,984 words) |
|
|
|
|
||
Auxiliary Area |
|
|
• 7,168 bits (448 words): Words A0 to A447 |
|
|
||||
|
|
• 24,576 bits (1,536 words): Words A10000 to A11535 |
|
|
|||||
|
|
|
|
|
|||||
|
|
|
Read/write: 16,384 bits (1,024 words) in words A448 to A1471 |
|
|
||||
Temporary Area |
|
|
16 bits: TR0 to TR15 |
|
|
|
|
||
Timer Area |
|
|
4,096 timer numbers (T0000 to T4095 (separate from counters)) |
|
|
||||
Counter Area |
|
|
4,096 counter numbers (C0000 to C4095 (separate from timers)) |
|
|
||||
|
|
|
32k words (Bits in the DM Area can be addressed either by bit or by word.) |
|
|||||
DM Area |
|
|
DM Area words for Special I/O Units: D20000 to D29599 (100 words × 96 Units) |
|
|||||
|
|
|
DM Area words for CPU Bus Units: D30000 to D31599 (100 words × 16 Units) |
|
|||||
|
|
|
32k words/bank × 25 banks max.: E00_00000 to E18_32767 max. |
|
|
||||
EM Area |
|
|
(Bits in the EM Area can be addressed either by bit or by word.) |
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
32K words × 4 |
|
32K words × 4 |
32K words × 10 |
|
32K words × 15 |
32K words × 25 |
|
|
|
|
|
|
|||||
|
|
|
banks |
|
banks |
banks |
|
banks |
banks |
|
|
Force-set/reset |
EM3 |
|
EM3 |
EM6 to EM9 |
|
EM7 to EME |
EM11 to EM18 |
|
|
Enabled Banks |
Force-setting/resetting is enabled only for areas specified for automatic address allocation. |
||||||
Index Registers |
|
|
IR0 to IR15 |
|
|
|
|
|
|
|
|
These are special registers for storing PLC memory addresses for indirect addressing. (Index Registers can |
|||||||
|
|
|
be set so that they are unique in each task or so that they are shared by all tasks.) |
|
|||||
Cyclic Task Flag Area |
128 flags |
|
|
|
|
|
|
||
Memory Card |
|
|
128 MB, 256 MB, or 512 MB |
|
|
|
|
||
|
|
|
PROGRAM Mode: Programs are not executed. Preparations can be executed prior to program execution in |
||||||
Operating Modes |
|
this mode. |
|
|
|
|
|||
MONITOR Mode: Programs are executed, and some operations, such as online editing, and changes to |
|||||||||
|
|
|
|
present values in I/O memory, are enabled in this mode. |
|
||||
|
|
|
RUN Mode: |
Programs are executed. This is the normal operating mode. |
|
||||
Execution Mode |
|
|
Normal Mode |
|
|
|
|
|
|
|
|
|
Ladder Logic (LD), |
|
|
|
|
|
|
Programming Languages |
Sequential Function Charts (SFC), |
|
|
|
|
||||
Structured Text (ST), and |
|
|
|
|
|||||
|
|
|
|
|
|
|
|||
|
|
|
Instruction Lists (IL) |
|
|
|
|
||
Function |
Maximum number of definitions |
2,048 |
|
|
|
|
|
|
|
Blocks |
Maximum number of instances |
2,048 |
|
|
|
|
|
|
|
|
Type of Tasks |
Cyclic tasks |
|
|
|
|
|
|
|
|
Interrupt tasks (Power OFF interrupt tasks, scheduled interrupt tasks, I/O interrupt tasks, and external interrupt |
||||||||
|
|
|
tasks) |
|
|
|
|
|
|
Tasks |
|
|
Cyclic tasks: 128 |
|
|
|
|
|
|
|
Number of Tasks |
Interrupt tasks: 256 |
|
|
|
|
|||
|
(Interrupt tasks can be defined as cyclic tasks to create extra cyclic tasks. Therefore, the total number of cyclic |
||||||||
|
|
|
|||||||
|
|
|
tasks is actually 384 max.) |
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
4
CJ2H-CPU6@-EIP
|
Items |
|
|
|
|
CJ2H- |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CPU64-EIP |
|
CPU65-EIP |
|
CPU66-EIP |
CPU67-EIP |
|
CPU68-EIP |
|
|
|
|
|
|
|||||
|
|
• Local symbols: Can be used only within a single task in the PLC. |
|
||||||
|
Type of Symbols |
• Global symbols: Can be used in all tasks in the PLC. |
|
|
|
||||
|
• Network symbols (tags): I/O memory in the CPU Unit can be externally accessed using symbols, depending |
||||||||
|
|
||||||||
|
|
on parameter settings. |
|
|
|
|
|
|
|
|
|
• BOOL (bit) |
|
|
|
|
|
|
|
|
|
• UINT (one-word unsigned binary) |
|
|
|
|
|||
|
|
• UDINT (two-word unsigned binary) |
|
|
|
|
|||
|
|
• ULINT (four-word unsigned binary) |
|
|
|
|
|||
|
|
• INT (one-word signed binary) |
|
|
|
|
|||
|
|
• DINT (two-word signed binary) |
|
|
|
|
|||
|
|
• LINT (four-word signed binary) |
|
|
|
|
|||
|
|
• UINT BCD (one-word unsigned BCD) *1 |
|
|
|
|
|||
|
|
• UDINT BCD (two-word unsigned BCD) *1 |
|
|
|
||||
|
|
• ULINT BCD (four-word unsigned BCD) *1 |
|
|
|
||||
|
Data Type of Symbols |
• REAL (two-word floating-point) |
|
|
|
|
|||
|
• LREAL (four-word floating-point) |
|
|
|
|
||||
|
|
|
|
|
|
||||
|
|
• CHANNEL (word) *1 |
|
|
|
|
|
|
|
Symbols |
|
• NUMBER (constant or number) *1 |
|
|
|
|
|||
|
• WORD (one-word hexadecimal) |
|
|
|
|
||||
(Variables) |
|
|
|
|
|
||||
|
• DWORD (two-word hexadecimal) |
|
|
|
|
||||
|
|
|
|
|
|
||||
|
|
• LWORD (four-word hexadecimal) |
|
|
|
|
|||
|
|
• STRING (1 to 255 ASCII characters) |
|
|
|
|
|||
|
|
• TIMER (timer) *2 |
|
|
|
|
|
|
|
|
|
• COUNTER (counter) *2 |
|
|
|
|
|||
|
|
*1. Cannot be used in Function blocks |
|
|
|
|
|||
|
|
*2. Can be used only in Function blocks |
|
|
|
|
|||
|
Maximum Size of Symbol |
32k words |
|
|
|
|
|
|
|
|
Array Symbols (Array Variables) |
One-dimensional arrays |
|
|
|
|
|
|
|
|
Number of Array Elements |
32,000 elements max. |
|
|
|
|
|
|
|
|
Number of Registrable Network |
20,000 max. |
|
|
|
|
|
|
|
|
Symbols (Tags) |
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
Length of Network Symbol (Tag) |
255 bytes max. |
|
|
|
|
|
|
|
|
Name |
|
|
|
|
|
|
|
|
|
Encoding of Network Symbols |
UTF-8 |
|
|
|
|
|
|
|
|
(Tags) |
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
Memory Capacity |
8,000 words |
|
|
16,000 words |
32,000 words |
|
||
|
|
|
|
|
|
|
|
|
|
|
(Up to 32k words × 25 banks when EM is specified in CX-Programmer) |
|
|||||||
|
|
|
|||||||
|
Number of Samplings |
Bits = 31, one-word data =16, two-word data = 8, four-word data = 4 |
|
||||||
|
Sampling Cycle |
1 to 2,550 ms (Unit: 1 ms) |
|
|
|
|
|
|
|
Data Tracing |
|
ON/OFF of specified bit |
|
|
|
|
|
|
|
|
Trigger Conditions |
Data comparison of specified word |
|
|
|
|
|||
|
Data size: 1 word, 2 words, 4 words |
|
|
|
|
||||
|
|
Comparison Method: Equals (=), Greater Than (>), Greater Than or Equals (≥), Less Than (<), Less Than or |
|||||||
|
|
Equals (≤), Not Equal (≠) |
|
|
|
|
|
|
|
|
Delay Value |
−32,768 to +32,767 ms |
|
|
|
|
|
|
|
File Memory |
|
Memory Card (128, 256, or 512 Mbytes) (Use the Memory Cards provided by OMRON.) |
|
||||||
|
EM file memory (Part of the EM Area can be converted for use as file memory.) |
|
|||||||
|
|
|
|||||||
Source/ |
Function block program |
|
|
|
|
|
|
|
|
Comment |
memory, comment file, program |
Capacity: 3.5 Mbytes |
|
|
|
|
|
|
|
Memory |
index file, symbol tables |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5