Trane Split System Air Conditioners Odyssey Catalogue

0 (0)
Trane Split System Air Conditioners Odyssey Catalogue

Product Catalog

Split System Air Conditioners Odyssey

R-22 Dry Charge

Heat Pump Condenser — 7.5, 10, 15 and 20 Tons — 60 Hz

May 2014

SSP-PRC027B-EN

Introduction

Trane’s reputation for providing quality comfort solutions continues with the development of the next generation Light Commercial Odyssey Split Systems.

With wide network availability, flexible applications, installation ease, built-in reliability and easy servicing, Odyssey will meet any number of customer applications. Add to that Trane’s outstanding customer service and you have the formula to make Odyssey the clear choice for continued customer satisfaction.

Wide network availability

A broad distribution network provides owners, maintenance personnel, contractors, etc., the means to get their hands on equipment when they need it. Whether it’s an emergency replacement or a new construction project in its infancy stages, Odyssey products meet an array of needs at the right time and right price.

Flexible applications

No matter what the application, Odyssey provides the solution. A broad array of models and tonnages are available with single or dual compressors, single or dual circuits and numerous accessories. Condensing units can be installed on the ground or on a rooftop along with extended piping runs, while air handlers can be free discharge on the ground or horizontally suspended with long duct runs from a ceiling. Should application challenges arise, Odyssey delivers.

Easy to install

Small footprints and low weights combined with factory installed components like TXVs, filter driers, etc., reduce installation time and cost. Colored and numbered wiring and factory tested units make Odyssey the right choice.

Built-in reliability

Keeping in mind that productivity only occurs when equipment is operational,Trane has taken the steps to ensure that Odyssey is up and running. Early indicators such as phase/reversal monitors and loss of charge protection provide diagnostics which prevent failure and provide years of worry-free service and operation.

©2014 Trane All rights reserved

SSP-PRC027B-EN

Innttrroodduuccttiioon

Easy to service

When preventive maintenance or service is required, technicians will find efficient access to both air handlers and condensers. Panels provide complete, easy access coupled with standardized cabinets in which all components are located in proximity. Odyssey’s improved design results in minimum service times and costs.

With these capabilities, Odyssey provides customers high efficiency and superior performance for the best all-around value in the market today.

Copyright

This document and the information in it are the property of Trane, and may not be used or reproduced in whole or in part without written permission. Trane reserves the right to revise this publication at any time, and to make changes to its content without obligation to notify any person of such revision or change.

Trademarks

All trademarks referenced in this document are the trademarks of their respective owners.

SSP-PRC027B-EN

3

Table of Contents

Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Heat Pump Condenser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

Model Number Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Heat Pump Condenser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

General Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Dimensional Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Heat Pump Condenser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Weights. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Heat Pump Condenser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

4

SSP-PRC027B-EN

Accessories

Heat Pump Condenser

Table 1. TWA Accessories

Model

Used With

Coil (Hail/Vandal) Guard

 

BAYGARD058A

TWA090A

BAYGARD060A

TWA120A

BAYGARD061A

TWA180B, TWA240B

BAYHGBP010B

All models

Rubber Isolators

 

BAYISLT005A (black)

BAYISLT009A (red)

BAYISLT010A (green)

Steel Spring Isolators

BAYISLT023A (red)

BAYISLT024A (black)

BAYISLT025A (yellow)

Low Ambient — On/Off Fan Control (External mount, small cabinets)(a) (b) (c)

BAYLOAMU01B (External Mount, small cabinets)(d)

BAYLOAMU02B (Internal mount, large cabinets)

TWA090A, TWA120A

TWA180B

TWA240B

TWA090A, TWA120A

TWA180B

TWA240B

(all voltages) TWA090A

(all voltages) TWA120A, TWA180B, TWA240B

(a)Cycles fan on/off, (no modulating).

(b)Quantity of 1 required for each fan (2 total for ).

(c)ReliaTel™ requires onboard EDC function to be disabled when BAYLOAM is used, remove OA sensor from terminal J8-1&2

(d)Kit mounts external to the outdoor unit and operates by sensing ambient and liquid line temperatures.

SSP-PRC027B-EN

5

Model Number Description

Heat Pump Condenser

T W A

120

A

3

0 0

*

*

1 2 3

4 5 6

7

8

9 10

11

12

All products are identified by a multiple-character model number that precisely identifies a particular type of unit. An explanation of the alphanumeric identification code is provided. Its use will enable the owner/operator, installing contractors, and service engineers to define the operation, specific components, and other options for any specific unit. When ordering replacement parts or requesting service, be sure to refer to the specific model number, serial number, and DL number (if applicable) stamped on the unit nameplate.

DIIGGIITTS 1 - 3: Prroodduucct Tyyppe

TWA = Split System Heat Pump

DIIGGIITTS 4 - 6: Noommiinnaal Grroosss Coooolliinng Caappaacciitty (MMBBhh)

090 = 7.5 Tons (60Hz)

120 = 10 Tons (60Hz)

180 = 15 Tons (60Hz)

240 = 20 Tons (60Hz)

DIIGGIIT 7: Maajjoor Deevveellooppmmeennt Seeqquueenncce

A = Single Compressor, Single Circuit, R-22

B = Dual Compressor, Dual Circuit, R-22

DIIGGIIT 8: Elleeccttrriiccaal Chhaarraacctteerriissttiiccs

3 = 208–230/60/3

4 = 460/60/3

DIIGGIITTS 9 - 100: Faaccttoorry Innssttaalllleed Oppttiioonns

00 = Packed Stock

DIIGGIITTS 111: Miinnoor Deessiiggn Seeqquueenncce

* = Current Design Sequence1

DIIGGIITTS 122: Seerrvviicce Diiggiit

* = Current Design Sequence1

1. * = sequential alpha character