Omron NE-C801 User Manual

4.7 (3)

INSTRUCTION MANUAL

TM

Compressor Nebulizer

NE-C801

ESPAÑOL

Caution: Federal (USA) law restricts this device to sale by or on the order of a physician or licensed healthcare practitioner

ENGLISH

CONTENTS

Before Using the Device

Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Intended Use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Safety Information. . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Know Your Unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Operating Instructions

Preparing the Nebulizer for Use. . . . . . . . . . . . . . . . . . . . . 11 Attaching the Air Tube . . . . . . . . . . . . . . . . . . . . . . . . 14 Using the Device. . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Care and Maintenance

Cleaning after Each Use . . . . . . . . . . . . . . . . . . . . . . . . 18 Daily Disinfecting. . . . . . . . . . . . . . . . . . . . . . . . . . 19 Changing the Air Filter. . . . . . . . . . . . . . . . . . . . . . . . 20 Caring for the Device . . . . . . . . . . . . . . . . . . . . . . . . . 21

Troubleshooting

Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . 22 Limited Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . 23 FCC Statement. . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Technical Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Guidance and Manufacturer's Declaration. . . . . . . . . . . . . . . . . 27

The illustrations shown in this instruction manual are image drawings and may differ slightly from the appearance of the actual product.

2

Before Using the Device

Introduction

Thank you for purchasing the OMRON NE-C801 Compressor Nebulizer.

Fill in for future reference.

DATE PURCHASED:___________________

SERIAL NUMBER:_____________________

Stapleyourpurchasereceipthere

Registeryourproducton-lineat www.register-omron.com

This product was developed for the successful treatment of asthma, allergies and other respiratory disorders. The compressor forces air to the nebulizer. When the air enters the nebulizer, it converts the prescribed medication into an aerosol of microscopic droplets that can easily be inhaled.

Your NE-C801 Compressor Nebulizer comes with the following components:

Compressor (Main Unit)

Nebulizer Kit

Mouthpiece

Air Tube (PVC, 100 cm)

AC Adapter

Air Filters (Package of 5)

Storage Bag

Instruction Manual

The following are optional accessories sold separately:

Nosepiece

Adult Mask (PVC)

Child Mask (PVC)

Please read this instruction manual thoroughly before using the unit. Please keep for future reference.

For specific information about your own nebulizer, CONSULT YOUR DOCTOR.

SAVE THESE INSTRUCTIONS

3

Intended Use

The NE-C801 Compressor Nebulizer System is intended to provide air to the pneumatic nebulizer in order to aerosolize medications for inhalation by the patient for respiratory disorders. The system is designed for use with pediatric (defined by the prescribed medication) and adult patients in the home, hospital, and sub-acute settings.

All warnings and cautions described in this manual should be observed.

4

Safety Information

To ensure the correct use of the product, basic safety measures should always be followed including the warnings and cautions listed in this instruction manual.

SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL

WARNING

Indicates a potentially hazardous situation which, if not

avoided, could result in death or serious injury.

 

 

 

CAUTION

Indicates a potentially hazardous situation which, if not

avoided, may result in minor or moderate injury to the user or

 

patient or damage to the equipment or other property.

 

 

Operating the Device

For type, dose, and regime of medication follow the instructions of your physician or licensed healthcare practitioner.

If you feel anything unusual during use, stop using the device immediately and consult your physician.

Do not cover the compressor with a blanket, towel, or any other type of cover during use. This could result in the compressor overheating or malfunctioning.

Do not use the device where the device may be exposed to flammable gas or vapors. Do not use tap or mineral water in the nebulizer for inhaling purposes.

Clean and disinfect the nebulizer kit, mouthpiece, and optional nosepiece or optional masks before using them for the first time after purchase.

If the device has not been used for a long period of time, clean and disinfect the nebulizer kit, mouthpiece, and optional nosepiece or optional masks before using them.

Pentamidine is not an approved medication for use with this device.

Always dispose of any remaining medication in the medication cup after each use. Use fresh medication each time you use the device.

Do not leave the device or its parts where it will be exposed to extreme temperatures or changes in humidity, such as leaving the device in a vehicle during warm or hot months, or where it will be exposed to direct sunlight.

Do not use or store the device where it may be exposed to noxious fumes or volatile substances.

Make sure that the nebulizer kit is clean before use.

Do not use in anaesthetic or ventilator breathing circuits.

Not suitable for use in the presence of flammable anesthetic mixture with air or oxygen or nitrous oxide.

5

Safety Information

OPERATING THE DEVICE (continued)

Do not operate where oxygen is being administered in a closed environment (such as an oxygen tent).

Provide close supervision when this device is used by, on, or near infants, children or compromised individuals.

If the device is used continuously, the service life of the device may be shortened.

Limit use to 20 minutes at a time, and allow a 40 minutes interval before using the device again.

When using the device, the main unit may become hot.

Do not touch the main unit for other than necessary operation such as turning off the power while nebulizing.

Do not insert any object into the compressor.

Make sure the air filter is clean. If the air filter has changed color or has been used on average for more than 60 days, replace it with a new one.

Make sure the nebulizer kit is correctly assembled, the air filter is properly installed, and the air tube is correctly connected to the compressor and the nebulizer kit. Air may leak from the air tube during use if not securely connected.

Inspect the compressor (main unit) and the nebulizer parts each time before using nebulizer kit. Make sure no parts are damaged, the nozzle and air tube are not blocked and the compressor operates normally.

Do not use the device if the air tube is bent.

Do not block the air filter cover.

Do not alter the baffle, the nozzle in the medication cup or any part of the nebulizer kit.

Do not add more than 7mL of medication to the medication cup.

Do not operate the device at temperatures greater than +40˚C (+104˚F).

Do not tilt the nebulizer kit so the angle of the kit is greater than 45˚. Medication may flow into the mouth.

Do not shake the nebulizer kit while using the device.

Do not subject the compressor or any of the components to strong shocks, such as dropping on the floor.

This device is approved for human use only.

Do not disassemble or attempt to repair the device or components.

Operate the device only as intended. Do not use the device for any other purpose.

6

Safety Information

OPERATING THE DEVICE (continued)

Dispose of the device, components and optional accessories according to applicable local regulations. Unlawful disposal may cause environmental pollution.

Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device do not perform the expected specification or it may damage the unit.

Changes or modification not approved by Omron Healthcare will void the user warranty.

To avoid injury to the nose mucosa, do not squeeze the optional nosepiece into the back of the nose.

To avoid the medication residue on the face. After nebulization, be sure to wipe the face after removing the optional masks.

When using this device, there will be some noise and vibration caused by the pump in the compressor. There will also be some noise caused by the emission of compressed air from the nebulizer kit. This is normal and does not indicate a malfunction.

When sterilizing parts by boiling, make sure that the container does not boil dry.

Do not use the device while sleeping or if drowsy.

Do not block the slit between the cap and the inhalation air inlet.

Risk of Electrical Shock

Do not connect the AC adapter terminal using wire or other metallic conductors.

Do not use the compressor (main unit) or AC adapter while they are wet.

Do not plug or unplug the AC adapter into the electrical outlet with wet hands.

Do not immerse the compressor (main unit) in water or other liquid.

Do not spill water or other liquids on the compressor and AC adapter. These parts are not waterproof. If liquid spills on these parts, immediately unplug the AC adapter and wipe off the liquid with gauze or other soft absorbent material.

Do not use or store the device in humid locations, such as a bathroom. Use the device within the operating temperature and humidity.

Use only the AC adapter designed by Omron for this device. Use of any other AC adapter may damage the device.

Do not operate the device with a damaged power cord or plug.

Do not use a cellular phone near the device. It may result in an operational failure.

7

Safety Information

Risk of Electrical Shock (continued)

Do not overload power outlets. Plug the AC adapter into the appropriate voltage outlet.

Do not use extension cords. Plug the AC adapter directly into the electrical outlet.

Unplug the AC adapter from the electrical outlet after using the device.

Remove the AC adapter from the device after use.

Unplug the AC adapter from the electrical outlet before cleaning the device.

Do not pull the power cord of AC adapter strongly.

Maintenance and Storage

Keep the device out of the reach of unsupervised infants and children. The device may contain small parts that can be swallowed.

Do not leave the cleaning solution in the nebulizer parts. Rinse the nebulizer parts with clean hot tap water after disinfecting.

Wash the nebulizer parts after each use. Dry the parts immediately after washing.

Do not store the air tube with moisture or medication remaining in the air tube. This could result in infection as a result of bacteria.

Store the device and the components in a clean, safe location.

Do not carry or leave the nebulizer kit with medication in the medication cup.

Do not place or attempt to dry the device, components or any of the nebulizer parts in a microwave oven.

Do not wrap the power cord around the compressor (main unit) and AC adapter.

8

Omron NE-C801 User Manual

Components and Replacement Parts

Know Your Unit

Nebulizer Kit

Compressor (Main Unit)

Nebulizer Kit Holder

Air Tube Plug

Air Tube

Connector

Air Tube Plug

Power Switch

Back View

Air Tube

(PVC, 100 cm)

NOTE: Only use the NE-C801 Nebulizer Kit with this

Air Filter Cover

Power

Nebulizer.

*Air filter inside

Connector

Nebulizer Kit

Cap

Mouthpiece

Inhalation Air Inlet

Inhalation Top

Baffle

Nozzle

Medication Cup

Air Tube Connector

9

KNOW YOUR UNIT

Components:

Air Filters

Instruction Manual

Storage Bag

Package of 5

 

 

 

 

INSTRUCTION MANUAL

 

 

 

Compressor Nebulizer

 

 

 

NE-C801

 

 

 

 

ESPAÑOL

 

 

Caution: Federal (USA) law restricts this device to sale by or on the

ENGLISH

 

 

order of a physician or licensed healthcare practitioner

 

AC Adapter

Terminal

Power Cord

Power Plug

Accessories and Replacement Parts

 

 

 

 

Model No.

AC Adapter . .

. . . . . . . . . . . . . . . . . . .

C30AC

Adult Mask (PVC). . . . . . . . . . . . . . . . . .

9920

Child Mask (PVC). . . . . . . . . . . . . . . . . .

9921

Air Filters (Package of 5) . .

. . . . . . . . . . . . .

C30FL

Air Filter Cover.

.

. . . . . . . . . . . . . . . . .

C801FC

Air Tube (PVC, 100 cm). .

. . . . . . . . . . . . . .

C801AT

Nebulizer Kit Set . .

. . . . . . . . . . . . . . . .

C801NEB

Includes Nebulizer Kit, Mouthpiece and Air Tube

 

Nosepiece. . . . . . . . . . . . . . . . . . . . . .

C911

Mouthpiece. . . .

. . . .

. . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . .

C910

10

Loading...
+ 22 hidden pages