Bosch AUTODOME IP 4000i, AUTODOME IP 5000i, NDP-5502-Z30, NDP-4502-Z12C, AUTODOME IP 4000i IR User Manual

...
0 (0)
AUTODOME IP 4000i/AUTODOME IP 5000i/ AUTODOME IP 5000i IR
NDP‑4502‑Z12NDP‑4502‑Z12CNDP‑5502‑Z30NDP‑5502‑Z30C NDP‑5502‑Z30L
en
User Manual
Table of contents | en 3
Bosch Security Systems User Manual 2018.05 | 1.1 |
Table of contents
1
Browser connection 6
1.1 Systems requirements 6
1.2 Establishing the connection 6
1.3 Password protection in camera 6
2
System overview 8
2.1 Live page 8
2.2 Configuration 8
2.3 Playback 8
3
Operation via the browser 9
3.1 Live page 9
3.1.1 Connection 9
3.1.2 PTZ 9
3.1.3 Pre-positions 9
3.1.4 AUX Control 10
3.1.5 Digital I/O 10
3.1.6 Special Functions 10
3.1.7 Recording status 11
3.1.8 Saving snapshots 11
3.1.9 Recording live video 11
3.1.10 Full-screen display 11
3.1.11 Audio communication 11
3.1.12 Storage, CPU and network status 11
3.1.13 Status icons 12
3.2 Playback via browser 12
3.2.1 Selecting the recording stream 13
3.2.2 Searching for recorded video 13
3.2.3 Exporting recorded video 13
3.2.4 Controlling playback 13
4
General 14
4.1 Identification 14
4.2 User Management 14
4.3 Date/Time 15
4.4 Display Stamping 16
4.5 GB/T 28181 18
5
Web Interface 20
5.1 Appearance 20
5.2 LIVE Functions 21
6
Camera 23
6.1 Installer Menu 23
6.1.1 Positioning 23
6.2 Scene Mode 26
6.3 Color 27
6.4 ALC 29
6.5 Enhance 30
6.6 Scene Mode Scheduler 30
6.7 Encoder Profile 30
6.8 Encoder Streams 33
6.9 Encoder Statistics 35
4 en | Table of contents
AUTODOME IP 5000i IR
2018.05 | 1.1 | User Manual Bosch Security Systems
6.10 Privacy Masks 35
6.11 Lens Settings 36
6.12 PTZ Settings 37
6.13 Pre-positions and Tours 38
6.14 Sectors 39
6.15 Miscellaneous 40
6.16 Illuminator 40
6.17 Audio 40
6.18 Pixel Counter 41
7
Recording 42
7.1 Introduction to recording 42
7.2 Storage Management 42
7.2.1 Device manager 42
7.2.2 Recording media 42
7.2.3 Activating and configuring storage media 43
7.2.4 Formatting storage media 43
7.2.5 Deactivating storage media 43
7.3 Recording Profiles 43
7.4 Maximum Retention Time 45
7.5 Recording Scheduler 45
7.6 Recording Status 46
7.7 Recording Statistics 46
7.8 SD Card Status 46
8
Alarm 47
8.1 Alarm Connections 47
8.2 Video Content Analysis (VCA) 49
8.3 Audio Alarm 51
8.4 Alarm E-Mail 52
8.5 Alarm Task Editor 53
8.6 Alarm Rules 53
9
Interfaces 55
9.1 Alarm Inputs 55
9.2 Alarm Outputs 55
10
Network 56
10.1 Network Services 56
10.2 Network Access 56
10.3 DynDNS 58
10.4 Advanced 59
10.5 Network Management 60
10.6 Multicast 61
10.7 Image Posting 62
10.8 Accounts 63
10.9 IPv4 Filter 63
10.10 Encryption 63
11
Service 64
11.1 Maintenance 64
11.2 Licenses 64
11.3 Certificates 64
11.4 Logging 65
Table of contents | en 5
Bosch Security Systems User Manual 2018.05 | 1.1 |
11.5 Diagnostics 65
11.6 System Overview 65
12
AUX Commands 66
6 en | Browser connection
AUTODOME IP 5000i IR
2018.05 | 1.1 | User Manual Bosch Security Systems
1 Browser connection
A computer with Microsoft Internet Explorer is used to receive live images, control the unit, and replay stored sequences. The unit is configured over the network using the browser.
1.1 Systems requirements
Our recommendations are: – Computer with Intel Skylake processor or better – Intel HD530 graphic card with performance that matches or is better than the resolution
of the camera
Windows7 or later operating system – Network access – Internet Explorer version 11 or later
– or –
Application software, for example, VideoSecurityClient, BoschVideoClient or Bosch Video Management System.
Note:
To see live images in your browser it might be necessary to download and install the MPEG­ActiveX from the Bosch download store.
1.2 Establishing the connection
The unit must have a valid IP address to operate on your network and a compatible subnet mask. By default, DHCP is pre-set at the factory to On plus Link-Local so a DHCP server assigns an IP address or, if no DHCP server is available, a link-local address (auto-IP) is assigned within the range 169.254.1.0 to 169.254.254.255. You can use IP Helper or Configuration Manager to find the IP address. Download the software from http://downloadstore.boschsecurity.com.
1. Start the Web browser.
2. Enter the IP address of the unit as the URL.
3. During initial installation, confirm any security questions that appear. If a RADIUS server is used for network access control (802.1x authentication), you must configure the device before the device can communicate with the network. To configure the device, connect it directly to a computer using a network cable and then set the service-level password.
Note:
If you cannot connect, the unit may have reached its maximum number of connections. Depending on the device and network configuration, each unit can have up to 50 web browser connections, or up to 100 connections via BoschVideoClient or Bosch Video Management System.
1.3 Password protection in camera
The device is password-protected. The first time that any user accesses the device, the device will prompt the user to set a password at the service level. The camera requires a strong password. Follow the prompts in the dialog box, which specifies what is required. The system measures the strength of the password that you enter.
Browser connection | en 7
Bosch Security Systems User Manual 2018.05 | 1.1 |
When you use Configuration Manager to access your device for the first time, you must set the initial password of the device in Configuration Manager. The Users section (General > Unit Access > Users) displays the message, "Before you can use this device you have to secure it with an initial password."
Note: After you set the initial password, a "lock" icon appears next to the device name in the Devices list in Configuration Manager.
You can also launch the device webpage directly. In the device webpage, an initial password page appears, displaying input fields and a password strength gauge. Enter the user name (“service”) and a password in the appropriate fields. Refer to the section User Management for more information. After a service-level password is set for the device, the device displays a dialog box that prompts users to enter the user name (“service”) and the service-level password every time that they access the device.
1. Fill in the fields User name and Password.
2. Click OK. If the password is correct, the desired page appears.
8 en | System overview
AUTODOME IP 5000i IR
2018.05 | 1.1 | User Manual Bosch Security Systems
2 System overview
When a connection is established, the Live page is initially displayed. The application bar displays the following icons:
Live To view the live video stream, click this icon.
Playback To play back recorded sequences, click this icon.
This link is only visible if a storage medium has been configured for recording. (With VRM recording this option is not active.)
Configuration To configure the unit, click this icon.
Links To navigate to the Bosch download store, click this
icon.
To get context sensitive help for a particular page, click this icon.
Note: None of the pages are accessible until after you set a service-level password.
2.1 Live page
The Live page is used to display the live video stream and control the unit.
2.2 Configuration
The Configuration page is used to configure the unit and the application interface.
Making Changes
Each configuration screen shows the current settings. You can change the settings by entering new values or by selecting a predefined value from a list field. Not every page has a Set button. Changes to pages without a Set button are set immediately. If a page does show a Set button, you must click the Set button for a change to take effect.
Notice!
Save each change with the associated Set button. Clicking the Set button saves the settings only in the current field. Changes in any other fields are ignored.
Some changes only take effect after the unit is rebooted. In this case, the Set button changes to Set and Reboot.
1. Make the desired changes.
2. Click the Set and Reboot button. The camera reboots and the changed settings are activated.
All settings are backed up in camera memory so they are not lost even if the power fails. The exception is the time settings, which are lost after 1 hour without power if no central time server is selected.
2.3 Playback
The Playback page is used for playing back recorded sequences.
Operation via the browser | en 9
Bosch Security Systems User Manual 2018.05 | 1.1 |
3 Operation via the browser
3.1 Live page
3.1.1 Connection
Stream 1
Select this option to display stream 1 of the camera.
Stream 2
Select this option to display stream 2 of the camera.
M-JPEG
Select this option to display the M-JPEG stream of the camera.
3.1.2 PTZ
Pan and tilt controls
To tilt the camera up: Click and hold the up arrow. – To tilt the camera down: Click and hold the down arrow. – To pan the camera left: Click and hold the left arrow. – To pan the camera right: Click and hold the right arrow. – To pan and tilt the camera at the same time (variable pan/tilt): Click and drag the center
area (that resembles a point stick or a trackball on a computer keyboard) around the PTZ control in the direction that you want to move the camera.
Zoom
Click the + button to zoom in. Click the - button to zoom out.
Iris
Click (Iris close) to close the iris.
Click (Iris open) to open the iris.
Focus
Click to focus near.
Click to focus far.
3.1.3 Pre-positions
The camera displays Pre-position 1 through Pre-position 6. Select the appropriate pre­position to view the video image for that pre-position/scene. In the lower left of the video image, the OSD displays the Camera number (title), the Pre-position number, and the Pre­position number stored. Below the list of pre-positions/scenes is a drop-down list showing the stored pre-positions/ scenes.
Select the appropriate pre-position (1 through 6). Click to store the pre-position.
Note: If the pre-position is already stored, a dialog box displays the message, “Overwrite current pre-position?” Click OK to overwrite, or click Cancel to cancel the operation.
Click to display the selected pre-position in the video image.
10 en | Operation via the browser
AUTODOME IP 5000i IR
2018.05 | 1.1 | User Manual Bosch Security Systems
3.1.4 AUX Control
With the tab AUX Control you can enter pre-programmed keyboard control commands. These commands are composed of a command number plus the appropriate function key (Show pre- position, Set pre-position, AUX on, or AUX off). A valid combination either issues a command to the device or displays an on-screen menu. (Refer to the “AUX Commands” section of the manual for a list of all AUX commands for your camera.)
Show pre-position
Click this button to display a pre-position.
Set pre-position
Click this button to set a pre-position.
AUX on
Click this button to activate an AUX command.
AUX off
Click this button to deactivate an AUX command.
3.1.5 Digital I/O
(only for cameras with alarm connections) Depending on the configuration of the unit, the alarm input and the output are displayed next to the image. Expand the Digital I/O group if necessary. The alarm symbol is for information and indicates the status of an alarm input: – The symbol lights when the input alarm is active. The alarm output allows the operation of an external device (for example, a light or a door opener). – To activate the output, click the checkmark symbol.
The symbol lights when the output is activated.
Input 1
This parameter identifies the first alarm input.
Input 2
This parameter identifies the second alarm input.
Output 1
Click the checkmark icon to enable the output. The checkmark becomes green.
Note: You can change the name of an alarm input in Configuration > Interfaces > Alarm Inputs > Input 1 (or Input 2) > Name. You can change the name of an alarm output in Configuration > Interfaces > Alarm Outputs > Output name.
3.1.6 Special Functions
Tour A / Tour B
Click one of these buttons to start the continuous playback of a recorded (guard) tour. A recorded tour saves all manual camera movements made during the recording, including its rate of pan, tilt and zoom speeds, and other lens setting changes. To stop a tour, click a directional control in the View Control tab.
Find home
Click this button to trigger the camera to seek its home position. The OSD displays the message, “OSD: Finding Home Position.”
Focus
Click this button to activate the Auto Focus One Push mode on the camera.
Operation via the browser | en 11
Bosch Security Systems User Manual 2018.05 | 1.1 |
The OSD displays the message, “Auto Focus: ONE PUSH.”
Nightmode
Click this button to activate/deactivate night mode for the camera. After a few seconds, the camera switches modes.
Custom tour
Click this button to view (in continuous playback) a custom tour that was previously configured. To stop a tour, click a directional control in the PTZ section of the page.
3.1.7 Recording status
The hard drive icon below the live camera image changes during an automatic recording. The icon lights up and displays a moving graphic to indicate a running recording. If no recording is taking place, a static icon is displayed.
3.1.8 Saving snapshots
Individual images from the displayed live video stream can be saved locally in JPEG format on the computer's hard drive. The storage location depends on the configuration of the camera.
Click the photo camera icon to save a single image.
3.1.9 Recording live video
Video sequences from the displayed live video stream can be saved locally on the computer's hard drive. The sequences are recorded at the resolution specified in the encoder configuration. The storage location depends on the configuration of the camera.
1. Click the recording icon to record video sequences. – Saving begins immediately. The red dot on the icon indicates that a recording is in
progress.
2. Click the recording icon again to stop recording.
3.1.10 Full-screen display
Click the full-screen icon to view the selected stream in full-screen mode; press Esc on the keyboard to return to the normal viewing window.
3.1.11 Audio communication
Audio can be sent and received via the Live page if the unit and the computer support audio.
1. Press and hold the F12 key on the keyboard to send an audio signal to the unit.
2. Release the key to stop sending audio.
All connected users receive audio signals sent from the unit but only the user who first pressed the F12 key can send audio signals; others must wait for the first user to release the key.
3.1.12 Storage, CPU and network status
When accessing the unit with a browser, the local storage, processor and network status icons are shown in the upper right of the window. When a local storage card is available, the memory card icon changes color (green, orange or red) to indicate the local storage activity. If you hover over this icon with the mouse the storage activity is shown as a percentage.
12 en | Operation via the browser
AUTODOME IP 5000i IR
2018.05 | 1.1 | User Manual Bosch Security Systems
If you hover over the middle icon, the CPU load is shown. If you hover over the right-hand icon, the network load is shown. This information can help with problem solving or when fine tuning the unit. For example: – if the storage activity is too high, change the recording profile, – if the CPU load is too big, change the VCA settings, – if the network load is too big, change the encoder profile to reduce bitrate.
3.1.13 Status icons
Various overlays in the video image provide important status information. The overlays provide the following information:
Decoding error
The frame might show artifacts due to decoding errors.
Alarm flag
Indicates that an alarm has occurred.
Communication error
A communication error, such as a connection failure to the storage medium, a protocol violation or a timeout, is indicated by this icon.
Gap
Indicates a gap in the recorded video.
Watermark valid The watermark set on the media item is valid. The color of the check mark changes according to the video authentication method that has been selected.
Watermark invalid
Indicates that the watermark is not valid.
Motion alarm
Indicates that a motion alarm has occurred.
Storage discovery
Indicates that recorded video is being retrieved.
3.2 Playback via browser
Click Playback in the application bar to view, search or export recordings. This link is only visible if a direct iSCSI or memory card has been configured for recording. (With VRM recording this option is not active.) The panel on the left has four groups: – Connection Search Export Track list
Operation via the browser | en 13
Bosch Security Systems User Manual 2018.05 | 1.1 |
3.2.1 Selecting the recording stream
On the left side of the browser, expand the Connection group if necessary. To view a recording stream:
1. Click the Recording drop-down arrow to see the options.
2. Select recording stream 1 or 2.
3.2.2 Searching for recorded video
On the left side of the browser, expand the Search group if necessary.
1. To limit the search to a particular time range, enter the date and times for the start and stop points.
2. Select an option from the drop-down box to define a search parameter.
3. Click Start Search.
4. The results are shown.
5. Click a result to play it back.
6. Click Back to define a new search.
3.2.3 Exporting recorded video
On the left side of the browser, expand the Export group if necessary.
1. Select a track in the track list or in the search results (or click on the timeline below the video window and drag the buttons to mark the sequence you want to export).
2. The start and stop date and time are filled-in for the selected track. If required, change the times.
3. In the Time lapse drop-down box, select the original or a condensed speed.
4. In the Location drop-down box, select a target.
5. Click Export to save the video track.
Note: The target server address is set on the Network / Accounts page.
3.2.4 Controlling playback
The time bar below the video image allows quick orientation. The time interval associated with the sequence is displayed in the bar in gray. Arrows indicate the position of the image currently being played back within the sequence. The time bar offers various options for navigation in and between sequences. – If required, click in the bar at the point in time at which the playback should begin. – Change the time interval displayed by clicking the plus or minus icons or use the mouse
scroll wheel. The display can span a range from six months to one minute.
Click the alarm jump buttons to go from one alarm event to the next or to the previous
one. Red bars indicate the points in time where alarms were triggered.
Controls
Control playback by means of the buttons below the video image. The buttons have the following functions: – Start/Pause playback – Select the playback (forward or backward) speed using the speed regulator – Step forward or backward frame-by-frame when paused (small arrows)
14 en | General
AUTODOME IP 5000i IR
2018.05 | 1.1 | User Manual Bosch Security Systems
4 General
4.1 Identification
Device name
Enter a unique, unambiguous name for the device (for example, the installation location of the device). This name should be easy to identify in a list of devices in your system. The device name is used for the remote identification of a unit, such as in the event of an alarm. Do not use any special characters, for example &, in the name. Special characters are not supported by the system's internal management.
Device ID
Enter a unique identifier for the device. This ID is additional identification for the device.
Initiator extension
Add text to an initiator name to make identification easier in large iSCSI systems. This text is added to the initiator name, separated from it by a full stop. (You can see the initiator name in the System Overview page.)
4.2 User Management
The section Allowed authentication modes provides information about the authentication modes set in the camera. A checkmark appears in the checkbox to the left of the mode if the mode is set. If the mode is not set, the phrase, “No certificate installed” appears to the right of the mode name.
Password
This field indicates if a password is set for the camera.
Certificate
A check mark in this check box indicates that at least one certificate is loaded onto the camera. If no certificates are loaded, then “No certificate installed” appears to the right of the text. The Escrypt certificate is a root certificate for Bosch Security Systems that proves that the device meets the following criteria: – It originates from a Bosch factory that is a secure environment. – It has not been tampered with. Escrypt is a Bosch company and Certificate Authority (CA).
Active directory server (ADFS)
A check mark in this check box indicates that the camera uses an active directory server. If the camera does not use ADFS, then “No certificate installed” appears to the right of the text.
Password management
A password prevents unauthorized access to the device. You can use different authorization levels to limit access. Proper password protection is only guaranteed when all higher authorization levels are also protected with a password. Therefore, you must always start from the highest authorization level when assigning passwords. You can define and change a password for each authorization level if you are logged into the “service” user account. The device has three authorization levels: service, user, and live. – service is the highest authorization level. Entering the correct password gives access to
all the functions and allows all configuration settings to be changed.
General | en 15
Bosch Security Systems User Manual 2018.05 | 1.1 |
user is the middle authorization level. At this level you can operate the device, play back
recordings, and also control camera, for example, but you cannot change the configuration.
live is the lowest authorization level. At this level you can only view the live video image
and switch between the different live image displays.
To edit a password To edit a password, click the pencil icon to the right of the column Type for the appropriate User name.
To create a new user
To create a new user, click Add. In the box User, fill in the fields. For Group, select the appropriate authorization level. For Type, select either Password (for a new password) or Certificate (for a certificate that the new user is authorized to use).
Note: Use a maximum of 19 characters. Do no use special characters.
Confirm password
In each case, enter the new password a second time to eliminate typing mistakes.
Notice! A new password is only saved when you click the Set button. You should therefore click the Set button immediately after entering and confirming a password.
4.3 Date/Time
Date format
Select your required date format.
Device date/Device time
Notice!
Ensure that recording is stopped before synching to the PC.
If there are multiple devices operating in your system or network, it is important to synchronize their internal clocks. For example, it is only possible to identify and correctly evaluate simultaneous recordings when all units are operating on the same time.
1. Enter the current date. Since the unit time is controlled by the internal clock, there is no need to enter the day of the week – it is added automatically.
2. Enter the current time or click the Sync to PC button to copy your computer's system time to the camera.
Note: It is important that the date/time is correct for recording. An incorrect date/time setting could prevent correct recording.
Device time zone
Select the time zone in which your system is located.
Daylight saving time
The internal clock can switch automatically between normal and daylight saving time (DST). The unit already contains the data for DST switch-overs for many years in advance. If the date, time and zone have been set up correctly, a DST table is automatically created.
16 en | General
AUTODOME IP 5000i IR
2018.05 | 1.1 | User Manual Bosch Security Systems
If you decide to create alternative daylight saving time dates by editing the table, note that values occur in linked pairs (DST start and end dates).
First, check the time zone setting. If it is not correct, select the appropriate time zone and click Set.
1. Click Details to edit the DST table.
2. Select the region or the city which is closest to the system's location from the list box below the table.
3. Click Generate to fill the table with the preset values from the unit.
4. Click one of the entries in the table to make changes. The entry is highlighted.
5. Click Delete to remove the entry from the table.
6. Choose other values from the list boxes under the table, to change the selected entry. Changes are immediate.
7. If there are empty lines at the bottom of the table, for example after deletions, add new data by marking the row and selecting values from the list boxes.
8. When finished, click OK to save and activate the table.
Time server IP address
The camera can receive the time signal from a time server using various time server protocols, and then use it to set the internal clock. The unit polls the time signal automatically once every minute. Enter the IP address of a time server here.
Time server type
Select the protocol that is supported by the selected time server. Preferably, you should select the SNTP server as the protocol. This supports a high level of accuracy and is required for special applications and subsequent function extensions. Select Time server for a time server that works with the protocol RFC868.
4.4 Display Stamping
Various overlays or “stamps” in the video image provide important supplementary information. These overlays can be enabled individually and are arranged on the image in a clear manner.
Camera name stamping This field sets the position of the camera name overlay. It can be displayed at the Top, at the Bottom or at a position of your choice that you can then specify using the Custom option. Or
it can be set to Off for no overlay information.
1. Select the desired option from the list.
2. If you select the Custom option, additional fields are displayed where you can specify the exact position (Position (XY)).
3. In the Position (XY) fields, enter the values for the desired position.
Logo
To place a logo on the image, select and upload an uncompressed .bmp file with a maximum size of 128x128 pixels and 256 colors to the camera. Its position on the image can then be selected.
Logo position Select the position for the logo on the OSD: To the left of the name, To the right of the name, or Logo only. Select Off (the default value) to disable logo positioning.
General | en 17
Bosch Security Systems User Manual 2018.05 | 1.1 |
Time stamping
This field sets the position of the time overlay. It can be displayed at the Top, at the Bottom or at a position of your choice that you can then specify using the Custom option. Or it can be set to Off for no overlay information.
1. Select the desired option from the list.
2. If you select the Custom option, additional fields are displayed where you can specify the exact position (Position (XY)).
3. In the Position (XY) fields, enter the values for the desired position.
Display milliseconds
If necessary, you can also display milliseconds. This information can be useful for recorded video images; however, it does increase the processor's computing time. Select Off if you do not need to display milliseconds.
Live video indicator
Select On to display the Live video indicator, an icon that pulses on the OSD to show that the video stream is live. Select Off to hide the Live video indicator.
Alarm mode stamping
Select On to display a text message overlay in the image in the event of an alarm. It can be displayed at a position of your choice that you can then specify using the Custom option. Or it can be set to Off for no overlay information.
1. Select the desired option from the list.
2. If you select the Custom option, additional fields are displayed where you can specify the exact position (Position (XY)).
3. In the Position (XY) fields, enter the values for the desired position.
Alarm message
Enter the message to be displayed in the image in the event of an alarm. The maximum text length is 31 characters.
Title OSD
OSD titles can be displayed at a position of your choice. Select On to display sector or pre-position title overlays continuously in the image. Select Momentary to display sector or pre-position title overlays for a few seconds.
1. Select the desired option from the list.
2. Specify the exact position (Position (XY)).
3. In the Position (XY) fields, enter the values for the desired position.
Select Off to deactivate the display of overlay information.
Camera OSD
Select On to momentarily display camera response information, such as Digital Zoom, Iris open/close, and Focus near/far overlays in the image. Select Off to display no information.
1. Select the desired option from the list.
2. Specify the exact position (Position (XY)).
3. In the Position (XY) fields, enter the values for the desired position.
Title region
Select On to set or to edit the position of the title region on the OSD. The fields Position (XY) and (0...255) appear.
1. In the field Position (XY), specify the exact position. (The default is 10.)
2. In the field (0...255), enter the position range. (The default is 176).
Select Off to hide the region from view.
18 en | General
AUTODOME IP 5000i IR
2018.05 | 1.1 | User Manual Bosch Security Systems
Telemetry region
Select On to set or to edit the position of the telemetry information (azimuth and elevation (pan/tilt position)) and the zoom factor on the OSD. Refer to the section ”PTZ Settings, page 37“ to set the pan and tilt limits. The fields Position (XY) and (0...255) appear.
1. In the field Position (XY), specify the exact position. (The default is 10.)
2. In the field (0...255), enter the position range. (The default is 176). Select Off to hide the region from view.
Feedback region
Select On to set or to edit the position of system feedback messages (including message for camera settings such as focus, iris, and zoom level) on the OSD. Refer to the section “Lens Settings” to configure these settings. The fields Position (XY) and (0...255) appear.
1. In the field Position (XY), specify the exact position. (The default is 10.)
2. In the field (0...255), enter the position range. (The default is 176). Select Off to hide the region from view.
Transparent background
Check this box to make transparent the stamp background on the image.
Stamping size Select the desired font size of the overlays on the OSD: Normal or Big.
Video authentication
Select from the Video authentication drop-down box a method for verifying the integrity of the video. If you select Watermarking, all images are marked with an icon. The icon indicates if the sequence (live or saved) has been manipulated. If you want to add a digital signature to the transmitted video images to ensure their integrity, select one of the cryptographic algorithms for this signature.
Signature interval [s]
For certain Video authentication modes, enter the interval (in seconds) between insertions of the digital signature.
4.5 GB/T 28181
This page allows you to set the parameters for conformance to the GB/T28181 national standard “Security and protection video monitoring network system for information transport, switch and control”. This standard is specifically for China.
Enable
Select this checkbox to enable the system to use the other parameters on this page in accordance with the GB/T 28181 national standard.
H.264 elementary stream
Select this checkbox to select or to enable the H.264 elementary stream.
Registration timeout
Enter a value (in milliseconds) for the registration timeout. The default is 3600.
Heartbeat timeout
Enter the value (in seconds) for the heartbeat timeout. The default is 15.
Server ID
Enter the ID of the server.
General | en 19
Bosch Security Systems User Manual 2018.05 | 1.1 |
Server IP address
Enter the server IP address.
Device ID
Enter the ID of the device.
Device port
Enter the number of the device port. The default is 5060.
Password
Enter the appropriate password.
Alarm device ID
Enter the ID of the alarm device.
20 en | Web Interface
AUTODOME IP 5000i IR
2018.05 | 1.1 | User Manual Bosch Security Systems
5 Web Interface
5.1 Appearance
You can adapt the appearance of the web interface and change the website language to meet your requirements. GIF or JPEG images can be used to replace the company and device logos. The image can be stored on a web server (for example, http://www.myhostname.com/images/logo.gif). Ensure that a connection to the web server is always available to display the image. The image files are not stored on the unit. To restore the original graphics, delete the entries in the Company logo and Device logo fields.
Website language
Select the language for the user interface. The default language is English. After selecting a different language, click the Set button. The page refreshes automatically. The GUI now displays field names and options as well as OSD messages in the selected language.
Company logo
To replace the company's logo in the top-right part of the window, enter the path to a suitable image in this field. The image file must be stored on a web server.
Device logo
To replace the device name in the top-left part of the window, enter the path to a suitable image in this field. The image file must be stored on a web server.
Notice! If you want to use the original image again, delete the entries in the fields Company logo and Device logo.
Show VCA metadata
When video content analysis (VCA) is activated, additional information is displayed in the live video stream. With the MOTION+ analysis type, for example, the sensor fields in which motion is recorded are marked with yellow rectangles. Using EssentialVideoAnalytics or IntelligentVideoAnalytics, the outlines of detected objects are displayed in following colors: – Red: Objects that generate an alarm event under the current settings appear on the
camera image inside a red outline.
Orange: An object that has triggered one alarm event but does not generate another
appears inside an orange outline (example: object has crossed a line). During forensic search, an object that triggers an alarm event has an orange outline from the beginning.
Yellow: Objects that are detected as moving but do not generate an alarm event under
the current settings appear inside a yellow outline.
Show VCA trajectories
(Only for certain cameras) The trajectories (motion lines of objects) from the video content analysis are displayed in the live video image if a corresponding analysis type is activated. The trajectory is shown as a green line following the object base point.
Show overlay icons
Select this check box to show overlay icons on the live video image.
Web Interface | en 21
Bosch Security Systems User Manual 2018.05 | 1.1 |
Show VCA items
Shows alarm fields, lines and routes configured for the video analytics in the following colors: – Green: Fields, lines and routes used in a task are displayed in green. They can be edited
but not deleted.
Red: Fields, lines and routes currently in alarm mode are displayed in red.
Latency mode
Select the required latency mode: – Low delay: Default mode. Provides marginal buffering to display fluent video under
normal network conditions.
Smooth video: Allows the buffer to automatically adjust to cover network jitter, inducing
higher latency.
Unbuffered: Displays video as it is received by the decoder with minimum latency. Allows
the video to jerk if there is network jitter.
JPEG resolution You can specify the size of the JPEG image on the Live page. Options are Small, Medium, Large, 720p, 1080p, and “Best possible” (default).
JPEG interval
You can specify the interval at which the individual images should be generated for the M­JPEG image on the Live page.
JPEG quality You can specify the quality at which the JPEG images appear on the Live page.
5.2 LIVE Functions
On this page you can adapt the functions on the LIVE page to your requirements. You can choose from a variety of different options for displaying information and controls.
1. Check the box for the items that are to be made available on the LIVE page. The selected items are indicated by a check mark.
2. Check whether the required functions are available on the LIVE page.
Transmit audio
You can only select this option if audio transmission is actually switched on (see Audio).The audio signals are sent in a separate data stream parallel to the video data, and so increase the network load. The audio data are encoded according to G.711 and require an additional bandwidth of approx. 80 kbps per connection in each direction.
Lease time (s)
The lease time in seconds determines the time beyond which a different user is authorized to control the camera after no further control signals are received from the current user. After this time interval, the camera is automatically enabled for another user.
Show alarm inputs Select this checkbox if you want the alarm inputs to appear in the Digital I/O section of the Live page.
Show alarm outputs Select this checkbox if you want the alarm outputs to appear in the Digital I/O section of the Live page.
Allow snapshots
Here you can specify whether the icon for saving individual images (snapshots) should be displayed below the live image. Individual images can only be saved if this icon is visible.
Loading...