Automotive Ultra-Miniature |
JS-M RELAYS |
Power Relay |
22 |
16 |
|
.866 |
||
.630 |
||
|
16.4
.646
FEATURES
•Low pick-up voltage for high ambient use
•Sealed construction
•Ultra-miniature size with universal footprint
•Usable at high temperature: 85°C 185°F
mm inch
SPECIFICATIONS
Contact
|
|
|
Standard type |
|
High capacity |
|
|
|
|
type |
|
|
|
|
|
|
|
Arrangement |
1 Form A, 1 Form C |
||||
Contact material |
Silver alloy |
||||
Initial contact resistance, max.* |
200 mΩ |
|
100 mΩ |
||
(By voltage drop 6 V DC 1 A) |
|
||||
|
|
|
|||
Initial voltage drop |
Max. 0.2 V (at 10 A 12 V DC) |
||||
|
Nominal switching |
10 A 16 V DC |
|
15 A 16 V DC |
|
|
capacity |
(resistive) |
|
(resistive) |
|
|
Max. switching power |
160 W |
|||
Rating |
Max. switching voltage |
16 V DC |
|||
|
|
|
|
|
15 A |
|
Max. switching current |
10 A |
|
(10 A max. at |
|
|
|
|
|
|
85°C) |
Expected |
Mechanical life |
|
107 |
||
(at 180 cpm) |
|
||||
life (min. |
|
|
|
|
|
|
|
|
|
N.O.: 105 |
|
ope.) |
Electrical |
Resistive |
105 |
|
|
|
N.C.: 5×104 |
||||
|
|
|
|
|
|
* Measured after operating 5 times at the rated load |
|
|
Coil
Nominal operating power |
640 mW |
|
|
Contact rating
|
Standard type |
High capacity type |
||||
|
|
|
|
|
|
|
Load |
Form A |
Form C |
Form A |
Form C |
||
|
|
|
|
|
||
|
N.O. |
N.C. |
N.O. |
N.C. |
||
|
|
|
||||
|
|
|
|
|
|
|
Max. carry current |
15 A |
15 A |
15 A |
15 A |
15 A |
15 A |
|
|
|
|
|
|
|
Max. make current |
25 A |
25 A |
10 A |
50 A |
50 A |
15 A |
|
|
|
|
|
|
|
Max. break current |
10 A |
10 A |
10 A |
15 A |
15 A |
15 A |
|
|
|
|
|
|
|
Characteristics
Max. operating speed |
15 cps. |
||||||
(at rated load) |
|
|
|||||
|
|
|
|||||
Initial insulation resistance*1 |
Min. 100 MΩ (at 500 V DC) |
||||||
Initial |
|
Between open |
750 Vrms for 1 min. |
||||
|
contacts |
||||||
breakdown |
|
|
|||||
|
Between |
|
|||||
voltage*2 |
|
1,500 Vrms for 1 min. |
|||||
|
|
contacts and coil |
|
||||
Operate time*3 |
|
|
Approx. 10 ms |
||||
(at nominal voltage) |
|||||||
|
|||||||
Release time (without diode)*3 |
Approx. 10 ms |
||||||
(at nominal voltage) |
|||||||
|
|||||||
Shock |
|
|
Functional*4 |
Min. 98 m/s2 {10 G} |
|||
resistance |
|
|
Destructive*5 |
Min. 980 m/s2 {100 G} |
|||
|
|
|
|
Functional*6 |
Approx. 98 m/s2 {10 G}, 10 to 55 Hz |
||
Vibration |
|
|
at double amplitude of 1.6 mm |
||||
|
|
|
|
||||
resistance |
|
|
Destructive |
Approx. 117.6 m/s2 {12 G}, 10 to 55 Hz |
|||
|
|
|
|
at double amplitude of 2 mm |
|||
|
|
|
|
|
|
||
Conditions for |
|
Ambient |
–40°C to +85°C –40°F to +185°F |
||||
operation, trans- |
|
||||||
|
temp. |
||||||
port and storage*7 |
|
||||||
|
|
||||||
(Not freezing and |
|
|
|||||
condensing at low |
Humidity |
5 to 85% R.H. |
|||||
temperature) |
|
|
|
|
|
||
Unit weight |
|
|
|
|
Approx. 12 g .423 oz |
Remarks
* Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as "Intial breakdown voltage"section *2 Detection current: 10mA
*3 Excluding contact bounce time
*4 Half-wave pulse of sine wave: 11ms; detection time: 10 s *5 Half-wave pulse of sine wave: 6ms
*6 Detection time: 10 s
*7 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 61)
TYPICAL APPLICATIONS
•Automotive:
Power-window, car antenna, door lock, intermittent wiper, interior lighting, power seat, power sunroof, car stereo power antenna, etc.
ORDERING INFORMATION
|
Ex. JSM |
1a |
|
F |
|
|
|
|
12V |
|
|
|
|
4 |
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Contact arrangement |
Protective construction |
|
Coil voltage (DC) |
|
|
Contact material |
||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
1a: 1 Form A |
Nil: Sealed construction |
|
|
9, 12 V |
4: Standard type (10 A) |
|||||||||||||||
1: 1 Form C |
F: Flux-resistant type |
|
|
5: High capacity type (15 A) |
||||||||||||||||
|
|
|
|
|
|
|||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Note: Standard packing: Carton: 100 pcs. Case: 500 pcs.
360
|
|
|
|
|
|
|
|
|
|
|
|
JS-M |
|
TYPES AND COIL DATA (at 20°C 68°F) |
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Standard type (10 A) |
High capacity type (15 A) |
|
|
|
|
Nominal |
Nominal |
|
Max. |
||
Contact |
|
|
|
|
|
|
Pick-up |
Drop-out |
Coil |
|
allowable |
||
Coil |
|
|
|
|
Nominal |
operating |
|
||||||
arrange- |
voltage, |
Sealed type |
Flux-resistant |
Sealed type |
Flux-resistant |
voltage, |
voltage, |
voltage, |
resistance |
current, |
operating |
|
voltage, |
ment |
V DC |
type |
type |
V DC |
V DC |
V DC |
Ω |
mA |
power, |
|
V DC |
||
|
|
(max.) |
(min.) |
(±10%) |
mW |
|
(at 80°C |
||||||
|
|
|
|
|
|
|
(±10%) |
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
176°F ) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 Form A |
9 |
JSM1a-9V-4 |
JSM1aF-9V-4 |
JSM1a-9V-5 |
JSM1aF-9V-5 |
9 |
4.7 |
0.7 |
126 |
71.4 |
640 |
|
12 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
12 |
JSM1a-12V-4 |
JSM1aF-12V-4 |
JSM1a-12V-5 |
JSM1aF-12V-5 |
12 |
6.3 |
0.9 |
225 |
53.3 |
640 |
|
16 |
|
|
|
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 Form C |
9 |
JSM1-9V-4 |
JSM1F-9V-4 |
JSM1-9V-5 |
JSM1F-9V-5 |
9 |
4.7 |
0.7 |
126 |
71.4 |
640 |
|
12 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
12 |
JSM1-12V-4 |
JSM1F-12V-4 |
JSM1-12V-5 |
JSM1F-12V-5 |
12 |
6.3 |
0.9 |
225 |
53.3 |
640 |
|
16 |
|
|
|
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
DIMENSIONS
|
|
|
|
mm inch |
|
Schematic (Bottom view) |
PC board pattern (Copper-side view) |
||
16 |
1a |
|
1a |
4-1.3 dia. |
|
|
|
4-.051 dia. |
|
.630 |
|
|
|
|
0.4 |
|
N.O. |
|
|
.016 |
|
|
|
|
3.9 |
COIL |
COM |
|
12 |
|
|
|||
.154 |
|
|
|
.472 |
0.24
.009
|
|
0.8 |
|
0.8 |
|
|
2 |
12.2 |
|
|
.031 |
|
.031 |
|
|
||
|
|
|
|
|
|
|
.079 |
.480 |
|
|
|
|
0.4 |
|
|
|
|
|
|
|
|
.016 |
1c |
|
1c |
5-1.3 dia. |
|
|
|
|
|
|
|||
|
|
2 |
|
3 N.O. |
|
|
|
5-.051 dia. |
|
|
|
|
|
|
|
||
|
16 |
1 |
|
12 |
|
|
N.O. |
|
|
.630 |
|
.472 |
|
|
|
|
|
|
|
|
|
|
|
|
||
|
1.2 |
5 |
|
4 N.C. |
|
COIL |
COM |
12 |
|
.047 |
|
|
|
|
|
.472 |
|
|
|
|
|
|
|
|
|
|
|
2.3 |
|
|
0.4 |
|
|
|
|
Note: Terminal No. 4 is only for |
|
|
.016 |
|
|
N.C. |
|
|
1 Form C type |
.091 |
2 |
12.2 |
|
|
|
|
|
|
.480 |
|
|
|
2 |
12.2 |
||
|
|
.079 |
22 |
|
|
|
||
|
|
|
|
|
|
.079 |
.480 |
|
|
|
|
.866 |
|
|
|
|
|
|
General tolerance: ±0.3 ±.012 |
|
|
Tolerance: ±0.1 ±.004 |
REFERENCE DATA
1-(1) Electrical life test (Resistive)
Tested sample: JSM-12V-4, 3 pcs.
Condition: 10 A 16 V DC resistive load, 20 cpm Ambient temperature: 25°C 77°F
Circuit
+ |
|
|
|
Detection circuit |
|
16 V |
Contact welding: |
|
Min. 0.5 sec. |
||
DC |
||
Mis-contacting: |
||
12 V DC |
||
|
After 0.2 sec. |
|
– |
|
Change of pick-up and drop-out voltage
|
|
6 |
|
|
|
|
Max. |
|
V |
|
|
Pick-up voltage |
|
||||
5 |
|
|
|
|||||
voltage, |
|
|
|
|
Min. |
|||
4 |
|
|
|
|
||||
|
|
|
|
|
|
|
x |
|
-out |
|
|
|
|
|
|
|
|
|
|
|
Drop-out voltage |
|
x |
|||
up/drop |
3 |
|
|
|
||||
|
|
|
|
|
|
|
Max. |
|
- |
2 |
|
|
|
|
Min. |
||
Pick |
1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
10 |
|
||
|
|
|
|
|
|
|
||
|
|
|
|
|
No. of operations, ×104 |
|
|
|
|
|
|
|
|
|
|
|
Change of contact resistance
|
|
14 |
|
|
|
|
|
|
N.O. side |
|
|||
mΩ |
12 |
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
||
resistance, |
10 |
|
|
|
|
|
|
|
|
|
|
|
|
Contact |
8 |
|
|
|
|
|
|
|
|
|
|||
6 |
|
|
|
Max. |
||
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
4 |
|
|
|
x |
|
|
|
|
|
Min. |
|
|
|
|
|
|
|
|
|
|
2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
0 |
|
|
|
|
|
|
10 |
||||
|
|
|
||||
|
|
|
|
|
No. of operations, ×104 |
|
|
|
|
|
|
1-(2) Electrical life test (Power window motor load)
Tested sample: JSM1-12V-4, 4 pcs. Load: DC 14 V
(1)Max. 14.8 A (Inrush) Max. 14.2 A (Break)
(2)Max. 20.3 A (Inrush) Max. 20.0 A (Break)
(3)Max. 16.2 A (Inrush) Max. 11.6 A (Break)
Switching frequency: 3 cycle/min. (ON:OFF = 1:9 s) Ambient temperature: (1) 85°C 185°F;
(2)–40°C –40°F; (3) 35°C 95°F
Tested cycle: (1) 2 × 104 cycle (2) 2 x 104 cycle
(3)11 × 104 cycle (Total 15 × 104 cycles)
Circuit
+ |
|
|
|
Ry1 |
|
Contact welding |
|
14 V DC |
M ~ M |
detection and |
|
Mis-contacting |
|||
|
|
||
Ry2 |
|
detection circuit |
|
– |
|
|
Change of pick-up and drop-out voltage
|
10 |
|
|
|
V |
9 |
|
|
|
voltage, |
|
|
|
|
8 |
|
|
|
|
7 |
|
|
|
|
-out |
|
|
|
|
6 |
|
Pick-up voltage |
Max. |
|
-up/drop |
|
|
|
x |
5 |
|
|
Min. |
|
4 |
|
|
|
|
Pick |
|
|
|
|
3 |
|
Drop-out voltage |
Max. |
|
|
2 |
|
|
x |
|
|
|
Min. |
|
|
1 |
|
|
|
|
0 |
2 |
4 |
15 |
|
|
No. of operations, ×104
Change of contact resistance
|
100 |
|
|
|
|
90 |
|
|
N.C. side |
|
|
|
N.O. side |
|
mΩ |
|
|
|
|
80 |
|
|
|
|
resistance, |
70 |
|
|
|
60 |
|
|
|
|
50 |
|
|
|
|
Contact |
|
|
|
|
40 |
|
|
|
|
30 |
|
|
|
|
|
|
|
|
|
|
20 |
|
|
|
|
10 |
|
|
x |
|
0 |
|
|
x |
|
2 |
4 |
15 |
|
|
|
No. of operations, ×104
361