NAIS HL2H-DC48V, HL2H-DC24V, HL2H-DC12V, HL2H-DC110V, HL2H-AC6V Datasheet

...
0 (0)
407
HL-RELAYS
15A (1C), 10 A (2C) SPACE SAVING POWER RELAY
TESTING
mm inch
27.2
1.071
35.4
1.394
20.8
.819
FEATURES
• High switching capacity in a compact size
1 Form C (15 A 125 V AC), 2 Form C (10 A 250 V AC)
• Rugged construction for tough applications
• Long life
Mechanical: Min. 10
8
operations (DC),
Min. 5 × 10
7
operations (AC)
Electrical: Min. 5 × 10
5
operations
SPECIFICATIONS
Contacts
Remarks
* Specifications will vary with foreign standards certification ratings. *
1
Measurement at same location as "Initial breakdown voltage" section
*
2
Detection current: 10 mA
*
3
Excluding contact bounce time
*
4
Half-wave pulse of sine wave: 11ms; detection time: 10 µ s
*
5
Half-wave pulse of sine wave: 6ms
*
6
Detection time: 10 µ s
*
7
Refer to 5. Conditions for operation, transpor t and storage mentioned in AMBIENT ENVIRONMENT (Page 61).
Characteristics (at 25 ° C 77 ° F, 50% Relative humidity)
Arrangement 1 Form C 2 Form C Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
50 m Ω
Contact material Silver alloy
Rating (resistive)
Nominal switching capacity
15 A 125 V AC ,
10 A 250 V AC
10 A 250 V AC
Max. switching power
AC: 2,500 VA
DC: 90 W
AC: 2,500 VA
DC: 90 W
Max. switching voltage
250 V AC
30 V DC
250 V AC
30 V DC
Max. switching current 15 A 10 A
Expected life
Mechanical (at 180 cpm) 5 × 10
7
(AC), 10
6
(DC)
Electrical (resistive)
15 A 125 V AC
5 × 10
5
10 A 250 V AC
5 × 10
5
5 ×
10
5
3 A 30 V DC 5 × 10
5
5 ×
10
5
Max. operating speed 20 cpm Initial insulation resistance*
1
Min. 100 M Ω (at 500 V DC)
Initial breakdown voltage*
2
Between contact sets 1,500 Vrms for 1 min. Between open contacts 1,000 Vrms for 1 min. Between contacts and coil 2,000 Vrms for 1 min.
Operate time (at nominal voltage)
Approx. 10 ms (DC type) Approx. 10 ms (AC type)
Release time*
3
(without diode)
(at nominal voltage)
Approx. 5 ms (DC type)
Approx. 10 ms (AC type)
Temperature rise, max. (at nominal voltage)
Max. 80 ° C
Shock resistance
Functional*
4
Min. 196 m/s
2
{20 G}
Destructive*
5
Min. 980 m/s
2
{100 G}
Vibration resistance
Functional*
6
10 to 55 Hz
at double amplitude of 1 mm
Destructive
10 to 55 Hz
at double amplitude of 2 mm
Conditions for opera­tion, transport and stor­age*
7
(Not freezing and condensing at low tem­perature)
Ambient temperature
–50 ° C to +70 ° C
–58 ° F to +158 ° F
Humidity 5 to 85% R.H.
Unit weight Approx. 35 g 1.25 oz
TYPICAL APPLICATIONS
Pow er station control equipment, refriger­ators, building control equipment, office machines, and medical equipment.
ORDERING INFORMATION
2HHLEx.
Contact arrangement
AC240V
Terminal arrangement Coil voltage
Note: Standard packing Carton: 20 pcs., Case: 200 pcs. UL/CSA approved type is standard.
1: 1 Form C 2: 2 Form C
H: Plug-in HP: PC board HTM: Top mounting L: Light emitting diode wired, plug-in PL: Light emitting diode wired, PC board
AC 6, 12, 24, 48, 120, 240 V DC 6, 12, 24, 48, 110 V
HL
408
COIL DATA (at 20 ° C 68 ° F)
DC coils
AC coils (50/60 Hz), at 60 Hz
Coil voltage,
V DC
Pick-up voltage,
V DC (max.)
Drop-out voltage,
V DC (min.)
Max. allowable
voltage, V DC
Coil resistance,
Ω ( ±
10%)
Nominal coil
current, mA
Operating power, W
Nominal Minimum
6 4.8 0.6 6.6 40 150
0.90 0.58
12 9.6 1.2 13.2 160 75 24 19.2 2.4 26.4 650 37 48 38.4 4.8 52.8 2,600 18.5
110 88.0 11.0 121.0 10,000 10 1.0 0.64
Coil voltage,
V DC
Pick-up voltage,
V AC (max.)
Drop-out voltage,
V AC (min.)
Max. allowable
voltage, V AC
Nominal coil
current, mA
Operating power, VA
Nominal Minimum
6 4.8 1.8 6.6 200
1.20 0.77
12 9.6 3.6 13.2 100 24 19.2 7.2 26.4 50
48 38.4 14.4 52.8 25 110/120 96 36 132 10.9/11.9 220/240 176.0 66 242.0 6.0/6.5
Notes:
1. The range of coil current is ± 15% for AC (60 Hz), ± 10% for DC, at 20 ° C.
2. The rela y may be used in the range of 80% to 110% of the nominal coil voltage. However, it is recommended that the rela y be used at 85% to 110% nominal voltage to take temporary voltage variations into consid­eration.
3. Each coil resistance of DC types is the measured value at a coil tem­perature of 20 ° C. Please allow a compensation of ± 0.4% resistance for each coil temperature change of ± 1 ° C.
4. All AC 240 V types are rated for double coil voltages, both AC 220 V and AC 240 V.
5. F or use with 220 or 240 V DC , connect a resistor , as suggested belo w , in series with the 110 V DC relay.
Voltage 1 Form C, 2 Form C
220 V DC 240 V DC
11 kW (5 W) 13 kW (5 W)
DIMENSIONS
mm inch
Plug-in PC board*
1
Top mounting
HL1
(1 Form C)
1.2
.047
Accepts Faston #187
Schematic
2 6
87
3
20.8
.819
27.2
1.071
6.35
.250
10
.394
3.95
.156
4.6
.181
6
.236
7.15
.281
35.4
1.394
14.2
.559
AC type DC type
8
7 ()
()
3
2
6
8
7
()
(+)
3
2
6
20.8
.819
27.2
1.071
35.4
1.394
3
3
2
2
6
6
8
7
Schematic
1.2
.047
0.5
.020
1.5
.059
5
.197
3.5
.138
1.5
.059
78
AC type DC type
8
7
()
()
3
2
6
8
7
()
(+)
3
2
6
20.6
.811
43
1.693
3
3
2
6
87
2 6
8
7
Schematic
Accepts Faston #187
Mounting dimension
2-3.2 to 3.5 dia
2
.079
1.2
.047
2-.126 to .138 dia
6.35
.250
3.6
.142
35.4
1.354
37.6
1.480
37.6
1.480
Loading...