LF
VDE
20A Power Relay For |
LF-RELAYS |
Home appliances |
|
|
|
15.7 |
30.1 |
15.7 |
30.1 |
.618 |
.618 |
1.185 |
|
|
1.185 |
|
||
|
|
|
23.3
23.3 .917
.917
TMP type |
PCB type |
|
mm inch |
FEATURES
1. Ideal for compressor and inverter |
4. Conforms to the various safety |
loads |
standards: |
1) Compressor load: 20A 250V AC |
UL/CSA, TÜV, VDE approved |
2) Inverter load: 20A 100V AC, 10A 200V AC |
|
2. High insulation resistance
•Creepage distance and clearances between contact and coil;
Creepage Min. 9.5mm .374inch/Clearance Min. 8mm .315inch
•Surge withstand voltage: Min. 10,000V
3. "PCB" and "TMP" types available
SPECIFICATIONS
Contact
Arrangement |
|
1 Form A |
||
Initial contact resistance, max. |
100 mΩ |
|||
(By voltage drop 6 V DC 1 A) |
||||
|
|
|||
|
|
|
||
Contact material |
|
Silver alloy |
||
|
Nominal switching |
20 A 250V AC |
||
|
capacity |
|||
|
|
|
||
|
Max. switching |
6,250 V A |
||
Rating |
power |
|||
|
|
|||
(resistive load) |
Max. switching |
250V AC |
||
|
voltage |
|||
|
|
|
||
|
Max. switching |
25 A |
||
|
current |
|||
|
|
|
||
|
Mechanical |
2 |
× 106 |
|
|
(at 180 cpm) |
|||
Expected life |
|
|
||
Electrical |
|
|
||
(min. operations) |
|
|
||
(at 20 cpm) |
|
105 |
||
|
|
|||
|
(Resistive load) |
|
|
Coil
Nominal operating power |
900 mW |
Remarks
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Initial breakdown voltage" section. *2 Detection current: 10mA
*3 Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981 *4 Excluding contact bounce time.
*5 Half-wave pulse of sine wave: 11 ms; detection time: 10 µs *6 Half-wave pulse of sine wave: 6 ms
*7 Detection time: 10 µs
*8 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24).
Characteristics
Max. operating speed |
20 cpm |
|||
(at rated load) |
|
|||
|
|
|||
Initial insulation resistance*1 |
Min. 1,000 MΩ (at 500 V DC) |
|||
|
|
Between open |
1,000 Vrms for 1 min. |
|
Initial breakdown |
|
contacts |
||
|
|
|||
voltage*2 |
|
Between contacts |
5,000 Vrms for 1 min. |
|
|
|
and coil |
||
|
|
|
||
|
|
|
||
Surge voltage between contact and |
Min. 10,000 V |
|||
coil*3 |
|
|||
|
|
|||
Operate time*4 |
|
Approx. 15ms |
||
(at nominal voltage) |
||||
|
||||
|
|
|||
Release time (without diode)*4 |
Approx. 15ms |
|||
(at nominal voltage) |
|
|||
|
|
|||
|
|
|
|
|
|
|
|
Max. 45°C |
|
Temperature rise |
|
(resistance method, contact |
||
(at nominal voltage) |
|
current 20 A, rated coil |
||
|
|
|
voltage, 60°C 140°F) |
|
Shock |
|
Functional*5 |
Min. 100 m/s2{10 G} |
|
resistance |
|
Destructive*6 |
Min. 1,000 m/s2{100 G} |
|
|
|
Functional*7 |
10 to 55Hz |
|
Vibration |
|
at double amplitude of 1.5mm |
||
|
|
|||
resistance |
|
Destructive |
10 to 55Hz |
|
|
|
at double amplitude of 1.5mm |
||
|
|
|
||
Conditions for |
|
Ambient temp. |
–40°C to +60°C |
|
operation, trans- |
|
–40°F to +140°F |
||
|
|
|||
port and storage*8 |
|
|
|
|
(Not freezing and |
|
Humidity |
5 to 85% R.H. |
|
condensing at low |
|
|||
temperature) |
|
|
|
|
Unit weight |
|
Approx. 23 g .81 oz |
TYPICAL APPLICATIONS
•Air conditioner
•Refrigerators
•OA equipment
ORDERING INFORMATION
|
|
Ex. |
A |
|
LF |
|
1 |
|
|
T |
|
12 |
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Product Name |
Contact arrangement |
|
|
Terminal shape |
Coil voltage, V DC |
||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LF |
1: 1 Form A |
|
|
|
|
|
T: TMP type |
05: 5 |
12: 12 |
||||||||||
|
|
|
|
|
|
|
|
|
|
P: PCB type |
06: 6 |
18: 18 |
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
09: 9 |
24: 24 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Note: Standard packing; Carton: 50 pcs. Case 200 pcs.
UL/CSA,VDE, TÜV approved type is standard.
40