Introduction

This manual describes the hardware information. Read this manual thoroughly to understand how the CV-5001 Series works in order to maximize the performance of the system.

This manual covers the CV-5701/CV-5501/ CV-5001 in CV-5001 Series Ver. 2.2. All references, unless otherwise noted, pertain to the CV-5501. For more details on the differences between the models, see "Main Specifications" (page 7).

Always keep this manual in a safe place for future reference.

Ensure that the manual is passed to the end user in case of transfer of the unit.

Trademarks

"SD Memory Card" is a registered trademark of the SD association.

Other company names and product names are registered trademarks or trademarks of their respective companies.The TM mark and ® mark are omitted in this manual.

Package Contents

The equipment and accessories listed below are included in the package when shipped. Upon opening the carton, check that you have received all of the equipment and accessories listed below.

Standard Package

• Controller Unit x 1 (CV-5701/5501/5001, whichever is appropriate)

• SD card (OP-87133 (512MB): CV-5501/ 5001, CA-SD1G (1GB): CV-5701)) x 1 (pre-installed in SD1 slot)

• Remote control console (OP-84231) x1

• Controller instruction manual x 1

1

Safety Precautions

Symbols

The following warning symbols are used to ensure safety and to prevent human injury and/or damage to property when using the system.

DANGER

Indicates that the operator is at risk of death or serious physical injury if the system is improperly operated or this precaution is not followed.

Warning

Indicates that the operator is at risk of physical injury if the system is improperly operated or this precaution is not followed.

Caution

Indicates that property could be damaged (product malfunction, etc.) if the system is improperly operated or this precaution is not followed.

Note

Indicates important operating procedures that could be easily overlooked.

Reference

Indicates further information that may be useful to know.

General Cautions

Before starting work or before starting the system, confirm that all the functions of the system are working properly.

If any KEYENCE product fails, take full safety measures to prevent damage before using the system again.

If the system is used beyond published specifications or if the system is modified, the functions and performance cannot be guaranteed.

Please note that when the system is used in combination with other instruments, its functions and performance may be degraded.

Do not use this product for the purpose to protect a human body or a part of human body.

This product is not intended for use as explosion-proof product. Do not use this product in hazardous location and/or potentially explosive atmosphere.

Do not subject this unit or connected devices to a sudden change of temperature, as condensation may occur.

Warning

General

Do not use with any power voltage other than 24 V DC. Doing so may cause fire, electric shock, or product malfunction.

Do not disassemble or modify this unit. Doing so may cause fire or electric shock.

Operating environment and conditions

To use the system properly and safely, avoid installing this unit in the following locations: Doing so may cause fire, electric shock, or product malfunction.

Locations that contain moisture or dust, or that are poorly ventilated.

Locations where the system is exposed to direct sunlight or temperature increases.

Locations where there are flammable or corrosive gases.

Locations where the unit may be directly subjected to vibration or impact.

Locations where water, oil or chemicals may splash onto the unit.

Locations where static electricity occurs.

Keep this unit and cables away from high-tension cables or power lines. Otherwise, noise may cause malfunction or accidents.

Bundle cables with a spiral tubing material. Direct bundling will concentrate the cable load on the bindings, which can result in cable damage or short circuit.

This unit and optional devices are precision components. Do not subject them to vibration or impact.

Measures to be taken when an abnormality occurs

In the following cases, turn the power OFF immediately. Using the unit in an abnormal condition may cause fire, electric shock, or product malfunction. Contact your local KEYENCE office for repair.

If water or debris enters the system

If the system is dropped or the case is damaged

If smoke or a burning smell emits from the system

Caution

Usage

Before making any connections/disconnections, be sure to turn off the power of this unit and connected devices. Failure to do so may result in malfunction of the system or connected devices.

Do not turn the power off while you are programming. Otherwise, all or part of the program settings may be lost.

Do not block the ventilation holes. Otherwise, the inside temperature may rise and malfunction may occur.

Do not allow an excessive amount of sunlight or bright indoor light to enter the camera for a long period of time. Doing so may cause damage to the CCD inside the camera.

Note

Maintenance

Do not clean with benzene, thinner, or alcohol.

Doing so may cause discoloration or deformation of the unit. If the unit has any dirt on it, wipe it off with a cloth moistened with a mild detergent, then wipe with a dry cloth.

Precautions on Regulations and Standards

CE Marking

KEYENCE evaluates compliance with the requirements of the EMC directive according to how products fulfill the below conditions. KEYENCE has confirmed that the CV-5001 Series meets these requirements. When the CV-5001 Series is used in EU nations, take note of the following precautions.

EMC Directive (2004/108/EC)

• Applicable Standard EMI: EN61326-1, Class A

EMS: EN61326-1

Use cables shorter than 30 m to connect the controller unit and its external devices.

When connecting a CC-Link unit CA-NCL10E, attach a ferrite core (OP-84364, optional) within 300 mm on the CA-CNL10E side of the CC-Link dedicated cable.

However, these precautions do not guarantee that the customer’s entire machinery installation is compliant with the EMC Directive. The customer is responsible for determining the compliance of the overall machinery installation.

2

KEYENCE CV-5001 User Manual

Identifying Controls and Connectors

1Expansion unit connector 2 (left side)

Use to connect the illumination expansion unit CADC21E or CC-Link unit CA-NCL10E.

2Parallel I/O connector

Use to connect the parallel input/output signals.

3SD2 slot (upper), SD1 slot (lower)

Insert an SD card.

The lower slot (SD1) holds the included SD Card (512 MB or 1 GB) by factory default.

Note

SD Card 1 must be inserted while the device is operating.

4Modular connector

Use to connect the remote control console.

5RGB output terminal (SVGA)

Use to connect to an external monitor.

6USB port

Use to connect to the USB cable.

7Camera 2 connector

Use to connect camera 2.

8Expansion unit connector 1 (right side, only for CV-5701/ 5501)

Use to connect the camera expansion unit CV-E500.

9RS-232C port

Use to connect to the RS-232C communication cable.

10Camera 1 connector

Use to connect camera 1.

11Ethernet connector

Use to connect the Ethernet cable.

12Terminal Block I/O connector

Use to connect the power supply (24 V DC) and the input/output signals.

13Grounding terminal

Use to connect the installation line.

Installing the Controller Unit

Install the controller unit to DIN rail, or use the holes on the bottom of the controller to secure it with screws.

Note

Do not install the CV in a location with lots of dust or water vapor. The CV does not have a mechanism to protect the CV from dust or water. Dust or water entering the controller can cause damage to the CV.

Turn off the power to the controller when connecting or removing an expansion unit, a cable, or a terminal block. Connecting or removing the camera expansion unit, the cable, or the the terminal block while the power is being supplied may damage the controller or peripheral devices.

When a expansion unit is not connected, place the connector protection cover back on the controller. Using the controller with the connector exposed may cause damage to the controller.

Caution on Direction of Controller Mounting

Install the controller in the direction indicated by the circle as shown below. Do not install the controller in any other direction.

For ventilation, keep the space free of objects for 50 mm or more above the controller and 50 mm or more for both sides. Keep the space free of objects for 90 mm or more in the front of the connector panel to connect the cables safely.

When two or more controllers are installed side by side, keep the space free of objects for 50 mm or more between controllers, and 50 mm or more on top of both controllers.

 

50 mm

50 mm

50 mm

50 mm

50 mm

Note

Do not block the ventilation openings on the top and bottom of the controller. If the vents are blocked, heat is accumulated inside the machine and can cause system failure.

If the temperature inside the control panel (temperature at the bottom of the controller) exceeds the rating, use forced air-cooling or increase the free space around the system to improve ventilation until the operating ambient temperature drops below the rating.