Trane CFEB 04 C0M1, CFEB 06 C0M1, CFEB 08 C0M1, CFEB 10 C0M1, CFEB 12 C0M1 Owner's Manual

...
0 (0)
Owner Manual
AQUA NEW STYLUS
Chilled Water Fan Coil
Convertible Type
CFEB Series 50/60 Hz
50 Hz Models Cooling Only
CFEB 04 C0M1 CFEB 06 C0M1 CFEB 08 C0M1 CFEB 10 C0M1 CFEB 12 C0M1 CFEB 14 C0M1 CFEB 16 C0M1 CFEB 20 C0M1
60 Hz Models Cooling Only
CFEB 04 C0M2 CFEB 06 C0M2 CFEB 08 C0M2 CFEB 10 C0M2 CFEB 12 C0M2 CFEB 14 C0M2 CFEB 16 C0M2 CFEB 20 C0M2
June 2017
UNT-SVU002-EN
General Information
General Information
Congratulations on your choice of a Trane chilled water fancoil system. These systems have been carefully designed and manufactured under strict Trane Worldwide Quality Standards to provide you with years of comfortable, convenient cooling or heating/cooling with a minimum of service. This Owner Manual is given as a guide to start-up, operation and periodic maintenance by the user of CFEB chilled water fancoil system. It does not contain the full service procedures necessary for the continued successful operation of this equipment. The services of a
qualied service technician should be
employed, through the maintenance contract with a reputable service company. Read it completely before doing anything with your air conditioning system.
About this Manual
Cautions appear at appropriate places in this instruction manual. Your personal safety and the proper operation of this machine require that you follow them carefully. The Trane Company assumes no liability for the inappropriate usage of the unit.
About the Unit
These CFEB units are assembled, pressure tested, dehydrated, charged and run tested before shipment. The information contained in this manual
applies to CFEB units are designed to operate in cooling mode only and in cooling or heating modes. Trane CFEB series of chilled water
fancoil systems o󰀨er three styles of installation: oor, low wall and under
ceiling with both LCD wireless remote control or wired control.
Trane CFEB series provide exibility
and savings. Note: For model CFEB14, CFEB16 and CFEB20, there are only two styles of installation: under ceiling and low wall.
Reception
On arrival, inspect the unit before signing the delivery note. Specify any damage of the unit on the delivery note, and send a registered letter of protest to the last carrier of the goods within 72 hours of delivery. Notify the dealer at the same time. The unit should be totally inspected within 7 days of delivery. If any concealed damage is discovered, send a registered letter of protest to the carrier within 7 days of delivery and notify the dealer.
Warning
Warnings are provided at appropriate places in this manual to indicate to installers, operators and service personnel of potentially hazardous situations which, if not avoided, COULD result in death or serious injury.
Caution
Cautions are provided at appropriate places in this manual to indicate to
installers, operators, and service personnel of potentially hazardous situations which, if not avoided, MAY result in minor or moderate injury or malfunction of the unit. Your personal safety and the proper operation of this unit require that you follow them carefully. The Trane Company assumes no liability for installations or servicing performed
by unqualied personnel.
Warranty
Warranty is based on the general terms and conditions by country. The warranty is void if the equipment
is modied or repaired without
the written approval of The Trane Company, if the operating limits are
exceeded or if the control system or the electrical wiring is modied.
Damage due to misusage, lack of maintenance or failure to comply with the manufacturer’s instructions, is not covered by the warranty obligation. If the user does not conform to the rules described in Owner Manual, it may entail cancellation of warranty and liabilities by The Trane Company.
Important
These instructions do not cover all variations in systems, nor do they provide for every possible contingency to be met. Should further information be desired or should particular problems arise
which are not covered su󰀩ciently for
the purchaser’s purposes, the matter should be referred to your authorized Trane dealer.
UNT-SVU002-EN
2
Contents
General Information ........................................................................2
Control Operation ............................................................................ 4
Wireless Remote Control ................................................................5
Digital Wired Control .......................................................................9
System Operation .......................................................................... 12
Electronic Room Thermostat .......................................................13
Maintenance ................................................................................... 14
Troubleshooting ............................................................................15
3
UNT-SVU002-EN
Control Operation
Infrared Remote Control Unit Display and One-touch Control Switch
Display Panel
Four lamps on the unit show operating status.
1. FAN Lamp
This lamp lights when the fan is operating.
2. COOLING Lamp
This lamp lights when the unit is in COOL or DRY mode of operation.
3. TIMER Lamp
This lamp lights when the system is being controlled by the timer.
4. Compressor Lamp
This lamp lights when compressor is operated.
One Touch Control Switch (A)
This button is used for adjusting operation without remote control unit.
UNT-SVU002-EN
4
Wireless Remote Control
Infrared Remote Control
Name and function of buttons
1. Infrared Signal Transmitter
Transmits the signal to indoor unit.
2. POWER Button
Press this button to start unit operation. Press this button again to stop unit operation.
3. Temperature Setting Button
TEMP : Press this button to increase the set temperature. TEMP : Press this button to decrease the set temperature.
4. FAN SPEED Button
Press this button to select fan speed.
5. MODE Button
Press this button to select system operation mode. In cooling only system, a mode is selected in sequence as FAN, COOL, DRY, and back to FAN.
6. LOUVER Button
Press this button to adjust blade direction.
7. SWEEP Button
Press this button to activate or inactivate sweep motor to
distribute air ow.
8. FRONT BLADE Button
Press this button to activate or inactivate front blade function.
9. ON TIMER Button
Press this button to set the on timer of the unit operation.
10. OFF TIMER Button
Press this button to set the o󰀨
timer of the unit operation.
11. CLOCK Button
Press this button to set the clock to the present time or see the present time after ON or OFF TIMER was set.
12. LIGHT Button
Press this button to turn on the LCD light.
13. POWERCOOL Button
Press this button to accelerate capacity up.
14. ECONO Button
Press this button to save energy.
15. SLEEP Button
Press this button to control temperature while sleeping and press this button again to cancel.
16. SEND Button
Press this button to conrm the
operation of the unit according to the LCD display or press and hold for 5 seconds to toggle temperature unit between Celsius and Fahrenheit.
Installation of Batteries
1. Slide the back cover of the remote
control down to take it o󰀨.
2. Insert two dry batteries into the
slot. Be sure that the + and – directions are correct.
3. Fix the back cover to the remote
control as before.
Attentions
• Batteries can be used
approximately for one year under
normal conditions.
• Always replace an identical type of two batteries at the same time.
• Do not use manganese dry batteries since they may cause a malfunction.
• Do not use rechargeable (Ni-Cd) batteries, because such batteries
may di󰀨er from standard dry cell
batteries in shapes, dimensions, or performance.
• Take out all batteries if you are not going to use the air-conditioner for a long period of time.
5
UNT-SVU002-EN
Loading...
+ 11 hidden pages