NAIS NF2EB-12V, NF2EB-5V, NF4EB-24V-1, NF4EB-5V-1, NF4EB-6V-1 Datasheet

...
0 (0)
NAIS NF2EB-12V, NF2EB-5V, NF4EB-24V-1, NF4EB-5V-1, NF4EB-6V-1 Datasheet

CSA

pending

 

 

 

 

 

FLATPACK RELAY

NF-RELAYS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30.2

20.0

1.189

.787

 

10.8

.425

FEATURES

1.Flatpack

2.Long seller

mm inch

SPECIFICATIONS

Contacts

Arrangement1]

 

 

 

2 Form C, 4 Form C

Initial contact resistance

Max.

50 mΩ

(By voltage drop 6 V DC 1 A)

Typical

25 mΩ

Contact material

Movable contact

Gold-clad silver

 

 

 

 

Stationary contact

Gold-clad silver

 

 

 

 

 

Rating,

Max. switching power

60 W 100 VA

 

 

 

 

Max. switching voltage

220 V AC, DC

(resistive load)

 

 

 

 

Max. switching current

2 A

 

 

 

 

 

 

 

Mechanical

 

 

108

Expected life

Electrical

2 A 30 V DC

2 × 105

(min. operations)

1 A 30 V DC

106

(Resistive)

 

0.5 A 30 V DC

107

 

 

1]. MBB types available: 2MBB & 4MBB

 

(See next page for contact positions.)

 

Coil

 

 

 

 

 

 

 

 

 

Nominal operating power, at 25°C

2C

Approx. 300 mW

4C

Approx. 480 mW

 

 

 

Max. operating power for continuous duty

Approx. 1 W

at 40°C 104°F

 

 

 

 

Remarks

* Specifications will vary with foreign standards certification ratings.

*1 Measurement at same location as "Initial breakdown voltage" section *2 Detection current: 10 mA

*3 Excluding contact bounce time

*4 Half-wave pulse of sine wave: 11ms; detection time: 10 s *5 Half-wave pulse of sine wave: 6ms

*6 Detection time: 10 s

*7 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 61).

Characteristics (at 25°C 77°F, 50% R.H. seal level)

Max. operating speed

 

50 cps

 

 

 

Initial insulation resistance*1

 

1,000 MΩ at 500 V DC

Electrostatic

Contact/Contact

Approx. 4 pF

 

 

 

Contact/Coil

 

Approx. 7 pF

capacitance

 

 

 

 

Contact/Ground

Approx. 6 pF

 

 

 

 

Initial

Between open contacts

750 Vrms

 

 

 

Between contact sets

1,000 Vrms

breakdown

 

 

 

Between live parts and ground

1,000 Vrms

voltage*2

 

Between contacts and coil

1,000 Vrms

 

 

 

 

Operate time*3 (at nominal voltage)

Max. 15 ms (Approx. 10 ms)

Release time (without diode)*3

Max. 10 ms (Approx. 3 ms)

(at nominal voltage)

 

 

 

Contact bounce

 

Approx. 1.5 ms

 

 

 

 

 

 

In de-energized

Min. 29.4 m/s2 {3 G}

 

 

(In contact direction)

Shock

Functional*4

condition

Min. 98 m/s2 {10 G}

 

(perpendicular to contact)

resistance

 

 

 

 

In energized

Min. 196 m/s2 {20 G}

 

 

 

 

condition

 

 

 

 

 

 

 

 

Destructive*5

 

Min. 980 m/s2 {100 G}

 

 

 

29.4 m/s2 {3 G}, 10 to 55 Hz

 

 

In de-energized

at double amplitude of 0.5 mm

 

 

(in contact direction)

 

Functional*6

condition

98 m/s2 {10 G}10 to 55 Hz

Vibration

 

at double amplitude of 1.6 mm

 

 

 

 

(perpendicular to contact)

resistance

 

 

 

 

In energized

117.6 m/s2 {12 G}10 to 55 Hz

 

 

condition

at double amplitude of 2 mm

 

Destructive

 

196 m/s2 {20 G}, 10 to 55 Hz

 

 

at double amplitude of 3.3 mm

 

 

 

Conditions for operation,

Ambient temp.

–40°C to + 65°C

transport and storage*7

–40°F to +149°F

 

(Not freezing and condens-

Humidity

5 to 85%R.H.

ing at low temperature)

 

 

Unit weight

 

2C

Approx. 14 g .49 oz

 

4C

Approx. 15.5 g .55 oz

 

 