TESTING
MINIATURE RELAY
DS2YRELAYS
20 |
9.9 |
||
|
.390 |
||
|
|
|
|
|
.787 |
||
|
|
|
9.3
.366
FEATURES
|
• 2 Form C contact |
|
• High sensitivity-200 mW nominal operating power |
|
• High breakdown voltage |
|
1500 V FCC surge between open contacts |
|
• DIP-2C type matching 16 pin IC socket |
mm inch |
• Sealed construction |
SPECIFICATIONS
Contact
Arrangement |
|
2 Form C |
|||
|
|
|
|
||
Initial contact resistance, max. |
|
50 mΩ |
|||
(By voltage drop 6 V DC 1 A) |
|
||||
|
|
||||
|
|
|
|
||
Contact material |
|
Gold-clad sliver |
|||
|
|
|
|
|
|
|
|
Max. switching power |
|
60 W, 62.5 VA |
|
|
|
|
|
|
|
Rating |
Max. switching voltage |
|
220 V DC, 250 V AC |
||
(resistive) |
Max. switching current |
|
2 A |
||
|
|
|
|
|
|
|
|
Max. carrying current |
|
3 A |
|
|
|
|
|
|
|
Expected |
Mechanical |
|
1×108 |
||
life (min. |
Electrical |
1 A 30 V DC |
|
5×105 |
|
operations) |
|
|
|
||
2 A 30 V DC |
|
1×105 |
|||
|
|
||||
Coil (polarized) (at 20°C 68°F) |
|
||||
|
|
|
|
|
|
|
|
Minimum operating power |
Approx. 98 mW |
||
Single side |
|
(147 mW: 48 V) |
|||
|
|
|
|
||
stable |
|
Nominal operating power |
Approx. 200 mW |
||
|
|
(300 mW: 48 V) |
|||
|
|
|
|
|
|
|
|
Minimum set and reset power |
Approx. 88 mW |
||
2 coil |
|
(177 mW: 48 V) |
|||
|
|
|
|
||
latching |
|
Nominal set and reset power |
Approx. 180 mW |
||
|
|
(360 mW: 48 V) |
|||
|
|
|
|
|
Remarks
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Initial breakdown voltage" section *2 Detection current: 10mA
*3 Excluding contact bounce time
*4 Half-wave pulse of sine wave: 11ms, detection time: 10 s *5 Half-wave pulse of sine wave: 6ms
*6 Detection time: 10 s
*7 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 61).
Characteristics (at 20°C 68°F)
Initial insulation resistance*1 |
|
Min. 100 MΩ (at 500 V DC) |
|||
Initial |
Between open contacts |
750 Vrms |
|||
|
|
|
|
||
breakdown |
Between contact sets |
1,000 Vrms |
|||
voltage*2 |
|
|
|
|
|
Between contact and coil |
1,000 Vrms |
||||
|
|||||
|
|
|
|
|
|
FCC surge voltage |
|
1,500 V |
|||
between contacts and coil |
|
||||
|
|
||||
|
|
||||
Operate time*3 (at nominal voltage) |
Approx. 4 ms |
||||
Release time*3 (at nominal voltage) |
Approx. 3 ms |
||||
Set time*3 (latching) (at nominal voltage) |
Approx. 3 ms |
||||
Reset time*3 (latching) (at nominal voltage) |
Approx. 3 ms |
||||
|
|
|
|
Max. 65°C with nominal |
|
Temperature rise |
|
voltage across coil and at |
|||
|
|
|
|
nominal switching capacity |
|
|
|
|
|
|
|
Shock resistance |
|
Functional*4 |
Min. 490 m/s2 {50 G} |
||
|
Destructive*5 |
Min. 980 m/s2 {100 G} |
|||
|
|
|
|||
|
|
|
Functional*6 |
10 to 55 Hz |
|
|
|
|
at double amplitude of 3.3 mm |
||
Vibration resistance |
|
|
|||
|
|
|
|||
|
Destructive |
10 to 55 Hz |
|||
|
|
|
|||
|
|
|
at double amplitude of 5 mm |
||
|
|
|
|
||
|
|
|
|
||
Conditions for operation, |
|
Ambient |
–40°C to +70°C |
||
transport and storage*7 |
|
temp. |
–40°F to +158°F |
||
(Not freezing and condens- |
|
|
|
||
|
Humidity |
5 to 85% R.H. |
|||
ing at low temperature) |
|
||||
|
|
|
|||
|
|
|
|
|
|
Unit weight |
|
|
|
Approx. 4 g .14 oz |
|
|
|
|
|
|
FCC (Federal Communication Commission) requests following standard as Breakdown Voltage specification.
1500V
750V
10 s
160 s
TYPICAL APPLICATIONS |
ORDERING INFORMATION |
|
|
|
|
|
|||||||||||||
• Telecommunication equipment |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Ex DS2Y-S |
L2 |
|
|
|
DC12 V |
|
|
|
|
R |
|
|
||||||
• Office equipment |
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
• Computer peripherals |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
• Security alarm systems |
|
Operating function |
|
|
|
|
Coil voltage |
|
|
|
Polarity |
||||||||
• Medical equipment |
|
Nil: Single side stable |
|
|
DC 1.5, 3, 5, 6, |
|
|
Nil: Standard polarity |
|||||||||||
|
|
L2: 2 coil latching |
|
|
9, 12, 24, 48 V |
|
|
R: Reverse polarity |
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(Note) Standard packing: Carton: 50 pcs. Case: 500 pcs.