Panasonic KX-TEB308 Service Manual

4.6 (5)
Panasonic KX-TEB308 Service Manual

Advanced Hybrid System

Installation Manual

Model No. KX-TEB308

Thank you for purchasing a Panasonic Advanced Hybrid System.

Please read this manual carefully before using this product and save this manual for future use.

System Components

System Components Table

 

Model

Description

 

 

 

Main Unit

KX-TEB308

Advanced Hybrid System: 3 Outside (CO) Lines, 4 Hybrid

 

 

and 4 SLT Extensions*1

Optional Service Cards

KX-TE82460

2-Port Doorphone Card

 

KX-TE82493

3-Port Caller ID Card

 

 

 

Proprietary Equipment

KX-T30865

Doorphone

 

KX-A227

Backup Battery Cable

 

 

 

*1 Taiwan: 4 PT Extensions

For supported extension types, refer to "2.5.1 Connecting Extensions".

Abbreviations in this manual

Proprietary Telephone: PT

Single Line Telephone: SLT

Direct Station Selection: DSS

Compatible Proprietary Telephones

KX-T7700, KX-T7300, and KX-T7000 series PTs

KX-T7710 SLT

KX-T7740, KX-T7340, and KX-T7040 DSS Consoles

For the equipment that can be connected to the PBX, refer to "1.2.2 System Connection Diagram".

Notice

Certain models may not be available in your country/area.

Certain PTs and features may not be available in your country/area. Consult your certified Panasonic dealer for more information.

2 Installation Manual

Important Safety Instructions

When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following:

1.Read and understand all instructions.

2.Follow all warnings and instructions marked on the product.

3.Unplug the product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Clean with a damp cloth.

4.Do not use this product near water, for example, near a bathtub, wash bowl, kitchen sink, or laundry tub, in a wet basement, or near a swimming pool.

5.Do not place the product on an unstable surface, as a fall may cause serious internal damage.

6.Slots and openings in the front, back and bottom of the cabinet are provided for ventilation; to protect it from overheating, these openings must not be blocked or covered. The openings should never be blocked by placing the product on a bed, sofa, rug, or other similar surface while in use. The product should never be placed near or over a radiator or other heat source. This product should not be placed in a sealed environment unless proper ventilation is provided.

7.The product should only be connected to the type of electrical power supply specified on the product label. If you are not sure of the type of power supply to your home, consult your dealer or local power company.

8.For safety purposes this unit is equipped with an earthed plug. If you do not have an earthed outlet, please have one installed. Do not bypass this safety feature by tampering with the plug.

9.Do not allow anything to rest on the power cord. Do not locate this product where the power cord may be stepped on or tripped on.

10.To reduce the risk of fire or electric shock, do not overload wall outlets and extension cords.

11.Do not insert objects of any kind into this product through its slots and openings, as they may touch dangerous voltage points or short out parts that could result in a risk of fire or electric shock. Never spill liquid of any kind on or in the product.

12.To reduce the risk of electric shock, do not disassemble this product. Only qualified personnel should service this product. Opening or removing covers may expose you to dangerous voltages or other risks. Incorrect reassembly can cause electric shock.

13.Unplug this product from the wall outlet and have it serviced by qualified service personnel in the following cases:

a)When the power supply cord or plug is damaged or frayed.

b)If liquid has been spilled into the product.

c)If the product has been exposed to rain or water.

d)If the product does not operate according to the operating instructions. Adjust only the controls that are explained in the operating instructions. Improper adjustment of other controls may result in damage and may require service by a qualified technician to restore the product to normal operation.

e)If the product has been dropped or the cabinet has been damaged.

f)If product performance deteriorates.

14.Avoid using wired telephones during an electrical storm. There is a remote risk of electric shock from lightning.

15.Do not use a telephone in the vicinity of a gas leak to report the leak.

SAVE THESE INSTRUCTIONS

Installation Manual

3

 

 

Precautions

Keep the unit away from heating appliances and devices that generate electrical noise such as fluorescent lamps, motors and televisions. These noise sources can interfere with the performance of the PBX.

This unit should be kept free of dust, moisture, high temperature (more than 40 ˚C ) and vibration, and should not be exposed to direct sunlight.

If you are having problems making calls to outside destinations, follow this procedure to test the outside (CO) lines:

1.Disconnect the PBX from all outside (CO) lines.

2.Connect known working single line telephones (SLTs) to those outside (CO) lines.

3.Make a call to an external destination using those SLTs.

If a call cannot be carried out correctly, there may be a problem with the outside (CO) line that the SLT is connected to. Contact your telephone company.

If all SLTs operate properly, there may be a problem with your PBX. Do not reconnect the PBX to the outside (CO) lines until it has been serviced by an authorised Panasonic Factory Service Centre.

Wipe the unit with a soft cloth. Do not clean the unit with abrasive powders or with chemical agents such as benzene or thinner.

For users in New Zealand only

This equipment shall not be set to make automatic calls to the Telecom '111' Emergency Service.

The grant of a Telepermit for any item of terminal equipment indicates only that Telecom has accepted that the item complies with minimum conditions for connection to its network. It indicates no endorsement of the product by Telecom, nor does it provide any sort of warranty. Above all, it provides no assurance that any item will work correctly in all respects with another item of Telepermitted equipment of a different make or model, nor does it imply that any product is compatible with all of Telecom's network services.

This equipment is not capable, under all operating conditions, of correct operation at the higher speeds for which it is designed. Telecom will accept no responsibility should difficulties arise in such circumstances.

Some parameters required for compliance with Telecom's Telepermit requirements are dependent on the equipment (PBX) associated with this modem. In order to operate within the limits for compliance with Telecom's Specifications, the associated PBX equipment shall be set to ensure that modem calls are answered between 3 and 30 seconds of receipt of ringing.

IMPORTANT NOTICE

Under power failure conditions, the connected telephones may not operate. Please ensure that a separate telephone, not dependent on local power, is available for emergency use.

For users in Taiwan only

Lithium batteries can be found in the circuit boards of the main board and optional cards of the PBX.

Notes

When disposing of any of the above products, all batteries must be removed. Follow the applicable laws, regulations, and guidelines in your country/area regarding disposal of batteries.

When replacing a battery, use only the same battery type, or an equivalent recommended by the battery manufacturer.

4 Installation Manual

Notice

Regarding removing or replacing a battery in the circuit board, consult your dealer.

For users in Finland, Norway and Sweden only

This unit may only be installed in a room or space with restricted access, and equipotential bonding must be applied. For information on earthing, refer to "2.2.5 Connecting Frame Earth".

WARNING

THIS UNIT MAY ONLY BE INSTALLED AND SERVICED BY QUALIFIED SERVICE PERSONNEL.

IF DAMAGE TO THE UNIT EXPOSES ANY INTERNAL PARTS, DISCONNECT THE POWER SUPPLY CORD IMMEDIATELY AND RETURN THE UNIT TO YOUR DEALER.

UNPLUG THIS UNIT FROM THE AC OUTLET IF IT EMITS SMOKE, AN ABNORMAL SMELL OR MAKES UNUSUAL NOISE. THESE CONDITIONS CAN CAUSE FIRE OR ELECTRIC SHOCK. CONFIRM THAT SMOKE HAS STOPPED AND CONTACT AN AUTHORISED PANASONIC FACTORY SERVICE CENTRE.

WHEN RELOCATING THE EQUIPMENT, FIRST DISCONNECT THE TELECOM CONNECTION BEFORE DISCONNECTING THE POWER CONNECTION. WHEN THE UNIT IS INSTALLED IN THE NEW LOCATION, RECONNECT THE POWER FIRST, AND THEN RECONNECT THE TELECOM CONNECTION.

TO PREVENT POSSIBLE FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE.

THE POWER SUPPLY CORD IS USED AS THE MAIN DISCONNECT DEVICE. ENSURE THAT THE AC OUTLET IS LOCATED NEAR THE EQUIPMENT AND IS EASILY ACCESSIBLE.

CAUTION

DANGER OF EXPLOSION EXISTS IF A BATTERY IS INCORRECTLY REPLACED. REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE RECOMMENDED BY THE BATTERY MANUFACTURER. DISPOSE OF USED BATTERIES ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS.

For Future Reference

Please print, record, and retain the following information for future reference.

Note

The serial number of this product can be found on the label affixed to the unit. You should record the model number and the serial number of this unit as a permanent record of your purchase to aid in identification in the event of theft.

Installation Manual

5

 

 

MODEL NO.

SERIAL NO.

DATE OF PURCHASE

NAME OF DEALER

DEALER'S ADDRESS

DEALER'S TEL. NO.

6 Installation Manual

Introduction

About the Installation Manual

This Installation Manual is designed to serve as an overall technical reference for Panasonic Advanced Hybrid System, KX-TEB308. It explains how to install the hardware and programme this PBX using KX-TEB308 Maintenance Console.

The Installation Manual is divided into the following sections:

Section 1 System Outline

Provides general information on the PBX, including the system capacity and specifications.

Section 2 Installation

Provides detailed instructions for installing the PBX, optional service cards, and peripheral equipment.

Section 3 Guide for KX-TEB308 Maintenance Console

Explains how to install and use KX-TEB308 Maintenance Console, a PC-based programming utility.

Section 4 Troubleshooting

Provides information on troubleshooting and restarting the PBX.

About the Other Manuals

The following manuals are also available:

Feature Guide

Explains what the PBX can do, as well as how to obtain the most of its many features and facilities.

User Manual

Describes how users can access commonly used features and functions with proprietary telephones (PTs), single line telephones (SLTs), and Direct Station Selection (DSS) Consoles.

Trademarks

Microsoft and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.

Celeron and Intel are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.

All other trademarks identified herein are the property of their respective owners.

Screen shots reprinted with permission from Microsoft Corporation.

Installation Manual

7

 

 

Precautions for Users in the United Kingdom

FOR YOUR SAFETY, PLEASE READ THE FOLLOWING TEXT CAREFULLY.

This appliance is supplied with a moulded three-pin mains plug for your safety and convenience. A 5 amp fuse is fitted in this plug. Should the fuse need to be replaced, please ensure that the replacement fuse has a rating of 5 amps and that it is approved by ASTA or BSI to BS1362.

Check for the ASTA mark or the BSI mark on the body of the fuse.

If the plug contains a removable fuse cover, you must ensure that it is refitted when the fuse is replaced. If you lose the fuse cover, the plug must not be used until a replacement cover is obtained. A replacement fuse cover can be purchased from your local Panasonic dealer.

IF THE FITTED MOULDED PLUG IS UNSUITABLE FOR THE AC OUTLET IN YOUR PREMISES, THEN THE FUSE SHOULD BE REMOVED AND THE PLUG CUT OFF AND DISPOSED OF SAFELY. THERE IS A DANGER OF SEVERE ELECTRICAL SHOCK IF THE CUT-OFF PLUG IS INSERTED INTO ANY 13 AMP OUTLET.

If a new plug is to be fitted, please observe the wiring code as shown below. If in any doubt, please consult a qualified electrician.

WARNING

THIS APPLIANCE MUST BE EARTHED.

IMPORTANT: The wires in the mains lead are coloured as follows:

Green-and-yellow: Earth

Blue: Neutral

Brown: Live

As the colours of the wires in the mains lead of this apparatus may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows.

The wire that is coloured GREEN-AND-YELLOW must be connected to the terminal in the plug that

is marked with the letter E or by the safety earth symbol or coloured GREEN or GREEN-AND- YELLOW.

The wire that is coloured BLUE must be connected to the terminal that is marked with the letter N or coloured BLACK.

The wire that is coloured BROWN must be connected to the terminal that is marked with the letter L or coloured RED.

8 Installation Manual

How to replace the fuse: Open the fuse compartment with a screwdriver and replace the fuse and fuse cover.

The equipment must be connected to direct extension lines, and a payphone should not be connected as an extension.

999 and 112 can be dialled on the apparatus after accessing the Exchange line for the purpose of making outgoing calls to the BT emergency services.

During dialling, this apparatus may tinkle the bells of other telephones using the same line. This is not a fault and we advise you not to call Fault Repair Service.

Installation Manual

9

 

 

Table of Contents

1 System Outline .....................................................................................

13

1.1

System Highlights...........................................................................................................

14

1.1.1

System Highlights .............................................................................................................

14

1.2

Basic System Construction ...........................................................................................

15

1.2.1

Main Unit ...........................................................................................................................

15

1.2.2

System Connection Diagram ............................................................................................

16

1.3

Specifications..................................................................................................................

17

1.3.1

General Description ..........................................................................................................

17

1.3.2

Characteristics ..................................................................................................................

18

1.3.3

System Capacity ...............................................................................................................

19

2 Installation.............................................................................................

21

2.1

Before Installing ..............................................................................................................

22

2.1.1

Before Installing ................................................................................................................

22

2.2

Installing the Advanced Hybrid System........................................................................

24

2.2.1

Unpacking .........................................................................................................................

24

2.2.2

Names and Locations .......................................................................................................

25

2.2.3

Opening/Closing Covers ...................................................................................................

26

2.2.4

Securing the Cables..........................................................................................................

29

2.2.5

Connecting Frame Earth ...................................................................................................

31

2.2.6

Connecting Backup Batteries............................................................................................

32

2.2.7

Wall Mounting ...................................................................................................................

34

2.2.8

Installing Surge Protector..................................................................................................

37

2.3

Installing Optional Service Cards..................................................................................

40

2.3.1

Location of Optional Service Cards ..................................................................................

40

2.3.2

3-Port Caller ID Card (KX-TE82493).................................................................................

41

2.3.3

2-Port Doorphone Card (KX-TE82460).............................................................................

43

2.4

Connecting Outside (CO) Lines.....................................................................................

44

2.4.1

Connecting Outside (CO) Lines ........................................................................................

44

2.5

Connecting Extensions ..................................................................................................

45

2.5.1

Connecting Extensions .....................................................................................................

45

2.5.2

Connecting Extensions in Parallel.....................................................................................

47

2.6

Connecting Doorphones and Door Openers................................................................

48

2.6.1

Connecting Doorphones and Door Openers.....................................................................

48

2.7

Connecting Doorbell or Door Chime.............................................................................

52

2.7.1

Connecting Doorbell or Door Chime .................................................................................

52

2.8

Connecting Peripherals..................................................................................................

53

2.8.1

Connecting Peripherals.....................................................................................................

53

2.9

Power Failure Connections ............................................................................................

57

2.9.1

Power Failure Connections ...............................................................................................

57

2.10

Starting the Advanced Hybrid System..........................................................................

58

2.10.1

Starting the Advanced Hybrid System ..............................................................................

58

3 Guide for KX-TEB308 Maintenance Console .....................................

61

3.1

Installing KX-TEB308 Maintenance Console ................................................................

62

3.1.1

Installing KX-TEB308 Maintenance Console on a PC ......................................................

62

3.2

Connection ......................................................................................................................

64

3.2.1

Connection ........................................................................................................................

64

10 Installation Manual

3.2.2

Starting KX-TEB308 Maintenance Console for the first time

........................................... 67

3.2.3

Accessing PBX via Internal Modem .................................................................................

68

4 Troubleshooting ....................................................................................

71

4.1

Troubleshooting .............................................................................................................

72

4.1.1

Installation ........................................................................................................................

72

4.1.2

Connection .......................................................................................................................

73

4.1.3

Operation..........................................................................................................................

74

4.1.4

System Restart.................................................................................................................

75

4.1.5

System Reset with System Data Clear ............................................................................

76

Index

............................................................................................................

77

Installation Manual

11

 

 

12 Installation Manual

Section 1

System Outline

This section provides general information on the Advanced Hybrid System, including system capacity and specifications.

Installation Manual

13

 

 

1.1 System Highlights

1.1System Highlights

1.1.1System Highlights

Fixed Line SMS Terminal Support (Optional Caller ID card required)

The PBX can relay incoming calls from a Short Message Service (SMS) centre to specific single line telephones (SLTs) that support SMS. Fixed Line SMS is a service that allows text messages to be sent and received via Public Switched Telephone Network (PSTN) access. We recommend using SMS-enabled Panasonic SLTs.

Caller ID Display on SLT (Optional Caller ID card required)

The PBX can receive Caller ID information (telephone numbers and callers' names) from calls received on outside (CO) lines. This information can be shown on the displays of SLTs that support Caller ID as well as proprietary telephones (PTs) when receiving calls.

3-level Automated Attendant (AA)

3-level Automated Attendant (AA) service allows a caller to dial a single-digit number (Direct Inward System Access [DISA] AA number) following the guidance of 3-level DISA outgoing messages (OGMs), and be connected to the desired party automatically.

PC Programming

System programming settings can be accessed using a PC and the Panasonic KX-TEB308 Maintenance Console software as well as by using a PT.

The PBX software can be upgraded via the Serial Interface (RS-232C port) or USB port, using the KX-TEB308 Maintenance Console software.

Quick Setup

Basic PBX parameters such as Automatic Configuration for Outside (CO) Line Type, Country Setting can be programmed the first time the PBX is accessed with a PC using the KX-TEB308 Maintenance Console software.

Advanced Hybrid System

This PBX supports the connection of PTs, Direct Station Selection (DSS) Consoles and single line devices such as SLTs, fax machines, wireless telephones and data terminals.

14 Installation Manual

1.2 Basic System Construction

1.2Basic System Construction

1.2.1Main Unit

The KX-TEB308 has a capacity of 3 outside (CO) lines and 8 extensions. It is capable of supporting Panasonic proprietary telephones (PTs), and single line devices such as single line telephones (SLTs), fax machines and data terminals.

To expand its capabilities, the PBX can be equipped with optional components or user-supplied peripherals, such as door openers, external speakers, and an external audio source such as a radio or CD player.

Note

For supported extension types, refer to "2.5.1 Connecting Extensions".

Installation Manual

15

 

 

1.2 Basic System Construction

1.2.2System Connection Diagram

Outside (CO) Line

Remote PC

Batteries

Door Opener/

Doorbell/Door Chime

Doorphone

PC

Printer PC

External audio source (radio, CD player, etc.)

Paging system

(loudspeaker, amplifier

and speaker, etc.)

SLT

PT

Fax/Telephone

Answering Machine

DSS Console

Wireless Phone

Voice Processing

System

Connect a display-equipped proprietary telephone (PT) to extension jack 01, as this extension is automatically designated as the manager extension.

A PT and a single line telephone (SLT) can be connected in parallel to a Hybrid Port. (→2.5.2 Connecting Extensions in Parallel)

For supported extension types, refer to "2.5.1 Connecting Extensions".

16 Installation Manual

1.3 Specifications

1.3Specifications

1.3.1General Description

Control Bus

 

Original bus (16-bit, 24 MHz)

 

 

 

 

Switching

 

Space Division CMOS Crosspoint Switch

 

 

 

Power Input

 

100 V AC to 240 V AC, 0.8A to 0.4A, 50 Hz/60 Hz

 

 

 

 

External Battery

 

+24 V DC (+12 V DC × 2)

 

 

 

Maximum Power Failure Tolerance

300 ms (without using backup batteries)

 

 

 

Memory Backup Duration

7 years

 

 

 

 

 

Dialling

Outside (CO) Line

Pulse (10 pps, 20 pps) or Tone (DTMF)

 

 

 

 

Extension

Pulse (10 pps, 20 pps) or Tone (DTMF)

 

 

 

 

 

Intercom Path

 

3

 

 

 

 

 

 

Mode Conversion

 

Pulse-DTMF

 

 

 

 

 

Ring Frequency

 

20 Hz/25 Hz (selectable)

 

 

 

 

 

 

Operating

Temperature

0 ˚C to 40 ˚C

 

Environment

 

 

 

 

 

 

Humidity

10 % to 90 % (non-condensing)

 

 

 

 

 

 

 

 

Conference Call Outside (CO) Line

2

 

 

 

 

 

 

Music on Hold (MOH)

 

1 port

 

 

 

Selectable MOH: Internal/External/Tone

 

 

 

 

 

Paging

Internal

1

 

 

 

 

 

 

 

External

1 port

 

 

 

 

 

 

Serial Interface Port

RS-232C

1

 

 

 

 

 

 

 

 

USB 1.1

1

 

 

 

 

 

 

 

Extension Connection Cable

SLT

 

1-pair wire (T, R)

 

 

 

 

 

 

 

PT

 

2-pair wire (T, R, H, L)

 

 

 

 

 

 

 

DSS Console

 

1-pair wire (H, L)

 

 

 

 

Dimensions

 

249 mm (W) × 316 mm (H) × 73 mm (D)

 

 

 

Weight (when fully expanded)

Approx. 1.8 kg

 

 

 

 

 

 

Installation Manual

17

 

 

1.3 Specifications

1.3.2Characteristics

Terminal Equipment Loop Limit

PT

40 Ω

 

 

 

 

SLT

600 Ω including set

 

 

 

 

Doorphone

20 Ω

 

 

 

Minimum Leakage Resistance

15 000 Ω minimum

 

 

 

Maximum Number of Extension

1 PT or SLT in standard connection

Instruments per Line

1 PT and 1 SLT in parallel connection

 

 

Ring Voltage

65 Vrms at 20 Hz/25 Hz depending on the ringing load

 

 

 

Outside (CO) Line Loop Limit

1600 Ω maximum

 

 

 

 

Hookswitch Flash/Recall Timing

24 ms–2032 ms

 

Range

 

 

 

 

Door Opener Current Limit

30 V DC/30 V AC, 3 A maximum

 

 

 

Paging Terminal Impedance

600 Ω

 

 

 

 

MOH Terminal Impedance

10 000 Ω

 

 

 

 

18 Installation Manual

1.3 Specifications

1.3.3System Capacity

System Capacity

 

 

TEB308

TEB308TW

 

 

 

 

Basic System

Outside (CO) lines

3

3

 

 

 

 

 

Extensions for PT/SLT

4

4

 

 

 

 

 

Extensions for SLT only

4

 

 

 

 

 

Extensions for PT only

4

 

 

 

 

Maximum Cards and Terminal Equipment

 

Item

TEB308

TEB308TW

 

 

 

 

 

PT

4

8

 

 

 

 

 

SLT

8

4

 

 

 

 

 

2-Port Doorphone Card

1

1

 

 

 

 

 

3-Port Caller ID Card

1

1

 

 

 

 

 

Doorphone

2

2

 

 

 

 

 

Door Opener

2

2

 

 

 

 

 

Pager

1

1

 

 

 

 

 

Music on Hold (MOH)

1

1

 

 

 

 

 

DSS Console

2

2

 

 

 

 

System Data

 

 

Item

Max. Quantity

 

 

Operator

1

 

 

System Speed Dialling

100

 

 

One-touch Dialling

24 per extension (PT)

 

 

Personal Speed Dialling

10 per extension

 

 

Call Park Area

10

 

 

Absent Message

6

 

 

Toll Restriction (TRS) COS

5

 

 

Extension Group

8

 

 

Message Waiting

8 per extension

 

 

Installation Manual

19

 

 

1.3 Specifications

20 Installation Manual

Section 2

Installation

This section describes how to install the Advanced Hybrid System. Detailed instructions for installing the main unit and optional service cards, and cabling of peripheral equipment are provided. Information on system expansion and peripheral equipment installation is included.

Installation Manual

21

 

 

2.1 Before Installing

2.1Before Installing

2.1.1Before Installing

Please read the following notes concerning installation and connection before installing the PBX and terminal equipment.

Be sure to comply with all applicable laws, regulations, and guidelines.

Safety Installation Instructions

When installing telephone wiring, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following:

1.Never install telephone wiring during a lightning storm.

2.Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.

3.Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface.

4.Use caution when installing or modifying telephone lines.

Installation Precautions

This PBX is designed for wall mounting only, and should be installed in a location where it is accessible for inspections and maintenance.

To prevent malfunction, noise, or discolouration, avoid installing the PBX in the following locations:

1.In direct sunlight and hot, cold, or humid places. (Temperature range: 0 ˚C to 40 ˚C )

2.Areas where sulfuric gases may be present, such as near thermal springs.

3.Areas where shocks or vibrations are frequent or strong.

4.High-dust areas, or places the PBX may come into contact with water or oil.

5.Near devices that generate high frequencies, such as sewing machines or electric welders.

6.On or near computers, telexes, or other office equipment, as well as microwave ovens or air conditioners. (It is preferable not to install the PBX in the same room as the above equipment.)

7.Within 1.8 m of radios and televisions. (Both the PBX and Panasonic proprietary telephones should be at least 1.8 m away from such devices.)

8.Locations where other objects will obstruct the area around the PBX. Be especially careful to leave at least 20 cm of space above and 10 cm to the sides of the PBX for ventilation.

Wiring Precautions

Be sure to follow these instructions when wiring the unit:

1.Do not run unshielded telephone cables near AC power cables, computer cables, AC power sources, etc. When running cables near other noise-generating devices or cables, use shielded telephone cables or shield the telephone cables with metal tubing.

2.If cables are run on the floor, use protectors to prevent the cables from being stepped on. Avoid running cables under carpets.

3.Avoid using the same AC outlet for computers, telexes, and other office equipment, as noise generated by such equipment may hamper system performance or interrupt the system.

22 Installation Manual

2.1 Before Installing

4.Use 2-pair telephone cables when connecting Panasonic proprietary telephones (PTs). Use 1-pair telephone cables when connecting single line telephones (SLTs), data terminals, answering machines, computers, voice processing systems, etc.

5.Unplug the PBX from its power source when wiring, and plug the PBX back in only after all wiring is completed.

6.Mis-wiring may cause the PBX to operate improperly. Refer to Section 2, "Installation" when wiring the PBX.

7.If an extension does not operate properly, disconnect the telephone from the extension line and connect it again, or turn off the PBX using the power switch then turn it on again.

8.For safety purposes this unit is equipped with an earthed plug. If you do not have an earthed outlet, please have one installed. Do not bypass this safety feature by tampering with the plug.

9.Use twisted pair cable for outside (CO) line connection.

10.Outside (CO) lines should be installed with surge protectors. For details, refer to "2.4.1 Connecting Outside (CO) Lines", "2.2.8 Installing Surge Protector".

WARNING

Static-sensitive devices are used in this PBX. To protect printed circuit boards from static electricity, do not touch the connectors indicated below. To discharge static electricity from your body, touch ground or wear an earthing strap.

Warning:Static-sensitive connectors

Installation Manual

23

 

 

2.2 Installing the Advanced Hybrid System

2.2Installing the Advanced Hybrid System

2.2.1 Unpacking

The following items are included upon shipment.

Main Unit

1

 

 

AC Cord*

1*

 

 

CD-ROM, Documentation

1 set

 

 

Screw (Wall Mounting)

3

 

 

Washer (Wall Mounting)

3

 

 

Strap

1

 

 

*The type of the AC cord may vary depending on the country/area of use.

More than one type of AC cord may be included for countries/areas in Central and South America.

24 Installation Manual

Loading...
+ 56 hidden pages