mm inch
27.2
1.071
35.4
1.394
20.8
.819
FEATURES
• High switching capacity in a compact size
1 Form C (15 A 125 V AC), 2 Form C (10 A 250 V AC)
• Rugged construction for tough applications
• Long life
Mechanical: Min. 10
8
operations (DC),
Min. 5 × 10
7
operations (AC)
Electrical: Min. 5 × 10
5
operations
SPECIFICATIONS
Contacts
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as "Initial breakdown voltage" section
*
2
Detection current: 10 mA
*
3
Excluding contact bounce time
*
4
Half-wave pulse of sine wave: 11ms; detection time: 10 µ s
*
5
Half-wave pulse of sine wave: 6ms
*
6
Detection time: 10 µ s
*
7
Refer to 5. Conditions for operation, transpor t and storage mentioned in
AMBIENT ENVIRONMENT (Page 61).
Characteristics (at 25 ° C 77 ° F, 50% Relative humidity)
Arrangement 1 Form C 2 Form C
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
50 m Ω
Contact material Silver alloy
Rating
(resistive)
Nominal switching
capacity
15 A 125 V AC ,
10 A 250 V AC
10 A 250 V AC
Max. switching power
AC: 2,500 VA
DC: 90 W
AC: 2,500 VA
DC: 90 W
Max. switching voltage
250 V AC
30 V DC
250 V AC
30 V DC
Max. switching current 15 A 10 A
Expected
life
Mechanical (at 180 cpm) 5 × 10
7
(AC), 10
6
(DC)
Electrical
(resistive)
15 A 125 V
AC
5 × 10
5
—
10 A 250 V
AC
5 × 10
5
5 ×
10
5
3 A 30 V DC 5 × 10
5
5 ×
10
5
Max. operating speed 20 cpm
Initial insulation resistance*
1
Min. 100 M Ω (at 500 V DC)
Initial
breakdown
voltage*
2
Between contact sets 1,500 Vrms for 1 min.
Between open contacts 1,000 Vrms for 1 min.
Between contacts and coil 2,000 Vrms for 1 min.
Operate time (at nominal voltage)
Approx. 10 ms (DC type)
Approx. 10 ms (AC type)
Release time*
3
(without diode)
(at nominal voltage)
Approx. 5 ms (DC type)
Approx. 10 ms (AC type)
Temperature rise, max.
(at nominal voltage)
Max. 80 ° C
Shock resistance
Functional*
4
Min. 196 m/s
2
{20 G}
Destructive*
5
Min. 980 m/s
2
{100 G}
Vibration resistance
Functional*
6
10 to 55 Hz
at double amplitude of 1 mm
Destructive
10 to 55 Hz
at double amplitude of 2 mm
Conditions for operation, transport and storage*
7
(Not freezing and
condensing at low temperature)
Ambient
temperature
–50 ° C to +70 ° C
–58 ° F to +158 ° F
Humidity 5 to 85% R.H.
Unit weight Approx. 35 g 1.25 oz
TYPICAL
APPLICATIONS
Pow er station control equipment, refrigerators, building control equipment, office
machines, and medical equipment.
ORDERING INFORMATION
2HHLEx.
Contact arrangement
AC240V
Terminal arrangement Coil voltage
Note: Standard packing Carton: 20 pcs., Case: 200 pcs.
UL/CSA approved type is standard.
1: 1 Form C
2: 2 Form C
H: Plug-in
HP: PC board
HTM: Top mounting
L: Light emitting diode wired, plug-in
PL: Light emitting diode wired, PC board
AC 6, 12, 24, 48,
120, 240 V
DC 6, 12, 24, 48,
110 V