CSA
pending
|
|
|
|
|
FLATPACK RELAY |
NF-RELAYS |
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
30.2 |
20.0 |
|
1.189 |
||
.787 |
||
|
10.8
.425
FEATURES
1.Flatpack
2.Long seller
mm inch
SPECIFICATIONS
Contacts
Arrangement1] |
|
|
|
2 Form C, 4 Form C |
|
Initial contact resistance |
Max. |
50 mΩ |
|||
(By voltage drop 6 V DC 1 A) |
Typical |
25 mΩ |
|||
Contact material |
Movable contact |
Gold-clad silver |
|||
|
|
|
|
||
Stationary contact |
Gold-clad silver |
||||
|
|||||
|
|
|
|
||
Rating, |
Max. switching power |
60 W 100 VA |
|||
|
|
|
|
||
Max. switching voltage |
220 V AC, DC |
||||
(resistive load) |
|||||
|
|
|
|
||
Max. switching current |
2 A |
||||
|
|||||
|
|
|
|
|
|
|
Mechanical |
|
|
108 |
|
Expected life |
Electrical |
2 A 30 V DC |
2 × 105 |
||
(min. operations) |
1 A 30 V DC |
106 |
|||
(Resistive) |
|||||
|
0.5 A 30 V DC |
107 |
|||
|
|
||||
1]. MBB types available: 2MBB & 4MBB |
|
||||
(See next page for contact positions.) |
|
||||
Coil |
|
|
|
|
|
|
|
|
|
|
|
Nominal operating power, at 25°C |
2C |
Approx. 300 mW |
|||
4C |
Approx. 480 mW |
||||
|
|
|
|||
Max. operating power for continuous duty |
Approx. 1 W |
||||
at 40°C 104°F |
|||||
|
|
|
|
Remarks
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Initial breakdown voltage" section *2 Detection current: 10 mA
*3 Excluding contact bounce time
*4 Half-wave pulse of sine wave: 11ms; detection time: 10 s *5 Half-wave pulse of sine wave: 6ms
*6 Detection time: 10 s
*7 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 61).
Characteristics (at 25°C 77°F, 50% R.H. seal level)
Max. operating speed |
|
50 cps |
||
|
|
|
||
Initial insulation resistance*1 |
|
1,000 MΩ at 500 V DC |
||
Electrostatic |
Contact/Contact |
Approx. 4 pF |
||
|
|
|
||
Contact/Coil |
|
Approx. 7 pF |
||
capacitance |
|
|||
|
|
|
||
Contact/Ground |
Approx. 6 pF |
|||
|
||||
|
|
|
||
Initial |
Between open contacts |
750 Vrms |
||
|
|
|
||
Between contact sets |
1,000 Vrms |
|||
breakdown |
||||
|
|
|
||
Between live parts and ground |
1,000 Vrms |
|||
voltage*2 |
||||
|
Between contacts and coil |
1,000 Vrms |
||
|
|
|
|
|
Operate time*3 (at nominal voltage) |
Max. 15 ms (Approx. 10 ms) |
|||
Release time (without diode)*3 |
Max. 10 ms (Approx. 3 ms) |
|||
(at nominal voltage) |
|
|||
|
|
|||
Contact bounce |
|
Approx. 1.5 ms |
||
|
|
|
|
|
|
|
In de-energized |
Min. 29.4 m/s2 {3 G} |
|
|
|
(In contact direction) |
||
Shock |
Functional*4 |
condition |
Min. 98 m/s2 {10 G} |
|
|
(perpendicular to contact) |
|||
resistance |
|
|
|
|
|
In energized |
Min. 196 m/s2 {20 G} |
||
|
|
|||
|
|
condition |
||
|
|
|
||
|
|
|
|
|
|
Destructive*5 |
|
Min. 980 m/s2 {100 G} |
|
|
|
|
29.4 m/s2 {3 G}, 10 to 55 Hz |
|
|
|
In de-energized |
at double amplitude of 0.5 mm |
|
|
|
(in contact direction) |
||
|
Functional*6 |
condition |
98 m/s2 {10 G}10 to 55 Hz |
|
Vibration |
|
at double amplitude of 1.6 mm |
||
|
|
|||
|
|
(perpendicular to contact) |
||
resistance |
|
|
||
|
|
In energized |
117.6 m/s2 {12 G}10 to 55 Hz |
|
|
|
condition |
at double amplitude of 2 mm |
|
|
Destructive |
|
196 m/s2 {20 G}, 10 to 55 Hz |
|
|
|
at double amplitude of 3.3 mm |
||
|
|
|
||
Conditions for operation, |
Ambient temp. |
–40°C to + 65°C |
||
transport and storage*7 |
–40°F to +149°F |
|||
|
||||
(Not freezing and condens- |
Humidity |
5 to 85%R.H. |
||
ing at low temperature) |
||||
|
|
|||
Unit weight |
|
2C |
Approx. 14 g .49 oz |
|
|
4C |
Approx. 15.5 g .55 oz |
||
|
|
TYPICAL APPLICATIONS
NF relays are widely acceptable in applications where small size and high sensitivity are required.
Such applications include: Electronic equipment, Household applications,
Alarm systems, Office machines, Communication equipment, Measuring equipment, Remote control systems, General control circuits, Machine tools, Industrial machinery, etc.
198