20 AMP POWER RELAY HG-RELAYS

 

36

 

 

 

a

1.417

 

 

 

56

 

 

 

 

 

 

 

 

 

 

 

 

2.205

 

 

 

 

 

 

a

 

 

 

HG2

34.0 1.339

 

 

 

 

 

 

HG3

50.0 1.969

 

 

mm inch

HG4

68.0 2.667

FEATURES

•Large capacity — 20 A 250 V AC resistive and 1.5 kW 3 phase 220 V AC motor loads

High contact reliability after long use

Usable with direct soldering,

quick-connect and plug-in terminals. (.250)

SPECIFICATIONS

 

 

 

 

 

 

Contacts

 

 

 

 

 

 

 

 

 

 

 

Arrangement

 

 

 

 

 

 

 

2 Form C, 3 Form C, 4 Form C

Initial contact resistance, max.

 

 

 

 

 

 

15 mΩ

(By voltage drop 6 V DC 1A)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact material

 

 

 

 

 

 

 

 

 

 

Silver alloy

Nominal switching capacity

 

 

 

 

 

20 A 250 V AC (resistive)

Expected life (min. operations)

 

 

 

 

Mechanical (at 180 cpm)

 

 

 

 

 

 

AC type: 107, DC type: 106

Life curve for AC types

 

 

 

 

 

 

 

 

 

1,000

 

Mechanical life : 107

 

4

900

 

 

 

Operating frequency:

 

 

 

180 op./min.

 

×10

800

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operations,

700

 

 

 

 

 

 

 

 

 

 

 

600

 

 

 

 

 

 

 

 

 

 

 

500

 

 

 

 

 

 

 

 

 

 

 

400

 

 

 

 

 

 

 

 

 

 

 

300

 

 

 

 

 

 

 

 

 

 

 

2002

 

125 V

AC

cos

ϕ

= 1

 

 

 

5

 

 

 

 

 

100

0

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

C

cosϕ

 

 

 

 

 

 

0

 

 

 

 

= 1

 

 

 

 

 

 

 

5

 

10

 

 

15

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Load current, A

Remarks

* Specifications will vary with foreign standards certification ratings.

*1 Measurement at same location as "Initial breakdown voltage" section *2 Detection current: 10 mA

*3 Excluding contact bounce time

*4 Half-wave pulse of sine wave: 11ms; detection time: 10 s

Characteristics (at 60 Hz, 20°C 68°F)

Maximum operating speed

 

 

20 cpm

Initial insulation resistance*1

 

 

Min. 100 MΩ at 500 V DC

Initial

 

Between open contacts

2,000 Vrms for 1 min.

breakdown

Between contacts sets

2,000 Vrms for 1 min.

voltage*2

 

Between contacts and coil

2,000 Vrms for 1 min.

 

 

Operate time*3 (approx.)

 

2 Form C type

15 ms

 

3 Form C &

 

(at nominal voltage)

 

25 ms

 

4 Form C type

 

 

 

 

 

Release time

 

 

2 Form C type

15 ms

(without diode)*3 (approx.)

 

3 Form C &

25 ms

(at nominal voltage)

 

4 Form C type

 

 

 

 

 

 

Functional*4

98 m/s2 {10 G} (except for the

Shock resistance

 

contact moving direction)

 

 

 

 

 

 

 

Destructive*5

980 m/s2 {100 G}

 

 

 

 

Functional*6

58.8 m/s2 {6 G}, 10 to 55 Hz

 

 

 

 

at 1 mm double amplitude

Vibration resistance

 

 

 

 

Destructive

117.6 m/s2 {12 G}, 10 to 55 Hz

 

 

 

 

 

 

 

 

at 2 mm double amplitude

 

 

 

 

 

 

Conditions for operation,

 

Ambient

–50°C to +40°C

transport and storage*7

 

temp.

–58°F to +104°F

(Not freezing and condensing

Humidity

5 to 85% R.H.

at low temperature)

 

 

 

 

 

 

 

 

2 Form C type

Approx. 130 g 4.59 oz

Unit weight

 

 

3 Form C type

Approx. 185 g 6.53 oz

 

 

 

 

4 Form C type

Approx. 240 g 8.47 oz

*5 Half-wave pulse of sine wave: 6ms *6 Detection time: 10 s

*7 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 61).

Electrical life with AC load

AC load

Voltage, V AC

Current, A

Expected life

(min. operations)

 

 

 

 

125

20

5×105

Resistive

15

7.5×105

 

 

20

2×105

(cos ϕ ] 1)

 

250

15

5×105

 

 

 

10

7.5×105

 

125

15

2×105

Inductive

10

5×105

 

(cos ϕ ] 0.4)

250

10

2×105

 

7.5

5×105

 

 

AC load

Voltage, V AC

Capacity, kW

Expected life

(min. operations)

 

 

 

 

Lamp

125

0.5

2×105

0.3

5×105

 

 

 

 

 

125

0.75

2×105

 

Single

0.4

5×105

 

 

Motor

phase

250

0.75

2×105

 

0.4

5×105

 

 

 

 

Three

250

1.5

2×105

 

phase

0.75

5×105

 

 

Note: In case of an electromagnet or exiting coil load (solenoid, etc.), the value of the motor or lamp load is applicable.

Electrical life with DC load

DC load

Voltage, V DC

Current, A

Expected life (min. operations)

Resistive

24

15

5×105

125

0.8

5×105

 

Inductive (L/R ] 7 ms)

24

10

5×105

125

0.4

5×105

 

Note: For DC inductive load, use of an arc extinguishing circuit is recommended.

422

HG

TYPICAL

APPLICATIONS

Industrial machinery, machine tools, food processing and packing machines, office machines, transportation equipment and amusement devices.

ORDERING INFORMATION

 

Ex. HG

2

 

 

 

AC 240 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact arrangement

 

 

 

 

 

Coil voltage

 

 

 

 

 

 

 

 

 

2: 2 Form C

 

 

 

AC 6, 12, 24, 48, 115, 220, 240 V

3: 3 Form C

 

 

 

DC 6, 12, 24, 48, 110, 200 V

4: 4 Form C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Note) Standard packing Carton: HG2 20 pcs.

Case: HG2 100 pcs.

 

HG3, HG4 10 pcs.

 

HG3, HG4 50 pcs.

UL/CSA approved type is standard.

 

 

 

 

TYPES AND COIL DATA

DC TYPES at 20°C 68°F

 

 

Nominal coil

Pick-up

Drop-out

Max.

Coil

Nominal coil

Operating

Type

Part No.

voltage,

voltage,

allowable,

resistance,

current,

voltage, V DC

power, W

 

 

V DC (max.)

V DC (min.)

V DC voltage

Ω (±10%)

mA

 

 

 

 

 

HG2-DC6V

6

4.8

0.9

6.6

26.4

230

(approx.) 1.4

 

 

 

 

 

 

 

 

 

 

HG2-DC12V

12

9.6

1.8

13.2

100

119.6

(approx.) 1.4

HG2

HG2-DC24V

24

19.2

3.6

26.4

416

57.6

(approx.) 1.4

(2 Form C)

HG2-DC48V

48

38.4

7.2

52.8

1585

30.3

(approx.) 1.4

 

HG2-DC110V

110

88

16.5

121

7650

14.4

(approx.) 1.4

 

 

 

 

 

 

 

 

 

 

HG2-DC200V

200

160

20

220

27,800

7.2

(approx.) 1.4

 

HG3-DC6V

6

4.8

0.9

6.6

22.7

264

(approx.) 1.6

 

 

 

 

 

 

 

 

 

 

HG3-DC12V

12

9.6

1.8

13.2

89.5

134

(approx.) 1.6

HG3

HG3-DC24V

24

19.2

3.6

26.4

364

66

(approx.) 1.6

(3 Form C)

HG3-DC48V

48

38.4

7.2

52.8

1450

33.1

(approx.) 1.6

 

HG3-DC110V

110

88

16.5

121

6670

16.5

(approx.) 1.6

 

HG3-DC200V

200

160

20

220

23,800

8.4

(approx.) 1.6

 

HG4-DC6V

6

4.8

0.9

6.6

18.5

325

(approx.) 2.1

 

HG4-DC12V

12

9.6

1.8

13.2

71.4

168

(approx.) 2.1

 

 

 

 

 

 

 

 

 

HG4

HG4-DC24V

24

19.2

3.6

26.4

296

81.2

(approx.) 2.1

(4 Form C)

HG4-DC48V

48

38.4

7.2

52.8

1050

45.7

(approx.) 2.1

 

 

 

 

 

 

 

 

 

 

HG4-DC110V

110

88

16.5

121

5420

20.3

(approx.) 2.1

 

HG4-DC200V

200

160

20

220

15,500

12.9

(approx.) 2.1

 

 

 

 

 

 

 

 

 

AC TYPES (50/60 Hz) at 60 HZ, 20°C 68°F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal coil

Pick-up

Drop-out

Max.

Inductance,

Nominal coil

Operating

Type

Part No.

voltage,

voltage,

voltage,

allowable,

current,

power,

H

 

 

V AC

V AC (max.)

V AC (min.)

V AC voltage

mA

VA

 

 

 

 

 

 

 

 

 

 

 

 

 

HG2-AC6V

6

4.8

1.8

6.6

0.026

600

(approx.) 3.6

 

HG2-AC12V

12

9.6

3.6

13.2

0.104

300

(approx.) 3.6

HG2

HG2-AC24V

24

19.2

7.2

26.4

0.416

150

(approx.) 3.6

HG2-AC48V

48

38.4

14.4

52.8

1.660

75

(approx.) 3.6

(2 Form C)

HG2-AC115V

115

92

34.5

126.5

9.531

31.3

(approx.) 3.6

 

 

 

 

 

 

 

 

 

 

 

HG2-AC220V

220

176

66

242

34.96

16.4

(approx.) 3.6

 

HG2-AC240V

240

192

72

264

41.68

15

(approx.) 3.6

 

 

 

 

 

 

 

 

 

 

HG3-AC6V

6

4.8

1.8

6.6

0.018

864

(approx.) 5.2

 

HG3-AC12V

12

9.6

3.6

13.2

0.073

432

(approx.) 5.2

 

 

 

 

 

 

 

 

 

HG3

HG3-AC24V

24

19.2

7.2

26.4

0.290

216

(approx.) 5.2

HG3-AC48V

48

38.4

14.4

52.8

1.163

108

(approx.) 5.2

(3 Form C)

HG3-AC115V

115

92

34.5

126.5

6.648

45.2

(approx.) 5.2

 

 

HG3-AC220V

220

176

66

242

24.26

23.6

(approx.) 5.2

 

 

 

 

 

 

 

 

 

 

HG3-AC240V

240

192

72

264

29.06

21.6

(approx.) 5.2

 

HG4-AC6V

6

4.8

1.8

6.6

0.012

1264

(approx.) 7.6

 

 

 

 

 

 

 

 

 

 

HG4-AC12V

12

9.6

3.6

13.2

0.050

632

(approx.) 7.6

HG4

HG4-AC24V

24

19.2

7.2

26.4

0.199

316

(approx.) 7.6

HG4-AC48V

48

38.4

14.4

52.8

0.795

158

(approx.) 7.6

(4 Form C)

HG4-AC115V

115

92

34.5

126.5

4.557

66.1

(approx.) 7.6

 

 

HG4-AC220V

220

176

66

242

16.89

34

(approx.) 7.6

 

HG4-AC240V

240

192

72

264

19.87

31.6

(approx.) 7.6

Notes:

1.The coil current ranges is ±15% for AC (60 Hz), ±10% for DC (20°C 68°F).

2.These relays are applicable to a range of 80% to 110% of the nominal coil voltage. However, it is recommended that the relay be used in a range of 85% to 110% of the nominal coil voltage, taking the temporary voltage variation into consideration. For AC types, when operating voltage is 70% of nominal coil voltage, "buzzing" will oc-

cur, and a large amount of current will flow, burning the coil.

3. Each coil resistance of DC types is the measured value at coil temperature of 20°C 68°F. Please compensate the coil resistance by ±0.4%, each time the coil temperature changes by ±1°C.