Product Data
Split System Cooling
4TTR3018H1000N
4TTR3024H1000N
4TTR3030H1000N
4TTR3036H1000N
4TTR3042E1000N
4TTR3048E1000N
4TTR3060D1000N
August 2016 |
22-1842-8D-EN |
Model No. (a) |
4TTR3018H1000N |
4TTR3024H1000N |
4TTR3030H1000N |
4TTR3036H1000N |
|
POWER CONNS. — V/PH/HZ (b) |
208/230/1/60 |
208/230/1/60 |
208/230/1/60 |
208/230/1/60 |
|
MIN. BRCH. CIR. AMPACITY |
12 |
17 |
16 |
18 |
|
BR. CIR. PROT. RTG. — MAX. |
20 |
25 |
25 |
30 |
|
(AMPS) |
|||||
|
|
|
|
||
COMPRESSOR |
CLIMATUFF®- |
CLIMATUFF®- |
CLIMATUFF®- |
CLIMATAUFF®- |
|
SCROLL |
SCROLL |
SCROLL |
SCROLL |
||
|
|||||
RL AMPS — LR AMPS |
9 — 48 |
12.8 — 58.3 |
12.3 — 63 |
14.1— 75 |
|
Outdoor Fan FL AMPS |
0.64 |
0.64 |
0.9 |
0.7 |
|
Fan HP |
1/8 |
1/8 |
1/8 |
1/8 |
|
Fan Dia (inches) |
23.0 |
23.0 |
18.9 |
23.0 |
|
Coil |
SPINE FIN™ |
SPINE FIN™ |
SPINE FIN™ |
SPINE FIN™ |
|
Refrigerant R-410A |
5 LBS., 11 OZ |
5 LBS., 9 OZ |
4 LBS., 10 OZ |
4 LBS., 13 OZ |
|
LINE SIZE — IN. O.D. GAS (c) |
3/4 |
3/4 |
3/4 |
3/4 |
|
LINE SIZE — IN. O.D. LIQ. (c) |
3/8 |
3/8 |
3/8 |
3/8 |
|
Charge Spec. Subcooling |
10°F |
10°F |
10°F |
10°F |
|
Dimensions H x W X D Crated |
34 x 30.1 x 33 |
34 x 30.1 x 33 |
30 x 27 x 30 |
34 x 30.1 x 33 |
|
(IN.) |
|||||
|
|
|
|
||
Weight — Shipping (lbs.) |
167 |
169 |
157 |
175 |
|
Weight — Net (lbs.) |
140 |
142 |
137 |
147 |
|
Optional Accessories: |
|
|
|
|
|
Anti-short CycleTimer |
TAYASCT501A |
TAYASCT501A |
TAYASCT501A |
TAYASCT501A |
|
Evaporator Defrost Control |
AY28X079 |
AY28X079 |
AY28X079 |
AY28X079 |
|
Rubber Isolator Kit |
BAYISLT101 |
BAYISLT101 |
BAYISLT101 |
BAYISLT101 |
|
Extreme Condition Mount Kit |
BAYECMT023 |
BAYECMT023 |
BAYECMT023 |
BAYECMT023 |
|
Start Kit |
BAYKSKT263 |
BAYKSKT263 |
BAYKSKT263 |
BAYKSKT263 |
|
Crankcase Heater Kit |
BAYCCHT302 |
BAYCCHT302 |
BAYCCHT302 |
BAYCCHT302 |
|
Seacoast Kit |
BAYSEAC001 |
BAYSEAC001 |
BAYSEAC001 |
BAYSEAC001 |
|
Low Ambient Kit |
BAYLOAM103 |
BAYLOAM103 |
BAYLOAM103 |
BAYLOAM103 |
|
Refrigerant Lineset (d) |
TAYREFLN950 |
TAYREFLN950 |
TAYREFLN7* |
TAYREFLN7* |
(a)Certified in accordance with the Unitary Air-conditioner equipment certification program which is based on AHRI standard 210/240.
(b)Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses.
(c)Standard line lengths — 60’, Standard lift — 60’ Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub#32–3312–0* (* denotes latest revision)..
(d)* = 15, 20, 25, 30, 40 and 50 foot lineset available.
2 |
22-1842-8D-EN |
Product Specifications
Model No. (a) |
4TTR3042E1000N |
4TTR3048E1000N |
4TTR3060D1000N |
POWER CONNS. — V/PH/HZ (b) |
280/230/1/60 |
280/230/1/60 |
280/230/1/60 |
MIN. BRCH. CIR. AMPACITY |
22 |
28 |
35 |
BR. CIR. PROT. RTG. — MAX. (AMPS) |
35 |
45 |
60 |
COMPRESSOR |
CLIMATUFF®- SCROLL CLIMATUFF®- SCROLL CLIMATUFF®- SCROLL |
||
RL AMPS — LR AMPS |
17.0 — 124 |
21.8 — 117 |
26.8 — 134 |
Outdoor Fan FL AMPS |
0.7 |
0.93 |
0.93 |
Fan HP |
1/8 |
1/5 |
1/5 |
Fan Dia (inches) |
23 |
23 |
27.5 |
Coil |
SPINE FIN™ |
SPINE FIN™ |
SPINE FIN™ |
Refrigerant R-410A |
5 LBS., 8 OZ |
6 LBS., 7 OZ |
8 LBS., 0 OZ |
LINE SIZE — IN. O.D. GAS (c) |
7/8 |
7/8 |
7/8 |
LINE SIZE — IN. O.D. LIQ. (c) |
3/8 |
3/8 |
3/8 |
Charge Spec. Subcooling |
10°F |
10°F |
10°F |
Dimensions H x W X D Crated (IN.) |
34 x 30.1 x 33 |
42 x 30.1 x 33 |
42.4 x 35.1 x 38.7 |
Weight — Shipping (lbs.) |
200 |
233 |
261 |
Weight — Net (lbs.) |
172 |
197 |
226 |
Optional Accessories: |
|
|
|
Anti-short CycleTimer |
TAYASCT501A |
TAYASCT501A |
TAYASCT501A |
Evaporator Defrost Control |
AY28X079 |
AY28X079 |
AY28X079 |
Rubber Isolator Kit |
BAYISLT101 |
BAYISLT101 |
BAYISLT101 |
Extreme Condition Mount Kit |
BAYECMT004 |
BAYECMT004 |
BAYECMT004 |
Start Kit |
BAYKSKT263 |
BAYKSKT263 |
BAYKSKT263 |
Crankcase Heater Kit |
BAYCCHT301 |
BAYCCHT301 |
BAYCCHT301 |
Seacoast Kit |
BAYSEAC001 |
BAYSEAC001 |
BAYSEAC001 |
Low Ambient Kit |
BAYLOAM103 |
BAYLOAM103 |
BAYLOAM103 |
Refrigerant Lineset (d) |
TAYREFLN7* |
TAYREFLN3* |
TAYREFLN3* |
(a)Certified in accordance with the Unitary Air-conditioner equipment certification program which is based on AHRI standard 210/240.
(b)Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses.
(c)Standard line lengths — 60’, Standard lift — 60’ Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub#32–3312–0* (* denotes latest revision)..
(d)* = 15, 20, 25, 30, 40 and 50 foot lineset available.
|
|
|
Sound Power Level |
|
|
|
|
||
|
A-Weighted |
|
|
|
|
|
|
|
|
MODEL |
Sound Power |
|
|
Full Octave Sound Power(dB) |
|
|
|||
|
Level [dB(A)] |
|
|
|
|
|
|
|
|
|
|
63 |
125 |
250 |
500 |
1000 |
2000 |
4000 |
8000 |
|
|
Hz* |
Hz |
Hz |
Hz |
Hz |
Hz |
Hz |
Hz |
4TTR3018H1 |
72 |
73.7 |
71.4 |
65.4 |
68 |
67.3 |
62.9 |
56 |
50.3 |
4TTR3024H1 |
74 |
47.9 |
60.5 |
64.1 |
71.2 |
71.2 |
69.0 |
58.2 |
51.5 |
4TTR3030H1 |
72 |
69.9 |
69.6 |
69.1 |
68.6 |
68.7 |
60.9 |
56.2 |
48.9 |
4TTR3036H1 |
68 |
74.7 |
65.0 |
65.2 |
66.4 |
63.6 |
58.7 |
56.3 |
52.8 |
4TTR3042E1 |
72 |
77.6 |
68.3 |
67.4 |
65.6 |
67.4 |
58.2 |
54.1 |
47.6 |
4TTR3048E1 |
74 |
72.5 |
72.3 |
69.2 |
67.5 |
72.3 |
60.2 |
55.2 |
54.2 |
4TTR3060D1 |
80 |
47.3 |
55.7 |
69 |
72.7 |
75.8 |
69.4 |
62.2 |
53.3 |
Note: Rated in accordance with |
*For Reference Only |
|
|
|
|
|
|||
AHRI Standard 270–2008 |
|
|
|
|
|
|
|
|
22-1842-8D-EN |
3 |