VDE
SLIM TYPE POWER RELAY JK-RELAYS
|
|
|
FEATURES |
21.4 |
11 |
|
• Compact & Slim design: 11.0 mm (length)× 21.4 mm (width) × 15.7 mm (height) |
.433 |
|
(.433×.843×.618 inch) |
|
.843 |
|
|
|
|
|
||
|
15.7 |
• High capacity type (8 A) available |
|
|
.618 |
|
•Surge resistance: Min. 8,000 V between contact and coil
•High sensitivity: 200 mW nominal operating power
•Sealed type available
mm inch |
• VDE, TÜV, SEMKO also approved |
SPECIFICATIONS
Contact
Type |
|
Standard type |
High capacity |
||
|
type |
||||
|
|
|
|
||
Arrangement |
|
1 Form A |
|||
Initial contact resistance, max. |
100 mΩ |
||||
(By voltage drop 6 V DC 1 A) |
|||||
|
|
||||
Contact material |
Silver alloy |
||||
|
|
Nominal switching |
3 A 30 V DC |
5 A 30 V DC |
|
Rating |
|
capacity |
3 A 125 V AC |
8 A 125 V AC |
|
|
Max. switching power |
90 W, |
150 W, |
||
(resistive |
|
||||
|
500 VA |
1,250 V A |
|||
load) |
|
|
|||
|
Max. switching voltage |
250 V AC, 110 V DC (0.3 A) |
|||
|
|
||||
|
|
Max. switching current |
3 A |
8 A |
|
Expected |
|
Mechanical (at 180 cpm) |
5×106 |
||
life (min. |
|
Electrical (at 20 cpm) |
105 |
||
operations) |
|
(at rated load) |
|||
|
|
|
Coil
Nominal operating |
Standard and high capacity type |
|
200 mW |
power |
|
||
|
|
|
|
|
|
|
|
Remarks |
|
|
|
* Specifications will vary with foreign standards certification ratings. |
|
*1 Measurement at same location as "Initial breakdown voltage" section *2 Detection current: 10 mA
*3 Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981 *4 Excluding contact bounce time
*5 Half-wave pulse of sine wave: 11ms; detection time: 10µs *6 Half-wave pulse of sine wave: 6ms
*7 Detection time: 10µs
*8 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 61).
Characteristics
Max. operating speed |
|
|
20 cpm |
||
Initial insulation resistance*1 |
Min. 100 MΩ at 500 V DC |
||||
Initial |
Between open contacts |
750 Vrms for 1 min. |
|||
breakdown |
Between contact and coil |
2,000 Vrms for 1 min. |
|||
voltage*2 |
|||||
Surge voltage between contact and coil*3 |
Min. 8,000 V |
||||
Operate time*4 (at nominal voltage) |
Approx. 4 ms |
||||
Release time*4 (at nominal voltage) |
Approx. 2 ms |
||||
(without diode) |
|
|
|||
|
|
|
|||
Temperature rise |
|
|
Max. 45°C with nominal coil |
||
|
|
voltage and at maximum |
|||
(ambient temperature: 70°C) |
|||||
allowable contact current |
|||||
|
|
|
|
||
Shock resistance |
Functional*5 |
Min. 98 m/s2 {10 G} |
|||
Destructive*6 |
Min. 980 m/s2 {100 G} |
||||
|
|
||||
|
|
Functional*7 |
10 to 55 Hz at double |
||
|
|
amplitude of 1.6 mm |
|||
Vibration resistance |
|
|
|||
Destructive |
10 to 55 Hz at double |
||||
|
|
||||
|
|
amplitude of 2 mm |
|||
|
|
|
|
||
Conditions for operation, |
|
Ambient |
–40°C to +70°C |
||
transport and storage*8 |
|
temp. |
–40°F to +158°F |
||
(Not freezing and condensing |
Humidity |
5 to 85% R.H. |
|||
at low temperature) |
|
||||
|
|
|
|||
Unit weight |
|
|
|
Approx. 7 g .25 oz |
TYPICAL APPLICATIONS
•Home appliances
Microwave ovens, Air conditioners
•Office equipment Photocopiers, Facsimiles
•Industrial machines NC machines
ORDERING INFORMATION
|
Ex. JK 1a |
P |
|
|
F |
|
|
|
|
12 V |
|
||||
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Contact capacity |
|
|
|
Protectiive |
|
|
Coil voltage |
||||||||
|
|
constructiion |
|
|
|
(DC) |
|||||||||
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
Nil: Standard 3 A |
|
|
Nil: Sealed type |
|
3, 5, 6, 9, 12, 18, |
||||||||||
P: High capacity |
|
|
F: Flux-resis- |
|
|||||||||||
|
|
|
|
|
24, 48 V |
||||||||||
8A |
|
|
tant type |
|
|
|
|||||||||
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Notes: 1. For TV-5 rated type, add sufix “-TV”.
For detailed specifications, please consult us.
2. Standard packing: Carton: 100 pcs.; Case: 500 pcs. UL/CSA, VDE approved type is standard.