Upflow/ Horizontal Left,
Downflow/ Horizontal Right
Variable Speed
Two Stage Condensing
Gas-Fired Furnace
XV 95
TUH2B060A9V3VA TDH2B060A9V3VA
TUH2B080A9V3VA TDH2B080A9V3VA
TUH2B080A9V4VA TDH2B080A9V4VA
TUH2C100A9V4VA TDH2C100A9V4VA
TUH2C100A9V5VA TDH2D120A9V5VA
TUH2D120A9V5VA
Direct Vent with
Variable Speed Blower
Variable Speed Inducer
*UH-A9V-V |
*DH-A9V-V |
DOWNFLOW
UPFLOW
UPFLOW/HORIZONTAL |
DOWNFLOW/HORIZONTAL |
PUB. NO. 22-1814-08
General
Features
NATURAL GAS MODELS
Central Heating furnace designs are certified by the American Gas Association for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards.
SAFE OPERATION
The Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide additional safety.
QUICK HEATING
Durable, cycle tested, heavy gauge aluminized steel heat exchanger quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower, to increase efficiency and provide a positive discharge of gas fumes to the outside.
BURNERS
Multiport Inshot burners will give years of quiet and efficient service. All models can be converted to L.P. gas without changing burners.
INTEGRATED SYSTEM CONTROL
Exclusively designed operational program provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains connection points for E.A.C./Humidifier.
AIR DELIVERY
The variable speed blower motor has sufficient airflow for most heating and cooling requirements and will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed.
SECONDARY HEAT EXCHANGER
The XV95 has a special type 294C™ stainless steel secondary heat exchanger to reclaim heat from flue gases which would normally be lost instead.
STYLING
Heavy gauge steel and “wraparound” cabinet construction is used in the cabinet with baked-on enamel finish for strength and beauty. The heat exchanger section of the cabinet is completely lined with foil faced fiberglass insulation. This results in quiet and efficient operation due to the excellent acoustical and insulating qualities of fiberglass. Built-in bottom pan and alternate bottom, left or right side return air connection provision.
FEATURES AND GENERAL OPERATION
The XV95 High Efficiency Gas Furnaces utilize an Adaptive Heat Up Silicon Nitride Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access.
a.Low energy power venter
b.Vent proving pressure switch.
© 2012 Trane |
All Rights Reserved |
2 |
Pub. No. 22-1814-08 |
Contents
General Features |
|
|
2 |
||
Features and Benefits |
|
|
|
4 |
|
Standard Equipment |
|
|
|
4 |
|
Optional Equipment |
|
|
|
5 |
General Data |
|
6- |
TUH2B060A9V3VA
TUH2B080A9V3VA
TUH2B080A9V4VA
TUH2C100A9V4VA
TUH2C100A9V5VA
TUH2D120A9V5VA
TDH2B060A9V3VA
TDH2B080A9V3VA
TDH2B080A9V4VA
TDH2C100A9V4VA
TDH2D120A9V5VA
Performance Data |
9-19 |
Venting Table |
20 |
Electrical Data |
21-24 |
Field Wiring |
25-26 |
Dimensions |
27-28 |
|
|
Pub. No. 22-1814-08 |
3 |
Features
and Benefits
XV 95 STANDARD EQUIPMENT
•Variable Speed Blower Motor
•Silicon Nitride Igniter with adaptive heat up
•Variable speed induced draft blower
•Direct/Non-Direct vent option
•Fused 24 volt control circuit
•Manual reset burner safety switches
•Power supply 115/1/60
•Convertible to horizontal on left side
•2-stage gas valve
•PVC venting-1 or 2 pipe option
•Accessory hook-up capability
•Integrated solid state control with selfdiagnostics
•Attractive color accents
•Heavy gauge aluminized steel heat exchanger
•Multi-port In-shot burners
•Quiet induced draft blower
•Lite Port™ extended system diagnostics
•Stored fault code history in micro processor nonvocatile memory
•Cleanable high velocity filters (upflow only)
•Hinged blower door *
•Perfect fit door latches*
•Insulated blower door*
•Gasketed blower door*
•Complete front service access
•Left/right gas connection
•Adjustable fan off times
•Optional L.P conversion kit
•Selectable cooling fan off delay eliminates need for BAY24X045 time delay kit
* (Upflow only)
4 |
Pub. No. 22-1814-08 |
Features
and Benefits
XV 95 OPTIONAL EQUIPMENT |
|
|
Thermostat, 2-Stage Heat / 1-Stage Cooling............................................................................................................ |
TAYSTAT241 [ |
] |
Thermostat, Media Programmable 2-Stage Heating............................................................................................... |
TAYSTAT302C [ ] |
|
Thermostat, Mechanical Heating Only With Fan Switch......................................................................................... |
TAYSTAT303C [ ] |
|
Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) ............................................................................... |
AY28X092 [ ] |
|
Thermostat, Heating/Cooling Single Stage (Mounts Vertically)................................................................................ |
BAYSTAT305 [ ] |
|
Thermostat, Media Programmable 1-Stage Heating/1-Stage Cooling.................................................................... |
TAYSTAT300C [ ] |
|
Propane Conversion Kit........................................................................................................................................ |
BAYLPKT210A [ ] |
|
Media Air Filter, “Perfect Fit” High Efficiency (14-1/2" Wide Gas Furnace)........................................................... |
TFM145A9FR0 [ ] |
|
Media Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace)........................................................... |
TFM175A9FR0 [ |
] |
Media Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace).................................................................. |
TFM210A9FR0 [ ] |
|
Media Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace)........................................................... |
TFM245A9FR0 [ ] |
|
Media Air Filter, “Perfect Fit” Standard Efficiency (14-1/2" Wide Gas Furnace)..................................................... |
TFP145A9FR0 [ ] |
|
Media Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace)..................................................... |
TFP175A9FR0 [ |
] |
Media Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace)........................................................... |
TFP210A9FR0 [ ] |
|
Media Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace)..................................................... |
TFP245A9FR0 [ ] |
|
Coil Enclosure (14-1/2" Wide Cabinets).......................................................................................................... |
BAYCLE14A1422A [ ] |
|
Coil Enclosure (17-1/2" Wide Cabinets) ........................................................................................................ |
BAYCLE17A1722A [ ] |
|
Coil Enclosure (21" Wide Cabinets) ............................................................................................................... |
BAYCLE21A2130A [ ] |
|
Coil Enclosure (24-1/2" Wide Cabinets) ........................................................................................................ |
BAYCLE24A2430A [ ] |
|
Downflow Subbase.................................................................................................................................................. |
BAYBASE205 [ ] |
|
Side Filter Rack........................................................................................................................................................ |
BAYFLTR200 [ |
] |
Filter Kit/Horizontal Conversion TUH2-060,080....................................................................................................... |
BAYFLTR203 [ |
] |
Filter Kit/Horizontal Conversion TUH2-100.............................................................................................................. |
BAYFLTR204 [ |
] |
Filter Kit/Horizontal Conversion TUH2-120.............................................................................................................. |
BAYFLTR205 [ |
] |
High Altitude Pressure Switch Kit TUH2-060 ............................................................................................ |
BAYSWT10AHALTA1 [ ] |
|
High Altitude Pressure Switch Kit TUH2-080,100,120 .............................................................................. |
BAYSWT08AHALTA1 [ ] |
|
Concentric Vent Kit TUH2 Furnaces............................................................................................................... |
BAYAIR30AVENTA [ ] |
|
Sidewall Vent Termination Kit All 2 Pipe Direct Vent Furnaces............................................................................. |
BAYVENT200B [ |
] |
Manufactured/Mobile Home Kit All 2 Pipe Direct Vent Furnaces........................................................................ |
BAYMFGH100A [ ] |
|
Cleanable Filter (14.5"/17.5" wide Upflow models).................................................................................................. |
BAYFLTR317 [ |
] |
Cleanable Filter (21" wide Upflow models).............................................................................................................. |
BAYFLTR321 [ ] |
|
Cleanable Filter (24.5" wide Upflow models)........................................................................................................... |
BAYFLTR324 [ ] |
|
CleanEffects™, Whole House Air Cleaner (Upflow 14-1/2" Wide Gas Furnace)............................................ |
TFD145ALFR000B [ ] |
|
CleanEffects™, Whole House Air Cleaner (Upflow 17-1/2" Wide Gas Furnace) ............................................ |
TFD175ALFR000B [ |
] |
CleanEffects™, Whole House Air Cleaner (Upflow 21" Wide Gas Furnace) .................................................. |
TFD210ALFR000B [ ] |
|
CleanEffects™, Whole House Air Cleaner (Upflow 24-1/2" Wide Gas Furnace) ............................................ |
TFD245ALFR000B [ ] |
|
CleanEffects™, Whole House Air Cleaner (Downflow 14-1/2" Wide Gas Furnace) ....................................... |
TFD14DALFR000B [ ] |
|
CleanEffects™, Whole House Air Cleaner (Downflow 17-1/2" Wide Gas Furnace) ....................................... |
TFD17DALFR000B [ |
] |
CleanEffects™, Whole House Air Cleaner (Downflow 21" Wide Gas Furnace) ............................................. |
TFD21DALFR000B [ ] |
|
CleanEffects™, Whole House Air Cleaner (Downflow 24-1/2" Wide Gas Furnace) ....................................... |
TFD24DALFR000B [ ] |
|
CleanEffects™, Whole House Transformer Kit (120 to 24 Volt - all TFD Air Cleaners)..................................... |
BAYTRANS12024 [ ] |
1 Optional kit allows 200 ft. max. vent length from 5,000-12,000 feet above sea level. See installer's guide.
Pub. No. 22-1814-08 |
5 |
General
Data
TUH2 PRODUCT SPECIFICATIONS1
Product Specifications 1
MODEL |
TUH2B060A9V3VA |
TUH2B080A9V3VA |
TUH2B080A9V4VA |
TUH2C100A9V4VA |
TYPE |
Upflow / Horizontal |
Upflow / Horizontal |
Upflow / Horizontal |
Upflow / Horizontal |
RATINGS 2 |
|
52,000 |
|
|
1st Stage Input BTUH |
39,000 |
52,000 |
65,000 |
|
1st Stage Capacity BTUH (ICS) 3 |
37,830 |
50,440 |
50,440 |
62,855 |
2nd Stage Input BTUH |
60,000 |
80,000 |
80,000 |
100,000 |
2nd Stage Capacity BTUH (ICS) 3 |
58,200 |
77,600 |
77,600 |
96,700 |
AFUE |
97 |
97 |
97 |
96.7 |
Temp. rise (Min.-Max.) °F. |
35 - 65 |
35 - 65 |
35 - 65 |
35 - 65 |
BLOWER DRIVE |
DIRECT |
DIRECT |
DIRECT |
DIRECT |
Diameter - Width (In.) |
10 x 8 |
10 x 8 |
11 x 8 |
10 x 10 |
No. Used |
1 |
1 |
1 |
1 |
Speeds (No.) |
Variable |
Variable |
Variable |
Variable |
CFM vs. in. w.g. |
See Fan Performance Table |
See Fan Performance Table |
See Fan Performance Table |
See Fan Performance Table |
Motor HP |
1/2 |
1/2 |
3/4 |
3/4 |
R.P.M. |
Variable |
Variable |
Variable |
Variable |
Volts / Ph / Hz |
115/1/60 |
115/1/60 |
115/1/60 |
115/1/60 |
COMBUSTION FAN - Type |
Centrifugal |
Centrifugal |
Centrifugal |
Centrifugal |
Drive - No. Speeds |
Direct - Variable |
Direct - Variable |
Direct - Variable |
Direct - Variable |
Motor HP - RPM |
1/50 - 5000 |
1/50 - 5000 |
1/50 - 5000 |
1/50 - 5000 |
Volts / Ph / Hz |
33 - 110/3/60 - 180 |
33 - 110/3/60 - 180 |
33 - 110/3/60 - 180 |
33 - 110/3/60 - 180 |
FLA |
1.0 |
1.0 |
1.0 |
1.0 |
FILTER — Furnished? |
Yes |
Yes |
Yes |
Yes |
Type Recommended |
High Velocity |
High Velocity |
High Velocity |
High Velocity |
Hi Vel. (No.-Size-Thk.) |
1 - 17x25 - 1 in. |
1 - 17x25 - 1 in. |
1 - 17x25 - 1 in. |
1 - 20x25 - 1 in. |
VENT — Size (in.) |
2 Round |
2 Round |
2 Round |
3 Round |
HEAT EXCHANGER |
|
Aluminized Steel - Type I |
|
|
Type -Fired |
Aluminized Steel - Type I |
Aluminized Steel - Type I |
Aluminized Steel - Type I |
|
-Unfired |
|
20 |
|
|
Gauge (Fired) |
20 |
20 |
20 |
|
ORIFICES — Main |
|
4 — 45 |
|
|
Nat. Gas. Qty. — Drill Size |
3 — 45 |
4 — 45 |
5 — 45 |
|
L.P. Gas Qty. — Drill Size |
3 — 56 |
4 — 56 |
4 — 56 |
5 — 56 |
GAS VALVE |
Redundant - Two Stage |
Redundant - Two Stage |
Redundant - Two Stage |
Redundant - Two Stage |
PILOT SAFETY DEVICE |
|
Hot Surface Igniter |
|
|
Type |
Hot Surface Igniter |
Hot Surface Igniter |
Hot Surface Igniter |
|
BURNERS — Type |
Multiport Inshot |
Multiport Inshot |
Multiport Inshot |
Multiport Inshot |
Number |
3 |
4 |
4 |
5 |
POWER CONN. — V / Ph / Hz 4 |
115/1/60 |
115/1/60 |
115/1/60 |
115/1/60 |
Ampacity (In Amps) |
11.1 |
11.1 |
13.5 |
13.5 |
Max. Overcurrent Protection (Amps) |
15 |
15 |
20 |
20 |
PIPE CONN. SIZE (IN.) |
1/2 |
1/2 |
1/2 |
1/2 |
DIMENSIONS |
H x W x D |
H x W x D |
H x W x D |
H x W x D |
Crated (In.) |
41-3/4 x 19-1/2 x 30-1/2 |
41-3/4 x 19-1/2 x 30-1/2 |
41-3/4 x 19-1/2 x 30-1/2 |
41-3/4 x 23 x 30-1/2 |
WEIGHT |
|
168 / 156 |
|
|
Shipping (Lbs.) / Net (Lbs) |
158 / 146 |
170 / 158 |
197 / 185 |
1Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3
2For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3Based on U.S. government standard tests.
4The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
6 |
Pub. No. 22-1814-08 |
General
Data
TUH2/TDH2 PRODUCT SPECIFICATIONS1
PRODUCT SPECIFICATIONS 1
MODEL |
TUH2C100A9V5VA |
TUH2D120A9V5VA |
TDH2B060A9V3VA |
TDH2B080A9V3VA |
TYPE |
Upflow / Horizontal |
Upflow / Horizontal |
Downflow / Horizontal |
Downflow / Horizontal |
RATINGS 2 |
|
|
|
|
1st Stage Input BTUH |
65,000 |
78,000 |
39,000 |
52,000 |
1st Stage Capacity BTUH (ICS) 3 |
62,855 |
75,426 |
37,000 |
49,400 |
2nd Stage Input BTUH |
100,000 |
120,000 |
60,000 |
80,000 |
2nd Stage Capacity BTUH (ICS) 3 |
96,700 |
116,040 |
57,000 |
76,000 |
AFUE |
96.7 |
96.7 |
95 |
95 |
Temp. rise (Min.-Max.) °F. |
35 - 65 |
40 - 70 |
35 - 65 |
35 - 65 |
BLOWER DRIVE |
DIRECT |
DIRECT |
DIRECT |
DIRECT |
Diameter - Width (In.) |
11 x 10 |
10 x 10 |
10 x 8 |
10 x 8 |
No. Used |
1 |
1 |
1 |
1 |
Speeds (No.) |
Variable |
Variable |
Variable |
Variable |
CFM vs. in. w.g. |
See Fan Performance Table |
See Fan Performance Table |
See Fan Performance Table |
See Fan Performance Table |
Motor HP |
1 |
1 |
1/2 |
1/2 |
R.P.M. |
Variable |
Variable |
Variable |
Variable |
Volts / Ph / Hz |
115/1/60 |
115/1/60 |
115/1/60 |
115/1/60 |
COMBUSTION FAN - Type |
Centrifugal |
Centrifugal |
Centrifugal |
Centrifugal |
Drive - No. Speeds |
Direct - Variable |
Direct - Variable |
Direct - Variable |
Direct - Variable |
Motor HP - RPM |
1/50 - 5000 |
1/50 - 5000 |
1/50 - 5000 |
1/50 - 5000 |
Volts / Ph / Hz |
33 - 110/3/60 - 180 |
33 - 110/3/60 - 180 |
33 - 110/3/60 - 180 |
33 - 110/3/60 - 180 |
FLA |
1.0 |
1.0 |
1.0 |
1.0 |
FILTER — Furnished? |
Yes |
Yes |
Yes |
Yes |
Type Recommended |
High Velocity |
High Velocity |
High Velocity |
High Velocity |
Hi Vel. (No.-Size-Thk.) |
1 - 20x25 - 1 in. |
1 - 24x25 - 1 in. |
2 - 14x20 - 1 in. |
2 - 14x20 - 1 in. |
VENT — Size (in.) |
3 Round |
3 Round |
2 Round |
2 Round |
HEAT EXCHANGER |
|
|
|
|
Type -Fired |
Aluminized Steel - Type I |
Aluminized Steel - Type I |
Aluminized Steel - Type I |
Aluminized Steel - Type I |
-Unfired |
|
|
|
|
Gauge (Fired) |
20 |
20 |
20 |
20 |
ORIFICES — Main |
|
|
|
|
Nat. Gas. Qty. — Drill Size |
5 — 45 |
6 — 45 |
3 — 45 |
4 — 45 |
L.P. Gas Qty. — Drill Size |
5 — 56 |
6 — 56 |
3 — 56 |
4 — 56 |
GAS VALVE |
Redundant - Two Stage |
Redundant - Two Stage |
Redundant - Two Stage |
Redundant - Two Stage |
PILOT SAFETY DEVICE |
|
|
|
|
Type |
Hot Surface Igniter |
Hot Surface Igniter |
Hot Surface Igniter |
Hot Surface Igniter |
BURNERS — Type |
Multiport Inshot |
Multiport Inshot |
Multiport Inshot |
Multiport Inshot |
Number |
5 |
6 |
3 |
4 |
POWER CONN. — V / Ph / Hz 4 |
115/1/60 |
115/1/60 |
115/1/60 |
115/1/60 |
Ampacity (In Amps) |
16.3 |
15.2 |
11.1 |
11.1 |
Max. Overcurrent Protection (Amps) |
20 |
20 |
15 |
15 |
PIPE CONN. SIZE (IN.) |
1/2 |
1/2 |
1/2 |
1/2 |
DIMENSIONS |
H x W x D |
H x W x D |
H x W x D |
H x W x D |
Crated (In.) |
41-3/4 x 23 x 30-1/2 |
41-3/4 x 26-1/2 x 30-1/2 |
41-3/4 x 19-1/2 x 30-1/2 |
41-3/4 x 19-1/2 x 30-1/2 |
WEIGHT |
|
|
|
|
Shipping (Lbs.) / Net (Lbs) |
199 / 187 |
206 / 193 |
160/ 146 |
168 / 158 |
1Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3
2For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3Based on U.S. government standard tests.
4The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
Pub. No. 22-1814-08 |
7 |
General
Data
TDH2 PRODUCT SPECIFICATIONS1
PRODUCT SPECIFICATIONS 1
MODEL |
TDH2B080A9V4VA |
TDH2C100A9V4VA |
TDH2D120A9V5VA |
TYPE |
Downflow / Horizontal |
Downflow / Horizontal |
Downflow / Horizontal |
RATINGS 2 |
|
|
|
1st Stage Input BTUH |
52,000 |
65,000 |
78,000 |
1st Stage Capacity BTUH (ICS) 3 |
49,400 |
61,750 |
74,000 |
2nd Stage Input BTUH |
80,000 |
100,000 |
120,000 |
2nd Stage Capacity BTUH (ICS) 3 |
76,000 |
95,000 |
114,000 |
AFUE |
95 |
95 |
95 |
Temp. rise (Min.-Max.) °F. |
35 - 65 |
35 - 65 |
40 - 70 |
BLOWER DRIVE |
DIRECT |
DIRECT |
DIRECT |
Diameter - Width (In.) |
11 x 8 |
10 x 10 |
10 x 10 |
No. Used |
1 |
1 |
1 |
Speeds (No.) |
Variable |
Variable |
Variable |
CFM vs. in. w.g. |
See Fan Performance Table |
See Fan Performance Table |
See Fan Performance Table |
Motor HP |
3/4 |
3/4 |
1 |
R.P.M. |
Variable |
Variable |
Variable |
Volts / Ph / Hz |
115/1/60 |
115/1/60 |
115/1/60 |
COMBUSTION FAN - Type |
Centrifugal |
Centrifugal |
Centrifugal |
Drive - No. Speeds |
Direct - Variable |
Direct - Variable |
Direct - Variable |
Motor HP - RPM |
1/50 - 5000 |
1/50 - 5000 |
1/50 - 5000 |
Volts / Ph / Hz |
33 - 110/3/60 - 180 |
33 - 110/3/60 - 180 |
33 - 110/3/60 - 180 |
FLA |
1.0 |
1.0 |
1.0 |
FILTER — Furnished? |
Yes |
Yes |
Yes |
Type Recommended |
High Velocity |
High Velocity |
High Velocity |
Hi Vel. (No.-Size-Thk.) |
2 - 14x20 - 1 in. |
2 - 16x20 - 1 in. |
2 - 16x20 - 1 in. |
VENT — Size (in.) |
2 Round |
3 Round |
3 Round |
HEAT EXCHANGER |
|
|
|
Type -Fired |
Aluminized Steel - Type I |
Aluminized Steel - Type I |
Aluminized Steel - Type I |
-Unfired |
|
|
|
Gauge (Fired) |
20 |
20 |
20 |
ORIFICES — Main |
|
|
|
Nat. Gas. Qty. — Drill Size |
4 — 45 |
5 — 45 |
6 — 45 |
L.P. Gas Qty. — Drill Size |
4 — 56 |
5 — 56 |
6 — 56 |
GAS VALVE |
Redundant - Two Stage |
Redundant - Two Stage |
Redundant - Two Stage |
PILOT SAFETY DEVICE |
|
|
|
Type |
Hot Surface Igniter |
Hot Surface Igniter |
Hot Surface Igniter |
BURNERS — Type |
Multiport Inshot |
Multiport Inshot |
Multiport Inshot |
Number |
4 |
5 |
6 |
POWER CONN. — V / Ph / Hz 4 |
115/1/60 |
115/1/60 |
115/1/60 |
Ampacity (In Amps) |
13.5 |
13.5 |
15.2 |
Max. Overcurrent Protection (Amps) |
20 |
20 |
20 |
PIPE CONN. SIZE (IN.) |
1/2 |
1/2 |
1/2 |
DIMENSIONS |
H x W x D |
H x W x D |
H x W x D |
Crated (In.) |
41-3/4 x 19-1/2 x 30-1/2 |
41-3/4 x 23 x 30-1/2 |
41-3/4 x 26-1/2 x 30-1/2 |
WEIGHT |
|
|
|
Shipping (Lbs.) / Net (Lbs) |
172 / 160 |
185 / 175 |
206 / 196 |
8 |
Pub. No. 22-1814-08 |
*UH2B060A9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
|
|
|
|
|
|
|
|
|
|
|
|
1st Stage Capacity = |
37,830 |
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
2nd Stage Capacity = |
58,200 |
|
|
|
|
|
|
|
|||
|
AIRFLOW |
DIP SWITCH SETTING |
|
|
|
|
|
|
|
EXTERNAL STATIC PRESSURE |
|
||||||||||||
|
SETTING |
|
SW 7 |
|
SW 8 |
|
|
|
|
|
0.1 |
|
0.3 |
|
0.5 |
|
|
0.7 |
|
|
0.9 |
||
|
|
|
|
|
|
|
|
|
CFM |
|
600 |
|
600 |
|
600 |
|
|
600 |
|
|
|
||
|
LOW |
|
ON |
|
ON |
|
TEMP. RISE |
|
57 |
|
57 |
|
57 |
|
|
57 |
|
|
- |
||||
|
|
|
|
|
|
|
|
WATTS |
|
85 |
|
110 |
|
155 |
|
|
190 |
|
|
|
|||
|
|
|
|
|
|
|
|
|
CFM |
|
700 |
|
700 |
|
700 |
|
|
700 |
|
|
|
||
HEATING |
MEDIUM LOW |
|
OFF |
|
ON |
|
TEMP. RISE |
|
49 |
|
49 |
|
49 |
|
|
49 |
|
|
- |
||||
|
|
|
|
|
|
|
WATTS |
|
90 |
|
130 |
|
175 |
|
|
210 |
|
|
|
||||
1ST |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
CFM |
|
775 |
|
775 |
|
775 |
|
|
775 |
|
|
|
|||
STAGE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
NORMAL ** |
|
ON |
|
OFF |
|
TEMP. RISE |
|
44 |
|
44 |
|
44 |
|
|
44 |
|
|
- |
|||||
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
|
|
|
|
|
|
|
WATTS |
|
105 |
|
155 |
|
195 |
|
|
240 |
|
|
|
|||
|
|
|
|
|
|
|
|
|
CFM |
|
870 |
|
870 |
|
870 |
|
|
870 |
|
|
|
||
|
HIGH |
|
OFF |
|
OFF |
|
TEMP. RISE |
|
39 |
|
39 |
|
39 |
|
|
39 |
|
|
- |
||||
|
|
|
|
|
|
|
|
WATTS |
|
135 |
|
185 |
|
235 |
|
|
290 |
|
|
|
|||
|
|
|
|
|
|
|
|
|
CFM |
|
860 |
|
920 |
|
920 |
|
|
920 |
|
|
670 |
||
|
LOW |
|
ON |
|
ON |
|
TEMP. RISE |
|
61 |
|
57 |
|
57 |
|
|
57 |
|
|
79 |
||||
|
|
|
|
|
|
|
|
WATTS |
|
140 |
|
200 |
|
245 |
|
|
300 |
|
|
245 |
|||
|
|
|
|
|
|
|
|
|
CFM |
|
1000 |
|
1000 |
|
1000 |
|
|
1000 |
|
700 |
|||
HEATING |
MEDIUM LOW |
|
OFF |
|
ON |
|
TEMP. RISE |
|
53 |
|
53 |
|
53 |
|
|
53 |
|
|
75 |
||||
|
|
|
|
|
|
|
WATTS |
|
190 |
|
255 |
|
305 |
|
|
340 |
|
|
255 |
||||
2ND |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
CFM |
|
1125 |
|
1125 |
|
1125 |
|
|
1025 |
|
775 |
||||
STAGE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
NORMAL ** |
|
ON |
|
OFF |
|
TEMP. RISE |
|
47 |
|
47 |
|
47 |
|
|
51 |
|
|
68 |
|||||
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
|
|
|
|
|
|
|
WATTS |
|
250 |
|
315 |
|
370 |
|
|
355 |
|
|
285 |
|||
|
|
|
|
|
|
|
|
|
CFM |
|
1250 |
|
1250 |
|
1250 |
|
|
1100 |
|
1000 |
|||
|
HIGH |
|
OFF |
|
OFF |
|
TEMP. RISE |
|
42 |
|
42 |
|
42 |
|
|
48 |
|
|
53 |
||||
|
|
|
|
|
|
|
|
WATTS |
|
340 |
|
405 |
|
445 |
|
|
390 |
|
|
355 |
|||
NOTES: * First letter may be "A" or "T" |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
** Factory setting |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*UH2B060A9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER |
|||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
OUTDOOR |
AIRFLOW |
|
|
DIP SWITCH SETTING |
|
|
EXTERNAL STATIC PRESSURE |
||||||||||||||||
UNIT SIZE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
SETTING |
|
SW 1 |
|
SW 2 |
|
SW 3 |
|
SW 4 |
|
|
0.1 |
|
0.3 |
0.5 |
|
|
0.7 |
|
0.9 |
||||
(TONS) |
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LOW |
|
ON |
|
ON |
|
|
OFF |
|
ON |
CFM |
575 |
|
575 |
575 |
|
|
550 |
|
- |
|||
|
(350 CFM/TON) |
|
|
|
|
|
WATTS |
65 |
|
90 |
125 |
|
|
155 |
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
1.5 |
NORMAL |
|
ON |
|
ON |
|
|
OFF |
|
OFF |
CFM |
640 |
|
640 |
640 |
|
|
630 |
|
- |
|||
(400 CFM/TON) |
|
|
|
|
|
WATTS |
70 |
|
110 |
140 |
|
|
175 |
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
HIGH |
|
ON |
|
ON |
|
|
ON |
|
OFF |
CFM |
700 |
|
700 |
700 |
|
|
700 |
|
- |
|||
|
(450 CFM/TON) |
|
|
|
|
|
WATTS |
85 |
|
125 |
160 |
|
|
200 |
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
LOW |
|
OFF |
|
ON |
|
|
OFF |
|
ON |
CFM |
700 |
|
700 |
700 |
|
|
700 |
|
- |
|||
|
(350 CFM/TON) |
|
|
|
|
|
WATTS |
100 |
|
130 |
170 |
|
|
210 |
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
2.0 |
NORMAL |
|
OFF |
|
ON |
|
|
OFF |
|
OFF |
CFM |
800 |
|
800 |
800 |
|
|
800 |
|
- |
|||
(400 CFM/TON) |
|
|
|
|
|
WATTS |
115 |
|
155 |
200 |
|
|
250 |
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
HIGH |
|
OFF |
|
ON |
|
|
ON |
|
OFF |
CFM |
900 |
|
900 |
900 |
|
|
900 |
|
- |
|||
|
(450 CFM/TON) |
|
|
|
|
|
WATTS |
140 |
|
195 |
240 |
|
|
290 |
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
LOW |
|
ON |
|
OFF |
|
|
OFF |
|
ON |
CFM |
875 |
|
875 |
875 |
|
|
875 |
|
- |
|||
|
(350 CFM/TON) |
|
|
|
|
|
WATTS |
130 |
|
180 |
230 |
|
|
270 |
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
2.5 |
NORMAL |
|
ON |
|
OFF |
|
|
OFF |
|
OFF |
CFM |
1000 |
|
1000 |
1000 |
|
1000 |
900 |
|||||
(400 CFM/TON) |
|
|
|
|
|
WATTS |
175 |
|
235 |
285 |
|
|
335 |
|
310 |
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
HIGH |
|
ON |
|
OFF |
|
|
ON |
|
OFF |
CFM |
1125 |
|
1125 |
1125 |
|
1100 |
925 |
|||||
|
(450 CFM/TON) |
|
|
|
|
|
WATTS |
235 |
|
295 |
345 |
|
|
370 |
|
318 |
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
3 |
LOW |
|
OFF |
|
OFF |
|
|
OFF |
|
ON |
CFM |
1050 |
|
1050 |
1050 |
|
1050 |
920 |
|||||
(350 CFM/TON) |
|
|
|
|
|
WATTS |
195 |
|
260 |
305 |
|
|
350 |
|
315 |
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
NORMAL |
|
OFF |
|
OFF |
|
|
OFF |
|
OFF |
CFM |
1200 |
|
1200 |
1200 |
|
1100 |
940 |
|||||
|
(400 CFM/TON) |
|
|
|
|
|
WATTS |
275 |
|
330 |
385 |
|
|
385 |
|
330 |
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
HIGH |
|
OFF |
|
OFF |
|
|
ON |
|
OFF |
CFM |
1325 |
|
1325 |
1300 |
|
1175 |
1000 |
|||||
|
(450 CFM/TON) |
|
|
|
|
|
WATTS |
360 |
|
425 |
460 |
|
|
425 |
|
365 |
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NOTES: * First letter may be "A" or "T"
1.At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2.LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting;
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
9
Pub. No. 22-1814-08