HDS 9/14-4 ST HDS 12/14-4 ST
www . kaercher.
com/register - and - win
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Deutsch |
3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
English |
22 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Français |
41 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Italiano |
61 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Nederlands |
81 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Español |
101 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Português |
120 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Dansk |
139 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Norsk |
158 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Svenska |
177 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Suomi |
196 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Ελληνικά |
215 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Türkçe |
236 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Русский |
255 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magyar |
276 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Čeština |
295 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Slovenščina |
314 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Polski |
333 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Slovenčina |
352 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Eesti |
371 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Latviešu |
390 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Lietuviškai |
409 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Українська |
428 |
59648180 01/14
2
Lesen Sie vor der ersten Benutzung Ihres Gerätes diese Originalbetriebsanleitung, handeln Sie danach
und bewahren Sie diese für späteren Gebrauch oder für Nachbesitzer auf.
–Vor erster Inbetriebnahme Sicherheitshinweise Nr. 5.956309.0 unbedingt lesen!
–Bei Transportschaden sofort Händler informieren.
Umweltschutz . . . . . . . . . . . |
DE |
. . 1 |
Symbole in der Betriebsanleitung |
DE |
. . 1 |
Symbole auf dem Gerät . . . |
DE |
. . 1 |
Allgemeine Sicherheitshinweise |
DE |
. . 1 |
Bestimmungsgemäße Verwendung |
DE |
. . 2 |
Funktion . . . . . . . . . . . . . . . |
DE |
. . 2 |
Sicherheitseinrichtungen. . . |
DE |
. . 2 |
Geräteelemente . . . . . . . . . |
DE |
. . 3 |
Inbetriebnahme . . . . . . . . . . |
DE |
. . 4 |
Bedienung. . . . . . . . . . . . . . |
DE |
. . 4 |
Außerbetriebnahme . . . . . . |
DE |
. . 6 |
Stilllegung . . . . . . . . . . . . . . |
DE |
. . 6 |
Lagerung. . . . . . . . . . . . . . . |
DE |
. . 6 |
Transport. . . . . . . . . . . . . . . |
DE |
. . 6 |
Technische Daten . . . . . . . . |
DE |
. . 7 |
Pflege und Wartung . . . . . . |
DE |
. . 9 |
Hilfe bei Störungen . . . . . . . |
DE |
. 11 |
Zubehör. . . . . . . . . . . . . . . . |
DE |
. 13 |
Anlageninstallation . . . . . . . |
DE |
. 14 |
EG-Konformitätserklärung. . |
DE |
. 17 |
Garantie . . . . . . . . . . . . . . . |
DE |
. 17 |
Kundendienst . . . . . . . . . . . |
DE |
. 18 |
Wiederkehrende Prüfungen |
DE |
. 19 |
Symbole in der Betriebsanleitung
Gefahr
Warnung
Hochdruckstrahlen können bei unsachgemäßem Ge-
brauch gefährlich sein. Der Strahl darf nicht auf Perso-
nen, Tiere, aktive elektrische Ausrüstung oder auf das Gerät selbst gerichtet werden.
Allgemeine Sicherheitshinweise
–Jeweilige nationale Vorschriften des Gesetzgebers für Flüssigkeitsstrahler beachten.
–Jeweilige nationale Vorschriften des Gesetzgebers zur Unfallverhütung beachten. Flüssigkeitsstrahler müssen regelmäßig geprüft und das Ergebnis der Prüfung schriftlich festgehalten werden.
–Die Heizeinrichtung des Gerätes ist eine Feuerungsanlage. Feuerungsanlagen müssen regelmäßig nach den jeweiligen nationalen Vorschriften des Gesetzgebers überprüft werden.
–Bei Betrieb der Anlage in Räumen ist für eine gefahrlose Ableitung der Abgase zu sorgen (Rauchgasrohr ohne Zugunterbrecher). Weiter muss eine ausreichende Frischluftzufuhr vorhanden sein.
–Gemäß gültigen nationalen Bestimmungen muss dieser Hochdruckreiniger bei gewerblichem Einsatz erstmalig von einer befähigten Person in Betrieb genommen werden. KÄRCHER hat diese Erstinbetriebnahme bereits für Sie durchgeführt und dokumentiert. Die Dokumentation dazu erhalten Sie auf Nachfrage über Ihren KÄRCHER Partner. Bitte halten Sie bei Nachfragen zur Dokumentation die Teileund Werknummer des Gerätes bereit.
–Wir weisen darauf hin, dass das Gerät gemäß den gültigen nationalen Bestimmungen wiederkehrend von einer befähigten Person geprüft werden muss. Bitte wenden Sie sich dazu an Ihren KÄRCHER Partner.
–Sicherheitshinweise, die den verwendeten Reinigungsmitteln beigestellt sind (i. d. R. auf dem Verpackungsetikett) beachten.
DE - 1 |
3 |
–Das Gerät darf nur von einem Fachbetrieb nach den jeweiligen nationalen Vorschriften installiert werden.
–Bei der elektrischen Installation sind die jeweiligen nationalen Vorschriften des Gesetzgebers zu beachten.
–Einstellungen, Wartungsarbeiten und Reparaturen am Brenner dürfen nur von geschulten Kärcher-Kundendienstmon- teuren durchgeführt werden.
–Bei der Planung eines Kamins müssen die örtlich gültigen Richtlinien beachtet werden.
–Zum Schutz vor zurückspritzendem Wasser oder Schmutz geeignete Schutzkleidung und Schutzbrille tragen.
Gefahr
–Das Kaltwasser gelangt über die Motorkühlschlange und den Schwimmerbehälter zur Saugseite der Hochdruckpumpe. Im Schwimmerbehälter wird Enthärter zudosiert. Die Pumpe fördert Wasser und angesaugtes Reinigungsmittel durch den Durchlauferhitzer. Der Anteil von Reinigungsmittel im Wasser kann durch ein Dosierventil eingestellt werden. Der Durchlauferhitzer wird mit einem Brenner beheizt.
–Der Hochdruckausgang wird an ein im Gebäude vorhandenes Hochdrucknetz angeschlossen. An den Zapfstellen dieses Netzes erfolgt der Anschluss der Handspritzpistole mit einem Hochdruckschlauch.
4 |
DE - 2 |
1 |
12 |
2
4 |
9 |
11 |
10 |
|
|
|
|
|
7 |
8 |
3 |
6 |
5 |
|
|
|
|
Bild 1 |
|
|
|
1 |
Brenner |
7 |
Reinigungsmittel-Saugschlauch I |
2 |
Manometer |
8 |
Reinigungsmittel-Saugschlauch II (Option) |
3 |
Frischwasser-Zulauf mit Sieb |
9 |
Enthärterbehälter |
4 |
Hochdruckausgang |
10 |
Elektrozuleitung |
5 |
Brennstoffleitung Vorlauf |
11 |
Schwimmerbehälter |
6 |
Brennstoffleitung Rücklauf |
12 |
Bedienfeld |
Bedienfeld |
A |
Geräteschalter |
F |
Kontrolllampe Betriebsbereitschaft |
B |
Temperaturregler |
G |
Kontrolllampe Motorüberhitzung |
C |
Reinigungsmittel-Dosierventil I |
H |
Kontrolllampe Verkalkungsschutz |
D |
Reinigungsmittel-Dosierventil II (Option) |
I |
Stopfen - Entriegelungstaste Brennermotor |
E |
Kontrolllampe Brennerstörung |
|
|
|
DE |
- 3 |
5 |
Gefahr
–Anschlusswerte siehe Technische Daten und Typenschild.
–Der elektrische Anschluss muss von einem Elektroinstallateur ausgeführt werden und IEC 60364-1 entsprechen.
Gefahr
–Verbrühungsgefahr durch Heißwasser! Wasserstrahl nicht auf Personen oder Tiere richten.
–Verbrennungsgefahr durch heiße Anlagenteile! Bei Heißwasserbetrieb unisolierte Rohrleitungen und Schläuche nicht berühren. Strahlrohr nur an den Griffschalen festhalten. Abgasstutzen des Durchlauferhitzers nicht berühren.
–Vergiftungsoder Verätzungsgefahr durch Reinigungsmittel! Hinweise auf den Reinigungsmitteln beachten. Reinigungsmittel für Unbefugte unzugänglich aufbewahren.
Gefahr
–Elektrische Geräte und Anlagen,
–diese Anlage selbst,
–alle stromführenden Teile im Arbeitsbereich.
! |
Durch den aus dem Strahlrohr austretenden Wasserstrahl ent- |
steht eine Rückstoßkraft. Durch das abgewinkelte Strahlrohr wirkt eine Kraft nach oben.
Gefahr
–Verletzungsgefahr! Der Rückstoß des Strahlrohres kann Sie aus dem Gleichgewicht bringen. Sie können stürzen. Das Strahlrohr kann umherfliegen und Personen verletzen. Sicheren Standplatz suchen und Pistole gut festhalten. Hebel der Handspritzpistole niemals festklemmen.
–Den Strahl nicht auf andere oder sich selbst richten, um Kleidung oder Schuhwerk zu reinigen.
–Verletzungsgefahr durch wegfliegende Teile! Wegfliegende Bruchstücke oder Gegenstände können Personen oder Tiere verletzen. Den Wasserstrahl nie auf zerbrechliche oder lose Gegenstände richten.
–Unfallgefahr infolge Beschädigung! Reifen und Ventile mit einem Mindestabstand von 30 cm reinigen.
6 |
DE |
Warnung
–Asbesthaltige Materialien,
–Materialien, die möglicherweise gesundheitsgefährdende Stoffe enthalten.
Gefahr
–Verletzungsgefahr durch austretenden, eventuell heißen Wasserstrahl! Nur Original Kärcher-Hochdruckschläuche sind optimal auf die Anlage abgestimmt. Bei Verwendung anderer Schläuche wird keine Gewähr übernommen.
–Gesundheitsgefahr durch Reinigungsmittel! Durch gegebenenfalls beigemischte Reinigungsmittel besitzt das vom Gerät abgegebene Wasser keine Trinkwasserqualität.
–Gefahr von Gehörschäden durch Arbeiten an geräuschverstärkenden Teilen! In diesem Fall Gehörschutz tragen.
Gefahr
Gefahr
|
-4
Hebel der Handspritzpistole ziehen und den Geräteschalter
(A) auf „1“ (Motor ein) stellen.
Gefahr
Gefahr
Zur Umrüstung von Heißwasserauf Dampfstufenbetrieb ist das Gerät kaltzufahren und auszuschalten. Die Umrüstung ist wie folgt durchzuführen:
Bestell-Nr. |
Typ |
4.766-023 |
HDS 9/14 |
4.766-024 |
HDS 12/14 |
–Wird während des Betriebes der Hebel der Handspritzpistole losgelassen, schaltet das Gerät ab.
–Beim erneuten Öffnen der Pistole innerhalb der einstellbaren Betriebsbereitschaftszeit (2…8 Minuten) läuft das Gerät selbsttätig wieder an.
–Wird die Betriebsbereitschaftszeit überschritten, schaltet die Sicherheitszeitschaltung Pumpe und Brenner ab. Die Kontrolllampe Betriebsbereitschaft (F) erlischt.
–Zur Wiederinbetriebnahme den Geräteschalter auf Stellung „0“ stellen, dann wieder einschalten. Wird das Gerät mit einer Fernbedienung gesteuert, kann die Wiederinbetriebnahme am entsprechenden Schalter der Fernbedienung ausgeführt werden.
–Fahrzeugreifen werden nur mit der Flachstrahldüse (25°) und einem Mindest-Spritzabstand von 30 cm gereinigt. Mit dem Rundstrahl dürfen Reifen auf keinen Fall gereinigt werden.
Ver- |
Düse |
Spritz- |
Teile-Nr. |
Druck |
Rück- |
schmut- |
|
winkel |
6.415 |
[MPa] |
stoß [N] |
zung |
|
|
|
|
|
|
|
|
|
|
|
|
|
HDS |
9/14 |
|
|
stark |
00060 |
0° |
-257 |
14 |
44 |
mittel |
25060 |
25° |
-295 |
|
|
leicht |
40060 |
40° |
-301 |
|
|
|
|
HDS |
12/14 |
|
|
stark |
00080 |
0° |
-150 |
14 |
55 |
mittel |
25080 |
25° |
-152 |
|
|
leicht |
40080 |
40° |
-153 |
|
|
Ver- |
Düse |
Spritz- |
Teile-Nr. |
Druck |
Rück- |
schmut- |
|
winkel |
6.415 |
[MPa] |
stoß [N] |
zung |
|
|
|
|
|
|
|
|
|
|
|
|
|
HDS |
9/14 |
|
|
stark |
0075 |
0° |
-419 |
10 |
37 |
mittel |
2575 |
25° |
-421 |
|
|
leicht |
4075 |
40° |
-422 |
|
|
|
|
HDS |
12/14 |
|
|
stark |
0010 |
0° |
-082 |
10 |
46 |
mittel |
2510 |
25° |
-252 |
|
|
leicht |
4010 |
40° |
-253 |
|
|
DE - 5 |
7 |
–Reinigungsmittel erleichtern die Reinigungsaufgabe. Sie werden aus einem externen Reinigungsmitteltank angesaugt.
–Das Gerät ist in der Grundausstattung mit einem Dosierventil
(C) ausgestattet. Eine zweite Dosiereinrichtung (Dosierventil D) ist als Sonderzubehör erhältlich. Dann besteht die Möglichkeit, zwei verschiedene Reinigungsmittel anzusaugen.
–Die Dosiermenge wird an den Reinigungsmittel-Dosierventi- len (C oder D) am Bedienfeld eingestellt. Der eingestellte Wert entspricht dem Reinigungsmittelanteil in Prozent.
–Die äußere Skala gilt bei Verwendung von unverdünntem Reinigungsmittel (100 % CHEM).
–Die innere Skala gilt bei Verwendung von 1+3 vorverdünntem Reinigungsmittel (25 % CHEM + 75 % Wasser).
HDS 9/14 |
|
|
|
Stellung |
0,5 |
1 |
5 |
Reinigungsmittelmenge [l/h] |
14...15 22...24 |
50 |
|
Reinigungsmittelkonzentration [%] |
1,5 |
2,5 |
5 |
HDS 12/14 |
|
|
|
Stellung |
0,5 |
1 |
5 |
Reinigungsmittelmenge [l/h] |
10...13 |
23...27 |
60 |
Reinigungsmittelkonzentration [%] |
1 |
2 |
5 |
–Viskosität des Reinigungsmittels
–Ansaughöhe
–Strömungswiderstand der Hochdruckleitung
Enthärterbehälter mit Enthärterflüssigkeit RM 110 (2.780001) nachfüllen.
Gefahr
Hauptschalter abschalten und sichern bzw. Cekon-Stecker ausstecken.
Verletzungsund Beschädigungsgefahr! Gewicht des Gerätes bei Lagerung beachten.
Verletzungsund Beschädigungsgefahr! Gewicht des Gerätes beim Transport beachten.
8 |
DE - 6 |
|
|
HDS 9/14 |
HDS 12/14 |
HDS 12/14 |
|
|
|
|
|
|
|
1.698-900 |
1.699-919 |
1.699-920 |
|
|
|
|
|
Leistungsdaten |
|
|
|
|
|
|
|
|
|
Arbeitsdruck Wasser (mit Standarddüse) |
MPa (bar) |
14 (140) |
14 (140) |
14 (140) |
|
|
|
|
|
Max. Arbeitsdruck Dampfbetrieb (mit Dampfdüse) |
MPa (bar) |
3,2 (32) |
3,2 (32) |
3,2 (32) |
|
|
|
|
|
Teile-Nr. Dampfdüse |
-- |
4.766-023 |
4.766-024 |
4.766-024 |
|
|
|
|
|
Max. Betriebsüberdruck (Sicherheitsventil) |
MPa (bar) |
18,5 (185) |
18,5 (185) |
18,5 (185) |
|
|
|
|
|
Fördermenge Wasser (stufenlos regelbar) |
l/h (l/min) |
500-930 |
600-1200 |
600-1200 |
|
|
(8,3-15,5) |
(10-20) |
(10-20) |
|
|
|
|
|
Fördermenge Dampfbetrieb |
l/h (l/min) |
470 (7,8) |
600 (10) |
600 (10) |
|
|
|
|
|
Reinigungsmittelansaugung (stufenlos regelbar) |
l/h (l/min) |
0-50 (0-0,8) |
0-60 (0-1) |
0-60 (0-1) |
|
|
|
|
|
Wasseranschluss |
|
|
|
|
|
|
|
|
|
Zulaufmenge (min.) |
l/h (l/min) |
1100 (18,3) |
1300 (21,7) |
1300 (21,7) |
|
|
|
|
|
Zulaufdruck (min.) |
MPa (bar) |
0,1 (1) |
0,1 (1) |
0,1 (1) |
|
|
|
|
|
Zulaufdruck (max.) |
MPa (bar) |
0,6 (6) |
0,6 (6) |
0,6 (6) |
|
|
|
|
|
Elektrischer Anschluss |
|
|
|
|
|
|
|
|
|
Stromart |
-- |
3N~ |
3N~ |
3N~ |
|
|
|
|
|
Frequenz |
Hz |
50 |
50 |
50 |
|
|
|
|
|
Spannung |
V |
400 |
400 |
230 |
|
|
|
|
|
Anschlussleistung |
kW |
6,4 |
7,5 |
8,2 |
|
|
|
|
|
Elektrische Absicherung (träge) |
A |
16 |
20 |
32 |
|
|
|
|
|
Schutzart |
-- |
IPX5 |
IPX5 |
IPX5 |
|
|
|
|
|
Schutzklasse |
-- |
I |
I |
I |
|
|
|
|
|
Maximal zulässige Netzimpedanz |
Ohm |
(0,381+j 0,238) |
-- |
-- |
|
|
|
|
|
Elektrozuleitung |
mm2 |
5 x 2,5 |
5 x 2,5 |
5 x 4 |
Temperatur |
|
|
|
|
|
|
|
|
|
Zulauftemperatur (max.) |
°C |
30 |
30 |
30 |
|
|
|
|
|
Max. Arbeitstemperatur Heißwasser |
°C |
98 |
98 |
98 |
|
|
|
|
|
Max. Arbeitstemperatur Dampfbetrieb |
°C |
155 |
155 |
155 |
|
|
|
|
|
Temperaturerhöhung bei max. Wasserdurchsatz |
°C |
56±2 |
54±2 |
54±2 |
|
|
|
|
|
Heizleistung brutto |
kW |
68 |
85 |
85 |
|
|
|
|
|
Brennstoffverbrauch |
kg/h |
5,8 |
7,1 |
7,1 |
|
|
|
|
|
Kaminzug |
kPa |
0,01-0,04 |
0,01-0,04 |
0,01-0,04 |
|
|
|
|
|
Abgasmassenstrom - Volllast |
kg/h |
124 |
155 |
155 |
|
|
|
|
|
Maße und Gewichte |
|
|
|
|
|
|
|
|
|
Länge |
mm |
1124 |
1124 |
1124 |
|
|
|
|
|
Breite |
mm |
558 |
558 |
558 |
|
|
|
|
|
Höhe |
mm |
687 |
699 |
699 |
|
|
|
|
|
Typisches Betriebsgewicht |
kg |
164,4 |
178,8 |
178,8 |
|
|
|
|
|
Ermittelte Werte gemäß EN 60335-2-79 |
|
|
|
|
|
|
|
|
|
Geräuschemission |
|
|
|
|
|
|
|
|
|
Schalldruckpegel LpA |
dB(A) |
74 |
76 |
76 |
Unsicherheit KpA |
dB(A) |
1 |
1 |
1 |
Hand-Arm Vibrationswert |
|
|
|
|
|
|
|
|
|
Handspritzpistole |
m/s2 |
2,2 |
2,3 |
2,3 |
Strahlrohr |
m/s2 |
1,8 |
2,1 |
2,1 |
Unsicherheit K |
m/s2 |
1,0 |
1,0 |
1,0 |
DE - 7 |
9 |
|
|
Maßblatt |
|
|
|
687/699 |
|
505 |
|
|
|
200 |
|
|
|
|
300 |
|
|
|
|
1018±2 |
|
|
246 |
158 |
|
61 |
141 |
558 |
|
|
|
|
47 |
|
|
46 |
|
|
|
|
77 |
|
|
|
1060 |
|
|
|
|
|
1124 |
|
10 |
|
DE |
- 8 |
|
Gefahr
Verletzungsgefahr! Vor allen Wartungsund Reparaturarbeiten ist der Hauptschalter auszuschalten bzw. der Cekon-Stecker auszustecken.
Zeitpunkt |
Tätigkeit |
betroffene Baugruppe |
Durchführung |
von wem |
täglich |
Handspritzpisto- |
Handspritzpistole |
Überprüfen, ob Handspritzpistole dicht schließt. |
Bediener |
|
le prüfen |
|
Funktion der Sicherung gegen unbeabsichtigte |
|
|
|
|
Bedienung prüfen. Defekte Handspritzpistolen |
|
|
|
|
austauschen. |
|
|
|
|
|
|
|
Hochdruck- |
Ausgangsleitungen, Schläuche |
Schläuche auf Beschädigung untersuchen. Defekte |
Bediener |
|
Schläuche prüfen |
zum Arbeitsgerät |
Schläuche sofort auswechseln. Unfallgefahr! |
|
|
|
|
|
|
|
Anschlusslei- |
Elektrischer Anschluss mit Ste- |
Anschlussleitung mit Netzstecker auf Schäden |
Bediener |
|
tung mit Netzste- |
cker/Steckdose |
prüfen. Beschädigte Anschlussleitung unverzüg- |
|
|
cker prüfen |
|
lich durch autorisierten Kundendienst/Elektro- |
|
|
|
|
Fachkraft austauschen lassen. |
|
|
|
|
|
|
wöchentlich oder |
Ölzustand prüfen |
Ölbehälter an der Pumpe |
Ist das Öl milchig, muss es gewechselt werden. |
Bediener |
nach 40 Betriebs- |
|
|
|
|
Ölstand überprü- |
Ölbehälter an der Pumpe |
Ölstand der Pumpe überprüfen. Bei Bedarf Öl |
Bediener |
|
stunden |
fen |
|
(Best.-Nr. 6.288-016) nachfüllen. |
|
|
|
|
|
|
|
Sieb reinigen |
Sieb im Wassereingang |
Siehe Abschnitt „Siebe reinigen“. |
Bediener |
monatlich oder |
Zündelektroden |
Zündelektroden im Deckel des |
Brennstoffleitung abschrauben, Elektrodenhalter |
Bediener mit |
nach 200 Be- |
reinigen und |
Durchlauferhitzers |
ausbauen und Elektroden reinigen. Elektroden- |
Einweisung |
triebsstunden |
überprüfen |
|
einstellung nach der Skizze auf der folgenden |
|
|
|
|
Seite überprüfen und bei Bedarf einstellen. |
|
|
|
|
|
|
|
Pumpe prüfen |
Hochdruckpumpe |
Pumpe auf Undichtigkeit untersuchen. Bei mehr |
Bediener |
|
|
|
als 3 Tropfen pro Minute Kundendienst rufen. |
|
|
|
|
|
|
|
auf innere Abla- |
gesamte Anlage |
Anlage mit Strahlrohr ohne Hochdruck-Düse in |
Bediener mit |
|
gerungen prüfen |
|
Betrieb nehmen. Steigt der Betriebsdruck am |
Einweisung |
|
|
|
Gerätemanometer über 3 MPa an, so muss die |
für Entkalkung |
|
|
|
Anlage entkalkt werden. Dasselbe gilt auch, |
|
|
|
|
wenn beim Betrieb ohne Hochdruckleitung |
|
|
|
|
(Wasser tritt am Hochdruckausgang frei aus) ein |
|
|
|
|
Betriebsdruck von mehr als 0,7–1 MPa festge- |
|
|
|
|
stellt wird. |
|
|
|
|
|
|
|
Sieb reinigen |
Sieb in der Wassermangelsi- |
Siehe Abschnitt „Siebe reinigen“. |
Bediener |
|
|
cherung |
|
|
|
|
|
|
|
halbjährlich oder |
Ölwechsel |
Hochdruckpumpe |
Öl ablassen. 1 l neues Öl (Best.-Nr. 6.288-016) |
Bediener |
nach 1000 Be- |
|
|
einfüllen. Füllstand am Ölbehälter kontrollieren. |
|
triebsstunden |
|
|
|
|
prüfen, reinigen |
gesamte Anlage |
Sichtkontrolle der Anlage, Hochdruckanschlüsse |
Kunden- |
|
|
|
|
auf Dichtheit prüfen, Überströmventil auf Dicht- |
dienst |
|
|
|
heit prüfen, Hochdruckschlauch prüfen, Druck- |
|
|
|
|
speicher prüfen, Brennstofffilter reinigen / |
|
|
|
|
erneuern, Heizschlange entrußen / entkalken, |
|
|
|
|
Zündelektroden reinigen / erneuern, Brennerdü- |
|
|
|
|
se reinigen / erneuern, Brenner einstellen. |
|
|
|
|
|
|
jährlich |
Sicherheitsüber- |
gesamte Anlage |
Sicherheitsüberprüfung nach den jeweiligen na- |
Sachkundiger |
|
prüfung |
|
tionalen Vorschriften des Gesetzgebers für Flüs- |
|
|
|
|
sigkeitsstrahler durchführen. |
|
|
|
|
|
|
spätestens alle 5 |
Druckprüfung |
gesamte Anlage |
Druckprüfung gemäß Herstellervorgabe durch- |
Sachkundiger |
Jahre wiederkeh- |
|
|
führen. |
|
rend |
|
|
|
|
|
|
|
|
|
DE - 9 |
11 |
2. 1.
|
A |
B |
C |
|
|
|
A |
B |
C |
a |
HDS 9/14 |
4,5±0,5 |
3,5±0,5 |
3+0,5 |
60° |
HDS 12/14 |
3,5±0,5 |
3,5±0,5 |
3+0,5 |
60° |
Gefahr
Gefahr
–RM 100 (Best.-Nr. 6.287-008) löst Kalkstein und einfache Verbindungen aus Kalkstein und Waschmittelrückständen.
–RM 101 (Best.-Nr. 6.287-013) löst Ablagerungen, die mit RM 100 nicht ablösbar sind.
Einen 20-Liter-Behälter mit 15 l Wasser füllen.
Auffangbehälter unter den Hochdruck-Ausgang stellen.
12 |
DE - 10 |
Gefahr
Verletzungsgefahr! Vor allen Wartungsund Reparaturarbeiten ist der Hauptschalter auszuschalten bzw. der Cekon-Stecker auszustecken.
Störung |
Mögliche Ursache |
Behebung |
von wem |
|
|
|
|
|
|
Gerät läuft nicht, Kontroll- |
Keine Spannung am Gerät vor- |
Elektrisches Netz überprüfen. |
Elektriker |
|
lampe Betriebsbereitschaft |
handen. |
|
|
|
(F) leuchtet nicht |
|
|
|
|
Sicherheitszeitschaltung in Funktion. |
Gerät am Geräteschalter kurz aus-, dann |
Bediener |
||
|
||||
|
|
wieder einschalten. |
|
|
|
|
|
|
|
|
Sicherung im Steuerkreis (F3) |
Neue Sicherung einsetzen, bei Wiederdurch- |
Kundendienst |
|
|
durchgebrannt. Sicherung ist im |
brennen Überlastungsgrund beseitigen. |
|
|
|
Steuertrafo (T2) enthalten. |
|
|
|
|
|
|
|
|
|
Druckschalter HD (Hochdruck) |
Druckschalter prüfen. |
Kundendienst |
|
|
oder ND (Niederdruck) defekt. |
|
|
|
|
|
|
|
|
|
Timer Modul (A1) defekt. |
Anschlüsse überprüfen, bei Bedarf austau- |
Kundendienst |
|
|
|
schen. |
|
|
|
|
|
|
|
|
Abgasthermostat (B8) hat ausge- |
Anlage abkühlen lassen. Abgasthermostat |
Kundendienst |
|
|
löst. |
(B8) entriegeln. Ursache der Störung besei- |
|
|
|
|
tigen. |
|
|
|
|
|
|
|
+ Kontrolllampe Motorüber- |
Thermofühler (WS) im Motor oder |
Überlastungsgrund beseitigen. |
Kundendienst |
|
hitzung (G) leuchtet |
Überstromschutzschalter (F1) hat |
|
|
|
|
ausgelöst. |
|
|
|
|
|
|
|
|
|
Wassermangelsicherung im |
Wassermangel beseitigen. |
Bediener |
|
|
Schwimmerbehälter hat ange- |
|
|
|
|
sprochen. |
|
|
|
|
|
|
|
|
Brenner zündet nicht oder |
Temperaturregler (B) zu niedrig |
Temperaturregler höher einstellen. |
Bediener |
|
Flamme erlischt während |
eingestellt. |
|
|
|
des Betriebes |
|
|
|
|
Geräteschalter steht nicht auf |
Brenner einschalten. |
Bediener |
||
|
||||
|
Brenner. |
|
|
|
|
|
|
|
|
|
Wassermangelsicherung des Si- |
Ausreichende Wasserzufuhr sicherstellen. |
Bediener |
|
|
cherheitsblocks hat abgeschaltet. |
Gerät auf Dichtheit überprüfen. |
|
|
|
|
|
|
|
Kontrolllampe Brennerstö- |
Brennstoffbehälter leer. |
Brennstoff auffüllen. |
Bediener |
|
rung (E) leuchtet auf * |
|
|
|
|
Brennstofffilter verstopft. |
Brennstofffilter reinigen, dazu Brennstofffil- |
Bediener |
||
|
||||
|
|
ter herausdrehen, reinigen und wieder ein- |
|
|
|
|
drehen. |
|
|
|
|
|
|
|
|
Fotozelle Flammüberwachung |
Korrekten Sitz der Fotozelle prüfen. ** |
Bediener |
|
|
falsch ausgerichtet oder defekt. |
|
|
|
|
|
|
|
|
|
Kein Zündfunke vorhanden |
Elektrodenabstand Zündtransformator und |
Kundendienst |
|
|
(durch Schauglas im Brennerde- |
Zündkabel überprüfen. Abstand berichtigen |
|
|
|
ckel feststellbar). |
oder defekte Teile austauschen. Falls erfor- |
|
|
|
|
derlich säubern. |
|
|
|
|
|
|
|
|
Brennermotor ist blockiert. |
Blockierung beheben. Stopfen (I) am Be- |
Kundendienst |
|
|
|
dienfeld entfernen und Überstromschutz- |
|
|
|
|
schalter entriegeln. Stopfen wieder |
|
|
|
|
einsetzen. |
|
Störung an Brennstoffpumpe oder |
Teile prüfen und defekte Teile austauschen. |
Bediener |
Brennstoffmagnetventil. |
|
|
* |
** |
|
Hinweis |
|
|
Anlage ausund einschalten, um die Brennerstörung zu entriegeln. |
|
|
DE - 11 |
13 |
Störung |
Mögliche Ursache |
Behebung |
von wem |
|
Kontrolllampe Verkalkungs- |
Enthärter verbraucht. |
Enthärter nachfüllen. |
Bediener |
|
schutz (H) leuchtet |
|
|
|
|
|
|
|
|
|
Ungenügende oder keine |
Dosierventil auf Stellung „0“. |
Reinigungsmittel-Dosierventil einstellen. |
Bediener |
|
Reinigungsmittelförderung |
|
|
|
|
Reinigungsmittelfilter verstopft |
Säubern bzw. füllen. |
Bediener |
||
|
oder Tank leer. |
|
|
|
|
Reinigungsmittel-Saugschläuche, |
Prüfen, reinigen. |
Bediener |
|
|
-Dosierventil oder -Magnetventil |
|
|
|
|
undicht oder verstopft. |
|
|
|
|
|
|
|
|
|
Elektronik oder Magnetventil defekt. |
Austauschen |
Kundendienst |
|
Gerät kommt nicht auf vollen |
Düse ausgespült. |
Düse ersetzen. |
Bediener |
|
Druck |
|
|
|
|
Reinigungsmitteltank leer. |
Reinigungsmittel nachfüllen. |
Bediener |
||
|
Nicht genügend Wasser. |
Für ausreichende Wasserzufuhr sorgen. |
Bediener |
|
|
Sieb am Wassereingang verstopft. |
Prüfen, Sieb ausbauen und reinigen. |
Bediener |
|
|
Reinigungsmitteldosierventil undicht. |
Prüfen und abdichten. |
Bediener |
|
|
Reinigungsmittelschläuche undicht. |
Austauschen |
Bediener |
|
|
Schwimmerventil klemmt. |
Auf Gängigkeit überprüfen. |
Bediener |
|
|
Sicherheitsventil undicht. |
Einstellung prüfen, bei Bedarf neue Dichtung |
Kundendienst |
|
|
|
einbauen. |
|
|
|
|
|
|
|
|
Mengenregulierventil undicht oder |
Ventilteile prüfen, bei Beschädigung austau- |
Kundendienst |
|
|
zu niedrig eingestellt. |
schen, bei Verschmutzung reinigen. |
|
|
|
|
|
|
|
|
Magnetventil für Druckentlastung |
Magnetventil austauschen. |
Kundendienst |
|
|
defekt. |
|
|
|
|
|
|
|
|
Hochdruckpumpe klopft, Ma- |
Schwingungsdämpfer defekt. |
Schwingungsdämpfer austauschen. |
Kundendienst |
|
nometer schwingt stark |
|
|
|
|
Wasserpumpe saugt geringfügig |
Saugsystem überprüfen und Undichtheit be- |
Bediener |
||
|
Luft an. |
heben. |
|
|
|
|
|
|
|
Gerät schaltet bei geöffneter |
Düse im Strahlrohr verstopft. |
Prüfen, reinigen. |
Bediener |
|
Handspritzpistole laufend |
|
|
|
|
Gerät ist verkalkt. |
Siehe Abschnitt „Entkalken“. |
Bediener |
||
aus/ein |
|
|
|
|
Schaltpunkt des Überströmers hat |
Überströmer neu einstellen lassen. |
Kundendienst |
||
|
||||
|
sich verstellt. |
|
|
|
|
|
|
|
|
|
Sieb in der Wassermangelsiche- |
Prüfen, Sieb ausbauen und reinigen. |
Bediener |
|
|
rung verstopft. |
|
|
|
|
|
|
|
|
Gerät schaltet bei geschlos- |
Pumpe ist nicht vollständig entlüftet. |
Geräteschalter auf „0“ stellen und |
Bediener |
|
sener Handspritzpistole nicht |
|
Handspritzpistole ziehen, bis keine Flüssig- |
|
|
aus |
|
keit aus der Düse austritt. Dann Gerät wieder |
|
|
|
|
einschalten. Diesen Vorgang wiederholen, |
|
|
|
|
bis der volle Betriebsdruck erreicht ist. |
|
|
|
|
|
|
|
|
Sicherheitsventil bzw. Sicherheits- |
Sicherheitsventil bzw. Dichtung ersetzen. |
Kundendienst |
|
|
ventildichtung defekt. |
|
|
|
|
|
|
|
14 |
DE - 12 |
Anwendungsbereich |
Verschmutzung, Anwendungsart |
Reinigungsmittel |
pH-Wert (ca.) 1 %-ige |
|
|
|
|
|
Lösung in Leitungs- |
|
|
|
|
wasser |
Kfz-Gewerbe, Tankstel- |
Staub, Straßenschmutz, Mineral- |
RM 55 |
ASF ** |
8 |
len, Spedition, Fuhrparks |
öle (auf lackierten Flächen) |
|
|
|
RM 22/80-Pulver ASF |
12/10 |
|||
|
|
RM 81 ASF |
9 |
|
|
|
RM 803 ASF |
10 |
|
|
|
RM 806 ASF |
11 |
|
|
Fahrzeugkonservierung |
RM 42 |
Kaltwachs für Hochdruck-Reiniger |
8 |
|
|
RM 820-Heißwachs ASF |
7 |
|
|
|
RM 821-Sprühwachs ASF |
6 |
|
|
|
RM 824-Super-Perlwachs ASF |
7 |
|
|
|
RM 44 |
Gel-Felgenreiniger |
9 |
Metallverarbeitende In- |
Öle, Fette, Staub und ähnliche |
RM 22-Pulver ASF |
12 |
|
dustrie |
Verschmutzungen |
|
|
|
RM 55 |
ASF |
8 |
||
|
|
RM 81 ASF |
9 |
|
|
|
RM 803 ASF |
10 |
|
|
|
RM 806 ASF |
12 |
|
|
|
RM 31 |
ASF (starke Verschmutzung) |
12 |
|
|
RM 39-flüssig (mit Korrosionsschutz) |
9 |
|
Lebensmittelverarbeiten- |
Leichte bis mittlere Verschmutzun- |
RM 55 |
ASF |
8 |
de Betriebe |
gen, Fette/Öle, Großflächen |
|
|
|
RM 81 |
ASF |
9 |
||
|
|
RM 882 Gelschaum OSC |
12 |
|
|
|
RM 58 |
ASF (Schaumreinigungsmittel) |
9 |
|
|
RM 31 ASF * |
12 |
|
|
Rauchharz |
RM 33 |
* |
13 |
|
Reinigung und Desinfektion |
RM 732 |
9 |
|
|
Desinfektion |
RM 735 |
7...8 |
|
|
Kalk, mineralische Ablagerungen |
RM 25 |
ASF * |
2 |
|
|
RM 59 |
ASF (Schaumreinigung) |
2 |
Sanitärbereich *** |
Kalk, Urinstein, Seifen etc. |
RM 25 |
ASF * (Grundreinigung) |
2 |
|
|
RM 59 |
ASF (Schaumreinigung) |
2 |
|
|
RM 68 ASF |
5 |
*= nur für kurzen Einsatz, Zweischrittmethode, mit Klarwasser nachspülen
**= ASF = abscheidefreundlich
***= zum Vorsprühen eignet sich Foam-Star 2000
DE - 13 |
15 |
!
–Die Heizeinrichtung des Gerätes ist eine Feuerungsanlage. Bei der Aufstellung sind die örtlich geltenden Vorschriften zu beachten.
–Nur geprüfte Schornsteine/Abgasleitungen verwenden.
Gefahr
Vorzusehen ist ein 2-Strang-System, Vorund Rücklauf.
–Maximaler Heizölvordruck: 0,05 MPa (0,5 bar)
–Maximaler Unterdruck zwischen Heizölfilter und Pumpe: 0,04 MPa (0,4 bar)
–Jedes Gerät muss an einen eigenen Kamin angeschlossen werden.
–Die Abgasführung ist entsprechend der örtlichen Vorschriften und in Abstimmung mit dem zuständigen Schornsteinfegermeister auszuführen.
–Vor der Montage ist die Wand auf Tragfähigkeit hin zu prüfen. Das mitgelieferte Befestigungsmaterial ist für Beton geeignet. Für Hohlraumbaustein-, Ziegelbausteinund Gasbetonwände sind geeignete Dübel und Schrauben zu verwenden, z. B. Injektionsanker (Bohrbild siehe Maßblatt).
–Bild 3 - Pos. 19 und 23
Das Gerät darf nicht starr mit dem Wasserleitungsoder dem Hochdruckrohrleitungsnetz verbunden werden. Die Verbindungsschläuche sind unbedingt zu montieren.
–Bild 3 - A
–Der Druckabfall in der Rohrleitung muss unter 1,5 MPa liegen.
–Die fertige Rohrleitung muss mit 28 MPa geprüft werden.
–Die Isolation der Rohrleitung muss bis 155 °C temperaturbeständig sein.
–Die Leistung der Wasserversorgung muss mindestens 1300 l/h bei mindestens 0,1 MPa betragen.
–Die Wassertemperatur muss unter 30 °C liegen.
Die maximal zulässige Netzimpedanz am elektrischen Anschlusspunkt (siehe Technische Daten) darf nicht überschritten werden. Bei Unklarheiten bezüglich der an Ihrem Anschlusspunkt vorliegenden Netzimpedanz setzen Sie sich bitte mit Ihrem Energieversorgungsunternehmen in Verbindung.
–Anschlusswerte siehe Technische Daten und Typenschild.
–Der elektrische Anschluss muss von einem Elektroinstallateur ausgeführt werden und IEC 60364-1 entsprechen.
–Stromführende Teile, Kabel und Geräte im Arbeitsbereich müssen in einwandfreiem Zustand strahlwassergeschützt sein.
16 |
DE - 14 |
Cekon-Stecker an Anschlusskabel des Gerätes montieren.
Cekon-Stecker in Steckdose stecken.
Gefahr
a b c d
Düsenmundstück (b) mit Überwurfmutter (a) am Strahlrohr
(d) befestigen. Darauf achten, dass der Dichtring (c) sauber in der Nut liegt.
b
c
a
Gefahr
–Über das örtliche Versorgungsunternehmen,
a
Wasserhärte (°dH) |
5 |
10 |
15 |
20 |
25 |
Skala am Drehpotentiometer |
8 |
7 |
6 |
5 |
4,5 |
Pausenzeit (Sekunden) |
50 |
40 |
31 |
22 |
16 |
|
S2 |
8 7 6 5 4 3 2 1 |
|
min. |
max. |
Behälter mit Kärcher-Enthärterflüssigkeit RM 110 (Best.-Nr. 2.780-001) füllen.
DE - 15 |
17 |
|
|
|
|
|
|
Installationsmaterial |
|
|
|
|
|
||
1 |
|
2 |
3 |
4 |
5 |
6 |
7 |
8 |
|
9 |
10 |
12 |
13 |
24 |
|
|
|
|
|
|
A |
|
|
|
|
|
|
11a |
11b |
|
|
|
|
|
|
|
11b |
|
11a |
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
11d |
|
|
|
||
23 |
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
B |
19a |
|
|
|
|
|
|
22 |
|
|
|
|
|
|
|
|
|
|
11c |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
600 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
21 |
|
|
20 |
19 |
18 |
17 |
16 |
15 |
14 |
|
~1050 |
1060 (1124) |
|
|
|
|
|
|
|
|
|
Bild 3 |
|
|
|
|
|
Pos. |
Installationsmaterial |
Bestell-Nr. |
1 |
Winkelverschraubung |
6.386-356 |
2 |
Rauchgasrohrkrümmer 90° |
7.234-605 |
|
Rauchgasrohrkrümmer 45° |
7.234-604 |
3 |
Rauchgasrohr |
7.234-603 |
4 |
Zugunterbrecher Rauchgasrohr HDS 9/ |
4.656-080 |
|
14-4 |
|
|
Zugunterbrecher Rauchgasrohr HDS 12/ |
4.656-079 |
|
14-4 |
|
5 |
Wärmeisolation |
6.286-114 |
6 |
Hauptschalter |
6.631-455 |
7 |
Rohrleitungssatz, Stahl verzinkt |
2.420-004 |
|
Rohrleitungssatz, Edelstahl |
2.420-006 |
8 |
Teilesatz Fernsteuerung |
2.744-008 |
9 |
Teilesatz Not-Aus-Schalter |
2.744-002 |
10 |
T-Verschraubung |
6.386-269 |
11a |
Anschlussstutzen, Messing |
2.638-180 |
|
Anschlussstutzen, Edelstahl |
2.638-181 |
11b |
Absperrhahn NW 8, Stahl verzinkt |
4.580-144 |
|
Absperrhahn NW 8, Edelstahl |
4.580-163 |
11c |
Schnellkupplungsfestteil |
6.463-025 |
11d |
Schnellkupplungslosteil |
6.463-023 |
Pos. |
Installationsmaterial |
Bestell-Nr. |
12 |
Schlauchhalter |
2.042-001 |
13 |
Schlauchtrommel |
2.637-238 |
14 |
Hochdruckschlauch 10 m |
6.388-083 |
15 |
Handspritzpistole Easypress |
4.775-463 |
|
Drehregler HDS 9/14-4 |
4.775-470 |
|
Drehregler HDS 12/14-4 |
4.775-471 |
16 |
Strahlrohrhalter |
2.042-002 |
17 |
Strahlrohr |
4.760-550 |
18 |
Düsenmundstück HDS 9/14-4 |
2.883-402 |
|
Düsenmundstück HDS 12/14-4 |
2.883-406 |
19 |
Wasserschlauch |
4.440-282 |
19a |
Magnetventil Wasserzulauf |
4.743-011 |
20 |
Reinigungsmittel-Tank, 60 l |
5.070-078 |
21 |
Heizöl-Tank 600 l |
6.392-050 |
22 |
Teilesatz Wandkonsole |
2.053-005 |
|
Teilesatz Bodengestell |
2.210-008 |
23 |
Hochdruckschlauch |
6.389-028 |
24 |
Rohrschelle |
6.373-374 |
18 |
DE - 16 |
|
EG-Konformitätserklärung |
|
Garantie |
Hiermit erklären wir, dass die nachfolgend bezeichnete Maschine |
|
In jedem Land gelten die von unserer zuständigen Vertriebs-Ge- |
|
aufgrund ihrer Konzipierung und Bauart sowie in der von uns in |
|
sellschaft herausgegebenen Garantiebedingungen. Etwaige Stö- |
|
Verkehr gebrachten Ausführung den einschlägigen grundlegen- |
|
rungen an dem Gerät beseitigen wir innerhalb der Garantiefrist |
|
den Sicherheitsund Gesundheitsanforderungen der EG-Richtli- |
|
kostenlos, sofern ein Materialoder Herstellungsfehler die Ursa- |
|
nien entspricht. Bei einer nicht mit uns abgestimmten Änderung |
|
che sein sollte. |
|
der Maschine verliert diese Erklärung ihre Gültigkeit. |
|
|
|
Produkt: |
Hochdruckreiniger mit |
|
|
|
Dampfstufe |
|
|
Typ: |
1.698-xxx |
|
|
Typ: |
1.699-xxx |
|
|
97/23/EG
2006/42/EG (+2009/127/EG) 2004/108/EG
II
Konformitätsbewertung Modul H Sicherheitsventil Konformitätsbewertung Art. 3 Abs. 3
EN 55014–1: 2006+A1: 2009+A2: 2011
EN 55014–2: 1997+A1: 2001+A2: 2008
EN 60335–1
EN 60335–2–79
EN 61000–3–2: 2006+A1: 2009+A2: 2009
HDS 12/14:
EN 61000–3–3: 2008
HDS 9/14:
EN 61000–3–11: 2000
Name der benannten Stelle: für 97/23/EG
TÜV Rheinland Industrie Service GmbH Am Grauen Stein
51105 Köln Kenn-Nr. 0035
5.957-054
Die Unterzeichnenden handeln im Auftrag und mit Vollmacht der
Geschäftsführung.
CEO |
Head of Approbation |
Tel.: +49 7195 14-0
Fax: +49 7195 14-2212
DE - 17 |
19 |
Anlagentyp: |
Herstell-Nr.: |
Inbetriebnahme am: |
|
|
|
20 |
DE - 18 |
Prüfung durchgeführt durch: |
Äußere Prüfung |
Innere Prüfung |
Festigkeitsprüfung |
|
|
|
|
|
|
|
|
Name |
Unterschrift der befähigten |
Unterschrift der befähigten |
Unterschrift der befähigten |
|
Person/Datum |
Person/Datum |
Person/Datum |
|
|
|
|
Name |
Unterschrift der befähigten |
Unterschrift der befähigten |
Unterschrift der befähigten |
|
Person/Datum |
Person/Datum |
Person/Datum |
|
|
|
|
Name |
Unterschrift der befähigten |
Unterschrift der befähigten |
Unterschrift der befähigten |
|
Person/Datum |
Person/Datum |
Person/Datum |
|
|
|
|
Name |
Unterschrift der befähigten |
Unterschrift der befähigten |
Unterschrift der befähigten |
|
Person/Datum |
Person/Datum |
Person/Datum |
|
|
|
|
Name |
Unterschrift der befähigten |
Unterschrift der befähigten |
Unterschrift der befähigten |
|
Person/Datum |
Person/Datum |
Person/Datum |
|
|
|
|
Name |
Unterschrift der befähigten |
Unterschrift der befähigten |
Unterschrift der befähigten |
|
Person/Datum |
Person/Datum |
Person/Datum |
|
|
|
|
Name |
Unterschrift der befähigten |
Unterschrift der befähigten |
Unterschrift der befähigten |
|
Person/Datum |
Person/Datum |
Person/Datum |
|
|
|
|
Name |
Unterschrift der befähigten |
Unterschrift der befähigten |
Unterschrift der befähigten |
|
Person/Datum |
Person/Datum |
Person/Datum |
|
|
|
|
Name |
Unterschrift der befähigten |
Unterschrift der befähigten |
Unterschrift der befähigten |
|
Person/Datum |
Person/Datum |
Person/Datum |
|
|
|
|
Name |
Unterschrift der befähigten |
Unterschrift der befähigten |
Unterschrift der befähigten |
|
Person/Datum |
Person/Datum |
Person/Datum |
|
|
|
|
Name |
Unterschrift der befähigten |
Unterschrift der befähigten |
Unterschrift der befähigten |
|
Person/Datum |
Person/Datum |
Person/Datum |
|
|
|
|
DE - 19 |
21 |
Please read and comply with these original instructions prior to the initial operation of your appliance and
store them for later use or subsequent owners.
–Before first start-up it is definitely necessary to read the safety indications Nr. 5.956-309.0!
–In case of transport damage inform vendor immediately
Environmental protection . . |
EN |
. . 1 |
Symbols in the operating instructions |
EN |
. . 1 |
Symbols on the machine. . . |
EN |
. . 1 |
General notes on safety . . . |
EN |
. . 1 |
Proper use. . . . . . . . . . . . . . |
EN |
. . 2 |
Function . . . . . . . . . . . . . . . |
EN |
. . 2 |
Safety Devices . . . . . . . . . . |
EN |
. . 2 |
Device elements . . . . . . . . . |
EN |
. . 3 |
Start up . . . . . . . . . . . . . . . . |
EN |
. . 4 |
Operation . . . . . . . . . . . . . . |
EN |
. . 4 |
Shutting down . . . . . . . . . . . |
EN |
. . 6 |
Shutdown . . . . . . . . . . . . . . |
EN |
. . 6 |
Storage . . . . . . . . . . . . . . . . |
EN |
. . 6 |
Transport. . . . . . . . . . . . . . . |
EN |
. . 6 |
Technical specifications. . . . |
EN |
. . 7 |
Maintenance and care. . . . . |
EN |
. . 9 |
Troubleshooting . . . . . . . . . |
EN |
. 11 |
Accessories. . . . . . . . . . . . . |
EN |
. 13 |
Installing the plant . . . . . . . . |
EN |
. 14 |
EC Declaration of Conformity |
EN |
. 17 |
Warranty . . . . . . . . . . . . . . . |
EN |
. 17 |
Customer Service . . . . . . . . |
EN |
. 18 |
Recurring tests . . . . . . . . . . |
EN |
. 19 |
Symbols in the operating instructions
Danger
Warning
–Please follow the national rules and regulations for fuel spray jets of the respective country.
–Please follow the national rules and regulations for accident prevention of the respective country. Fuel spray jets must be tested regularly and the results of these tests must be documented in writing.
–The heating appliance of the machine is an ignition plant. All national laws and regulations about heating systems must also be followed.
–If the plant is operated in rooms, then there should be adequate measures for safely diverting the exhaust gases out of the room (smoke gas pipes without draught interceptors). Further, there must also be adequate supply of fresh air.
–As per the applicable national guidelines, the first time this high-pressure cleaner must be taken into operation by a skilled person. KÄRCHER has already performed this initial start-up for you and has documented it accordingly. The documentation can be requested at your KÄRCHER partner. Please have the part and plant number of the appliance available when enquiring about the documentation.
–We would like to point out that the appliance must be repeatedly checked by a skilled person as prescribed by the applicable national regulations. Please contact your KÄRCHER partner.
–Please follow the safety instructions which are attached to the used detergents (normally on the packing label).
22 |
EN - 1 |
–The device may only be installed by a specialized company according to the national regulations.
–All national laws and regulations about installation of electrical appliances must also be followed.
–Only Customer Service engineers trained by Kärcher may perform settings and carry out maintenance tasks and repairs.
–The local guidelines must be followed while installing the chimney.
–Wear protective clothing and safety goggles to protect against splash back containing water or dirt.
The machine is used for removing dirt from surfaces using a freeflowing water jet. It is mainly used for cleaning machines, vehicles and facades.
Danger
–Cold water reaches the suction side of the high pressure pump via the engine cooling coil and the swimmer tank. The water softening agent is added in the swimmer tank. The pump transports the water and the sucked detergent through the continuous heater. The proportion of detergent in the water can be adjusted using the dosing valve. The continuous heater is heated by a heater.
–The high pressure outlet is connected to a high pressure network existing in the building. The hand-spray gun is connected to the feeder points of this network using a high pressure hose.
In case of fuel shortage or problems with the burner, the flame monitor switches off the burner. The indicator lamp Burner failure
(E) glows.
EN - 2 |
23 |
1 |
12 |
2
4
6 5
4High-pressure outlet
9 |
11 |
10 |
|
|
|
|
7 |
8 |
3 |
APower switch
BTemperature controller
CDosage valve I for detergent
DDosage valve II for detergent (optional)
EIndicator lamp burner failure
24
F“Ready for use” indicator lamp
GIndicator lamp for engine over-heating
HIndicator lamp for protection against calcification
IStopper - Releaser for burner engine
EN - 3
Danger
–For connection values, see technical data and type plate.
–The electrical connections must be done by an electrician according to IEC 60364-1.
Danger
–Danger of scalding by hot water! Do not direct the water jet on persons or animals.
–Risk of burns on account of hot surfaces! Do not touch uninsulated pipes and hoses when hot water operations are on. Hold the jet pipe only at the handles. Do not touch the exhaust holder of the continuous heater.
–Risk of poisoning or itching on account of detergent! Follow the given instructions for using detergents. Store detergents safely and protect them against access by unauthorised persons.
Danger
–Electrical appliances and plants,
–the unit itself,
–all electricity-carrying parts in the working area.
!
Danger
–Risk of injury! The recoil pressure of the spray pipe can throw you off-balance. You may fall. The spray jet can fly off and cause damage to persons. Search a secure place to stand and hold the gun firmly. Never hold on tightly to the lever of the hand spray gun.
–The jet must not be directed at other persons or directed by the user at him/herself to clean clothing or footwear.
–Risk of injury from parts flying off! Flying-off fragments or objects can injure people or animals. Never direct the water jet on fragile or loose objects.
–Risk of accident on account of damage! Clean tyres and valves from a minimum distance of 30 cm.
Warning
–Materials containing asbestos,
–Materials that could contain substances harmful to health.
Danger
–Risk of injury on account of the emanating water jet that could be hot! Only original Kaercher high pressure hoses are optimally suited for the plant. No guarantee can be given if you use any other hoses.
–Detergents can prove to be a health hazard! If any detergents are added, the water let out of the plant is not of potable quality.
–Risk of hearing impairment while working on noise-making parts! If so, wear ear plugs.
Danger
Danger
Check hose coupling to ensure that it sits firmly and is leak-proof.
Activate hand spray gun until device is pressure-less.
|
Turning the quantity regulation valve in clock-wise direction will result in higher working pressure and larger volume.
Turning the quantity regulation valve in an anti-clockwise direction will result in lower workign pressure and smaller quantities.
EN - 4 |
25 |
Pull the lever of the hand-spray gun and set the appliance switch (A) to "1" (engine on).
The indicator lamp for operational readiness (F) shows that the appliance is in stand-by mode and ready to be operated.
Danger
Danger
Replace the high pressure nozzle with the steam nozzle
(accessory).
Order No. |
Type |
4.766-023 |
HDS 9/14 |
4.766-024 |
HDS 12/14 |
Set the thermostat to 150 °C. |
26 EN
Set the water flow regulation valve of the high pressure pump to minimum water flow (turn in the anti-clockwise direction).
–The appliance will switch off if the lever of the hand-spray gun is released during operations.
–The appliance will automatically start again when you open the gun again within the stand-by period (2 ... 8 minutes).
–If the stand-by period is exceeded, the safety time mechanism switches off the pump and the burner. The indicator lamp Operations Stand-by (F) goes off.
–To restart the appliance, set the appliance switch to "0" and then switch on the appliance again. If the appliance is operated using remote control, the appliance can be restarted by using the corresponding switch of the remote control device.
–Vehicle tyres are only cleaned using the flat spray nozzle ((25°) from a minimum spraying distance of 30 cm. The round spray should never be used to clean tyres.
Dirt |
Nozzle |
Spray an- |
Part no. |
Pressure |
Recoil [N] |
|
|
gle |
6.415 |
[MPa] |
|
|
|
HDS |
9/14 |
|
|
strong |
00060 |
0° |
-257 |
14 |
44 |
medium |
25060 |
25° |
-295 |
|
|
light |
40060 |
40° |
-301 |
|
|
|
|
HDS |
12/14 |
|
|
strong |
00080 |
0° |
-150 |
14 |
55 |
medium |
25080 |
25° |
-152 |
|
|
light |
40080 |
40° |
-153 |
|
|
Dirt |
Nozzle |
Spray an- |
Part no. |
Pressure |
Recoil [N] |
|
|
gle |
6.415 |
[MPa] |
|
|
|
HDS |
9/14 |
|
|
strong |
0075 |
0° |
-419 |
10 |
37 |
medium |
2575 |
25° |
-421 |
|
|
light |
4075 |
40° |
-422 |
|
|
|
|
HDS |
12/14 |
|
|
strong |
0010 |
0° |
-082 |
10 |
46 |
medium |
2510 |
25° |
-252 |
|
|
light |
4010 |
40° |
-253 |
|
|
- 5
–Detergents simplify the cleaning task. They are sucked in from an external detergent tank.
–The basic model of the appliance is equipped with a dosing valve (C). A second dosing device (dosing valve D) can also be procured as special accessory. It is then possible to use two different detergents.
–The dosing quantity is set at the detergent dosing valves (C or D) at the operating panel. The set value corresponds to the percentage share of the detergent.
–The outer scale is applicable while using undiluted detergents (100% CHEM).
–The inner scale is appliance while using 1 +3 pre-diluted detergents (25 % CHEM + 75 % water).
HDS 9/14
Position |
0,5 |
1 |
5 |
Detergent quantity [l/h] |
14...15 |
22...24 |
50 |
Detergent concentration [%] |
1,5 |
2,5 |
5 |
|
|
|
|
HDS 12/14 |
|
|
|
Position |
0,5 |
1 |
5 |
Detergent quantity [l/h] |
10...13 |
23...27 |
60 |
Detergent concentration [%] |
1 |
2 |
5 |
–Viscosity of the detergent
–Suction height
–Flow resistance of the high pressure pipe
Refill the softener tank with softener liquid (RM 110 (2.780001).
Danger
Activate hand spray gun until device is pressure-less.
Flush device with anti-freeze agent.
EN - 6 |
27 |
|
|
HDS 9/14 |
HDS 12/14 |
HDS 12/14 |
|
|
1.698-900 |
1.699-919 |
1.699-920 |
Performance data |
|
|
|
|
Operating pressure of water (using standard nozzle) |
MPa (bar) |
14 (140) |
14 (140) |
14 (140) |
Max. operating pressure for working with steam (using steam |
MPa (bar) |
3,2 (32) |
3,2 (32) |
3,2 (32) |
nozzle) |
|
|
|
|
Part no. of steam nozzle |
-- |
4.766-023 |
4.766-024 |
4.766-024 |
Max. excess operating pressure (safety valve) |
MPa (bar) |
18,5 (185) |
18,5 (185) |
18,5 (185) |
Water flow (can be regulated in a phase-less manner) |
l/h (l/min) |
500-930 |
600-1200 |
600-1200 |
|
|
(8,3-15,5) |
(10-20) |
(10-20) |
Steam flow rate |
l/h (l/min) |
470 (7,8) |
600 (10) |
600 (10) |
Suction of detergent (can be regulated in a phaseless man- |
l/h (l/min) |
0-50 (0-0,8) |
0-60 (0-1) |
0-60 (0-1) |
ner) |
|
|
|
|
Water connection |
|
|
|
|
Min. feed volume |
l/h (l/min) |
1100 (18,3) |
1300 (21,7) |
1300 (21,7) |
Feed pressure (min.) |
MPa (bar) |
0,1 (1) |
0,1 (1) |
0,1 (1) |
Max. feed pressure |
MPa (bar) |
0,6 (6) |
0,6 (6) |
0,6 (6) |
Electrical connection |
|
|
|
|
Current type |
-- |
3N~ |
3N~ |
3N~ |
Frequency |
Hz |
50 |
50 |
50 |
Voltage |
V |
400 |
400 |
230 |
Connected load |
kW |
6,4 |
7,5 |
8,2 |
Electrical protection (slow) |
A |
16 |
20 |
32 |
Type of protection |
-- |
IPX5 |
IPX5 |
IPX5 |
Protective class |
-- |
I |
I |
I |
Maximum allowed net impedance |
Ohm |
(0,381+j 0,238) |
-- |
-- |
Power supply |
mm2 |
5 x 2,5 |
5 x 2,5 |
5 x 4 |
Temperature |
|
|
|
|
Max. feed temperature |
°C |
30 |
30 |
30 |
Max. operating temperature of hot water |
°C |
98 |
98 |
98 |
Max. operating temperature of steam |
°C |
155 |
155 |
155 |
Temperature increase during maximum water flow |
°C |
56±2 |
54±2 |
54±2 |
Gross heating performance |
kW |
68 |
85 |
85 |
Fuel consumption |
kg/h |
5,8 |
7,1 |
7,1 |
Chimney draught |
kPa |
0,01-0,04 |
0,01-0,04 |
0,01-0,04 |
Exhaust flow - full load |
kg/h |
124 |
155 |
155 |
Dimensions and weights |
|
|
|
|
Length |
mm |
1124 |
1124 |
1124 |
Width |
mm |
558 |
558 |
558 |
Height |
mm |
687 |
699 |
699 |
Typical operating weight |
kg |
164,4 |
178,8 |
178,8 |
Values determined as per EN 60355-2-79 |
|
|
|
|
Noise emission |
|
|
|
|
Sound pressure level LpA |
dB(A) |
74 |
76 |
76 |
Uncertainty KpA |
dB(A) |
1 |
1 |
1 |
Hand-arm vibration value |
|
|
|
|
Hand spray gun |
m/s2 |
2,2 |
2,3 |
2,3 |
Spray lance |
m/s2 |
1,8 |
2,1 |
2,1 |
Uncertainty K |
m/s2 |
1,0 |
1,0 |
1,0 |
28 |
EN - 7 |
|
687/699 |
|
505 |
|
|
200 |
|
|
|
|
300 |
|
|
|
|
1018±2 |
|
|
|
246 |
158 |
|
61 |
141 |
558 |
|
|
|
|
47 |
|
|
46 |
|
|
|
|
77 |
|
|
1060 |
|
|
|
|
|
1124 |
|
|
|
EN |
- 8 |
|
29 |
Danger
Time |
Activity |
Assembly affected |
Performance |
of whom |
daily |
Check hand- |
Hand spray gun |
Check whether the hand-spray gun closes tightly |
Operator |
|
spray gun |
|
without any leaks. Check the protection mecha- |
|
|
|
|
nism against accidental switching. Replace de- |
|
|
|
|
fective hand-spray guns. |
|
|
Check high pres- |
Outlets, hoses towards working |
Check hoses to see if there are damages. Re- |
Operator |
|
sure hoses |
machine |
place defect hoses immediately. Danger of acci- |
|
|
|
|
dent! |
|
|
Check the con- |
Electrical connection with plug/ |
Check the connecting line with mains plug for |
Operator |
|
necting line with |
socket |
damages. If the power cord is damaged, please |
|
|
mains plug |
|
arrange immediately for the exchange by an au- |
|
|
|
|
thorized customer service or a skilled electrician. |
|
weekly or after 40 |
Check oil level |
Oil tank at the pump |
If the oil is milky, it needs to be replaced. |
Operator |
operating hours |
|
|
|
|
Check oil level |
Oil tank at the pump |
Check oil level of the pump. Refill oil if required |
Operator |
|
|
|
|
(Order no. 6.288-016) |
|
|
Cleaning the |
Sieve in water inlet |
See section "Clean sieve". |
Operator |
|
sieve |
|
|
|
monthly or after |
Clean and check |
Ignition electrodes located in |
Unscrew the fuel pipe, dismantle the electrode |
Trained op- |
200 operating |
the ignition elec- |
the lid of the continuous heater |
holder and clean the electrodes. Check the elec- |
erator |
hours |
trodes |
|
trode setting according to the diagram on the fol- |
|
|
|
|
lowing page and make the necessary |
|
|
|
|
adjustments. |
|
|
Check pump |
High-pressure pump |
Check the pump for leaks. If the leakage is more |
Operator |
|
|
|
than 3 drops per minute, call Customer Service. |
|
|
Check for inter- |
Entire plant |
Operate the machine using the spray pipe with- |
Operator |
|
nal deposits |
|
out the high pressure nozzle. If the operating |
trained in de- |
|
|
|
pressure on the manometer of the machine in- |
calcification |
|
|
|
creases to more than 3 MPa, then the plant |
|
|
|
|
needs to be decalcified. The same is applicable |
|
|
|
|
when an operating pressure of more than 0.7 - 1 |
|
|
|
|
MPa is detected while operating the machine |
|
|
|
|
without high pressure pipe (water comes out |
|
|
|
|
freely at the high pressure outlet). |
|
|
Cleaning the |
Sieve in the water shortage |
See section "Clean sieve". |
Operator |
|
sieve |
safeguard |
|
|
half-yearly or after |
Oil change |
High-pressure pump |
Drain off oil. Fill in 1 l new oil (Order no. 6.288- |
Operator |
1000 operating |
|
|
016). Check oil level in the oil tank. |
|
hours |
check, clean |
Entire plant |
Visual inspection of the plant, check high pres- |
Customer |
|
|
|
sure connections to see that they are not leaking, |
Service |
|
|
|
check that the over-flow valves are not leaking, |
|
|
|
|
check high pressure hoses, pressure tanks, |
|
|
|
|
clean/ replace fuel filters, remove the rust/ calci- |
|
|
|
|
um deposits from the heating coil, clean/ replace |
|
|
|
|
ignition electrodes, clean/ replace burner nozzle, |
|
|
|
|
adjust burner. |
|
annual |
Safety check |
Entire plant |
Perform a safety inspection as per the applicable |
Technical |
|
|
|
national rules and regulations for liquid spray jets |
expert |
|
|
|
of the respective country. |
|
at least every 5 |
Pressure test |
Entire plant |
Perform the pressure test as per manufacturer's |
Technical |
years, recurring |
|
|
instructions. |
expert |
30 |
EN - 9 |