Size:
3.72 Mb
Download

Read and Understand this Catalog

Please read and understand this catalog before purchasing the product. Please consult your OMRON representative if you have any questions or comments.

Warranty and Limitations of Liability

WARRANTY

OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

Application Considerations

SUITABILITY FOR USE

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the product in the customer's application or use of the product.

Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used.

Know and observe all prohibitions of use applicable to this product.

NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS

OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

Disclaimers

CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your OMRON representative at any time to confirm actual specifications of purchased product.

DIMENSIONS AND WEIGHTS

Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA

Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.

Printed on 100%

Recycled Paper

Note: Do not use this document to operate the Unit.

OMRON Corporation

Control Devices Division H.Q.

Shiokoji Horikawa, Shimogyo-ku,

Kyoto, 600-8530

Japan

Tel:(81)75-344-7109

Fax:(81)75-344-7149

Regional Headquarters

OMRON EUROPE B.V.

Wegalaan 67-69,NL-2132JD Hoofddorp

The Netherlands

Tel:(31)2356-81-300/

Fax:(31)2356-81-388

OMRON ELECTRONICS LLC

1 East Commerce Drive, Schaumburg,

IL 60173 U.S.A.

Tel:(1)847-843-7900/Fax:(1)847-843-8568

OMRON ASIA PACIFIC PTE. LTD.

83 Clemenceau Avenue,

#11-01,UE Square,

Singapore 239920

Tel:(65)6835-3011/Fax:(65)6835-2711

OMRON (CHINA) CO., LTD.

Room 2211, Bank of China Tower,

200 Yin Cheng Zhong Road,

PuDong New Area, Shanghai, 200120 China

Tel:(86)21-5037-2222/Fax:(86)21-5037-2200

Authorized Distributor:

Note: Specifications subject to change without notice.

Cat. No. V078-E1-09

 

Printed in Japan

 

0206-1M

NS12-V2

NS10-V2NS8-V2

12-inchModel

10-inchModel8-inchModel

NS5-V2

NSH5

5-inchModel

5-inchHand-heldModel

Programmable Terminals

NS-CXDC1-V1

Ver. 1

NS-seriesScreen Creation Software

Installing a Navigator: A Totally New Concept in

Programmable Terminals

NSH5

NS5-V2

NS8-V2

NS10-V2

NS12-V2

5-inch

5-inchModel

8-inchModel

10-inchModel

12-inchModel

Hand-held

 

 

 

 

 

Model

 

 

 

 

 

 

 

 

 

 

 

 

 

NS Series

 

 

 

Make it More Simple

The NS is moving to the next stage, from a touch screen to an advanced machine management tool.

It's convenient but…

Touch

Screen

Operation

 

 

 

Switch

Operation

 

It's convenient but…

We are always trying to

Seamless provide solutions that will give the highest added

value to your system. We strive to solve on-siteproblems with our solutions instead of just providing touch screen functions. That is what OMRON is focused on.

Machine

Management

 

Smart

Turning switches into Touch Screens brings enhancements, such as minimum wiring, space savings, and improved local operation efficiency. Moreover, OMRON works to minimize the customer's energy expenditure from machine design to troubleshooting.

OK!

NS Enters a New Zone

From PLC Memory Allocation to Device Access

Previous PTs shared data that was allocated in advance to specific words in the CPU Unit, and they were used to assist with device operations, and to display error locations, and countermeasures.

PreviousPTPreviouszoneNewzone

PT

PLC

CPU Unit

Allocated data

Sharing allocated data with CPU Unit

NS Series

PLC

Special I/O Units

 

Network

 

Example: DeviceNet

The NS Series achieves flexible data access to a variety of devices. It enables operators to reach the devices on the network including Special I/O Units, intelligent devices, and PLCs.

 

It's time for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

switch inspection.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The cylinder

Intelligent devices

 

 

Smart Active Parts

 

 

speed is strange.

Example: DRT2-seriesSmart Slave

 

 

(Functional software parts)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example: Monitoring maintenance information

for various DeviceNet Smart Slave models

2

3

PTs as a Machine Navigator

NS--seriesi PTs navigatei allll areas off machinei operation,i , fromf dailyily operationi to error recovery..

The PT is traditionally a terminal that exchanges data in

allocated areas with the PLC's CPU Unit. The internal and external control of a PLC with only this type of data exchange is, however, difficult.

A NS-seriesPT, however, uses communications functions and Smart Active Parts to incorporate

software computer functions to operate as a Device Navigator.

Previous

NS Series

Device operations

 

 

PT

 

NS: Device Navigator

Displaying device error locations

Personal computer tool

Displaying countermeasures

Internal device monitoring and resetting

(Supporting recovery methods)

With version 2 PTs (V2 suffix in model number), hardware functions are upgraded.

Large Capacity

Increased Visibility

NS8-V2/NS10-V2/NS12-V2:60 MB

NS8-V2:Increased from 8.0 to 8.4 inches

(-V1:20 MB, same as before)

NS5-V2(STN)/NS12:Wider field of vision

NS5-V2:20 MB

 

Note: TheNS5-V1has a capacity of 6 MB.

Don't you have these problems?

The Smart Active Parts are the solution.

Using all of the device-specific

Previous

 

personal computer tools at startup is

Various device-specifictools

okay, but using the personal

 

 

Peripheral Devices for PLC

computer tools for error recovery

 

Network control

 

Temperature settings and

during operation is overly difficult.

 

Personal computer tools

monitoring tools

 

Setting tool for position control

Wouldn't it be simpler to use the PT instead?

OMRON

With an NS-seriesPT, just drag and drop Smart Active Parts to customize the interface

ORIGINAL

for your machine.

 

 

 

 

 

 

Only with NS!

NS-seriesPTs provide Smart Active Parts that allow direct data access

 

to a variety of devices.

 

 

 

 

 

 

 

PLC System Objects

 

 

Just

Previously

 

 

 

a CX-Programmer

attach to

was required.

a screen.

 

 

 

 

 

Position Control Objects

 

 

 

 

Ensures easy

 

 

 

 

screen settings

Colors and

Example: RS-232C

NS Series

 

in the NCF.

 

 

sizes can be

Example: Ethernet

 

 

 

changed.

 

 

 

 

 

 

 

Parts

 

 

Devices accessed without a program.

Active

DeviceNet Objects

 

Previously

 

Example: DeviceNet

 

a DeviceNet

 

 

 

Smart

 

 

 

Configurator was

 

 

 

 

 

 

 

 

required.

Temperature Controller Parts

ThermoTool was required in the past.

Refer to page 15 of this catalog to see the wide variety of Smart

The Smart Active Parts are accessed by selecting Tools Active Parts. Use Library from the menu bar of theCX-Designer.

4

5

Do you have the following problems when starting the system or when errors occur?

Previous

 

When the System is Started

 

When an Error Occurs during Operation

 

 

PT used for operation after startup.

An error occurs, and…

Data exchange is the main function.

Special personal computer tool

A PT mainly exchanges data with a PLC.Dedicated PC software is required to gain access to other devices.

There is no way for the PT to recover following an error. (Creating a screen is quite troublesome.)

Error

Use a dedicated computer, and you have to wade through functionality that is not being used or that does not need to be reset.

Recovery can only be performed by a specialist (i.e., an engineer).

Only

With the Smart Active Parts

 

 

with

 

 

 

 

 

 

NS!

The PT can be customized according to the specifications of the device manufacturer to optimize

 

 

operation as a tool. This enables equipment maintenance by personnel other than engineers.

Minor maintenance

Customizing and optimizing PT

 

 

 

 

can be performed on

Simply paste one of

 

 

the PT during operation.

the Smart Active

 

 

 

 

Parts! Then make only

 

 

 

 

a few device node

Smart Active Parts

 

 

 

settings.

 

 

 

 

 

 

 

Setting specified

Improved efficiency in creating maintenance screen

parameters and checking status

 

Smart Active Parts

 

access data without

 

any special

 

programming.

Create a screen like this as a device troubleshooter.

When an error occurs, rapid recovery is critical. With the NS Series, the following type of screen can be easily prepared to guide on-siteworkers to carry out the operations required for recovery.

Display explanations of error contents and methods for recovery. (Text file direct specification)

Use diagrams to show error locations and methods for recovery. (Bit map file direct specification)Display only the buttons required for recovery operations.

Notification that an error has occurred

1Error contents and recovery methods are displayed.

No ladder program

Error Recovery Screen Example

Text and BMP files can be directly specified, so operations such as correcting contents for recovery and replacing diagrams and photographs can be executed without requiring any special tools. For example, if the recovery operation procedure is changed by system improvements, screens can be changed by simply replacing text and BMP files, allowing for rapid implementation of improvements and countermeasures.

Note: Transfer tools must be used for transfers.

2 Error location and

3 Recovery operation screen

explanations of recovery

is displayed. (Only the

methods can be further

buttons required for

displayed by bit maps.

operations are shown.)

Note: In addition to the Troubleshooter for the machine above, there is a PLC troubleshooter forCS/CJ-seriesPLCs. Contact your OMRON representative for information on Troubleshooters.

Multi-languageTerminal

Machine Localization with PTs

A Multi-languageInput Environment Using Excel

No special PT tools are required for translation operations.

Translations can be requested using e-mailattachments.

Previous Either a single screen data file was divided between Japanese and English screens, or else multiple screen data files

had to be created.

Label Switching Function for Up to 16 Languages

Devices can be started withJapanese-languagescreens, and then operated with screens in other languages.

The languages can be switch to the one preferred by the device operators.

English and Japanese screen data

Japanese-language

screen

English-language

screen

Chinese screen data

Chinese-language

screen

Dual-languagescreen data

NS project

Because multiple labels can be set, screen data needs to be set only once. Multi-languagecapability is simply a matter of switching labels.

Only

You can get multi-languagesupport in Excel. Switching to as many as 16 languages is as

with

easy as switching labels.

 

 

NS!

Language A screen

Language A

Dual-languageinput in Excel by translation

 

 

companies and local

 

data

Excel data

 

companies

 

 

 

 

NS project

CSV

 

 

 

CSV Attachment

 

 

Dual-language

Language A and B

 

 

screen data

Excel data

 

CSV or

NS project Unicode text

Note: Windows 2000 or XP is required formulti-languagesupport.

16 languages max.

Label 0

 

Label 1

Label 15

 

 

 

CSV Attachment

NS Series

Only with NS!

Multi-LanguagePT

Asian Languages

 

 

Japanese, Simplified Chinese (see note

 

 

1), Korean, and Traditional Chinese

 

 

(see note 2)

 

 

European Languages

 

 

Support for 17 languages

English, French, German, Italian,

Portuguese, Spanish, Swedish, Dutch,

Switching to as many as

Finnish, Norwegian,

Basque, Catalan, and Danish

16 languages by simply

 

 

switching the labels

 

With

Multi-languageconversion has become much easier!

-Designer

 

CX

 

Multi-languageCSV data

Import

Convenient!

When importing screen data, the text attributes of user-specifiedlabels can be applied to all other imported text. With this function, entire Japanese text attributes (e.g., MS Gothic in blue or other colors) can be used in Chinese labels. Furthermore, by using thejust-fitfunction, long labels in English will fit within the frame limits after automatic font adjustment.

Creating Chinese, Korean, or Other Language Screens in Any Language Version of Windows

Multi-languageInput (When Windows 2000 or XP is Used)

When Windows 2000 or XP is being used, Simplified Chinese (see note),

Traditional Chinese (see note), Korean, and other language text can be input in CX-Designer.Select the desired language with Global IME to input a different language.

Note: Simplified Chinese: Chinese with partially simplified characters, mostly used in Mainland China.

Traditional Chinese: Chinese with traditional characters, mostly used in Hong Kong and Taiwan.

6

7

The 5-inchscreen expands your application range.

NS12

Pricei

The NS5 Hand-heldPT has joined the NS family! It expands your application range.

NS10

NS8

NS5

. High-60definitionMBto20

NS features in a compact 5.7-inchhigh-cost-performance model. And, screen capacity has been

!20 MB increased to20 MB

 

Larger, easy-to-operate,

60 MB

10-inchmodel with60 MB

 

screen data capacity

 

displays images from

 

digital cameras.

A bright 8-inchTFT with video board mounting capability. A screen data capacity drastically expanded from20 60 MB

model with 640 x 480 dots.

Visualizing large amounts of information, this powerful, 800 x 600-dot,12-inch-widthmodel allows variable combinations of object arrangements and expands your application.range° .

. °

The NS5 in a 5.7-inchSTNhigh-performancehand-heldmodel.

Screen sizei

NS-seriesLineup

Series

 

NS12

NS10

NS8

 

NS5

NSH5

Appearance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.7 inchs

 

 

 

 

 

 

 

 

 

 

320 x 240 dots

 

 

 

 

 

 

 

 

 

 

 

STN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions

315 x 241 x 48.5 mm

315 x 241 x 48.5 mm

232 x 177 x 48.5 mm

195 x 142 x 54 mm

223 x 176 x

70.5 mm

(WxHxD)

(Not including

depth of

 

 

 

 

 

 

 

 

 

 

emergency stop button)

 

 

 

 

 

 

 

 

 

 

 

 

Effective display area

12.1 inches

10.4 inches

8.4 inches

5.7 inches

5.7 inches

Display device

TFT

TFT

TFT

TFT/STN/monochrome

STN

Number of dots

800 x 600 dots

640 x 480 dots

640 x 480 dots

320 x 240 dots

320 x 240 dots

 

Basic colors

256 colors

256 colors

256 colors

256 colors/

256 colors

 

(objects,

256 colors/

 

background, etc.)

 

 

 

 

 

16 gradations

 

 

 

Display

Image data

32,768 colors

32,768 colors

32,768 colors

32,768 colors/

4,096 colors

(BMP or JPG

4,096 colors/

colors

images)

 

 

 

 

 

16 gradations

 

 

 

 

 

 

 

 

 

 

 

 

 

Images displayed

260,000 colors

260,000 colors

260,000 colors

 

 

 

 

 

 

 

 

 

via video input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Screen data capacity

60 Mbytes

60 Mbytes

60 Mbytes

20 Mbytes

20 Mbytes

Memory Card

 

 

 

 

 

 

 

 

 

 

 

 

 

Ladder Monitor function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Video Input Unit support

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Controller Link

 

 

 

 

 

 

 

 

 

 

 

 

 

Interface Unit support

 

 

 

 

 

 

 

 

 

 

 

 

 

Version 2 Released for All NS-seriesModels.

Greater Screen Capacity and Increased Visibility!

Create 20 MB of screens for the NS5, and an impressive 60 MB of screens for the NS8/NS10/NS12.

Models

Display device model

V 1

V 2

NS 5

MQ (monochrome)

 

 

 

20 MB

 

 

 

TQ (TFT)

 

 

 

20 MB

 

 

 

 

SQ (STN)

6 MB

20 MB

NS 8

TV (TFT)

20 MB

60 MB

NS 10

TV (TFT)

20 MB

60 MB

NS 12

TS (TFT)

20 MB

60 MB

Increased Visibility for the NS5-SQ0(B)-V2,NS8-TV0(B)-V2,andNS12-TS0(B)-V2

NS5-SQ0(B)-V2:STN Models

Field of vision from the top increased by 15

NS8-TV0(B)-V2:TFT Models

LCD increased from 8.0 to 8.4 inches and left/right field of vision increased by 5.°

(External size and panel cutout are the same as previous version.)

NS12-TS0(B)-V2:Bottom field of vision increased by 20

Now On Sale: The NSH5 5-inchHand-heldPT

 

 

 

 

to

 

 

photos

 

digital

 

content

Use

hearts

about

 

.

your

worry

 

 

 

 

less

capacity

with

 

 

 

 

screen

 

 

Just What You've Been Waiting for: The NS5 (STN) in aHand-HeldModel!

Hold the NS5 in the palms of your hands.

Use the Smart Active Parts Library, multi-languagefunctionality, Programming Console feature, and all the other familiar functions of the NS5.

Function

Switches

Use the ten functions switches.

F1, F2, F6, F7: Wired outputs

F3 to F5, F8 to F10: Communications outputs

3-PositionEnable Switch

Increased safety with DPST-NOstructure (wired outputs).

Superior Shock Resistance

Consistent with JIS B 3502, IEC 61131-2(drop shock).

Memory Card Interface and USB Slave Connector.

Easily transfer screens or save logs at high speed using a USB connection.

Emergency Stop Switch.

3PST-NCStructure

DPST-NC:Increase safety (wired outputs).

SPST-NC:Input to internal NSH5 memory, output to a lamp for emergency stop switch operation, or output via communications, e.g., to a PLC.

Water Resistance to IP65

The water-resistantstructure is equivalent to IP65 on all surfaces.

PT and Cable Sold

Separately

Select the Cable according to the application (RS-232C/

RS-422A).Connectorloose wires, UL connector,

3 m or 10 m.

cULus certification is scheduled for the near future for the NSH5 5-inchHand-heldPT.

8

9

USB port included as standard equipment

New functionality added in Ver. 6 extends the ease of use of the NS-seriesPTs.

Smart Active Parts greatly reduce the number of drawing and programming steps.

PT System

Ver. 6 or Higher

Drastically reduce your programming and development time.

Want to check an error or adjust

Solution

 

 

 

 

settings without any software

 

 

 

 

tools. But realization of Touch

 

 

 

 

screen and PLC program are

 

 

 

 

really time consuming.

 

 

 

 

Also, it is dangerous to use

 

 

 

 

software tools since they can do

 

 

 

 

anything. Isn't it possible to

 

 

 

 

show or set one only part of the

 

 

 

 

information?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

See the error log of the PLC without

connecting software.

As an error monitor

Tool Functions Provided with Smart Active Parts

All you need to do is select the required Smart Active Part in theCX-Designerand drag & drop it on the screen see page 5).

Smart Active Parts not only reduce the number of screen drawing and ladder programming steps, but they also eliminate the need to debug.

Software functions are achieved on the screen without software such as the CXProgrammer,CX-Position,and DeviceNet Configurator.

Make PID settings for temperature

control without connecting software. As a setting device for temperature

control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OMRON's

Only one single part is on the screen!

Only three parts are on the screen!

Temperature

 

 

Controller

Refer to page 15 of this catalog to see the wide variety of Smart Active Parts.

(Direct Connection)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Easy screen transfer from anywhere at higher speed.

 

 

PT System

 

 

Ver. 6 or Higher

High-speedscreen transfer through USB.

Note: Lot number 0325 or later is requiredfor USB screen transfer withNS-V1models.

Most computers now have an USB port, and no serial RS-232Cports are provided. You may want to transfer screens more easily at higher speeds.

Solution

Data can be transferred over USB through a single cable between the computer and PT. No devices for serial RS-232Cand USB conversion are required. Moreover, USB allowshigh-speedscreen transfer by just connecting the cable.

Screen transfers equivalent to Ethernet.

Screen transfers using Memory Cards are possible from the maintenance menu.

It is very convenient to make backups without using a computer. It is, however, troublesome to operate a DIP switch on the back of the PT each time backups are required.

You may want to make backups periodically, but worry because the DIP switch pins may break.

 

Screen transfers using Memory Cards are possible

Solution

from the maintenance menu. No physical switch

operations are required on the rear panel.

 

 

Furthermore, easy operation is ensured with no wear

 

and tear of hardware, including the switch.

Memory

Card

Select from

Start downloading/

the system menu.

uploading.

 

Screen transfer through modems is now possible.

Even a single screen change in a shipped machine involves a risk, because a screen sent by e-mailneeds to be transferred to a person familiar with operation. Training workers to understand operation is a hard job. Or service personnel need to visit the site to change screens.

 

The screens can be transferred from a computer in an

Solution

office through modems. The maintenance of

the screens is possible without touching the device.

 

 

Therefore, no training or engineer visits are required.

 

RS-232C

 

Modem

 

Modem

Improved Data Logging

Number of logging points greatly increased.

For example, the PT can log data at 2-secondintervals 24 hours a day (for a43,200-pointlog).

The number of Always Log points has increased from 1,000 to 50,000 max. per line.

The total number of Always Log points increased from 5,000 to 50,000.

Example:

50

times

Logging 1 word and 1 address at 1-secondintervals:

 

 

 

50,000 points, with 50,000 logging points per line.

 

 

 

Logging 1 word and 3 addresses at 1-secondintervals:

10

times

50,000 points, with 16,666 logging points per line.

 

 

 

The number of logging points for one line depends on the number of logging words and the number of logging addresses. For details, refer to the manual.

Logging continues.

For example, you may want to log data at 2-secondintervals 24 hours a day (a302,400-pointlog). This is possible with the NS Series.

When the logging data reaches the number of preset logging points, the logging data can be automatically saved in a Memory Card in CSV format. After automatic saving, the logging data will be cleared. Therefore, it will be possible to continue logging. (The Memory Card can hold a maximum of 1,000 files.)

Example:

Example: Logging 1 word and 1 address at2-secondintervals with the number of logging points set to

43,200 (i.e., at 2-secondintervals for 24 hours a day).

Memory Card

Automatically saved

Logging data for each day (43,200 points) is saved in the Memory Card in CSV format.

LOG001.CSV 04/06/04 10:00

It is possible to

LOG002.CSV 04/06/05 10:00

make a one-week

LOG003.CSV 04/06/06 10:00

log by

LOG004.CSV 04/06/07 10:00

automatically

LOG005.CSV 04/06/08 10:00

saving the data

LOG006.CSV 04/06/09 10:00

seven times.

LOG007.CSV 04/06/10 10:00

 

Suffixes are automatically added to file names set in the CX-Designer.

PT System

Ver. 6 or Higher

Past logs can be seen.

You may want to see logs saved in the past in a Memory Card on the screen. This is possible with the NS Series.

Log data in a Memory Card can be read on the screen with the read file button. A list of files with time stamps will appear on the screen. By selecting the desired file, the past log in the Memory Card can be read.

The log data files in the Memory Card appear as shown below when the read file button is pressed.

Read file button

Standard data can be displayed in the data log.

You may want to save the present log data as standard data in the Memory Card. This is possible with the NS Series.

By pressing the save to file button, the displayed log data can be saved in the Memory Card in CSV format. The saved log data can be overlapped as standard data on the screen by pressing the read file button. By turning the log start address ON and OFF, logged data can be controlled to enable/disable logging.

Log start address

Standard data

Save to file button Read file button

NS-V2Hardware Means High Quality, High Performance, and High Capacity

High definition

Displays image data (BMP and JPG) beautifully.

NS-V2:32,000 colors

NS5

4,096 colors

NS8

32,768 colors

NS10

32,768 colors

NS12

32,768 colors

 

 

Note:NS5-SQ0(B)-V2:STN models have 4,096 colors.

NS5-TQ0(B)-V2:TFT models have 32,768 colors.

USB port compatibility with commercially available printers

Hard copies of screens can be printed out in color by USBcompatible printers.

NS5

Not

 

 

Supported

 

 

NS8

Supported

 

 

NS10

Supported

 

 

 

 

NS12

Supported

 

 

 

 

 

 

EPSON and Canon printers supported.

General printer compatible with USB port

USB cable

Manufacturer: EPSON or Canon Recommended models

EPSON: PM-2200C,PM-930C,PM-870C,PM-740C,PM-900C,PM-D600,PM-G720,PM-G730,PX-A650,PM-G730,PM-D600,PX-A650

Canon: BJ-M70,BJ-M40,PIXUS550i, 50i, 80i, IP2000, IP3100, IP4100, IP4100R, IP90

Large-capacityimage data

Three times the image data capacity for standard models

 

V 1

V 2

 

 

 

 

 

6 MB

20 MB

 

 

 

 

NS5

 

 

 

 

NS8

20 MB

60 MB

 

NS8/10/12-V1

 

NS8/10/12-V2

NS10

20 MB

60 MB

 

 

 

 

NS12

20 MB

60 MB

 

20 MB

 

60 MB

Faster drawing speed

High-speedscreen switching

NS5

See note.

 

NS8

Yes

 

NS10

Yes

 

NS12

Yes

200-MHzRISC CPU

Note: The NS5

High-speedgraphics controller

 

uses a different

 

graphic controller

 

from other models.

 

10

11

The NS Series is more beautiful and user-friendly.

More beautiful

You can make beautiful screens with simple operations.

Windows fonts can be used for switches and lamps Ver.5

Auto font resizing functionVer.5 Automatically resizes fonts to the object size.No need to adjust font sizes manually anymore!

Furthermore, just-fitfont size adjustments have been possible since version 6.

Beautiful BMP Parts Collection has been newly added. Simply select the desired part, paste it on your screen, and make your screens neat!

32,768-colordisplay

The color variation displays pictures brilliantly!

More user-friendly

You can partially replace text and pictures from your computer.

FTP (File Transfer Protocol) has been added! Texts, lists, and recipes can be replaced with the put/get command from your computer! You can even replace BMP files from your computer easily.

Screens, bitmaps, text, recipe data

More strength in applications

The following models, which have an RS-485communications port and

 

The NS can be connected to a Board PC. The NS can also be directly

support CompoWay/F communications, can be connected to the NS.

 

 

 

 

connected to an OMRON Temperature Controller.

 

Unit Series and Models

 

Unit Series and Models

 

Modular Temperature Controllers

Temperature Controllers

 

 

A Memory Link has been added

E5ZN

E5ZN-SCT24S

E5AN/EN

E5AN-

TC

Thermocouple input

 

 

to the communications method.

 

(Terminal Unit)

Series

E5AN-

P

Temperature-resistanceinput

 

 

Digital Controllers

 

 

 

It allows the NS to communicate

 

E5EN-

TC

Thermocouple input

 

 

 

 

 

 

 

E5AR

E5AR03 -FLK

 

E5EN-

P

Temperature-resistanceinput

 

Memory link

with a Board PC.

 

 

 

 

E5ER

E5ER03 -FLK

 

E5AN-

T

Temperature input

 

CompoWay/F

 

 

 

 

 

E5AN-

L

Analog input

 

 

 

 

 

 

E5EN-

T

Temperature input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E5EN-

L

Analog input

Host Link CS/CJ-series,

 

 

 

 

E5CN

E5CN-

TC

Thermocouple input

 

The NS can be directly

 

 

Series

E5CN-

P

Temperature-resistanceinput

CVM1/CV-series,

 

 

 

 

 

 

 

 

E5CN-

T

Temperature input

 

connected to the OMRON

 

 

 

or C-seriesPLC

 

 

 

 

 

E5CN-

L

Analog input

 

 

Temperature Controllers listed

 

 

 

 

OMRON Temperature

 

 

E5GN

E5GN-

TC

Thermocouple input

 

on the right.

 

 

Series

E5GN-

P

Temperature-resistanceinput

PLC

Control Unit

 

 

 

 

 

 

 

System Configurations

Various connections, such as 1:1, 1:2, 1:N, and M:N, are supported with Ethernet or serial connections.

PT:PLC = 1:1

 

PT:PLC = 1:2

 

NS-seriesPT

 

NS-seriesPT

 

 

 

 

 

 

 

RS-232C

RS-232C

 

 

 

Communications without

 

 

Communications without

Communications without

 

 

 

 

programming

programming

programming

 

 

 

 

RS-232C

 

 

 

 

 

(1:1 NT Link, 1:N NT Link,

 

 

 

 

or Host Link)

 

 

 

 

 

 

 

CS/CJ-seriesPLC

C200HX/HG/HE PLC

 

 

 

PLC

 

PT:PLC = M:N

 

 

 

 

PT:PLC = 1:N

 

 

NS-seriesPT

 

 

RS-232C

NS-seriesPT

NS-seriesPT

 

PLC

 

 

 

NS-seriesPT

Communications without

 

 

 

programming

 

 

 

(1:N NT Link)

 

Ethernet

 

 

 

 

 

NS-AL002Converter

 

 

 

(Converts between

CS/CJ-series

 

 

RS-232CandRS-422A.)

PLC

 

PLC

 

 

 

Host Registration Function

 

Ethernet Unit

CS/CJ-seriesPLC

 

 

 

 

 

It is possible to register two or more PLCs as hosts and communicate with the PLCs by specifying the host ID and address when connected via Ethernet or Controller Link.

Powerful Networking

Exchanging Data with a PLC over a Network (Multihost)

Communicating with a PLC via NT Link,

Using Data Links between the PT and the PLC

using Ethernet without Special PLC Programming

Ethernet Communications without Programming

NS-seriesPTs can communicate with a CS/CJseries PLC (equipped with an Ethernet Unit) through“program-free”communications just like NT Link communications. Data is transferred through Ethernet through a simple PLC address and initial communications setup.

Personal computer

Ethernet

Controller Link Interface Unit

The Controller Link is an FA network that can send and receive large data packets flexibly and easily among OMRON PLCs and IBM PC/AT or compatible computers. The NS12 and NS10 PTs can be connected to the Controller Link network easily via a Controller Link Interface Unit. When a Controller Link network is used, data can be transferred between multiple PLCs and NS12/NS10 PTs without writing ladder programming to manage the communications.

 

 

 

 

 

 

 

 

CS/CJ-series

 

Direct access

 

 

 

NS-series

 

 

 

 

 

 

 

 

 

 

 

 

 

PT

PLC

 

 

 

 

 

 

 

 

 

 

 

ControllerLink

Direct access

Direct access

Direct access

 

Direct access

 

 

 

 

 

 

NS-seriesPT

CS/CJ-seriesPLC

NS-series

 

 

 

 

 

 

 

PT

 

 

NS-series

 

 

 

 

PT

 

 

CS/CJ-series

CS/CJ-series

 

Direct access

 

PLC

PLC

 

 

 

 

SPMA (Single Port Multi Access) Function

Screen data can be transferred through the PLC from the CX-Designerto the PT connected to the PLC in series or via a network.

You may want to transfer screens to a PT through the PLC without changing computer connections or to transfer a ladder program to the PLC through the PT by using the Ethernet or Controller Link.

Ladder programs can be monitored or transferred from the CX-Programmerthrough theNS-seriesPT to PLCs connected to the PT in series or via a network.

 

 

 

 

* To use the SPMA function through the PLC, the following

 

 

 

 

software and hardware versions are required.

 

 

Screen data or Data in Memory Card

NS-seriesPT: System version 3.0 or higher

 

 

NS Designer: Version 3.0 or higher or

 

(From CX-Designerthrough PLC toNS-seriesPT)

CX-Designer:Version 1.0 or higher

 

SPMA

 

 

 

CX-Programmer:Version 3.1 or higher

 

 

Ladder program

 

 

PLC: Lot No. 030201 and later (Refer to the following table.)

(From CX-ProgrammerthroughNS-seriesPT to PLC)

PLC series

CPU model

Lot number

 

 

 

 

Computer

CJ1H-CPU65H

 

 

 

 

 

 

CJ1H-CPU66H

 

Ethernet

 

 

 

 

CJ1G-CPU42H

 

 

 

 

 

CJ1G-CPU43H

 

 

 

 

 

 

 

 

CS/CJ-

 

 

CJ Series

CJ1G-CPU44H

 

 

Peripheral

 

CJ1G-CPU45H

030201

NS-seriesPT

series

 

NS-seriesPT

(or RS-232C)

 

CJ1M-CPU11

 

 

 

PLC

 

 

CS/CJ-seriesPLC

CJ1M-CPU12

 

 

 

Serial

 

 

 

 

 

 

 

CJ1M-CPU13

 

 

 

Peripheral

 

 

CJ1M-CPU21

 

 

 

 

 

CJ1M-CPU22

 

 

 

bus

 

 

 

 

Serial

(Tool bus)

Computer

Serial

CJ1M-CPU23

 

 

RS-232C

CS1H-CPU63H

 

 

 

 

 

 

 

 

 

 

NT Link

 

 

NT Link

CS1H-CPU64H

 

 

 

 

 

 

CS1H-CPU65H

 

 

 

 

 

 

CS1H-CPU66H

 

Controller Link

 

 

CS Series

CS1H-CPU67H

030201

 

 

 

 

 

CS1G-CPU42H

 

 

 

 

 

 

CS1G-CPU43H

 

Screen transfer

 

 

 

 

CS1G-CPU44H

 

 

 

 

 

CS1G-CPU45H

 

from the

 

 

 

 

 

Controller Link

 

 

 

Serial

CS1D-CPU42S

 

is supported

 

 

 

NT Link

CS1D-CPU44S

 

from version 6.

 

 

 

CS1D-CPU65S

 

 

 

CS/CJ-seriesPLC

 

 

 

 

NS-seriesPT

NS-seriesPT

CS1D-CPU67S

 

 

 

 

 

12

13

Using Video Inputs

The NS-CA002has joined theNS-CA001Video Input Unit.

You may want to input moving images from a video camera or the image output from a Vision Sensor, arrange them on the PT screen, and capture

(save) the images or display the capture data on the PT.

Display PC Screens with the NS-CA002

NS-CA002RGB/Video Input Unit

(Supported by the NS12-V/NS10-V/NS8-V.)

An analog RGB input terminal is provided in addition to two video input interface terminals. A single video or analog RGB display is possible on the NS-seriesPT. In that case, video display is possible inuser-definedpositions and sizes. Touch switches and parts, such as lamps, can be overlapped on the video display. The display of parts will not disappear.

Saving Displayed Video Images to a Memory Card in BMP Format

Image Capture Function

When necessary, the displayed image can be captured and saved in a Memory Card in BMP format. The saved image can then be uploaded from remote personal computer via Ethernet or Serial connection.

The number of images that can be saved depends on the capacity of Memory Card. As an example, about 50 images from a 640x480 display (about 600 Kbytes each) can be saved in a 30-MbyteMemory Card.

Image capture data read function

PT System

Ver. 6 or Higher

BMP data captured and saved in a Memory Card can be read on the PT. BMP data displayed in thumbnails

can be selected and displayed on the captured data display screen that will appear for the command button.

If an error occurs, the image when the error occurred can be displayed on the NS screen. This is useful for on-siteerror analysis.

RGB

Console

Camera

Note: Two video signals cannot be simultaneously input to a single screen.

NS-CA001Video Input Unit

(Supported by the NS12-V/NS10-V/NS8-V.)

Four video input interfaces are provided, so four video or CCD cameras can be connected. Up to four images can be displayed simultaneously if the image size is 320x240 pixels.

Console

Camera

The NS monitors machine status for who and how machines are managed to help speed recover from problems.

Monitoring and Setting PLC Data

For Operators

Display machine status simply.

Do not want to be aware of ladder programs and PLC memory areas.

Only want to display I/O comments and I/O status.

Solve with the Switch Box function

Solve with the Device Monitor function

Display PLC memory areas without using tools.

Want to display and change the PLC memory areas without showing the PLC program.

Solve with the Ladder Monitor function

Display program without using tools

Want to identify the fault location by checking the actual PLC program.

Want to change part of the program, a timer/counter, without connecting tools.

For Experts

Easily Displaying the Status of Particular Bits in Ladder Programs when Errors Occur

Switch Box Function

The Switch Box Function has been added to the NS-seriesProgrammable Terminals. The Switch Box Function can be used to monitor the status of each bit in a word or a combination of userselected bits organized like a ladder program section. The Switch Box Function makes it possible to perform basic troubleshooting on the factory floor even without a computer.

Monitoring PLC I/O Data for

the Purpose of Device Debugging and Maintenance

Device Monitor Function

The Device Monitor Function is a standard feature in the NS-seriesProgrammable Terminals. Data in the PLC’s I/O memory can be accessed directly (read and written.) The Device Monitor provides functions that can significantly reduce the time needed to set up the system, such as displaying a block of consecutive PLC data area addresses and inputting/verifying parameters in CPU Bus Units and Special I/O Units.

Monitoring Execution of

the PLC's Ladder Program

Ladder Monitor Function

(NS12-V/NS10-V/NS8-V)

The Ladder Monitor Software provided with the CX-Designercan be used to monitor states, search for addresses and instructions, and monitor multiple I/O points at the same time inCS/CJ-seriesPLCs ladder programs via a serial, Controller Link, or Ethernet connection. Copy the Ladder Monitor software to a Memory Card and install the Memory Card in theNS-seriesPT to enable these monitoring and searching operations. It is also possible to display I/O comments created with theCX-Programmerusing an I/O Comment Extract Tool.

From CX-Designerversion 1.0, the Ladder Monitor software is stored in the following folder on theCD-ROM.Copy it to a Memory Card (sold separately) to use it.

CX-OneDisk 3:\Utility\CX-Designer\English\LadderMonitorFunc.

CX-DesignerCD-ROM:\Utility\English\LadderMonitorFunc.

Facilitate Equipment Maintenance

Integrating Special Unit Functions or Component Peripheral Tool Functions into PTs

Smart Active Parts

The following Smart Active Parts are provided and can be installed on the NS-Designer(version 6 or higher).

For CS/CJ AND CS1D CPU Unit

Error Log Monitor, Online Battery Change Button, etc.

For Serial Communications Boards/Units

Communications Status Displays (Error Monitor), Ports Settings, etc.

For Ethernet Units/CLK Units

Network Status Displays (Error Monitor and Network Node Status), etc.

For MC/MCH Unit

JOG Running, Search Zero Position, Program Running, Error Displays, I/O Status Monitor, PV Monitor, etc.

For Inverters (See note.)

Rotation Speed/Monitoring Output Frequency, Other Parameter

Settings, etc.

For DeviceNet

DRT2 Maintenance/Status Information, IN/OUT Information, etc.

For Temperature Controllers (E5R, E5ZN, E5N andCJ1W-TC)

Run Monitor, PID Settings SP Settings, Alarm Settings, Input Correction Settings, etc.

For NC/NCF Unit

For Sensors (E3X-DRT)

JOG Running, Direct Running, Memory Running (NC Only), Error

Threshold Settings, Monitoring Light Reception Levels, Etc.

Displays I/O Status Monitor, PV Monitor, etc.

For the SmartSlice GRT1 Series

Wireless Terminals for WT30

Communications Unit Status, Warning/Alarm Flags, Network

Monitoring Slave Operating Status in a Wireless Environment

Joining/Leaving Status

For Servo (R88D-WT,R7D-AP)(See note.)

 

PV Monitor, Parameter Settings, Error Displays, Driver Information

Note: Smart Active Parts require a Serial Communications Units/Boards

Displays, I/O Status Monitor, etc.

(version 1.2 or later).

 

14

15

High-reliabilityand Advanced Functions in

the Industry’s Slimmest PT

Using a Personal Computer to Check PT Operation

Using a Personal Computer to Check the

Test Mode Window

Virtual PLC address

Operation of Created Functional Objects

 

 

 

 

 

Super-thin48.5-mmBody for a Slimmer Control Panel

This thin-profilemodel has few protrusions so it can be incorporated easily into a panel or machine. The PT can help save space when space is at a premium.

NS12, NS10

Simulation via the “Test Function”

When a test is started, a test screen and virtual PLC will be displayed on the computer.

 

 

Virtual

Test mode

 

PLC address

CX-Designer

 

1

 

 

Set values:

300

300

Present values:

500

500

Start of Test

 

 

 

Set value:

9999

Created screen

Present values: 9999

Operating (clicking with the mouse) the functional objects on the test screen will change the corresponding address in the virtual PLC. Conversely, changing the content of a virtual PLC address will change the corresponding functional objects. It is also possible to confirm pop-upscreens. This function can be used to confirm the actual operation of a screen during the editing.

The test function enables debugging screens without NS and PLC Hardware.

Memory Card interface

Memory Card

Note: Colors shown in photographs and product names may differ from actual colors and names.

Expansion interface

Battery

Transferring Screen Data to the PT On-sitefrom a Memory Card

Memory Card: Upload/Download Function

CX-Designer

 

 

 

 

 

 

 

 

 

 

 

It is possible to download the screen data and system

 

 

 

 

 

Screen data

 

NS-seriesPT

 

 

 

 

 

program to Memory Card and upload the same data from

 

 

 

 

 

 

 

 

 

Screen data

 

 

 

 

 

Automatic transfer

the Memory Card. It is also possible to automatically

 

 

 

 

 

 

 

 

 

 

 

 

when power of PT

upload the data from the Memory Card to CX-Designeror

Memory

 

 

 

 

 

 

is turned ON.

 

 

 

 

 

 

 

 

 

 

 

 

automatically download the data from Memory Card to PT

Card

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Memory Card

when the power of PT is turned ON.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NS-seriesPT

 

 

 

 

 

Using General Software

Setting Functional Object Properties in Excel

CSV File Input/Output

The property settings for each functional object can be exported in CSV format. The settings data can be imported again after it has been edited with a program such as Excel.

Editing Text and Bitmap File with Your Favorite Text Editor

Editor Specifying Function

The user can select the editor when editing text or bitmap files.

Creating System-relatedDocuments

Outputting Project Information in RTF

Data such as screen information and object information can be output in an RTF file. The RTF file can be read into Word Processor to produce a system manual.

Example of an RTF File Read into Word Processor

Using Excel to Analyze Data, Such as the Alarm/Event History, Operation Log, and Error Log, and to Create Daily Reports

Memory Card: Data Logging Function

Logging data (trend data, up to 50,000 points with a sampling cycle of 0.5 or 1 to 86,400 s/group) can be stored in the Memory Card in CSV format.

Logging of trend data

Memory Card

Using Excel to Analyze Time-seriesData and to Create Daily Reports

Power Supply (24 VDC)

USB HOST (for printer)

NS8

Power

Supply

(24 VDC)

Ethernet (10Base-Tor100Base-TX)

USB SLAVE (For screen data transfer)

Memory Card interface

Expansion interface

RS-232Cserial port A

RS-232Cserial port B

A bar code reader can be connected to the serial port.

Recommended bar code reader: V520-RH21-6

Memory Card

Note: Colors shown in photographs and product names may differ from actual colors and names.

Battery

RS-232Cserial port A

A bar code reader can be connectedRS-232Cserial port Bto the serial port.

Recommended bar code reader: V520-RH21-6

Ethernet

(10Base-Tor100Base-TX)

USB SLAVE (For screen data transfer)

USB HOST (for printer)

Pasted Screen Data as

 

Object Properties as

RTF Data

 

RTF Data

 

 

 

 

 

 

Memory Card: History Storage Function

The following data can be saved to the Memory Card in CSV format.

Alarm/Event History (Alarm/ Event history data)

Operation Log (Screen operation history data)

Error Log (Error log data recorded during macro program execution)

 

Built-inExpansion Interface

 

USB Ports

 

 

 

 

The NS-seriesPTs have abuilt-inExpansion Interface for

A printer can be connected to the USB HOST port.

future expandability.

Refer to Printer Support on page 10 for recommended

 

 

printers.

16

17

Dimensions

NS5

Battery

Power Supply

(24 VDC)

Memory Card interface

Memory Card

Note: Colors shown in photographs and product names may differ from actual colors and names.

Expansion interface

Ethernet (10Base-Tor100Base-TX)

USB SLAVE (For screen data transfer)

RS-232Cserial port A

RS-232Cserial port B

A bar code reader can be connected to the serial port.

Recommended bar code reader: V520-RH21-6

Optional Products

Video Input Unit

RGB/Video Input Unit

Controller Link Interface Unit

RS-422AAdapter

NS-CA001(withCover)

NS-CA002(with cover)

NS-CLK21(with Cover)

CJ1W-CIF11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Protective Cover/Anti-reflection

 

 

 

RS-232/RS-422AConversion

 

Sheet for NS-seriesPT

 

 

 

Communications Cable

NS -KBA0(N)

USB Serial Conversion Cable

Unit NS-AL002

XW2Z-S002

NT30/NT31C-KBA05(N)

CS1W-CIF31

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: Colors shown in photographs and product names may differ from actual colors and names.

NS12/10 PTUnits: mm

 

 

140

241

227

249

 

 

 

 

 

15.5

 

7.5

39 (min.)

 

264

 

 

 

315

 

48.5

42 (max.)

 

323

 

49

 

 

 

 

 

 

 

 

301

 

 

 

 

 

 

 

Recommended

 

 

 

 

Panel Cutout Dimensions

 

 

SW

 

 

 

 

 

RESET

 

 

 

24V

 

121

 

 

228–0+1

DC

 

 

 

 

 

 

PORT B PORT A

134

 

 

 

HOST

SLAVE

 

 

 

 

ETHERNET

 

 

 

 

 

 

 

302 –0+1

 

3.8

13.7

 

 

 

 

 

 

 

 

 

23

49.9

 

 

 

 

 

90.4

 

 

 

 

NS5 PT Units: mm

 

 

 

 

39.83

 

195

 

 

 

 

 

 

 

 

27.3

ÇqÇtÇm

 

 

153.3

44.55

142

 

 

130.5

 

 

 

 

 

 

 

15.5

5

34 (min.)

 

 

145

90

 

53.8

38 (max.)

 

 

206.3

 

 

 

 

54.8

 

 

 

 

 

 

 

 

 

183.5

 

 

 

Recommended

Panel Cutout Dimensions

PORT B

PORT A

 

131

–0+0.5

 

 

68.48

 

 

 

 

 

 

ETHERNET

 

 

 

21

 

184 –0+0.5

 

 

51.7

 

 

19.5 77

NS8 PT Units: mm

 

 

177

 

165

188

 

 

15.5

 

5

39 (min.)

 

 

180

 

 

 

 

 

 

48.5 42 (max.)

 

 

232

 

 

 

 

 

 

 

 

 

 

 

 

 

49

 

 

 

220

 

 

 

 

 

 

 

 

 

Recommended

 

 

 

 

 

Panel Cutout Dimensions

 

SW

 

 

 

 

 

 

RESET

 

 

 

 

 

24V

 

 

 

 

165.5

+0.5

120.5 DC

PORT B PORT A

107.6

 

 

 

–0

HOST

SLAVE

 

 

 

 

 

 

ETHERNET

 

 

 

 

 

 

 

19.1

 

220.5 –0+0.5

 

 

 

 

 

 

26.69.6

44.150.1

63.4

NS5 Hand-heldPT

Units: mm

223

16.5

70.5

176

NS-CA001Video Input Unit

Units: mm

 

 

81.3

 

 

 

 

(102.7)

9.6

 

21.4

 

 

 

164

5

 

 

(169)

 

 

(1.9)

127.3

 

 

 

 

 

(22.3)

 

9.7

20.4

10.6

 

 

11

50.3

 

 

 

 

 

 

68.3

 

 

 

86.3

 

 

 

104.3

 

 

NS-CA002Video Input Unit

Units: mm

 

81.3

 

 

 

(102.7)

9.6

21.4

 

164

5

 

(169)

 

 

(1.9)

 

 

(22.3)

9.7

20.4

11.1

 

11

 

 

39.3

 

 

57.3

 

 

82.8

 

 

118.3

 

 

NS-CLK21

Controller Link Interface Unit

Units: mm

151.5

(183)

 

31.5

164

5

(169)

 

(1.9)

(33.9)

10.8

32

 

 

11

 

95.6

 

18

19

Performance/Specifications

General Specifications

NS12/NS10/NS8/NS5-V2

Item

Specifications

Rated power supply voltage

24 VDC

Allowable voltage range

20.4 to 27.6 VDC (24 VDC ±15%)

Power consumption

25 W max. (15 W max. for the NS5)

Ambient operating temperature

0 to 50°C (See notes 1 and 4.)

Storage temperature

–20to 60°C (See note 2.)

Ambient operating humidity

35% to 85% (0 to 40°C) with no condensation

35% to 60% (40 to 50°C) with no condensation

 

Operating environment

No corrosive gases.

Noise immunity

Conforms to IEC61000-4-4,2 kV (power lines)

Vibration resistance

Conforms to JIS C0040.

10 to 57 Hz, 0.075 mm amplitude, 57 to 150 Hz,

(during operation)

9.8 m/s2 30 min each in X, Y, and Z directions

Shock resistance

Conforms to JIS C0041.

(during operation)

147 m/s2 3 times each in direction of X, Y, and Z.

Weight

NS12: 2.5 kg max.; NS10: 2.3 kg max.;

NS8: 2.0 kg max.; NS5: 1.0 kg max.

 

Enclosure rating

Front operating panel: IP65F and NEMA4 compliant

(See note 3.)

 

Battery life

5 years (at 25°C) Replace battery within 5 days

after the battery runs low (indicator lights orange).

 

Applicable standards

cULus and EC directives

 

 

Note 1: The operating temperature is subject to the following restrictions according to the mounting angle.

Mounting angle of 0 to 30° to the horizontal: Operating temperature range of 0 to 45°C

When a Video Input Unit or a Controller Link Interface Unit is mounted, the ambient operating temperature is 0 to 35°C.

Mounting angle of 30 to 90° to the horizontal: See note 4.

Note 2: Operate the PT within the temperature and humidity ranges shown in the following diagram.

Humidity (%)

 

 

 

 

 

 

 

Storage

 

95% 80%

 

 

 

 

 

 

 

 

 

 

60%

 

 

 

 

 

 

 

Operation

60

 

90°

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50

 

 

40%

 

surface

 

 

 

 

 

 

 

 

 

 

 

 

Temperature (°C)

 

40

 

 

 

35%

Display

 

30°

 

 

 

30

 

 

 

 

 

 

 

 

 

 

 

 

20%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

20

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

10%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Horizontal

—20

0

10

20

30

40

50

60

70

80

 

 

(0°)

 

 

 

 

 

Temperature (°C)

 

 

 

 

 

 

 

 

 

 

Note 3: May not be applicable in locations withlong-termexposure to oil.Note 4: •NS12/NS10/NS5

Mounting angle of 30° to 90° or less to the horizontal: Operating temperature range of 0 to 50°C •NS8

Mounting angle of 30° to less than 90° to the horizontal: Operating temperature range of 0 to 45°C Mounting angle of 90° to the horizontal: Operating temperature range of 0 to 50°C

NSH5-SQROOB-V2

Item

Specification

Rated power supply voltage

24 VDC

Allowable voltage range

20.4 to 26.4 VDC (24 VDC –15%/+10%)

Power consumption

10 W max.

Ambient operating temperature

0 to 40°C

Storage temperature

–20to 60°C

Ambient operating humidity

35% to 85% with no condensation

Operating environment

No corrosive gases.

 

Common mode: 1,000 Vp-p(between power

Noise immunity

supply terminals and panel)

Normal mode: 300 Vp-p

 

 

Pulse width: 100 ns to 1 µ s, Rise time: 1-nspulse

Vibration resistance

Conforms to JIS C0911.

(during operation)

 

Shock resistance

Conforms to JIS C0912.

(during operation)

 

Weight

1 kg max.

Enclosure rating

IP65 compliant

Ground

Ground to 100 Ω or less.

Applicable standards

UL508 and EC directives

Characteristics

Display Specifications

 

Item

NS12-V2

NS10-V2

NS8-V2

NS5-V2/NSH5-V2

 

Display device

High-definitionTFT color LCD

TFT color LCD

 

STN color LCD

 

 

 

 

 

Monochrome LCD

 

Number of dots

800 dot horizontal x

640 dot horizontal x 480 dot vertical

320 dot horizontal x

 

 

600 dot vertical

240 dot vertical

 

Display color

 

256 colors

 

 

Display

Effective

Width 246.0 mm x

Width 215.2 mm x

Width 170.9 mm x

Width 117.2 mm x

 

height 184.5 mm

height 162.4 mm

height 128.2 mm

height 88.4 mm

panel

display area

(12.1 inches)

(10.4 inches)

(8.4 inches)

(5.7 inches)

 

 

 

 

 

 

 

TFT: Left/right 70°,

 

 

 

Left/right ±60°,

Left/right ±60°,

Left/right ±65°,

Top 70°, bottom 50°

 

Field of vision

STN: Left/right 50°,

 

Top 45°, bottom 75°

Top 35°, bottom 65°

Top 50°, bottom 60°

Top 45°, bottom 50°

 

 

(See note 1.)

 

 

Monochrome:

 

 

 

 

 

Left/right 45°,

 

 

 

 

 

Top 20°, bottom 40°

 

 

 

 

 

 

TFT, STN: 75,000

 

 

 

 

 

hours min. (See

 

Service life

50,000 hours min. (See note 2.)

 

note 2.)

Backlight

 

 

 

 

Monochrome:

 

 

 

 

50,000 hours min.

(See note

 

 

 

 

(See note 2.)

5.)

Brightness

There are 3 levels that can be set with the touch panel. (See note 3.)

 

 

 

adjustment

 

Backlight error

 

Error is detected automatically, and the RUN

 

 

 

detection

 

indicator flashes green as notification. (See note 4.)

 

 

Note 1: The bottom angle is 55° for V1 models.

2: This is the estimated time before brightness is reduced by half at room temperature and humidity. It is not a guaranteed value. The service life will be drastically shortened if PT is used at low temperatures. For example, using the PT at temperatures of 0°C will reduce the service life to approximately 10,000 hours (reference value).

3: The brightness cannot be adjusted much.

4: This function does not indicate that the service life has been reached. It detects when the backlight is not lit due to a disconnection or other errors. Backlight error detection indicates that all backlights (2) are OFF.

5: Contact your nearest OMRON representative to replace the backlight.

Operating Specifications

 

Item

 

 

Specification

 

Method

 

Resistive membrane

 

 

NS12-V2

1,900

(50 horizontal x 38 vertical) 16 x 16 dots for each switch.

Touch

Number

NS10-V2

1,200

(40 horizontal x 30 vertical) 16 x 16 dots for each switch.

panel

of

NS8-V2

768

(32 horizontal x 24 vertical) 20 x 20 dots for each switch.

(Matrix

switches

type)

 

NS5-V2/NSH5

300

(20 horizontal x 15 vertical) 16 x 16 dots for each switch.

 

 

 

Input

 

Pressure-sensitive

 

Service life

1,000,000 touch operations.

 

 

 

 

 

Data Capacity Specification

Series

Display device model

 

 

V 1

V 2

NS5

 

MQ (monochrome)

 

 

 

 

20 MB

 

 

 

 

 

 

TQ (TFT)

 

 

 

 

20 MB

 

 

 

 

 

 

 

SQ (STN)

 

6 MB

20 MB

NSH5

 

SQ (STN)

 

 

 

 

20 MB

 

 

 

 

 

NS8

 

TV (TFT)

 

20 MB

60 MB

NS10

 

TV (TFT)

 

20 MB

60 MB

NS12

 

TS (TFT)

 

20 MB

60 MB

External Interface Specifications

 

 

 

 

 

 

 

 

 

 

 

Item

 

Specifications

 

Memory card

 

One ATA-CompactFlash interface slot.

 

interface

 

Used to transfer and store screen data and to store history data.

Expansion

 

For Expansion Interface Units

 

 

 

 

interface

 

 

 

 

 

 

 

Communications Specifications

Serial Communications

Item

Specification

 

 

Conforms to EIA RS-232C.Port AD-Subfemale9-pinconnector

5-Voutput (250 mA max.) through pin 6 (See note.)

Conforms to EIA RS-232C.Port BD-Subfemale9-pinconnector

5-Voutput (250 mA max.) through pin 6 (See note.)

Note: The 5-Voutputs of serial ports A and B cannot be used at the same time.

Controller Link(Wired-type)Specifications

Item

Specification

Baud rate

2M/1M/500K

Transmission path

Shielded twisted-paircable (special cable)

Ethernet Specifications

Item

Specification

Conformance standards

Conforms to IEEE 802.3/Ethernet (10Base-T/100Base-T).

Video Input Specifications

Item

NS-CA001

NS-CA002

Resolution

320 x 240, 640 x 480, or 800 x 600 dots

User-definedsize

Input signal

NTSC composite video or PAL

NTSC composite

 

 

video or PAL

Cameras

Number of cameras: 4 max.

2 cameras + RGB

USB Specifications

Item

Specifications

USB rating

USB1.1

Connector

Type A (Host), Type B (Slave)

Compatible OMRON PLCs

CPU Units (1:1 NT Link Connection)

Display Element Specifications

 

Item

 

Specification

 

 

Raster font

Displayable characters

 

Base size

 

 

 

 

 

Rough

Alphanumeric characters

 

8 x 8

1 x 1, 1 x 2, 2 x 1,

 

 

 

 

or Japanese katakana

 

2 x 2, 3 x 3, 4 x 4, 8 x 8

 

 

 

 

 

 

 

 

 

Font

Standard

Alphanumeric characters

 

 

 

 

 

or Japanese, Chinese

 

8 x 16

1 x 1, 1 x 2, 2 x 1,

Display

 

name

 

(Simplified, Traditional)

 

16 x 16

2 x 2, 3 x 3, 4 x 4, 8 x 8

text

 

 

 

 

or Korean

 

 

 

 

 

 

 

Fine

Alphanumeric characters

 

16 x 32

1 x 1, 1 x 2, 2 x 1,

 

 

 

 

or Japanese katakana

 

32 x 32

2 x 2, 3 x 3, 4 x 4, 8 x 8

 

 

 

 

 

Japanese kanji

 

 

 

 

 

 

 

 

 

 

Vector font

Can be specified in CX-Designer.

 

(text objects only)

Font, style, and size can be specified.

 

Color

 

256 colors

 

 

Text

Font style (only when

Bold or italic

 

 

vector font is specified)

 

 

attributes

 

 

 

 

Vertical alignment

Top, center, or bottom

 

 

 

 

 

 

Horizontal alignment

Left-justified,centered, orright-justified

 

Objects

 

Functional

Up to 10 types can be registered.

 

 

objects

The flicker speed and flicker range can be set.

Flicker

that can

 

 

Fixed

Select from 3 types.

 

 

 

flicker

 

 

 

 

 

 

 

objects

The flicker speed and flicker range are fixed.

Numeral units and scale settings

1,000 max.

 

 

Alarm/event settings

 

5,000 max.

 

 

Display colors

 

256 colors max. (32,768 colors for BMP)

CX-OneOperating Environment

Compatible OS

Windows 98 SE, Me, NT 4.0 (Service Pack 6a), 2000 (Service

Pack 3 or higher), or XP (See note 1.)

 

Recommended CPU

Pentium II 333 MHz or faster processor (Pentium III 1 GHz or

faster recommended.)

 

Recommended memory

256 Mbytes min. (See note 2.)

Hard disk free space

Approx. 1.8 GB or more available space is required to install

 

the complete CX-Onepackage.

CD-ROMdrive

Required for installation

Display

SVGA (800 x 600) or better high-resolutiondisplay with 256 colors min.

Note 1:CX-OneOS precaution

The CX-Onewill not run on Microsoft Windows 95 or any other OS not listed above.

If such an OS is being used on the client computer, the OS must be upgraded before installing the CX-One.System requirements and hard disk space may vary with the system environment.

2: The amount of memory required varies the Support Software applications used inCX-One.Refer to use documentation for Individual Support Software for details.

 

 

 

Model number

Specifications

PLC model name

CQM1-CPU41-V1/CPU42-V1/CPU43-V1/CPU44-V1

With RS-232Cconnector(9-pintype)

C-seriesCQM1

CQM1H-CPU21/CPU51/CPU61

 

C-seriesCQM1H

CPM1-10/20CDR-+CPM1-CIF01

Connect to peripheral port.

C-seriesCPM1

CPM1A-10/20/30/40CD

-

+ CPM1-CIF01

C-seriesCPM1A

 

CPM2A-30/40/60CD

-

+ CPM1-CIF01

Connect to RS-232Cor peripheral port.

C-seriesCPM2A

CPM2C-10/20

 

- (See note 1.)

 

C-seriesCPM2C

C200HS-CPU21/CPU23/CPU31/CPU33

 

C-seriesC200HS

C200HE-CPU32(-Z)(See note2.) /CPU42(-Z)

With RS-232Cconnector(9-pintype)

C-seriesC200HE(-Z)

C200HG-CPU33(-Z)(See note2.) /CPU43(-Z) /CPU53(-Z)(See note2.) /CPU63(-Z)

 

C-seriesC200HG(-Z)

C200HX-CPU34(-Z)(See note2.) /CPU44(-Z) /CPU54(-Z)(See note2.) /CPU64(-Z) /CPU65-Z/CPU85-Z

 

C-seriesC200HX(-Z)

CV500/1000/2000-CPU01-V1

With RS-232Cconnector(switching/9-pintype)

CVM1/CV-series

CVM1 or CV500/

CVM1-CPU01-V2/CPU11-V2/CPU21-V2

 

CV1000/CV2000

 

 

 

 

 

Note 1: Use an Adapter Cable(CPM2C-CN111orCS1W-CN114/118),CPM1-CIF01RS-232CAdapter, orCPM1-CIF11RS-422AAdapter to connect.

 

 

2: AC200HW-COM02(-V1),C200HW-COM04(-V1),C200HW-COM05(-V1),orC200HW-COM06(-V1)Communications Board is required.

 

 

CPU Units (1:N NT Link Connection)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model number

Specifications

PLC model name

CS1G-CPU42H/CPU43H/CPU44H/CPU45H

 

CS-seriesCS1G

CS1H-CPU63H/CPU64H/CPU65H/CPU66H/CPU67H

 

CS-seriesCS1H

CS1D-CPU65H/CPU67H

 

 

 

CS-seriesCS1D

CJ1G-CPU42H/CPU43H/CPU44H/CPU45H(See note 1.)

 

CJ-seriesCJ1G

CJ1G-CPU42P/CPU43P/CPU44P/CPU45P

 

CJ-seriesCJ1G

CJ1H-CPU65H/CPU66H/CPU67H(See note 1.)

With RS-232Cconnector(9-pintype)

CJ-seriesCJ1H

CJ1M-CPU11/CPU12/CPU13/CPU21/CPU22/CPU23(See note 1.)

CJ-seriesCJ1M

 

CQM1H-CPU61/51with aCQM1H-SCB41Serial Communications Board

 

C-seriesCQM1H

C200HE-CPU32(-Z)(See note2.) /CPU42(-Z)

 

C-seriesC200HE(-Z)

C200HG-CPU33(-Z)(See note2.) /CPU43(-Z) /CPU53(-Z)(See note2.) /CPU63(-Z)

 

C-seriesC200HG(-Z)

C200HX-CPU34(-Z)(See note2.) /CPU44(-Z) /CPU54(-Z)(See note2.) /CPU64(-Z) /CPU65-Z/CPU85-Z

 

C-seriesC200HX(-Z)

Note 1: TheCJ1W-SCU21/SCU41Serial Communications Unit can also be connected.

2: AC200HW-COM02/COM04/COM05/COM06(-V1)Communications Board is required.

20

21

Connections through CPU Unit/Host Link

 

Model number

Specifications

PLC model name

 

CPM1-10CDR/20CDR- /CPM1A-10CD/20CD/30CD/40CD-

RS-232CorRS-422Aadapter connected to peripheral port

C Series: CPM1

 

CPM2A-30CD/40CD/60CD-

RS-232Cconnector(9-pin)

C Series: CPM2A

 

 

 

Communications connectors include both a peripheral port and

C Series: CPM2C

 

CPM2C-10/20

-

RS-232Cport (branching possible throughCPM2C-CN111

 

 

Conversion Cable).

 

 

 

 

Used as separate peripheral and RS-232Cports through CS1W-

 

 

 

 

CN114/118 Conversion Cable.

 

 

CQM1-CPU21/CPU41-V1/CPU42-V1/CPU43-V1/CPU44-V1

RS-232Cconnector(9-pin)

C Series: CQM1

 

CQM1H-CPU11/CPU21/CPU51/CPU61

RS-232Cconnector(9-pin)(Only peripheral port forCQM1H-CPU11)

C Series: CQM1H

 

C200HS-CPU21/CPU23/CPU31/CPU33

 

C Series: C200HS

 

C200HE-CPU32(-Z)(Seenote.)/CPU42(-Z)

RS-232Cconnector(9-pin,selectable)

C Series: C200HE (-Z)

 

C200HG-CPU33(-Z)(Seenote.)/CPU43(-Z)/CPU53(-Z)(Seenote.)/CPU63(-Z)

C Series: C200HG (-Z)

 

 

 

C200HX-CPU34(-Z)(Seenote.)/CPU44(-Z)/CPU54(-Z)(Seenote.)/CPU64(-Z)/CPU65-Z/CPU85-Z

 

C Series: C200HX (-Z)

 

CS1G-CPU42(-V1)/CPU43(-V1)/CPU44(-V1)/CPU45(-V1)

RS-232Cconnector(9-pin)

CS Series: CS1G

 

CS1H-CPU63(-V1)/CPU64(-V1)/CPU65(-V1)/CPU66(-V1)/CPU67(-V1)

CS Series: CS1H

 

 

 

CV500-CPU01-V1/CV1000-CPU01-V1/CV2000-CPU01-V1/

RS-232Cconnector(9-pin,selectable)

CVM1/CV Series:

 

CV500/1000/2000 or

 

CVM1-CPU01-V2/CPU11-V2/CPU21-V2

 

 

 

CVM1

 

 

 

 

 

: TheNoteC200HW-COM02,C200HW-COM04,C200HW-COM05,orC200HW-COM06(-V1)Communications Board is required.

Standard Models

Model

Specifications

 

 

Model number

Standards

name

Ethernet

Case color

 

 

 

 

 

No

Ivory

NS12-TS00-V2

CU, CE

NS12

12-inchTFT

Black

NS12-TS00B-V2

CU, CE

 

800 x 600 dots

 

Ivory

NS12-TS01-V2

CU, CE

 

 

 

 

Yes

 

 

Black

NS12-TS01B-V2

CU, CE

 

 

 

 

 

No

Ivory

NS10-TV00-V2

CU, CE

NS10

10-inchTFT

Black

NS10-TV00B-V2

CU, CE

 

640 x 480 dots

 

Ivory

NS10-TV01-V2

CU, CE

 

 

 

 

Yes

 

 

Black

NS10-TV01B-V2

CU, CE

 

 

 

 

 

No

Ivory

NS8-TV00-V2

CU, CE

NS8

8-inchTFT

Black

NS8-TV00B-V2

CU, CE

 

640 x 480 dots

 

Ivory

NS8-TV01-V2

CU, CE

 

 

 

 

Yes

 

 

Black

NS8-TV01B-V2

CU, CE

 

 

 

 

 

No

Ivory

NS5-SQ00-V2

CU, CE

 

5-inchSTN

Black

NS5-SQ00B-V2

CU, CE

 

 

 

320 x 240 dots

Yes

Ivory

NS5-SQ01-V2

CU, CE

 

 

 

 

Black

NS5-SQ01B-V2

CU, CE

 

 

 

 

 

No

Ivory

NS5-TQ00-V2

CU, CE

NS5

5-inchTFT

Black

NS5-TQ00B-V2

CU, CE

 

320 x 240 dots

 

Ivory

NS5-TQ01-V2

CU, CE

 

 

 

 

Yes

 

 

Black

NS5-TQ01B-V2

CU, CE

 

 

 

 

 

No

Ivory

NS5-MQ00-V2

CU, CE

 

5-inch

Black

NS5-MQ00B-V2

CU, CE

 

 

 

monochrome

 

 

 

Ivory

NS5-MQ01-V2

CU, CE

 

320 x 240 dots

Yes

 

 

Black

NS5-MQ01B-V2

CU, CE

 

 

 

NS5

5-inchSTN

 

 

 

CE,

No

Black

NSH5-SQR001B-V2

CU

Hand-held

320 x 240 dots

(approval

 

 

 

 

 

 

 

 

pending)

 

 

 

 

 

 

Model name

Specifications

 

Model number

 

 

 

 

 

The CX-Oneis an integrated

1 license

CXONE-AL01C-E

 

tool package that provides

 

programming and monitoring

 

 

 

software for OMRON PLCs and

 

 

 

components. The CX-Oneruns

3 licenses

CXONE-AL03C-E

CX-One

on any of the following

 

 

operating systems:

 

 

 

 

FA Integrated

Windows 98 SE, Me, NT 4.0

10 licenses

CXONE-AL10C-E

Tool Package

(Service Pack 6a), 2000 (Service

 

 

Ver. 1.1

Pack 3 or higher), or XP.

 

 

 

 

 

CX-Designerversion 1. is

30 licenses

CXONE-AL30C-E

 

included in the CX-One.

 

Refer to the CX-Onecatalog

 

 

 

(R134) for details.

 

 

 

(See note 2.)

50 licenses

CXONE-AL50C-E

 

 

 

 

The CX-Designercan also be ordered individually using the following model number.

 

 

 

OS: Window 98 SE, Me, NT 4.0

 

 

 

CX-Designer

 

(Service Pack 6a),

 

 

 

 

 

2000 (Service Pack 3 or

 

1 license

NS-CXDC1-V1

 

Ver. 1.

 

higher), or XP.

 

 

 

 

 

 

 

 

 

The Ladder Monitor Software

 

 

 

 

 

 

is included.

 

 

 

 

 

 

Screen transfer cable for DOS/V

XW2Z-S002

 

 

 

 

 

 

 

 

USB Host Cable, cable length: 5 m

NS-US52(5 m)

Cable

 

 

 

 

 

 

 

USB Host Cable, cable length: 2 m

NS-US22(2 m)

(See note 1.)

 

 

 

 

 

 

 

 

USB-RS-232CConversion Cable,

CS1W-CIF31

 

 

 

 

 

 

cable length: 0.5 m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS-422Acable (loose wires)

 

 

NSH5-422CW-10M

 

 

 

Cable length: 10 m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NSH5 Cables

 

RS-232Ccable (loose wires)

 

 

NSH5-232CW-3M

 

Cable length: 3 m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS-232Ccable (loose wires)

 

 

NSH5-232CW-10M

 

 

 

Cable length: 10 m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PT-to-PLC

 

PT connection: 9 pins

 

Length: 2 m

XW2Z-200T

Connecting Cable

 

PLC connection: 9 pins

 

Length: 5 m

XW2Z-500T

 

 

 

 

 

 

 

 

 

 

 

 

NSH5 Wall-mountingBracket

 

 

NSH5-ATT02

:Use anNoteOMRON1 USB Host Cable to connect anNS-seriesPT to a printer.

:Site licenses2 are also available for users that need to use theCX-Oneon many computers.

Ask your OMRON representative for details.

Options

 

 

Model name

 

 

Specifications

 

Model number

 

 

 

 

 

 

 

Inputs: 4 channels

 

NS-CA001

 

 

 

 

 

 

 

Signal type: NTSC/PAL

 

 

 

 

 

 

 

 

 

Video Input

 

Input channels: 2 video

 

 

Unit

 

 

 

 

channels and 1 RGB

 

NS-CA002

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

channel (See note.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Signal mode: NTSC/PAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Special Cable for the Console

 

F150-VKP(2m)

 

 

F150-VKP(5m)

 

 

 

 

 

 

 

 

 

 

 

 

Controller Link

 

 

For Controller Link

NS-CLK21

 

Interface Unit

 

 

Communications

 

 

 

 

 

 

 

 

 

 

Transmission distance:

 

 

 

 

 

 

 

 

500 m total length

 

 

 

 

:

UseNotethis model when

 

NS-AL002

 

 

 

 

 

 

connecting PT models without a V

 

 

 

 

 

 

suffix.

 

 

 

 

:

PT mNodtels with a suffix of V

 

 

 

RS-422A

 

can also be connected.

 

 

 

Adapter

 

 

Transmission distance:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50 m total length

 

 

 

 

:

OnlyNotePT models with a suffix

 

CJ1W-CIF11

 

 

 

 

 

 

of V are connectable. Use the

 

 

 

 

 

 

 

 

NS-002to connect models without

 

 

 

 

 

 

 

a V suffix.

 

 

 

 

 

 

 

 

 

 

 

 

NS12/10

NS12-KBA04

 

 

 

 

 

 

Anti-reflectionSheets

 

NS8

NS7-KBA04

 

 

 

 

 

 

(5 surface sheets)

 

 

 

 

 

 

 

 

NS5

NT30-KBA04

 

 

 

 

 

 

 

 

 

 

 

Sheet/Cover

 

 

Protective Covers

 

NS12/10

NS12-KBA05

 

 

 

NS8

NS7-KBA05

 

 

 

 

 

 

(5 pack)

 

 

 

 

 

 

 

(anti-reflectioncoating)

 

NS5

NT31C-KBA05

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Protective Covers

 

NS12/10

NS12-KBA05N

 

 

 

 

 

 

(5 covers included)

 

NS8

NS7-KBA05N

 

 

 

 

 

 

(Transparent)

 

NS5

NT31C-KBA05N

 

 

 

 

 

 

 

 

 

 

 

 

 

(NT625C/631/631C Series to NS12/10 Series)

NS12-ATT01

 

Attachment

 

(NT625C/631/631C Series to NS12/NS10 Series) (Black)

NS12-ATT01B

 

 

 

 

 

 

(NT610C Series to NS12/10 Series)

 

NS12-ATT02

 

 

 

(NT620S/620C/600S Series to NS8 Series)

NS8-ATT01

 

 

 

(NT600M/600G/610G/612G Series to NS8 Series)

NS8-ATT02

 

Memory Card

 

 

 

 

30 MB

HMC-EF372

 

 

 

 

 

64 MB

HMC-EF672

 

 

 

 

 

 

 

 

 

 

 

Memory Card Adapter

 

HMC-AP001

 

Battery

 

 

 

 

 

CJ1W-BAT01

 

Bar Code Reader

 

V520-RH21-6

 

(Refer to the Catalog for details.)

 

 

 

 

 

 

 

 

 

 

 

 

 

: Note One screen cannot display two video inputs simultaneously.

 

Superior environmental resistance meets IP65F standards.

Flush surface construction is used for superior environmental resistance and the enclosure rating for the front of the PT is IP65F compliant.

IP International Protection

6 Dust and dirt will not enter interior. (Enclosure protects against foreign objects.)

5 There are no adverse effects from a water stream from any direction.

(Enclosure protects against water intrusion.)

F There are no harmful effects from oil droplets or spray from any direction. (Enclosure protects against oil intrusion.)

: MayNotenot be applicable in environments withlong-termexposure to water or oil.

Meets International Standards and

Exports are Not Restricted

The PTs conform to UL standards (cULus) and EC Directives.

In addition, there are no export restrictions on the PTs. cULus certification is scheduled for the near future for the NSH5 5-inchHand-heldPT.

Related Products

WS02-NSFC1-EV2Face Plate

Auto-Builderfor NS

Significantly reduces the engineering time required by combining LCB/LCU and the NS Series.

Automatic generation of control screens and tuning screens. Automatic generation of NS screen data by the software from tag information created withCX-ProcessTool.

NS communications address allocation, ladder programs, etc., are completely unnecessary.

Data that has been generated can be freely edited and processed byCX-Designer(NS screen creation software).

NS Faceplate Auto-Builderupgraded to version 2.0.Maximum number of automatically generated loops

increased from 32 to 100.

Automatic generation from theCX-Processprojects that use multiple nodes.

Automatic generation of detailed setting screens for Line Segment programs.

Specifications

CX-ProcessTool

(LCB/LCU programming software)

LCB/LCU program creation (function block method)CSV tag file output

NS Series

Created screens are easily transferred to the NS by means of a Memory Card or over the network.

SYSMAC CS1 +LCB/LCU

CSV tag file for

NS project file

LCB/LCU

 

Face Plate Auto-Builderfor NS

CX-Designer

(NS screen creation software)

Editing created data

Creation of other required screens

Product name

Specifications

Model number

Face Plate Auto-Builderfor NS

CSV tag files for LCB/LCU used in Face Plate Auto-Builderfor NS

WS02-NSFC1-EV2

22

23

Cat. No. V078-E1-09

2007.3

OMRON Corporation

Industrial Automation Company

In the interest of product improvement, specifications are subject to change without notice.

http://www.ia.omron.com/