TESTING
4,000 V BREAKDOWN VOLTAGE DS RELAYS
DS-BT RELAYS
FEATURES
20.65 |
|
10.65 |
|
.419 |
|
.813 |
|
|
|
|
10.5
.413
•4,000 V breakdown voltage
•Reinforced insulation between coil and contacts •Surge voltage withstand: 1500 V FCC Parts 68
mm inch
SPECIFICATIONS
Contact
Arrangement |
2 Form C |
2 Form D |
||
|
|
|
||
Initial contact resistance, max. |
50 mΩ |
|||
(By voltage drop 6 V DC 1 A) |
||||
|
|
|||
|
|
|||
Contact material |
Gold-clad silver |
|||
|
|
|
|
|
|
Nominal switching capacity |
2 A 30 V DC |
1 A 30 V DC |
|
|
|
|
|
|
Rating |
Max. switching power |
60 W, 125 VA |
30 W, 62.5 VA |
|
|
|
|
||
(resistive |
Max. switching voltage |
220 V DC, 250 V AC |
||
load) |
|
|
|
|
Max. switching current |
2 A |
1 A |
||
|
||||
|
|
|
|
|
|
Min. switching capacity**1 |
10 µA 10 mV DC |
||
Electrical |
Mechanical (at 180 cpm) |
2×107 |
106 |
|
life (min. |
|
|
|
|
Electrical (at 20 cpm) |
2×105 |
|||
ope.) |
||||
|
|
|
||
|
|
|
|
**1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
Coil
Arrangement |
2 Form C |
|
2 Form D |
|
Nominal operating power |
360 mW |
|
540 mW |
|
Remarks |
|
|
|
|
* |
Specifications will vary with foreign standards certification ratings. |
|
||
*1 Measurement at same location as "Initial breakdown voltage" section |
||||
*2 Detection current: 10mA |
|
|
|
|
*3 Excluding contact bounce time |
|
|
|
|
*4 Half-wave pulse of sine wave: 11ms, detection time: 10 s |
|
|||
*5 |
Half-wave pulse of sine wave: 6ms |
|
|
|
*6 |
Detection time: 10 s |
|
|
|
*7 |
Refer to 5. Conditions for operation, transport and storage mentioned in |
|||
|
AMBIENT ENVIRONMENT (Page 61) |
|
|
|
Characteristics
Arrangement |
|
2 Form C |
2 Form D |
|||
|
|
|
||||
Max. operating speed |
60 cpm at rated load |
|||||
|
|
|||||
Initial insulation resistance*1 |
Min. 100 MΩ (at 500 V DC) |
|||||
Initial |
|
Between open contacts |
750 Vrms |
500 Vrms |
||
|
for 1 min. |
for 1 min. |
||||
break- |
|
|
|
|
||
|
|
|
|
|
|
|
down |
|
Between contacts and coil |
4,000 Vrms for 1 min. |
|||
voltage*2 |
|
|
|
|
|
|
|
Between contacts sets |
750 V |
500 V |
|||
|
|
|||||
|
|
|
|
|
||
FCC surge voltage between open |
1,500 V |
|||||
contacts |
|
|
|
|||
|
|
|
|
|
||
|
|
|
||||
Operate time*3 (at nominal volt- |
Approx. 3 ms |
|||||
age) |
|
|
|
|||
|
|
|
|
|
||
|
|
|
||||
Release time (without diode)*3 |
Approx. 2 ms |
|||||
(at nominal voltage) |
|
|||||
|
|
|
||||
|
|
|
||||
Temperature rise |
|
Max. 65°C |
||||
|
|
|
|
Functional*4 |
10 to 55 Hz |
|
Vibration |
|
|
at double amplitude of 3.3 mm |
|||
|
|
|
||||
resistance |
|
|
Destruction*5 |
10 to 55 Hz |
||
|
|
|
|
at double amplitude of 5 mm |
||
|
|
|
|
|
||
|
|
|
|
|
||
Shock |
|
|
Functional*6 |
Min. 294 m/s2 (30 G) |
||
resistance |
|
|
Destruction |
Min. 980 m/s2 (100 G) |
||
Conditions for oper- |
|
Ambient |
–40°C to +70°C |
–40°C to +60°C |
||
ation, transport and |
|
temp. |
–40°F to +158°F |
–40°F to +140°F |
||
storage*7 |
|
|
|
|
|
|
|
|
|
|
|
||
(Not freezing and |
|
Humidity |
5 to 85%R.H. |
|||
condensing at low |
|
|||||
|
|
|
|
|||
temperature) |
|
|
|
|
||
|
|
|
|
|
|
|
Unit weight |
|
|
|
Approx. 4.0 g 0.14 oz |
||
|
|
|
|
|
|
|
TYPICAL APPLICATIONS
Modem
Facsimile
Telecommunication equipment
ORDERING INFORMATION
DSBT |
2 |
M |
2D |
DC3V |
|
Contact |
|
Sensitivity |
MBB function |
|
Coil voltage |
arrangement |
|
|
|||
|
|
|
|
|
|
|
S: 360 mW |
Nil: BBM (Form C) |
|
||
2: 2 Form C or |
|
(2 Form C only) |
DC 1.5, 3, 5, |
||
|
2D: 2MBB |
|
|||
2 Form D |
M: 540 mW |
|
6, 9, 12, 24 V |
||
(2 Form D) |
|
||||
|
|
(2 Form D only) |
|
|
|
|
|
|
|
|
Note: Standard packing; Carton: 25 pcs. Case 1,000 pcs.