Omron NE-C29-E User Manual

0 (0)
Compressor Nebuliser
Model
NE-C29-E
• Instruction Manual
• Mode d’emploi
• Gebrauchsanweisung
• Manuale di istruzioni
• Gebruiksaanwijzing
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
TM
3
5
EN
FR
DE
IT
ES
IM-NE-C29-E-06-11/2011
1649773-2E
NL
AR
RU
2
Before using the unit
Contents
Before using the unit
Introduction ................................................................................................... 3
Intended use.................................................................................................. 3
Important safety instructions....................................................................... 4
1. Know your unit........................................................................................ 7
2. Guide to using the Comp Air Pro .......................................................... 9
Operating instructions
3. Preparing the nebuliser for use ........................................................... 10
4. Taking medication ................................................................................ 14
Care and maintenance
5. Cleaning and daily disinfecting ........................................................... 17
5.1 Cleaning............................................................................................. 17
5.2 Disinfecting the nebulising parts ........................................................ 18
6. Maintenance and storage..................................................................... 20
7. Changing the air filter........................................................................... 21
8. Troubleshooting.................................................................................... 22
9. Technical data ....................................................................................... 23
10. Optional parts and accessories........................................................... 27
3
EN
Introduction
Thank you for purchasing the OMRON Comp Air Pro.
This product was developed in conjunction with respiratory therapists for the
successful treatment of asthma, chronic bronchitis, allergies and other respiratory
disorders. The compressor forces air to the nebuliser. When the air enters the
nebuliser, it converts the prescribed medication into an aerosol of microscopic
droplets that can easily be inhaled.
The Comp Air Pro is a medical device. Operate this device only as instructed by
your doctor and/or respiratory therapist.
Medical Purpose This product is intended to be used for inhaling medication
for respiratory disorders.
Intended User Legally certified medical experts, such as doctor, nurse and
therapist, or healthcare personnel or patient under the
guidance of qualified medical experts.
The user should also be capable of understanding general
machine operation and the content of instruction manual.
Intended Patients This product should not be used by patients, who are
unconscious or are not breathing spontaneously.
Environment This product is intended for use in a medical facility, such as
Hospital, clinic and doctor’s office, and in a room of general
household.
Durable period Durable periods are as follows, provided the product is used
to nebulise saline 10 times a day for 10 minutes each time at
room temperature (23°C).
Durable period may vary depending on usage environment.
Main unit 3 years
Nebuliser Kit
(Cap, Inhalation Air Inlet, Baffle, Medication Cup) 100 days
Mouthpiece 100 days
Air Tube 100 days
Air Filter 60 days
Child Mask 100 days
Adapter for Child Mask 100 days
Precautions for use Warnings and cautions described in the instruction manual
should be observed.
Intended use
4
Important safety instructions
Read all the information in the instruction manual and any other literature included
in the box before using the device.
When using an electrical product, especially when children are present, basic
safety precautions should always be followed including the following:
Warning:
Indicates a potentially hazardous situation which, if not avoided, could result in
serious injury.
(Usage)
For type, dose, and regime of medication follow the instructions of your doctor or
respiratory therapist.
Do not use only water in the nebuliser, for nebulising purposes.
Clean and disinfect the nebuliser kit, mouthpiece and optional nosepiece or
masks before using them for the first time after purchase, if the device has not
been used for a long period of time, or if more than one person uses the same
device.
Be sure to wash the parts after use, and ensure that they are thoroughly
disinfected and dried, and stored in a clean location.
Keep the device out of the reach of unsupervised infants and children. The
device may contain small pieces that can be swallowed.
Store the device and accessories in a clean location.
Do not store the air tube while there is moisture or medication remaining inside it.
Always rinse the nebulising parts with clean hot tap water after disinfecting them.
Never leave the cleaning solution in the medication tank or mouthpiece.
Do not use or store the device where it may be exposed to noxious fumes or
volatile substances.
Do not use the device where it may be exposed to flammable gas.
Do not block the ventilation slots. Never place the device where the ventilation
slots may be obstructed during operation. Do not cover the compressor with a
blanket or towel etc., during use.
Make sure that the nebuliser kit is clean before use.
Always dispose of any remaining medication after use, and use fresh medication
each time.
Do not use in anaesthetic or ventilator breathing circuits.
(Risk of electrical shock)
Never unplug the power cord with wet hands.
The compressor and power cord are not waterproof. Do not spill water, or other
liquids, on these parts. If liquid does spill on these parts, immediately unplug the
power cord and wipe off the liquid with gauze or other absorbent material.
EN
5
Important safety instructions
Do not immerse the main unit in water or other liquid.
Do not use or store the device in humid locations, such as a bathroom.
Do not operate the unit with a damaged cord or plug.
Keep the power cord away from heated surfaces.
Read and follow the “Important information regarding Electro Magnetic
Compatibility (EMC)” in the Technical Data Section.
Caution:
Indicates a potentially hazardous situation which if not avoided, may result in minor
or moderate injury, or physical damage.
(Usage)
Provide close supervision when this device is used by, on, or near children or
invalids.
Make sure that the parts are attached correctly.
Make sure that the vaporiser head is correctly installed before use.
Make sure that the air filter is correctly attached.
Make sure that the air filter is clean. If the air filter has changed colour, or has
been used on average for more than 60 days, replace it with a new one.
Do not spill liquid or medication on the compressor.
Do not tilt the nebuliser kit so that it is at an angle of greater than 45°, or shake it
while in use.
Do not use or store the device while the air tube is creased.
Use only original nebulising parts, air tube, air filter and filter cover.
Do not add more than 7 ml of medication to the medication tank.
Do not carry or leave the nebuliser kit while the medication tank contains
medication.
Do not leave the unit unattended with infants or persons who cannot express
their consent.
Do not subject the device or the parts to any strong shocks such as dropping the
device on the floor.
Do not distort the vaporiser head, or jab the nozzle of the medication tank with a
pin etc.
Do not insert fingers or objects inside the compressor.
Do not disassemble or attempt to repair the compressor or power cord.
Do not block the air filter cover.
When sterilising parts by boiling, make sure that the container does not boil dry.
Never place, or attempt to dry the compressor, the power cord or nebuliser in a
microwave oven.
Do not use the device while sleeping or if drowsy.
6
Important safety instructions
To avoid injury to the nose mucosa, do not squeeze the nosepiece into the back
of the nose.
Do not block the slit between the cap and the inhalation air inlet.
Do not use a microwave oven or hair dryer to dry the nebulising parts.
Approved for human use only.
(Risk of electrical shock)
Always unplug the device from the power outlet after use and before cleaning.
Plug the device into the appropriate voltage outlet. Do not overload power outlets
or use extension cords.
Do not wind the power cord around the main unit.
Changes or modifications not approved by OMRON Healthcare will void the user
warranty.
General Safety Precautions:
Inspect the device and parts before using them each time, and check that there
are no problems. In particular, be sure to check the following:
- That the vaporiser head, nozzle or air tube are not damaged.
- That the nozzle is not blocked.
- That the compressor operates normally.
When using this device, there will be some noise and vibration caused by the
pump in the compressor. There will also be some noise caused by the emission
of compressed air from the nebuliser kit. This is normal and does not indicate a
malfunction.
Operate the device only as intended. Do not use the device for any other
purpose.
Do not use the device at temperatures greater than +40°C.
Make sure that the air tube is securely attached to the compressor (main unit)
and nebuliser kit, and does not come loose. Twist the airtube plug slightly when
inserting it into the connectors to avoid the tube disconnecting during use.
The plug is provided so that the unit can be completely isolated from the power
source. To completely isolate the unit from the power source unplug the plug from
the power source.
Read and follow the “Correct Disposal of This Product” in the Technical Data
Section when disposing of the device and any used accessories or optional parts.
Save these instructions for future reference.
7
EN
1. Know your unit
A. Compressor (Main Unit)
A1.Power Switch
A2.Air Connector
A3.Filter Cover
(* Air filter inside.)
A4.Nebuliser Kit Holder
A5.Ventilation Slots
A6.Storage Compartment Cover
A7.Power Cord
A8.Power Plug
B. Air Tube (PVC, 207cm)
B1.Air Plug
B2.Air Plug
C. Nebulising Parts
D. Inhalation Attachments
D1.Mouthpiece
D2.Adult Mask (PVC)
D3.Child Mask (PVC)
D4.Nosepiece
E. Nebuliser Kit
E1.Cap
E2.Inhalation Air Inlet
E3.Inhalation Top
E4.Vaporiser Head
E5.Medication Tank
E6.Nozzle
E7.Air Tube Connector
3
5
3
5
B
A5
A4
A8
A7
E1
E3
E2
E6
E4
E5
E7
A
C
D
E
A1
A2
B1
B2
A3
A6
A5
D2 D3D1 D4
Rear View
8
1. Know your unit
Accessories
Material of attachment
Also applicable Section 10. Optional parts and accessories.
F. Spare Air Filters x 5
G. Instruction Manual
H. Warranty Card
Nebuliser Kit, Mouthpiece, Nosepiece, Adapter for
Child Mask (SEBS):
Polypropylene
Adult Mask (PVC), Child Mask (PVC): PVC
Adult Mask (SEBS), Child Mask (SEBS): SEBS
Air Tube: PVC and Polypropylene
Air Filter: Polyester
Air Filter Cover: ABS
F
G H
9
EN
2. Guide to using the Comp Air Pro
Preparing the Nebuliser for Use (Section 3)
Note: Clean and disinfect the nebuliser kit and applicable inhalation
attachments before using the device for the first time, or if it has not
been used for more than one week.
Taking Medication (Section 4)
Notes:
Do not tilt the nebuliser kit so that it is at an
angle of greater than 45
°.
Do not crease or fold the air tube.
m
a
x
5
3
m
a
x
5
3
m
a
x
5
3
m
a
x
5
3
Cleaning Parts After Use (Section 5)
Note: Failure to clean the nebulising parts
after use may lead to infection.
How the nebuliser kit works
The compressed air from the
compressor is forced through the
nozzle, as it does so, it is mixed with
the medication in the vaporiser head
and forced upwards. The medication
is then turned into a fine aerosol and
directed upwards by the baffle,
where it is broken down into many
smaller aerosol particles.
Baffle
Aerosol
Vaporiser
Head
Medication
Compressed Air
Aerosol
Medication
Nozzle
Loading...