JV-N |
COMPACT FLAT POWER RELAY FOR HEATER LOADS
JV-N RELAYS
FEATURES
22 |
16 |
|
.630 |
||
.866 |
||
|
10.9
.429
• High 16 A capacity
The contacts are high capacity 16A, 125 V AC.
•Compact, flat type with low 10.9 mm
.429 inch height
Compact flat type with low surface area of 16 × 22 mm .630 × .866 inch and height of 10.9 mm .429 inch.
•High sensitivity at 200 mW
High sensitivity at 200 mW coil power consumption.
•Represses contact terminal heat
The contact terminals are larger and thicker compared to the existing JV relay. This limits the rise in temperature of the
terminals when there is a large current flowing to approx. 28°C 62°F (normal current of 16 A).
•Conforms to the various safety standards
UL/CSA, TÜV approved.
SPECIFICATIONS
Contact
Arrangement |
|
1 Form A |
||
|
|
|||
Initial contact resistance, max. |
Max. 30 mΩ |
|||
(By voltage drop 6 V DC 1 A) |
||||
|
||||
|
|
|||
Contact material |
Silver alloy |
|||
|
|
|
|
|
|
|
Nominal switching |
16 A 125 V AC, 10 A 277 V AC |
|
Rating |
|
capacity |
10 A 30 V DC, 10 A 125 V AC |
|
|
|
|
||
|
Max. switching power |
2,770 VA, 300 W |
||
(resistive |
|
|||
load) |
|
Max. switching voltage |
277 V AC, 30 V DC |
|
|
|
|
|
|
|
|
Max. switching current |
16 A (AC 125 V), 10 A (DC) |
|
|
|
|
||
Expected life (min. ope.) |
2×107 |
|||
Mechanical (at 180 cpm) |
||||
|
||||
|
|
|
|
|
Electrical at |
|
Sealed type |
|
|
|
16 A 125 V AC, 10 A 30 |
105 |
||
resistive |
|
V DC |
|
|
load (at 20 |
|
|
||
|
|
|
||
|
Flux-resistant type |
|
||
cpm) |
|
3×105 |
||
|
10 A 125 V AC |
|||
|
|
|
||
|
|
|
|
Coil
Nominal operating power
200 mW (DC 4.5 to 48 V)
600 mW (DC 100 V)
Remarks
* Specifications will vary with foreign standards certification ratings. *1 Excluding contact bounce time
*2 Excluding contact bounce time, without diode
*3 By resistive method; nominal voltage applied to the coil; contact carrying current: 16A, at 70°C 158°F
*4 Nominal voltage applied to the coil, at 60°C 140°F
*5 Half-wave pulse of sine wave: 11 ms; detection time: 10 s *6 Half-wave pulse of sine wave: 6 ms
*7 Detection time: 10 s
*8 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 61).
Characteristics
Max. operating speed |
20 cpm |
||
|
|
|
|
Operate time*1 (at nominal voltage) |
Max. 12 ms (DC 4.5 V to 48 V) |
||
Max. 8 ms (DC 100 V) |
|||
|
|
||
|
|
||
Release time*2 (at nominal voltage) |
Max. 5 ms |
||
Initial insulation resistance |
Min. 1,000 MΩ (at 500 V DC) |
||
Initial breakdown |
Between open |
1,000 Vrms for 1 min. |
|
voltage |
contacts |
||
|
|||
(Detection |
Between contacts |
2,500 Vrms for 1 min. |
|
current: 10 mA |
and coil |
||
|
|||
|
|
|
|
Surge voltage between contact and |
Min. 4,500 V |
||
coil |
|
||
|
|
||
|
|
|
|
Temperature rise |
|
Max. 45°C (DC 4.5 V to 48 V) *3 |
|
|
Max. 55°C (DC 100 V)*4 |
||
|
|
||
|
|
Ambient temperature |
|
|
|
–40 to 70°C –40 to 158°F |
|
|
|
(DC 4.5 to 48 V) |
|
Conditions in case of operation, |
–40 to 60°C –40 to 140°F |
||
(DC 100V) |
|||
transport and storage*8 |
|||
Humidity: 5 to 85 % R.H. |
|||
|
|
||
|
|
(Note freezing and condensing |
|
|
|
at low temperature) |
|
|
|
Air pressure: 86 to 106 kPa |
|
|
|
|
|
Shock resistance |
Functional |
Min. 200 m/s2{20G}*5 |
|
Destructive |
Min. 1,000 m/s2{100G}*6 |
||
|
|||
|
Functional |
10 to 55 Hz *7 |
|
Vibration |
at double amplitude of 1.6 mm |
||
|
|||
resistance |
Destructive |
10 to 55 Hz at double |
|
|
amplitude of 2 mm |
||
|
|
||
|
|
|
|
Unit weight |
|
Approx. 8g .28 oz |
|
|
|
|
TYPICAL APPLICATIONS
•AV equipment: TV's, VTR's, etc.
•OA equipment
•HA equipment
ORDERING INFORMATIONS
|
Ex. JVN |
|
1a |
|
F |
– |
4.5 V |
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Contact arrangement |
|
Protective construction |
Coil voltage (DC) |
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1a: 1 Form A |
|
Nil: Sealed type |
4.5, 6, 9, 12, |
|||||||||||
|
|
|
|
F: Flux-resistant type |
18, 24, 48, 100 V |
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
UL/CSA, TÜV approved type is standard.