Livarno 6401–186L User Manual [cs, de, en]

Energy-Saving Ceiling Light
ENERGY-SAVING CEILING LIGHT
Assembly and safety advice
ENERGIESPAR-DECKENLEUCHTE
Montage- und Sicherheitshinweise
IAN 73850
Pokyny k montáži a bezpečnostní pokyny
Before reading, unfold the page containing the illustrations and familiarise yourself with all functions of the device.
Před čtením si otevřete stranu s obrázky a potom se seznamte se všemi funkcemi přístroje.
Klappen Sie vor dem Lesen die Seite mit den Abbildungen aus und machen Sie sich anschließend mit allen Funktionen des Gerätes vertraut.
GB Assembly and safety advice Page 5 CZ Pokyny k montáži a bezpečnostní pokyny Strana 11 DE / AT / CH Montage- und Sicherheitshinweise Seite 17
A
L
N
L
N
B
1
5
6
23b
3a
4
7
54 cm
9,8 cm
54 cm
7
7
9,8 cm
7
Table of Contents
Introduction
Proper use ............................................................................................................................................ Page 6
Description of parts ............................................................................................................................. Page 6
Technical data ..................................................................................................................................... Page 6
Scope of delivery ................................................................................................................................ Page 6
Safety
Safety notes ......................................................................................................................................... Page 6
Preparation
Required tools and materials .............................................................................................................. Page 7
Before installation ................................................................................................................... Page 8
Preparing for use
Mounting the light ............................................................................................................................... Page 8
Replacing a bulb ................................................................................................................................. Page 8
Maintenance and cleaning ............................................................................................... Page 9
Disposal ............................................................................................................................................ Page 9
Warranty and Service
Warranty Declaration ......................................................................................................................... Page 9
Service address ................................................................................................................................... Page 9
Declaration of conformity ................................................................................................................... Page 10
Manufacturer ....................................................................................................................................... Page 10
5 GB
Introduction / Safety
Energy-Saving Ceiling Light
Introduction
We congratulate you on the purchase of your new device. You have chosen
a high quality product. Please read carefully and completely through these operating instructions. Fold out the page with the illustrations. These instructions are part of the product and contain important information about bringing the product into use and its handling. Always observe all the safety advice. Check that the correct mains voltage is available and that all the parts have been properly assembled before bringing into use. Should you have any questions or be uncertain as to how to operate the device, please get in touch with your dealer or service point. Please keep these instructions in a safe place and hand them on to a third party if necessary.
Proper use
This light is suitable only for interior use, in dry and enclosed spaces. The lamp can be attached to all normally flammable surfaces. This device is intended for use only in a domestic, private household environ­ment.
Description of parts
Technical data
Article No.: 6401–186L Dimensions: approx. 73.5 x 16 x 5.5 cm
(L x W x H) Operating voltage: 230–240 V ∼, 50 Hz Bulbs: 220–240 V, 18 W, T8 Max. nominal output: 2 x 18 W Protection class: I / Protection class: IP20 (only suitable for
indoor use)
Scope of delivery
1 Ceiling light, model 6401–186L 2 Bulbs 18 W, T8 4 Dowels 4 Screws 1 Operating instructions
Safety
Safety notes
Damages due to failure to follow these instructions for use will void the product warranty! We assume no liability for secondary failures! We assume no liability for property or personal damages due to improper handling or failure to observe safety instructions!
1
Cover
2
Bulb
3a
End cap
3b
End cap
4
Opening for mains connection cable
5
Mains connection cable (external)
6
Terminal block
7
Mounting opening
6 GB
Avoid danger to life from
electric shock
Ensure that a qualified electrician or a person
trained to carry out electrical installations performs the electrical installation.
Check the lamp and the mains lead for damage
each time before connecting them. Never use your lamp if you discover that it is damaged in any way.
CAUTION! A damaged mains lead presents
a serious danger to life from electric shock. In the event of damage, repairs or other problems with the lamp, please contact the Service Centre or an electrician.
Before installation, remove the fuse for this circuit
or switch off the circuit breaker (0 setting) in the fuse box.
Before assembly, ensure that the available mains
voltage corresponds to the operating voltage necessary for the light (230–240 V ∼).
Never let the lamp come into contact with water
or other liquids.
Never open or insert anything into electrical
fittings or equipment. This may result in the danger of death from electric shock.
Do not attach the light to damp or conductive
substrates!
Avoid fire hazards and
risk of injury
RISK OF INJURY! Check every bulb for
damage immediately upon unpacking. Do not install the light if the bulbs are defective. If they are, contact the service point for a replacement.
RISK OF INJURY FROM BURNS! Ensure
the lamp has been switched off and allowed to cool before you touch it. Light bulbs develop a great deal of heat.
from the development of too much heat.
Replace any faulty bulbs with new ones immedi-
ately. Before replacing the bulb, always remove the fuse or switch the automatic cutout off.
Do not allow the lamp or the packaging materials
to lie around unattended. Plastic film or bags, Styrofoam etc. can turn into dangerous toys for children.
Do not use this light for dimmers or electronic
switches. It is not suitable for this mode of operation.
FIRE HAZARD! Fit the light so that
0.5 m
it is at least 0.5 m away from the material illuminated. Fire can result
Safety / Preparation
Working safely
Only use 220–240 V ∼ bulbs with a maximum
output of 18Watt.
Install the lamp so that it is protected from
moisture, wind and dirt.
Make careful preparations for the assembly and
take sufficient time. Clearly lay out all components and any additional tools or materials that might be required so that they are readily to hand.
Install the lamp on stable surfaces only (e.g.
masonry). Check before mounting the light to the ceiling whether the ceiling is suitable for supporting the light. If necessary seek advice from your local DIY supplier or a construction specialist.
Examine the ceiling before installation and
choose suitable installation fixings. For ceiling installation we have supplied fixings suitable for ordinary solid concrete or masonry construction.
Remain alert at all times and always watch what
you are doing! Always pay attention to what you are doing and act with common sense. Always proceed with caution and do not assemble the lamp if you cannot concentrate or feel unwell.
Preparation
Required tools and materials
The tools and materials referred to are not included in delivery. The details and values given are non­binding and for guidance only. The condition of the material is determined by the individual local conditions.
– Pencil / marking tool – Voltage tester – Crosstip screwdriver – Electric drill – Drill – Edge cutter – Ladder
7 GB
Before installation / Preparing for use
Before installation
Important: The electrical connection must be
carried out by a qualified electrician or someone trained to perform electrical installations. This person must be familiar with the properties of the light and all connection regulations.
Familiarise yourself with all instructions and
diagrams in this manual as well as with the light before installation.
Before installation, ensure that the cable that
the light is to be attached to is not live. To do this, remove the fuse or switch off the circuit breaker in the fuse box (0 position).
Use the voltage tester to check that there is
no voltage.
Preparing for use
Mounting the light
Note: you will need a drill for installation.
CAUTION! RISK OF INJURY! Refer to your
drill’s operating instructions.
Remove the end cap 3a by pressing it lightly
out of the fastening and moving it away to the side. The end cap, beneath which is the terminal
6
block (see label “Output wire”).
Remove the cover 1 by moving it away to the
side.
Remove both bulbs 2. Remove the respective
light bulb it out of the socket. Use a clean, lint-free cloth when you are replacing a bulb.
To uncover the mounting openings 7, remove
the chromed reflector inside the ceiling lamp. To do so, rotate the two white plastic caps ¼
turn to the left and pull them out. Then remove the reflector. Hold the light on the required position on the
ceiling.
Mark the drill holes for the installation openings 7
(see fig. B).
needed for connection, is marked
2
by turning it a ¼ turn and pulling
Drill the holes (ø approx. 6 mm, depth approx.
40 mm). Make sure that no electrical wiring is damaged during this operation.
Insert the dowels in the drilled holes. Use a
hammer if necessary.
Insert the supplied screws into the dowels and
let them project a distance of about 2.0 mm from the ceiling or mounting surface.
Insert the screws into the mounting openings
provided for them
7
of the light and align the light by pushing it to the left or to the right. Finally tighten the screws.
Now re-insert the chromed reflector and fasten
it with the previously removed plastic caps by inserting them into the openings provided for them and rotating them ¼ turn to the right.
Check for correct fitting. Route the mains connection cable (external) 5
through the opening provided for it end cap that was previously removed
4
in the
3a
.
Note: Carefully remove the pre-punched
connection plate from the opening mains connection cable (external) can guide the cable through the opening
4
for the
5
so you
4
Now connect the connection cable of the light
to the mains connection cable (external) means of the terminal block
6
provided.
5
by
Note: Ensure that each wire of the mains
connection cable (external) is properly con­nected in the correct place: live wire, black or brown = symbol L, neutral wire, blue = symbol N, protective earth wire, green-yellow = symbol
Insert the two bulbs 2 once again. Insert each
2
bulb
into the socket and tighten it with a
¼ turn. Check for correct fitting.
Reinsert the cover 1 and put the end cap 3a
back on the light housing. Ensure that the end cap is correctly seated.
Your light is now ready for operation.
Replacing a bulb
CAUTION! RISK OF ELECTRIC SHOCK!
To replace the bulb , first of all disconnect the light from the mains circuit. To do this, remove the fuse
.
.
8 GB
Loading...
+ 17 hidden pages