Dometic MCR9 User Manual

0 (0)
Dometic MCR9 User Manual

SinePower Accessory MCR9

1

Inverter Remote 1

2

Push

On / Off

SinePower Accessory

The remote control MCR9 is suitable to switch on/off the following inverters via the “Remote Port II” (also see the operating manual for the inverter):

• MSI912, MSI1812T

Displays

The red LED (fig. 11) on the front panel displays the following conditions:

Constant glow: The inverter is switched on.

Quick flashing: The inverter is switched on by positive battery voltage.

Slow flashing: The inverter is switched off by positive battery voltage.

Connect

Insert one side of the RJ-11-cable in the socket “To inverter” (Fig. 22).

Insert the other side of the RJ-11-cable into the “Remote Port II” of the inverter.

Switched on/off by an external signal

The remote control enables the optimal switching on/off of the inverter by an external signal:

Loosen both Phillips screws and take off the cap (fig. 21).

2

A

B

3 2

4

1

Set the desired connection on the jumper (fig.23):

Jumper open (A): The inverter is switched on by positive battery voltage

When a plus-signal is present on the control cable, the inverter is switched on.

Jumpers are connected (B): The inverter is switched off by positive battery voltage

When a plus-signal is present on the control cable, the inverter is switched off (suitable e.g. for roof air conditioners). If no signal is received, then the inverter works in the previously activated function.

Mount the cap (fig. 21).

ACAUTION!The control cable has to be secured by a suitable fuse (1 A).

Connect the control cable (12 V or 24 V) at the (fig. 14) remote control connection

Operation

With the “Push” button (fig. 12) switch the inverter on or off.

10/2016

Dometic Australia Pty. Ltd.

4445102065

1 John Duncan Court

Varsity Lakes QLD 4227

www.dometic.com