Introduction safety

2

 

Technical data

3

 

Spare part list

4

 

Exploded view

5

 

Wiring diagram

6 - 7

 

Program diagram

8 - 9

This documentation is only intended for qualified technicians who are aware of the respec-

tive safety regulations.

 

Date: 09.07.2004 (Mod. 01)

Subject to modification

Document-No.: 4812 714 14726

 

22.05.2003 / Page 2

AMW 461 IX

Whirlpool Europe

 

S E R V I C E

Doc. No: 4812 714 14726

8587 461 99791

Customer Service

 

 

 

 

 

Introduction safety

INTRODUCTION

Before leaving the factory each oven is carefully checked.

It must, however, be installed and used correctly.

Despite all the steps taken to make the oven safe, the safety is dependent on the correct installation and the fact the user understands how to use and maintain the oven.

The information in this section should be used as a reminder that the oven is safe and that anyone who uses it must first read the instructions for use in order to be able to use the oven correctly and obtain best results.

SAFETY

To avoid injury to yourself and damage to the appliance always work to the following rules when servicing an oven.

Always disconnect the plug from the mains before starting work.

If there is no plug switch off the electric supply at the control box.

When you have finished servicing an oven before you reconnect it to the mains, make sure that:

-all the internal connections are correct

-the wires are insulated and not touching the door or the cabinet or anything sharp

-all the earth connections are electrically and mechanically sound

-do not modify or anyway interfere with the safety devices built-in to the oven

-make sure that each replacement part you use conforms to the manufacturer´s specifications

Do not start a repair if you have any doubt as to your ability to complete it.

CAUTION - MICROWAVE RADIATION

PERSONNEL SHOULD NOT BE EXPOSED TO THE MICROWAVE ENERGY WHICH MAY RADIATE FROM THE MAGNETRON, WAVEGUIDE OR ANTENNA IF THEY ARE IMPROPERLY USED OR CONNECTED. ALL INPUT

AND OUTPUT MICROWAVE CONNECTIONS, WAVEGUIDES, FLANGES AND GASKETS MUST BE SECURE. NEVER OPERATE THE DEVICE WITHOUT A MICROWAVE ENERGY ABSORBING LOAD ATTACHED. NEVER LOOK INTO AN OPEN WAVEGUIDE OR ANTENNA WHILE THE DEVICE IS ENERGIZED.

NEVER OPERATE AN OVEN WITH CABINET OFF WITHOUT MEASURING THE MICROWAVE LEAKAGE

AROUND MAGNETRON AND VISIBLE MICROWAVE CONNECTIONS (WELDING JOINTS).

Do not operate the oven if the following conditions exist:

-the door does not close firmly against the door support because of the door being warped or the hinges damaged.

-The door trims or seals are damaged.

-If there is any visible damage to the oven.

-if the door does not close properly.

Avoid operating the oven if known components in the interlock system, oven door or microwave generating assembly are known defective. They must be replaced.

WARNING - HIGH VOLTAGE

IT IS POSSIBLE TO COME IN CONTACT WITH LETHAL HIGH VOLTAGE WHEN WORKING WITH

HV TRANSFORMER, HV CAPACITOR AND MAGNETRON. THEREFORE NEVER TRY TO MEASURE

THE HIGH VOLTAGE. ALWAYS TAKE UTMOST CARE WHEN PERFORMING ELECTRIC

MEASUREMENTS INSIDE THE OVEN.

S E R V I C E

Technical data

Whirlpool Europe

AMW 461 IX

22.05.2003 / Page 3

Customer Service

8587 461 99791

Doc. No: 4812 714 14726

 

 

 

Product dimensions

 

 

Height

 

382

mm

Width

 

595

mm

Depth

 

320

mm

Cavity dimensions

 

 

Height

 

187

mm

Width

 

370

mm

Depth

 

290

mm

Cavity volume

22

l

Turntable diameter

250

mm

Weight

 

 

 

Net

 

19

kg

Gross

 

21,5

kg

Electrical

 

 

 

Voltage

 

230

V

Frequency

 

50

Hz

Fuse

 

10

A

Power

 

 

 

Power consumption

1300

W

Output power MW

750

W

4 power levels

 

 

Error codes

 

 

 

Certain fault conditions are indicated by an error code.

 

The following codes are implemented:

 

 

 

 

 

Error code

 

Description

 

 

 

 

ERR d

NTC overheat protection on the magnetron is faulty

 

 

(not connected or short circuit).

 

ERR 1

Short circuit in MW relay.

 

 

 

 

ERR 3

Key error when one of the buttons is pressed longer

 

 

than 1 minute.

 

 