WS200 direct connection to NavNet 3D (NMEA2000 powered through NN3D)

To activate the internal resistor in the WS200 antenna, insert the supplied contact pin into socket #5 in the connector before connecting it to the antenna.

NMEA2000 Micro

Double-ended cable

Male – Female

1meter = 000-167-962

2meter = 000-167-963

6meter = 000-167-964

“T” Connector

AIR-052-531

Fem/Fem/Male

18 Pin pigtail cable supplied for use with Data 2 and 3 000-164-608

This is to supply voltage for the NMEA2000 Bus. The minimum voltage is 9 VDC and the maximum is 16 VDC.

(1 amp MAX load)

Pink

Data

Port 2

Pin 17

1 amp Fuse

(local supply)

NMEA2000

Terminator

Female

AIR-335-792

Light

Green

Data

Port 2

Pin 18

Furuno FI5002 User Manual

WS200 connection to DRS Dome and NavNet 3D

Inside DRS2D and DRS4D

To activate the internal resistor in the WS200 antenna, insert the supplied contact pin into socket #5 in the connector before connecting it to the antenna.

Cut the NMEA2000 connector off of WS200 cable and connect the wires to the green NMEA2000 connector inside the DRS2D or DRS4D.

Match the wire colors to the colors shown in the DRS Connector close-up.