NAIS JK1aPF-9V, JK1aPF-5V, JK1aPF-48V, JK1aPF-3V, JK1aPF-24V Datasheet

...
0 (0)
NAIS JK1aPF-9V, JK1aPF-5V, JK1aPF-48V, JK1aPF-3V, JK1aPF-24V Datasheet

VDE

SLIM TYPE POWER RELAY JK-RELAYS

 

 

 

FEATURES

21.4

11

 

• Compact & Slim design: 11.0 mm (length)× 21.4 mm (width) × 15.7 mm (height)

.433

 

(.433×.843×.618 inch)

.843

 

 

 

 

 

15.7

• High capacity type (8 A) available

 

.618

 

Surge resistance: Min. 8,000 V between contact and coil

High sensitivity: 200 mW nominal operating power

Sealed type available

mm inch

• VDE, TÜV, SEMKO also approved

SPECIFICATIONS

Contact

Type

 

Standard type

High capacity

 

type

 

 

 

 

Arrangement

 

1 Form A

Initial contact resistance, max.

100 mΩ

(By voltage drop 6 V DC 1 A)

 

 

Contact material

Silver alloy

 

 

Nominal switching

3 A 30 V DC

5 A 30 V DC

Rating

 

capacity

3 A 125 V AC

8 A 125 V AC

 

Max. switching power

90 W,

150 W,

(resistive

 

 

500 VA

1,250 V A

load)

 

 

 

Max. switching voltage

250 V AC, 110 V DC (0.3 A)

 

 

 

 

Max. switching current

3 A

8 A

Expected

 

Mechanical (at 180 cpm)

5×106

life (min.

 

Electrical (at 20 cpm)

105

operations)

 

(at rated load)

 

 

 

Coil

Nominal operating

Standard and high capacity type

 

200 mW

power

 

 

 

 

 

 

 

 

Remarks

 

 

 

* Specifications will vary with foreign standards certification ratings.

 

*1 Measurement at same location as "Initial breakdown voltage" section *2 Detection current: 10 mA

*3 Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981 *4 Excluding contact bounce time

*5 Half-wave pulse of sine wave: 11ms; detection time: 10µs *6 Half-wave pulse of sine wave: 6ms

*7 Detection time: 10µs

*8 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 61).

Characteristics

Max. operating speed

 

 

20 cpm

Initial insulation resistance*1

Min. 100 MΩ at 500 V DC

Initial

Between open contacts

750 Vrms for 1 min.

breakdown

Between contact and coil

2,000 Vrms for 1 min.

voltage*2

Surge voltage between contact and coil*3

Min. 8,000 V

Operate time*4 (at nominal voltage)

Approx. 4 ms

Release time*4 (at nominal voltage)

Approx. 2 ms

(without diode)

 

 

 

 

 

Temperature rise

 

 

Max. 45°C with nominal coil

 

 

voltage and at maximum

(ambient temperature: 70°C)

allowable contact current

 

 

 

 

Shock resistance

Functional*5

Min. 98 m/s2 {10 G}

Destructive*6

Min. 980 m/s2 {100 G}

 

 

 

 

Functional*7

10 to 55 Hz at double

 

 

amplitude of 1.6 mm

Vibration resistance

 

 

Destructive

10 to 55 Hz at double

 

 

 

 

amplitude of 2 mm

 

 

 

 

Conditions for operation,

 

Ambient

–40°C to +70°C

transport and storage*8

 

temp.

–40°F to +158°F

(Not freezing and condensing

Humidity

5 to 85% R.H.

at low temperature)

 

 

 

 

Unit weight

 

 

 

Approx. 7 g .25 oz

TYPICAL APPLICATIONS

Home appliances

Microwave ovens, Air conditioners

Office equipment Photocopiers, Facsimiles

Industrial machines NC machines

ORDERING INFORMATION

 

Ex. JK 1a

P

 

 

F

 

 

 

 

12 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact capacity

 

 

 

Protectiive

 

 

Coil voltage

 

 

constructiion

 

 

 

(DC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nil: Standard 3 A

 

 

Nil: Sealed type

 

3, 5, 6, 9, 12, 18,

P: High capacity

 

 

F: Flux-resis-

 

 

 

 

 

 

24, 48 V

8A

 

 

tant type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes: 1. For TV-5 rated type, add sufix “-TV”.

For detailed specifications, please consult us.

2. Standard packing: Carton: 100 pcs.; Case: 500 pcs. UL/CSA, VDE approved type is standard.

292

Loading...
+ 2 hidden pages