Ingersoll-Rand 2475, 3000, 15T, 2545, 7100 User Manual

...
4.5 (2)

Owner’s Manual

Installation, Operation and Maintenance Instructions for Models 2340, 2475, 2545, 7100, 15T & 3000 Two-Stage Reciprocating Air Compressors

IMPORTANT INFORMATION! READ AND FOLLOW THESE INSTRUCTIONS. RETAIN FOR REFERENCE.

SAFETY

DEFINITIONS ________________________________________

DANGER

 

WILL cause DEATH, SEVERE INJURY or substantial

 

 

 

property damage.

WARNING

CAN cause DEATH, SEVERE INJURY or substantial

 

 

 

property damage.

CAUTION

WILL or CAN cause MINOR INJURY or property

 

 

 

damage.

GENERAL SAFETY PRECAUTIONS ____________________

DANGER

 

INTAKE AIR. Can contain carbon monoxide or other

 

 

 

contaminants. Will cause serious injury or death.

 

 

 

Ingersoll-Rand air compressors are not designed,

 

 

 

intended or approved for breathing air. Compressed

 

 

 

air should not be used for breathing air applications

 

 

 

unless treated in accordance with all applicable

 

 

 

codes and regulations.

WARNING

HAZARDOUS VOLTAGE. Can cause serious injury

 

 

 

or death. Disconnect power and bleed pressure

 

 

 

from the tank before servicing. Lockout/Tagout

 

 

 

machine. Compressor must be connected to

 

 

 

properly grounded circuit. See grounding

 

 

 

instructions in manual. Do not operate compressor

 

 

 

in wet conditions. Store indoors.

 

 

 

MOVING PARTS. Can cause serious injury. Do not

 

 

 

operate with guards removed. Machine may start

 

 

 

automatically. Disconnect power before servicing.

 

 

 

Lockout/Tagout machine.

 

 

 

HOT SURFACES. Can cause serious injury. Do not

 

 

 

touch. Allow to cool before servicing. Do not touch

 

 

 

hot compressor or tubing.

 

 

 

HIGH PRESSURE AIR. Bypassing, modifying or

 

 

 

removing safety/relief valves can cause serious

 

 

 

injury or death. Do not bypass, modify or remove

 

 

 

safety/relief valves. Do not direct air stream at body.

 

 

 

Rusted tanks can cause explosion and severe injury

 

 

 

or death. Drain tank daily or after each use. Drain

 

 

 

valve located at bottom of tank.

CAUTION

RISK OF BURSTING. Use only suitable air handling

 

 

 

parts acceptable for pressure of not less than the

 

 

 

maximum allowable working pressure of the

 

 

 

machine.

GENERAL INFORMATION

INTRODUCTION _____________________________________

This manual provides safe and reliable instructions for the installation, operation and maintenance of your Ingersoll-Rand air compressor. Carefully read this manual before attempting to operate or perform any maintenance. If you are uncertain about any of the instructions or procedures provided in this manual, contact Ingersoll-Rand. We recommend you retain this manual, and all publications provided with your air compressor, in a location which is accessible to all personnel who operate and service your compressed air equipment.

APPLICATION _______________________________________

Ingersoll-Rand’s standard two-stage lubricated air compressors are single-acting, air-cooled machines. Typical compressors are furnished as compact, self-contained, air receiver tank mounted units that are automatically regulated and driven by an electric motor or gasoline engine. An air-cooled aftercooler, low oil level shutdown switch and automatic drain valve are among the optional accessories that can be furnished. Bare compressor pumps and baseplate-mounted units are also available.

These compressors may be used for a variety of compressed air application up to 250 PSIG (17.5 kg/cm²). Application of these compressors as either a primary or supplementary source of air is virtually unlimited in industrial plants, service stations and auto repair shops. Supplementary service includes such uses as furnishing air at pressure not carried in regular shop lines, air at isolated locations, and standby service for air when larger compressors are shut down.

TWO-STAGE OPERATION _____________________________

Two-stage compressors consist of one or two first-stage cylinders with the same bore size and one second-stage cylinder with a smaller bore size.

Typical Two-Stage, Two

Typical Two-Stage, Three

Cylinder Unit

Cylinder Unit

© Ingersoll-Rand Company

C.C.N. : 22607402

 

 

Printed in U.S.A.

Rev.

: A

Date

: February 2005

 

http://air.irco.com

2

The basic principle of operation is as follows: On the suction stroke of the first-stage piston(s), air at atmospheric pressure enters the cylinders through the inlet filter(s) and then the inlet valves located in the head. On the compression stroke of the first-stage piston(s), the air is compressed to an intermediate pressure and discharged through the discharge valves(s) into common manifold(s). From the manifold(s) the air passes through the intercooler tubes, where the heat of first-stage compression is removed. On the suction stroke of the second-stage piston this cooled air enters the second-stage cylinder through the inlet valve. The compression stroke of the second-stage piston compresses the air to the final discharge pressure and forces it out through the discharge valve into the receiver tank or system. If cooling of the discharge air is required, an air-cooled aftercooler should be installed between the compressor discharge and the receiver tank or system.

For maintaining the receiver tank or system air pressure within predetermined limits, the compressor may be operated with automatic start & stop control or constant speed control regulation. The type of regulation used depends upon the application.

ADDITIONAL REFERENCES ___________________________

Unless otherwise stated, dimensions, weights and measurements are provided in standard U.S. measure followed in parentheses by the metric conversion. Any torque values given are stated in inch or foot pounds followed by the Newton-meter equivalent in parentheses. Electrical characteristics are given in voltage-phase-hertz.

RECEIPT & INSPECTION

Ensure adequate lifting equipment is available for unloading and moving the unit to the installation site.

NOTE

Lifting equipment must be properly rated for the

 

weight of the unit.

CAUTION

Lift the unit by the shipping skid only. Do not use

 

the motor lifting eye to lift the entire unit. The motor

 

lifting eye is for removing the motor from the unit

 

only.

CAUTION!

Do not work on or walk under the unit while it is

 

suspended.

Before signing the delivery receipt, inspect for damage and missing parts. If damage or missing parts are apparent, make the appropriate notation on the delivery receipt, then sign the receipt. Immediately contact the carrier for an inspection.

All material must be held in the receiving location for the carrier’s inspection.

Delivery receipts that have been signed without a notation of damage or missing parts are considered to be delivered “clear.” Subsequent claims are then considered to be concealed damage claims. Settle damage claims directly with the transportation company.

If you discover damage after receiving the unit (concealed damage), the carrier must be notified within 15 days of receipt and an inspection must be requested by telephone with confirmation in writing. On concealed damage claims, the burden of establishing that the unit was damaged in transit reverts back to the claimant.

Read the unit nameplate to verify it is the model ordered, and read the motor nameplate to verify it is compatible with your electrical conditions. Make sure electrical enclosures and components are appropriate for the installation environment.

INSTALLATION

SELECTING A LOCATION _____________________________

ELECTRIC MOTOR UNITS. For most electric motor units, select a relatively clean and dry well-lighted indoor area with plenty of space for proper ventilation, cooling air flow and accessibility. Provide 1,000 cubic feet of fresh air per 5 horsepower. Locate the unit at least 15 inches (38 cm) from walls, and make sure the main power supply is clearly identified and accessible.

Unless the electrical components of the unit are specially protected for outdoor use, do not install an electric motor unit outdoors or in an area that will expose the electrical components to rain, snow or sources of appreciable moisture.

WARNING FOR UNITS EQUIPPED

WITH ELECTRIC DRAIN VALVE

WARNING The electric drain valve incorporates arcing or sparking parts, such as snap switches, receptacles and the like that tend to produce arcs or sparks and, therefore, when located in a garage, the compressor should be in a room or enclosure provided for the purpose, or the electric drain valve should be 18 inches (457 mm) or more above the floor.

GASOLINE ENGINE UNITS. For gasoline engine units, keep the engine at least 3 feet (1 m) away from building walls and other equipment. Install the unit in a location with plenty of space for proper ventilation, cooling air flow and accessibility. Do not install or operate a gasoline engine unit in a confined area.

AMBIENT TEMPERATURE CONSIDERATIONS. Ideal operating temperatures are between 32°F and 100°F (0°C and 37.8°C). If temperatures consistently drop below 32°F (0°C), install the compressor in a heated area. If this is not possible, you must protect safety/relief valves and drain valves from freezing. If temperatures are consistently below 40°F (4.4°C), consider installing an external crankcase heater kit, especially if the compressor has difficulty starting.

CAUTION Never operate the compressor in temperatures below -15°F (-26.1°C) or above 125°F (51.0°C).

HUMID AREAS. In frequently humid areas, moisture may form in the pump and produce sludge in the lubricant, causing running parts to wear out prematurely. Excessive moisture is especially likely to occur if the unit is located in an unheated area that is subject to large temperature changes.

Two signs of excessive humidity are external condensation on the pump when it cools down and a “milky” appearance in petroleum lubricant.

You may be able to prevent moisture from forming in the pump by increasing ventilation, operating for longer intervals or installing an external crankcase heater kit.

NOISE CONSIDERATIONS. Consult local officials for information regarding acceptable noise levels in your area. To reduce excessive noise, use vibration isolator pads or intake silencers, relocate the unit or construct total enclosures or baffle walls.

http://air.irco.com

3

MOUNTING _________________________________________

WARNING Remove the unit from the skid before mounting.

ELECTRIC MOTOR UNITS. Bolt the unit to a firm, level foundation (such as a concrete floor). Do not bolt uneven feet tightly to the foundation, as this will cause excessive stress on the receiver tank. Use metal shims under the “short” feet if necessary.

Typical Permanent Mounting (Customer Supplied Hardware)

GASOLINE ENGINE UNITS. Bolt the unit to a firm, level foundation. Do not bolt uneven feet tightly to the foundation, as this will cause excessive stress on the receiver tank. Use metal shims under the “short” feet if necessary. Gasoline engine units mounted on truck beds must be fastened securely without applying excessive stress on the receiver tank. We recommend installing a vibration isolator kit with gasoline engine models.

INSTALLING REMOTE AIR INLET PIPING _______________

CAUTION Do not operate the unit without air inlet filtration.

If the air around the unit is relatively free of dirt, install the air inlet filter at the inlet connection at the pump. If the air is dirty, pipe the filter to a source of clean air. Use PVC plastic tubes for remote inlet piping. Do not use black pipe or galvanized pipe, as these promote sweating and rust. Consider installing an in-line type filter for ease of cleaning and replacement. Make the line as short and direct as possible and as large, or larger, than the diameter of the inlet connection on the pump. Do not install piping with a diameter lower than that of the pump intake.

Increase the pipe diameter one size for every 10 feet (3 m) of length or every 90° bend. Make sure the piping is adequately braced.

If you pipe the filter outdoors, cover it with a hood to prevent the entrance of rain or snow.

Heavy duty filter elements and filtration equipment are available for fine airborne dust, such as cement and rock dust.

Typical Remote Air Inlet Piping.

ELBOW

SUPPORT

Direct to compressor air intake (if distance is less than 6 feet)

PIPE

SUPPORT

INTAKE HOSE

TEE

HOSE

FITTING

BUSHINGS

DRAIN VALVE

HOOD

AIR INLET

FILTER

OUTSIDE

WALL

INSTALLING DISCHARGE PIPING ______________________

WARNING Do not use plastic pipe, soldered copper fittings, rubber hose, or lead-tin soldered joints anywhere in the compressed air system.

CAUTION! If you will be using synthetic compressor lubricant, all downstream piping material and system components must be compatible. Refer to the following material compatibility list. If there are incompatible materials present in your system, or if there are materials not included in the list, contact Ingersoll-Rand for recommendations.

SYNTHETIC COMPRESSOR LUBRICANT

MATERIAL COMPATIBILITY LIST

SUITABLE

Viton®, Teflon®, Epoxy (Glass Filled), Oil Resistant Alkyd, Fluorosilicone, Fluorocarbon, Polysulfide, 2-Component Urethane, Nylon, Delrin®, Celcon®, High Nitrile Rubber (Buna N. NBR more than 36% Acrylonitrile), Polyurethane, Polyethylene, Epichlorohydrin, Polyacrylate, Melamine, Polypropylene, Baked Phenolics, Epoxy, Modified Alkyds

(® indicates trademark of DuPont Corporation)

NOT RECOMMENDED

Neoprene, Natural Rubber, SBR Rubber, Acrylic Paint, Lacquer, Varnish, Polystyrene, PVC, ABS, Polycarbonate, Cellulose Acetate, Low Nitrile Rubber (Buna N. NBR less than 36% Acrylonitrile), EPDM, Ethylene Vinyl Acetate, Latex, EPR, Acrylics, Phenoxy, Polysulfones, Styrene Acrylonitrile (San), Butyl

NOTE

All compressed air systems generate condensate

 

which accumulates in any drain point (e.g. tanks,

 

filters, drip legs, aftercoolers, dryers). This

 

condensate contains lubricating oil and/or

 

substances which may be regulated and must be

 

disposed of in accordance with local, state, and

 

federal laws and regulations.

GENERAL REQUIREMENTS. The piping, fittings, air receiver tank, etc. must be certified safe for at least the maximum working pressure of the unit. Use hard-welded or threaded steel or copper pipes and cast iron fittings that are certified safe for the unit’s discharge pressure and temperature. DO NOT USE PVC PLASTIC IN THE COMPRESSED AIR DISCHARGE LINE. Use pipe thread sealant on all threads, and make up joints tightly to prevent air leaks.

http://air.irco.com

4

CONDENSATE DISCHARGE PIPING. If installing a condensate discharge line, the piping must be at least one size larger than the connection, as short and direct as possible, secured tightly and routed to a suitable drain point or waste container. Condensate must be disposed of in accordance with local, state, and federal laws and regulations.

WARNING If an aftercooler, check valve, block valve, or any other restriction is added to the compressor discharge, install a properly-sized ASME approved safety/relief valve between the compressor discharge and the restriction.

INSTALLING ELECTRICAL WIRING (ELECTRIC MOTOR UNITS) _____________________________________________

WARNING Electrical installation and service should be performed by a qualified electrician who is familiar with all applicable local, state and federal laws and regulations.

GENERAL. The motor rating, as shown on the motor nameplate, and the power supply must have compatible voltage, phase and hertz characteristics.

WIRE SIZE. The electrical wiring between the power supply and electric motor varies according to motor horsepower and other factors. Install adequately sized power leads to protect against excessive voltage drop during start-up. Refer to the National Electric Code (NEC) for information on selecting the proper wire size and securing electrical connections. If you connect additional electrical equipment to the same circuit, consider the total electrical load when selecting the proper wire size. DO NOT USE UNDERSIZE WIRE.

If wire size information is not available, the wire sizes shown in the following wire selection chart can be used as a safe guide, if the distance does not exceed 50 feet (15.3 m). For longer distances, consult and electrical contractor or the local electric company for recommendations.

MOTOR

SINGLE

 

THREE

 

HP

PHASE

 

PHASE

 

 

115V

230V

200V

230V

460V

575V

1

12

14

14

14

14

14

1.5

10

14

14

14

14

14

2

8

14

14

14

14

14

3

8

12

14

14

14

14

5

4

8

10

12

14

14

7.5

 

6

8

10

14

14

10

 

 

8

8

12

14

15

 

 

4

6

10

10

20

 

 

3

4

8

10

25

 

 

1

2

6

8

30

 

 

0

1

6

8

MAGNETIC STARTER. If the motor installed on your unit has a motor reset button, it does not require a magnetic starter. If the motor does not have this button and the unit does not have a factory-installed starter, install a magnetic starter with thermal overload protection. Follow the manufacturer’s instructions for installation. Ingersoll-Rand cannot accept responsibility for damages arising from failure to provide adequate motor protection.

FUSES. Refer to the NEC to determine the proper fuse or circuit breaker rating required. When selecting fuses, remember the momentary starting current of an electric motor is greater than its full load current. Time-delay or “slow-blow” fuses are recommended.

PRESSURE SWITCH. On units without a factory-installed pressure switch, wire a pressure switch in accordance with the appropriate wiring schematic in the DIAGRAMS section of this manual. Mount the pressure switch in accordance with the manufacturer’s recommendations. The connecting line to the receiver tank must be as short and direct as possible, and certified safe for at least the maximum working pressure of the unit.

CONNECTING A BATTERY (GASOLINE ENGINE UNITS) __

NOTE

If you will be making connections to a remote

 

battery, the engine on the compressor unit must be

 

equipped with an alternator.

BATTERY. A 12 volt battery with a minimum current rating of 250 CCA (cold cranking amps) and minimum ampere-hour rating of 24 Ah should be sufficient for cranking most electric start engines.

BATTERY CABLES. Refer to the following table for size and length recommendations.

Cable

Maximum

Size (GA)

Length

6

5’ (1.5 m.)

4

7’-2.5" (2.1 m.)

2

12’ (3.6 m.)

CONNECTION PROCEDURES:

1.Connect the battery positive (+) cable (A) to the starter solenoid terminal (B).

2.Connect the battery negative (-) cable (C) to the bolt shown in the following illustration. Secure the wire in place by screwing a suitably-sized nut onto the bolt and down onto the terminal.

Kohler

Honda

Kawasaki

Ingersoll-Rand

3.Connect the battery positive (+) cable (A) to the battery positive (+) terminal.

4.Connect the battery negative (-) cable to the battery negative (-) terminal.

5.Coat the terminals and cable ends with corrosion-preventive grease.

http://air.irco.com

5

WARNING Remove the cable from the negative (-) side of the battery before servicing.

Refer to the engine manufacturer’s instructions for more information.

FUEL PUMP INSTALLATION (GASOLINE ENGINE UNITS) _

Some engines use an optional fuel pump to supply gasoline to the engine directly from a vehicle’s onboard fuel system. Install the fuel pump within 12 inches (30 cm) of the bottom surface of the vehicle’s fuel tank. Protect the pump from contamination by installing a fuel isolation valve and an inline filter between the pump fuel system.

COMPRESSOR LUBRICATION _________________________

CAUTION Do not operate without lubricant or with inadequate lubricant. Ingersoll-Rand is not responsible for compressor failure caused by inadequate lubrication.

SYNTHETIC COMPRESSOR LUBRICANT. Ingersoll-Rand recommends All Season Select synthetic lubricant from start-up. See the WARRANTY section for extended warranty information.

ALTERNATE LUBRICANTS. You may use XL-300 or a comparable petroleum-based lubricant that is premium quality, does not contain detergents, contains only anti-rust, anti-oxidation, and anti-foam agents as additives, has a flashpoint of 440°F (227°C) or higher, and has an auto-ignition point of 650°F (343°C) or higher.

See the petroleum lubricant viscosity table below. The table is intended as a general guide only. Heavy duty operating conditions require heavier viscosities. Refer specific operating conditions to Ingersoll-Rand for recommendations.

Temperature Around

Viscosity @ 100°F

Viscosity Grade

Compressor

 

(37.8°C)

 

 

 

°F

°C

SUS

Centistokes

ISO

SAE

< 40

< 4.4

150

32

32

10

40-80

4.4-26.7

500

110

100

30

80-125

26.7-51.0

750

165

150

40

If you use a petroleum-based compressor lubricant at start-up and decide to convert to All Season Select later on, the pump must be decarbonized and flushed before conversion. Contact Ingersoll-Rand for more information.

FILLING PROCEDURES:

1.Unscrew and remove the oil fill plug.

2.Fill the crankcase with lubricant.

3.Replace the oil fill plug HAND TIGHT ONLY.

CAUTION Do not remove the oil fill plug while the compressor is running.

Refer to the following table for crankcase capacity.

Model

Crankcase Capacity

2340

28 oz. (827 ml.)

2475

41 oz. (1212 ml.)

2545

73 oz. (2158 ml.)

7100

80 oz. (2365 ml.)

15T, 3000

144 oz. (4258 ml.)

Use one of the following methods illustrated to determine when the crankcase is full.

A = FULL level at bottom thread of oil fill opening on units without sight glass or dipstick.

B = ADD level below bottom thread of oil fill opening on units without sight glass or dipstick.

C = FULL level on units with sight glass.

D = ADD level on units with sight glass.

E = ADD level on units with dipstick.

F = FULL level on units with dipstick.

LOW OIL LEVEL SWITCH _____________________________

A float activated low oil level switch may be installed to protect your unit against damage due to insufficient compressor oil level. Low oil level in the compressor crankcase causes the switch contacts to open, thus shutting the unit down until the proper oil level has been restored.

Proper protection against low oil level depends on proper adjustment of the low oil level switch. During the initial run, stop the unit and drain one quart of oil from the compressor crankcase into a suitable clean container. Listen for the switch to click or check the switch with a continuity tester.

The float sometimes gets cocked or stuck during shipping. If the float is cocked or stuck, open the disconnect switch, drain the remaining oil, remove the crankcase cover and then free the float. Reassemble and then reuse the same oil.

NOTE

If the float is cocked in the low position, the unit

 

cannot start.

http://air.irco.com

6

OPERATION

INTERMITTENT DUTY FORMULA ______________________

Units operating above 200 PSIG are to be operated according to the "Intermittent Duty Formula."

INTERMITTENT DUTY FORMULA

Pump-up time should not ordinarily exceed thirty (30) minutes or be less than ten (10) minutes. Shutdown periods between cycles of operation should be at least equal to the pump-up time. Note: When the compressor is regulated by constant speed control, the shutdown period is the time the compressor is operating unloaded.

A pump-up time limit with the following cool-down period is recommended to protect the valves and heads against stabilized high operating temperatures, which could rapidly build up carbon in these areas.

All inquiries for high-pressure compressor application where the "use" cycle differs from the "Intermittent Duty Formula" should be referred to Ingersoll-Rand.

START-UP (ELECTRIC MOTOR DRIVEN MODELS) _______

1.Close the service valve.

2.Release any remaining tank pressure by slowly opening the manual drain valve.

3.Close the manual drain valve and apply power to the compressor. If the pressure switch is equipped with an “ON/AUTO-OFF” lever, flip the switch to the “ON/AUTO” position. If the unit is equipped with a control panel “ON/OFF” switch, move the switch to the “ON” position.

Typical Pressure Switch Lever (If Equipped)

4. Slowly open the service valve.

Typical Service Valve (A = Open, B = Closed)

CAUTION

Unusual noise or vibration indicates a problem. Do

 

not continue to operate until you identify and

 

correct the source of the problem.

NOTE

Ensure the direction of rotation is correct per the

 

arrow on the motor. If the rotation is incorrect on

 

three-phase units, interchange any two of the three

 

leads.

START-UP (GASOLINE ENGINE UNITS) _________________

WARNING Do not operate gasoline engine units in an enclosed area.

1.Release any remaining tank pressure by slowly opening the manual drain valve.

2.Turn on the engine gasoline supply.

3.Put the choke in the “on” position.

4.Close the service valve and put the unloader lever in the “unload”

(A) position for Kawasaki and Honda engine driven models, or the “load” (B) position for Kohler engine driven models.

5.Start the engine, release the choke, and allow the engine to warm up for two to three minutes.

6.Return the unloader lever to the “load” (B) position on Kawasaki and Honda engine driven models.

Typical Unloader (A = Unload, B = Load)

A

B

NOTE

Turn the gasoline supply off when the compressor

 

is not being used.

NOTE

Some gasoline engine driven compressors require

 

5-8 break-in hours of operation before reaching full

 

capacity and speed.

COMPRESSOR CONTROLS ___________________________

AUTOMATIC START & STOP CONTROL. This type of control applies to electric motor driven models under 10 horsepower.

NOTE

Automatic Start & Stop Control is intended for use

 

when the motor will start no more than 6 times per

 

hour.

When the receiver tank pressure reaches the factory pre-set maximum pressure (usually 175 PSIG), the pressure switch stops the unit. When the receiver tank pressure drops below the factory pre-set minimum (usually 135 PSIG), the pressure switch resets and restarts the unit.

CONSTANT SPEED CONTROL. This type of control applies to gasoline engine units.

When the receiver tank pressure reaches the factory pre-set maximum pressure (usually 175 PSIG), the unloader slows down the engine and the unit stops pumping. When the receiver tank pressure drops to the factory pre-set minimum (usually 145 PSIG), the unloader resets, the engine returns to full speed, and the unit resumes pumping.

DUAL CONTROL. This type of control applies to electric motor units over 10 horsepower. Select either automatic start and stop control or constant speed control by adjusting the knob on the auxiliary valve. For automatic start and stop control, turn the knob on the auxiliary valve fully clockwise to disable the auxiliary valve. The pressure switch will then start and stop the unit.

NOTE

For dual control models, automatic start and stop is

 

preferred.

http://air.irco.com

7

Auxiliary Valve.

Pressure Switch Range Adjustment.

Select constant speed control if the unit restarts in less than 10 minute intervals or runs more than 40 minutes per hour. Turn the knob fully counterclockwise to run the unit continually. When the receiver tank pressure reaches 170 PSIG, the unit runs but does not pump.

NOTE

The auxiliary valve is factory pre-set at 5 PSIG lower

 

than the factory pressure switch setting.

CAUTION

Running unloaded for more than 20 minutes per

 

hour or more than 15 minutes continually with the

 

use of constant speed control will cause oil

 

pumping and should be avoided.

PRESSURE SWITCH ADJUSTMENT ____________________

WARNING

High voltage is present at the pressure switch

 

contacts when the power supply is connected.

 

Disconnect, lock and tag main power supply before

 

making adjustments.

CAUTION

Do not adjust the pressure switch to exceed the

 

maximum discharge pressure of the unit.

NOTE

Adjust the pressure switch only if adjustments are

 

absolutely necessary.

CUT-IN & CUT-OUT. The cut-out (compressor shut-down) is the pressure at which the switch contacts open, and the cut-in (compressor restart) is the pressure at which the switch contacts close. See COMPRESSOR CONTROLS.

ADJUSTMENT CONTROLS. All pressure switches have a range adjustment control (A). Some pressure switches also have a differential adjustment (B) control. On switches without a differential adjustment control, the span between cut-in and cut-out pressure levels switches is factory set for 40 ± 4 PSIG and cannot be adjusted.

NOTE

Some pressure switches are equipped with an

 

on-off lever used to open and close the electrical

 

contacts inside the switch. THIS LEVER IS NOT A

 

DIFFERENTIAL ADJUSTMENT CONTROL. The

 

pressure switches with the on-off lever do not have

 

a differential adjustment control.

ADJUSTMENT PROCEDURES (SWITCHES WITHOUT DIFFERENTIAL ADJUSTMENT CONTROL):

1.Remove the pressure switch cover.

2.Adjust the range by turning the range adjustment screw clockwise (in) to increase the cut-out point or counter-clockwise (out) to decrease the cut-out point.

NOTE:

One full turn changes the setting approximately 2

 

PSIG.

3.Replace cover, reconnect power supply and start the compressor.

4.Note the pressure gauge reading at which the compressor cuts out.

5.Repeat adjustment procedure if necessary.

ADJUSTMENT PROCEDURES (SWITCHES WITH DIFFERENTIAL ADJUSTMENT CONTROL):

1.Remove the pressure switch cover.

2.Set the cut-in pressure with the range adjustment nut. Turn the nut

clockwise (in) to increase the pressure or counter-clockwise (out) to decrease the pressure.

NOTE: One full turn changes the setting approximately 2 PSIG.

3. Set the cut-out pressure with the differential adjustment. Turn the differential adjustment nut clockwise (in) to increase the pressure or counter-clockwise (out) to decrease the pressure.

NOTE: One full turn changes the setting approximately 2 PSIG.

4.Replace the cover, reconnect the power supply and start the unit.

5.Note the pressure gauge reading at which the unit cuts out.

6.Repeat the adjustment procedure if necessary.

The minimum possible differential is approximately 20% of cutout pressure. It is advisable to have as wide a differential as possible to avoid frequent starting and stopping of the unit. Note the pressure gauge reading at which the unit cuts-out and re-establish this point if necessary.

Note the interaction between the range and differential adjustments, i.e., if the cut-out is increased, the differential will also increase, or if the differential is narrowed, the cut-out will be reduced, etc. These factors must be considered when adjusting the switch and compensated for accordingly.

STARTING UNLOADING SYSTEM ______________________

The starting unloading feature exists on certain models. The purpose of the system is to relieve cylinder pressure when the unit stops, permitting it to start against a light load. A light load increases the life of the driver and belts and also reduces the possibility of tripping the overload relay. The system operates in the following manner:

The centrifugal unloader is attached to the end of the crankshaft as shown in the following illustrations.

When the unit starts, centrifugal force acts upon the unloader weights and they swing outward. This permits the plunger and thrust pin to move inward and the pilot valve to close. The escape path to atmosphere for the cylinder pressure is now closed and the compressor pumps air in a normal manner.

When the unit stops, the weights retract, permitting the thrust pin spring to move the plunger and thrust pin outward. The thrust pin opens the pilot valve and the trapped air pressure escapes from the cylinder and intercooler through a passage in the frame end cover, through the unloader tube and to atmosphere through the inlet filter/silencer.

http://air.irco.com

Position of weight and thrust pin when unit is operating.

Position of weight and thrust pin when unit is stopped.

8

BREATHER/UNLOADER BY-PASS _____________________

The breather/unloader by-pass tube lines eliminates air pressure build-up in the compressor frame by providing a passage for the air to escape through the inlet unloader (if opened) or (if closed) through the check valve, therefore, by-passing the inlet unloader and escaping to atmosphere through the inlet filter/silencer.

OIL CONSUMPTION CHECK ___________________________

A rule of thumb in determining a "passing grade" for oil consumption is to consider consumption at or above 50 horsepower-hours per ounce to be acceptable.

The formula is as follows:

Horsepower X Hours of Operation = Horsepower Hours

per Ounce

Ounces of Oil Used

To apply this formula, consider the size of the machine. In the following example, a 5 horsepower compressor uses 2 ounces of oil every 20 hours of operation.

5 Horsepower

X

20 Hours of

=

50 Horsepower

 

 

Operation

 

Hours per Ounce

2 Ounces of Oil Used

The compressor in the example passes the oil consumption test.

NOTE

New or rebuilt compressor pumps will discharge

 

higher than normal amounts of oil until the piston

 

rings are seated (approximately 100 operating

 

hours).

MAINTENANCE

PILOT VALVE ADJUSTMENT __________________________

If the pilot valve tube line is excessively hot, it is a good indication that the pilot valve is leaking and adjustment is required.

To adjust the pilot valve, proceed as follows:

1.Stop the unit and disconnect and tag the electrical supply main switch to prevent accidental start-up.

2.Remove the pilot valve tube and the tube fittings.

3.Remove the pilot valve body and all existing shims.

4.Screw the pilot valve body back into the frame end cover (without any shims) until contact with the thrust pin is felt. Advance the pilot valve body 1/4 to 1/2 turn more.

If contact with the thrust pin cannot be felt, the following steps may be necessary to locate the contact point:

1.Insert a small instrument (punch, rod, nail, etc.) into the end of the pilot valve until it contacts the valve stem.

2.While still inserted in the pilot valve, make a mark on the instrument even with the outside edge of the pilot valve body.

3.Keeping the instrument pressed lightly against the valve stem, screw the pilot valve body into the frame end cover. When the mark on the instrument starts moving out away from the edge of the pilot valve body, contact has been made with the thrust pin.

4.Advance the pilot valve body 1/4 to 1/2 turn more and proceed with step five.

5.Measure the gap between the pilot valve body and the frame end cover.

6.Remove the pilot valve body and add enough shims to fill the gap measured in step five.

7.Screw the pilot valve body back into the frame end cover until the body is tight on the shims.

8.Reconnect the pilot valve tube and tube fittings.

WARNING

Before performing maintenance, release air

 

pressure from the system and disconnect, lock and

 

tag the main power supply or disconnect the wire

 

from the engine spark plug.

NOTE

All compressed air systems contain maintenance

 

parts (e.g. lubricating oil, filters, separators) which

 

are periodically replaced. These used parts may be,

 

or may contain, substances that are regulated and

 

must be disposed of in accordance with local, state,

 

and federal laws and regulations.

NOTE

Take note of the positions and locations of parts

 

during disassembly to make reassembly easier. The

 

assembly sequences and parts illustrated may differ

 

for your particular unit.

NOTE

Any service operations not explained in this manual

 

should be performed by an authorized service

 

representative.

NOTE

Reference the engine owner's manual for engine

 

care information.

NOTE

The following maintenance schedule has been

 

developed for typical applications. Maintenance

 

intervals should be shortened in harsher

 

environments.

http://air.irco.com

9

MAINTENANCE SCHEDULE

Daily or Before Each Operation

Weekly

Monthly

3/500 *

12/2000 *

Check for oil leaks.

Check lubricant level. Fill as needed.

Drain receiver tank condensate (if automatic draining device is not provided). Open manual drain valve and collect and dispose of condensate accordingly.

Check for unusual noise and vibration.

Ensure beltguards and covers are securely in place.

Ensure engine (if supplied) is filled with fuel and lubricant according to the manufacturer’s recommendations.

Ensure area around compressor is free from rags, tools, debris, and flammable or explosive materials.

Observe operation of safety/relief valves while the compressor is running. Replace safety/relief valves that do not operate freely.

Inspect air filter element(s). Clean if necessary.

Inspect for air leaks. Squirt soapy water around joints during compressor operation and watch for bubbles.

Check tightness of screws and bolts. Tighten as needed.

Inspect drive belts. Adjust if necessary.

Clean exterior.

Change petroleum lubricant while crankcase is warm.

Drain compressor oil and clean oil sight glass

Install maintenance pak

— or —

Change synthetic lubricant while crankcase is warm.

Replace filter element.

* indicates months/operating hours, whichever occurs first.

FILTER INSPECTION & CLEANING _____________________

1.Unscrew and remove the wing nut (A) securing the filter housing (B) to its base (C).

2.Remove the filter housing and withdraw the old filter element (D). Clean the element with a jet of air or vacuum.

3.Replace the filter element and housing, securing it in place with the wing nut previously removed.

OIL CHANGE ________________________________________

1.Remove the oil drain plug (A) and allow the lubricant to drain into a suitable container.

2.Replace the oil drain plug.

3.Follow the filling procedures in OPERATION section.

BELT ADJUSTMENT _________________________________

CHECKING BELT TENSION. Check belt tension should be occasionally, especially if looseness is suspected. New belts must also be properly tensioned upon installation.

TENSIONING BELTS. Belt tensioning can be achieved by loosening the motor or engine anchor screws, pushing the motor or engine away from the pump, and retightening the motor or engine anchor screws. Some units are equipped with a belt tensioning bolt that, when turned, pulls the motor or engine away from the pump. Otherwise, the motor can be easily moved by placing a prying tool beneath it. A commercially available spreader or other belt tensioning device can also be helpful.

Follow the procedures outlined below to correctly set and measure belt tension on electric motor and gas engine models including 2340, 2475, and 2545 (with "A" belt type only). Refer to the following illustration for a visual representation.

1.Lay a straight edge across the top outer surface of the belt drive from pulley to sheave.

2.At the center of the span, perpendicular to the belt, apply pressure to the outer surface of the belt with a tension gauge. Force the belt to the deflection indicated in the BELT TENSION TABLE in the DIAGRAMS & TABLES section. Compare the reading on the tension gauge to the table.

Follow the procedures outlined below to correctly set and measure tension on 7.5 through 30 horsepower models 2545, 7100, 15T and 3000 with "B" and "C" belt types.

1.Measure the span length (t) of the drive.

2.Determine the amount of deflection (in inches) required to measure deflection force (in pounds) by multiplying the span length (t) by 1/64. For example, a 32” span length multiplied by 1/64 equals 1/2” of deflection required to measure deflection force.

3.Lay a straight edge across the top outer surface of the belt drive from pulley to sheave.

4.At the center of the span, perpendicular to the belt, apply pressure to the outer surface of the belt with a tension gauge. Force the belt to the predetermined deflection calculated in step 2. Compare the reading on the tension gauge to the BELT TENSION TABLE in the DIAGRAMS & TABLES section.

http://air.irco.com

10

Ensure the pulley and sheave are properly aligned and the motor anchor screws are adequately retightened prior to restarting the compressor.

CAUTION Improper pulley/sheave alignment and belt tension can result in motor overload, excessive vibration, and premature belt and/or bearing failure.

To prevent these problems from occurring, ensure the pulley and sheave are aligned and belt tension is satisfactory after installing new belts or tensioning existing belts.

ELECTRIC DRAIN MAINTENANCE _____________________

NOTE

The following maintenance schedule has been

 

developed for typical applications. Maintenance

 

intervals should beshortened in harsher

 

environments.

 

 

 

 

 

DRAIN VALVE MAINTENANCE SCHEDULE

DAILY

 

Test the valve for proper

 

 

operation. Clean the filter screen

 

 

if needed.

MONTHLY (EVERY 30 DAYS)

Clean the filter screen.

To clean the filter screen, perform the following steps:

1.Close the strainer ball valve completely to isolate it from the air receiver tank.

2.Press the TEST button on the timer to vent the pressure remaining in the valve. Repeat until all pressure is removed.

CAUTION High pressure air can cause injury from flying debris. Ensure the strainer ball valve is completely closed and pressure is released from the valve prior to cleaning.

3.Remove the plug from the strainer with a suitable wrench. If you hear air escaping from the cleaning port, STOP IMMEDIATELY and repeat steps 1 and 2.

4.Remove the stainless steel filter screen and clean it. Remove any debris that may be in the strainer body before replacing the filter screen.

5. Replace plug and tighten with wrench.

Position of weight and thrust pin when unit is operating.

6.When putting the EDV-2000 back into service, press the TEST button to confirm proper function.

TANK INSPECTION __________________________________

The life of an air receiver tank is dependent upon several factors including, but not limited to, operating conditions, ambient environments, and the level of maintenance. The exact effect of these factors on tank life is difficult to predict; therefore, Ingersoll-Rand recommends that you schedule a certified tank inspection within the first five years of compressor service. To arrange a tank inspection, contact Ingersoll-Rand.

If the tank has not been inspected within the first 10 years of compressor service, the receiver must be taken out of service until it has passed inspection. Tanks that fail to meet requirements must be replaced.

WARNING Failure to replace a rusted air receiver tank could result in air receiver tank rupture or explosion, which could cause substantial property damage, severe personal injury, or death. Never modify or repair tank. Obtain replacement from service center.

http://air.irco.com

11

 

 

 

 

 

 

 

TROUBLESHOOTING

 

 

 

 

 

 

 

PROBLEM

CHECK POINT

 

 

Abnormal piston, ring or cylinder wear

4, 8, 9, 19, 28, 35

 

 

Air delivery drops off

1, 6, 15, 16, 18, 19, 29

 

 

Automatic drain valve leaks or does not drain automatically

16

 

 

Auxiliary valve chatters or leaks around stem

23, 24

 

 

Broken intercooler or aftercooler tubes

36

 

 

Compressor does not come up to speed

2, 6, 12, 15, 21

 

 

Compressor is slow to come up to speed

26, 27, 33, 34

 

 

Compressor runs excessively hot

3, 14, 15, 22

 

 

Compressor will not unload cycle

23, 24, 26

 

 

Compressor will not unload when stopped

26, 33

 

 

Excessive noise during operation

2, 6, 15, 16, 21, 27, 32

 

 

Excessive starting and stopping

5, 11, 16, 32, 40

 

 

Knocks or rattles

2, 15, 17, 19, 20, 21

 

 

Lights flicker or dim when running

12, 13

 

 

Moisture in crankcase or “milky” appearance in petroleum lubricant or

9, 10

 

 

rusting in cylinders

 

 

 

Motor overload trips or draws excessive current

5, 6, 12, 13, 14, 15, 16, 19, 20, 21, 34

 

 

Oil in discharge air (oil pumping)

4, 7, 9, 18, 19, 25, 35

 

 

Oil leaking from shaft seal

25

 

 

Safety/relief valve “pops”

1, 5, 29, 30

 

 

High interstage pressure

30

 

 

Low interstage pressure

31

 

 

Engine cranks slowly or will not start

6, 14, 37, 38

 

 

Motor will not start

12

 

 

Engine will not start

39

 

 

Oil Leaks

41

 

ELECTRIC DRAIN TROUBLESHOOTING

Trouble

Cause

Action

Valve will not close.

1. Debris in solenoid valve

1.

Remove solenoid valve,

 

 

prevents diaphragm from

 

disassemble, clean and

 

 

seating.

 

reassemble.

 

2.

Short in electrical component.

2.

Check and replace power cord

 

 

 

 

or timer as needed.

 

 

 

 

Timer will not activate.

1. No electrical supply.

1.

Apply power.

 

2.

Timer malfunction

2.

Replace timer.

 

3.

Clogged port.

3.

Clean valve.

 

4.

Solenoid valve malfunction.

4.

Replace solenoid valve.

 

5.

Clogged strainer.

5.

Clean strainer.

 

 

 

 

 

http://air.irco.com

12

CHECK POSSIBLE CAUSE

POINT

1Clogged or dirty inlet and/or discharge line filter.

2Loose beltwheel or motor pulley, excessive end play in motor shaft or loose drive belts.

3Inadequate ventilation around beltwheel.

4Lubricant viscosity too low.

5Air leaks in air discharge piping.

6Lubricant viscosity too high.

7Lubricant level too high.

8Lubricant level too low.

9Detergent type lubricant being used.

10Extremely light duty cycles.

Compressor located in damp or humid location.

11Pressure switch differential too narrow.

12Improper line voltage.

Wiring or electric service panel too small.

Poor contact on motor terminals or starter connections. Improper starter overload heaters.

13Poor power regulation (unbalanced line).

14Drive belts too tight or misaligned.

15Compressor valves leaky, broken, carbonized or loose.

16Automatic drain valve clogged, leaking or defective.

17Carbon build-up on top of piston(s).

18Piston rings damaged or worn (broken, rough or scratched). Excessive end gap or side clearance.

Piston rings not seated, are stuck in grooves or end gaps not staggered.

19Cylinder(s) or piston(s) scratched, worn or scored.

20Connecting rod, piston pin or crankpin bearings worn or scored. Loose bearing spacer on crankshaft.

21Defective ball bearings on crankshaft or motor shaft.

22Wrong beltwheel direction of rotation.

23Leaking, broken or worn inlet unloader parts.

24Auxiliary valve dirty or seats worn.

25Crankshaft seal worn or crankshaft scored.

26Leaking or maladjusted centrifugal pilot valve.

27Leaking check valve or check valve seat blown out.

28Extremely dusty atmosphere.

29Defective safety/relief valve.

30High pressure inlet valve leaking.

31Low pressure discharge valve leaking.

32Automatic start and stop mode is not suitable for air demand.

33Pressure switch unloader leaks or does not work.

34Ambient temperature too low.

35Worn cylinder finish.

36Beltwheel out of balance, tubes not braced or secured, wrong pulley speed.

37Engine not grounded properly.

38Gasoline exceeds storage time or contains water.

39No fuel in tank. Fuel valve closed. Low oil pressure.

40Excessive condensate in receiver tank.

41Loose fittings/elbows/connectors

POSSIBLE SOLUTION

Clean or replace.

Check beltwheel, motor pulley, crankshaft, drive belt tension and alignment. Repair or replace as required.

Relocate compressor for better air flow.

Drain existing lubricant and refill with proper lubricant. Check tubing and connections. Tighten joints or replace as required.

Drain existing lubricant and refill with proper lubricant. Drain excess lubricant.

Add lubricant to crankcase to proper level.

Drain existing lubricant and refill with proper lubricant. Run compressor for longer duty cycles.

Relocate compressor or install crankcase heater kit.

Adjust pressure switch to increase differential, if differential adjustment is provided. Install pressure switch with differential adjustment feature if differential adjustment is desired.

Check line voltage and upgrade lines as required. Contact electrician.

Intall properly sized wire or service box. Contact electrician. Ensure good contact on motor terminals or starter connections. Install proper starter overload heaters. Contact electrician. Contact power company.

Adjust belts to proper tension and alignment.

Inspect valves. Clean or replace as required. Install Valve/Gasket Step Saver Kit..

Inspect valve and clean, repair or replace as required. Clean piston(s). Repair or replace as required.

Install Ring/Gasket Step Saver Kit.

Adjust piston rings.

Repair or replace as required.

Inspect all. Repair or replace as required. Install Bearing/Connecting Rod Step Saver Kit. Inspect bearings and replace if required. Install Bearing/Connecting Rod Step Saver Kit.

Check motor wiring for proper connections. Reverse two leads on three-phase motors.

Inspect parts and replace as required.

Inspect parts. Clean, adjust or replace as required. Replace seal. Install shaft sleeve if required. Install Bearing/Connecting Rod Step Saver Kit.

Replace pilot valve o-ring. Adjust pilot valve. Replace check valve.

Install remote air inlet piping and route to source of cleaner air. Install more effective filtration.

Replace.

Inspect, clean or repair as required. Inspect, clean or repair as required.

Adjust auxiliary valve for constant speed operation. Realign stem or replace.

Install crankcase heater kit. Convert to All Season Select lubricant. Relocate compressor to warmer environment. Deglaze cylinder with 180 grit flex-hone.

Check vibration level, change pulley or beltwheel if required, tighten tube clamps.

Ground battery to engine as recommended. Replace gas, add fuel stabilizer.

See manufacturer’s instructions for refueling. Open fuel valve.

See manufacturer’s instructions.

Drain receiver tank with manual drain valve or install automatic drain valve.

Re-torque fittings per specified torque requirements

http://air.irco.com

13

DIAGRAMS & TABLES

FASTENER TORQUE TABLE

 

2340

2475

2545

7100

15T

3000

High Pressure Head Bolts

75

75

75

75

75

75

Low Pressure Head Bolts

75

75

75

75

75

75

Cylinder Flange Bolts

30

50

50

50

50

50

Frame Cover Bolts

17

17

17

20

20

20

Shaft Cover Bolts

17

17

17

20

20

20

Crankpin Cap Screws

5.5

11

11

12-15

12-15

12-15

Unloader Cover Screws

11

11

20

11

High Pressure Inlet Valve Screws

11-15 LB-IN

11-15 LB-IN

11-15 LB-IN

5.5

5.5

Low Pressure Inlet Valve Screws

11-15 LB-IN

25-30 LB-IN

25-30 LB-IN

5.5

5.5

High Pressure Outlet Valve Screws

11-15 LB-IN

11-15 LB-IN

11-15 LB-IN

26

50

26

Low Pressure Outlet Valve Screws

25-30 LB-IN

25-30 LB-IN

25-30 LB-IN

26

90

26

Beltwheel Bolt

33

60

60

113

213

213

High Pressure Head Center Bolts

10

Low Pressure Head Center Bolts

14-16

NOTE

Tighten all fasteners evenly using a cross pattern in two stages.

BELT TENSION TABLE

MODEL

 

DEFLECTION (IN.)

TENSION (LB.)

BELT

HORSEPOWER

TENSION AT 1/64" DEFLECTION PER

2340

(14" Span)

0.25

4.9 - 7.1

TYPE

 

INCH OF SPAN

 

 

 

2340

(19" Span)

0.29

4.9 - 7.1

B

7.5

7.0 - 10.0

 

 

 

2475

(14" Span)

0.25

4.9 - 7.1

 

10-15

8.0 - 12.0

 

 

 

2475

(19" Span)

0.29

4.9 - 7.1

C

20

12.0 - 18.0

 

 

 

2475F/X11GH

0.34

5.5 - 8.0

 

25-30

14.0 - 21.0

 

 

 

2475F/X9/11GK

0.25

11.25 - 13.0

 

 

 

2475N5 (14.5" Span, Cogged

0.23

4.5 - 6.5

 

 

 

belt)

 

 

 

 

 

 

2545

(A Groove)

0.29

4.9 - 7.1

 

 

 

http://air.irco.com

14

ELECTRICAL WIRING DIAGRAMS

Single Phase Wiring

 

 

 

A

To supply

 

C

Wiring for optional electric drain valve

 

EDV

Electric drain valve

 

T

Supply Line Terminal

 

L

Load Terminal

 

FU

Control Circuit Fuse

 

HATS

High Air Temperature Switch (#)

 

LOLS

Low Oil Level Switch (#)

 

M

Motor Starter Coil

 

OL

Motor Starter Overload

 

PS

Pressure Switch

 

SS

Selector Switch (#)

 

*

Alternate wiring for converting 3 phase starter to 1

 

 

phase application

 

(#) = if provided

 

 

 

Three Phase Wiring

 

NOTE

On units requiring a starter, connect line power to the starter. do not connect

 

line power to the pressure switch.

Connect ground wire to ground lug

L3 used for 3-phase motors & starters only

http://air.irco.com

15

Typical Baseplate Unit

Typical Horizontal Simplex Unit

http://air.irco.com

Ingersoll-Rand 2475, 3000, 15T, 2545, 7100 User Manual

16

Typical Vertical Simplex Unit

Typical Gasoline Engine Unit

Typical Duplex Unit

http://air.irco.com

17

WARRANTY

Ingersoll-Rand Company warrants that the Equipment manufactured by it and delivered hereunder shall be free of defects in material and workmanship for a period of twelve (12) months from the date of placing the Equipment in operation or eighteen (18) months from the date of shipment, whichever shall occur first. The foregoing warranty period shall apply to all Equipment, except for the following: (A) Compressors that are operated solely on All Season Select synthetic compressor lubricant will have their bare compressor warranted for the earlier of twenty-four (24) months from the date of initial operation or thirty (30) months from the date of shipment. (B) Replacement parts will be warranted for six (6) months from the date of shipment. Should any failure to conform to this Warranty be reported in writing to the Company within said period, the Company shall, at its option, correct such nonconformity by suitable repair to such Equipment, or furnish a replacement part F.O.B. point of shipment, provided the purchaser has installed, maintained and operated such equipment in accordance with good industry practices and has complied with specific recommendations of the Company. Accessories or equipment furnished by the Company, but manufactured by others, shall carry whatever warranty the manufacturer conveyed to Ingersoll-Rand Company and which can be passed on to the Purchaser. The Company shall not be liable for any repairs, replacements, or adjustments to the Equipment or any costs of labor performed by the Purchaser without the Company’s prior written approval.

The Company makes no performance warranty unless specifically stated within its proposal and the effects of corrosion, erosion and normal wear and tear are specifically excluded from the Company’s Warranty. In the event performance warranties are expressly included, the Company’s obligation shall be to correct in the manner and for the period of time provided above.

THE COMPANY MAKES NO OTHER WARRANTY OF REPRESENTATION OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY DISCLAIMED.

Correction by the Company of nonconformities, whether patent or latent, in the manner and for the period of time provided above, shall constitute fulfillment of all liabilities of the Company and its Distributors for such nonconformities with respect to or arising out of such Equipment.

LIMITATION OF LIABILITY

THE REMEDIES OF THE PURCHASER SET FORTH HEREIN ARE EXCLUSIVE, AND THE TOTAL LIABILITY OF THE COMPANY, ITS DISTRIBUTORS AND SUPPLIERS WITH RESPECT TO CONTRACT OR THE E UIPMENT AND SERVICES FURNISHED, IN CONNECTION WITH THE PERFORMANCE OR BREACH THEREOF, OR FROM THE MANUFACTURE, SALE, DELIVERY, INSTALLATION, REPAIR OR TECHNICAL DIRECTION COVERED BY OR FURNISHED UNDER CONTRACT, WHETHER BASED ON CONTRACT, WARRANTY, NEGLIGENCE, INDEMNITY, STRICT LIABILITY OR OTHERWISE SHALL NOT EXCEED THE PURCHASE PRICE OF THE UNIT OF E UIPMENT UPON WHICH SUCH LIABILITY IS BASED.

THE COMPANY, ITS DISTRIBUTORS AND ITS SUPPLIERS SHALL IN NO EVENT BE LIABLE TO THE PURCHASER, ANY SUCCESSORS IN INTEREST OR ANY BENEFICIARY OR ASSIGNEE OF THE CONTRACT FOR ANY CONSE UENTIAL, INCIDENTAL, INDIRECT, SPECIAL OR PUNITIVE DAMAGES ARISING OUT OF THIS CONTRACT OR ANY BREACH THEREOF, OR ANY DEFECT IN, OR FAILURE OF, OR MALFUNCTION OF THE E UIPMENT, WHETHER OR NOT BASED UPON LOSS OF USE, LOSS PROFITS OR REVENUE, INTEREST, LOST GOODWILL, WORK STOPPAGE, IMPAIRMENT OF OTHER GOODS, LOSS BY REASON OF SHUTDOWN OR NON-OPERATION, INCREASED EXPENSES OF OPERATION, COST OF PURCHASE OF REPLACEMENT POWER, OR CLAIMS OF PURCHASER OR CUSTOMERS OF PURCHASER FOR SERVICE INTERRUPTION WHETHER OR NOT SUCH LOSS OR DAMAGE IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, INDEMNITY, STRICT LIABILITY OR OTHERWISE.

http://air.irco.com

Loading...
+ 39 hidden pages