Whirlpool AMB 887/G Service Manual

0 (0)
SERVICE
Model AMB 887/G Version 8528 887 10100 Page
Whirlpool Europe Customer Services
AMB 887/G
Service Manual
Air Conditioner Split Type AMB 887/G
Technical data 2
Spare part list 3
Exploded view 4
Circuit and Wiring diagram 5
This documentation is only intended for qualified technicians who are aware of the respec­tive safety regulations. Date: 11.08.2004 (Mod. 01) Subject to modification Document-No.: 4812 731 15454
20.03.2003 / Page 2 AMB 887/G Whirlpool Europe Doc. No: 4812 731 15454 8528 887 10100 Customer Service
Technical data
SERVICE
Factory Code AS-22HR4NR
Operation type
Cooling / Heating
Dimensions
Indoor - unit
Height 1025 mm Width 313 mm Depth 203 mm
Outdoor - unit
Height 832 mm Width 702 mm Depth 380 mm
Weight
Indoor - unit 14 kg / net Outdoor - unit 56 kg / net
Cooling Capacity
6881 Watt 23500 BTU / h
Heating Capacity
7466 Watt 25500 BTU / h
Airflow / Evaporator Airvolume
1000 m3 / h
Dehumidifying Capacity
2.8 l / h
Noise Level
Indoor - unit 41 - 48 dB(A) Outdoor - unit 58 dB(A)
Electrical connection
Voltage 220 - 240 V Frequency 50 Hz Rated Current (Cooling) 12.2 A Rated Current (Heating) 13.1 A
Energy Efficiency Rate (BTU/Watt hr)
Cooling 9.0 Heating 9.2
Compressor (cooling)
Type PG420X3C-4KU1 Capacity (CECOMAF) 7510 W
Refrigerant
Type R 407C Quantity 2120 g
Loading...
+ 3 hidden pages