VDE |
30 AMP POWER RELAY WITH |
JH RELAYS |
SPACE SAVING DESIGN |
56 |
33 |
2.205 |
1.299 |
35.8
1.409
mm inch
FEATURES
•Many safety-oriented characteristics incorporated
Contact gap: more than 3 mm .118 inch for 1 Form A and 2 Form A
Breakdown voltage for N.O. contact: 2,000 V AC between contacts
5,000 V AC between coil and contact Molded materials: all 94 V-0
•Various contact arrangements
1 Form A, 2 Form A, 3 Form A,
2 Form A 1 Form B
•High dielectric strength for transient protection
10,000 V surge is ms between coil and contact
•High inrush resistance
1 Form A type: 117 A (meets TV-8 requirement) 2 Form A type: 91 A (meets TV-6 requirement)
VDE, TÜV also approved
SPECIFICATIONS
Contact
Arrangement |
|
1 Form A |
2 Form A |
3 Form A |
2 Form A 1 Form B |
|
|
|
|
|
|
||
Initial contact pressure |
Approx. 80 g (2.82 oz) |
Approx. 40 g (1.41 oz) |
Approx. 30 g (1.06 oz) |
N.O.: 30 g (1.06 oz); N.C.: 20 g (0.71 oz) |
||
|
|
|
|
|
||
Initial contact resistance, max. |
|
|
100 mΩ |
|
||
(By voltage drop 6 V DC 1 A) |
|
|
|
|||
|
|
|
|
|||
|
|
|
|
|
||
Contact material |
|
|
Silver alloy |
|
||
|
|
|
|
|
|
|
Rating |
Nominal switching rating |
30 A 250 V AC |
20 A 250 V AC |
15 A 250 V AC |
N.O.: 15 A 250 V AC; N.C.: 5 A 250 V AC |
|
|
|
|
|
|
||
Max. switching power |
7,500 VA |
5,000 VA |
3,750 VA |
N.O.: 3,750 VA; N.C.: 1,250 VA |
||
(resistive |
||||||
|
|
|
|
|
||
Max. switching voltage |
|
|
250 V AC |
|
||
load) |
|
|
|
|||
|
|
|
|
|
||
|
Max. switching current |
30 A |
20 A |
15 A |
N.O.: 15 A; N.C.: 5 A |
|
|
|
|
|
|
|
|
Expected |
Mechanical (at 180 cpm) |
|
5×106 (106 for latching and AC types) |
|||
Electrical |
|
|
|
|
||
life (min. |
|
|
|
|
||
(at nominal resistive load) |
|
|
105 |
|
||
operations) |
|
|
|
|||
(at 20 cpm) |
|
|
|
|
||
|
|
|
|
|
Coil
Minimum operating power |
1.23 W (DC) |
Nominal operating power |
1.92 W (DC) |
Characteristics
Contact arrangement |
|
1 Form A |
2 Form A |
|
3 Form A |
|
2 Form A 1 Form B |
|||
|
|
|
|
|
|
|
|
|
||
Maximum operating speed |
|
|
|
|
20 cpm |
|
|
|
||
|
|
|
|
|
|
|
|
|||
Initial insulation resistance*1 |
|
|
|
Min. 100 mΩ at 500 V DC |
|
|
|
|||
Initial |
Between open contacts |
|
2,000 Vrms |
|
|
|
N.O.: 2,000 Vrms; N.C.: 1,500 Vrms |
|||
|
|
|
|
|
|
|
|
|
|
|
breakdown |
Between contact sets |
— |
4,000 Vrms |
|
3,000 Vrms |
|
2,000 Vrms |
|
||
voltage |
|
|
|
|
|
|
|
|
|
|
Between contacts and coil |
|
5,000 Vrms |
|
|
|
N.O.: 5,000 Vrms; N.C.: 3,000 Vrms |
||||
|
|
|
|
|
||||||
Surge voltage*2 |
|
|
More than 10,000 V between contacts and coil |
|
||||||
Temperature rise (at nominal voltage) |
|
|
DC: Max. 65°C; AC: Max. 85°C |
|
||||||
Operate time*3 |
|
|
Approx. 20 ms at nominal voltage (DC) |
|
||||||
Release time (without diode)*3 |
|
Approx. 5 ms at nominal voltage (DC) |
|
|||||||
Shock resistance |
|
Functional: min. 98 m/s2 {10 G}; Destructive: min. 980 m/s2 {100 G} |
|
Functional: Approx. 49 m/s2 {5 G} |
||||||
|
|
Destructive: min. 980 m/s2 {100 G} |
||||||||
|
|
|
|
|
|
|
|
|
||
Vibration resistance |
|
Functional: 10 to 55Hz at 1 mm double amplitude Destructive: 10 to 55 Hz at 1.5 mm double amplitude |
||||||||
Conditions for operation, |
|
Ambient temp. |
|
–50°C to +55°C (–58°F to +131°F) |
|
|||||
transport and storage*4 |
|
Humidity |
|
|
|
5 to 85% R.H. |
|
|
|
|
(Not freezing and condens- |
|
|
|
|
|
|
|
|||
|
Air pressure |
|
|
|
86 to 106 kPa |
|
|
|
||
ing at low temperature) |
|
|
|
|
|
|
|
|||
Molded materials used |
|
|
|
|
94 V-0 |
|
|
|
||
Unit weight |
|
|
|
Approx. 90 g 3.17 oz |
Approx. 96 g 3.39 oz |
|
Approx. 100 g 3.53 oz |
|
||
|
|
|
(Approx. 115 g 4.06 oz) |
(Approx. 129 g 4.55 oz) |
|
(Approx. 130 g 4.59 oz) |
( ): screw type |
|||
|
|
|
|
|
Remarks
* Specifications will vary with foreign standards certification ratings. *1 Measurement of same location as "Initial breakdown voltage" section
*2 Wave is standard shock voltage of ±1.2 × 50 µs according to JEC-212-1981
*3 Excluding contact bounce time
*4 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24).
116
JH
TYPICAL APPLICATIONS
Air conditioners, microwave ovens, load management equipment, copiers, process control equipment.
ORDERING INFORMATION
|
|
Ex. JH |
|
2a |
|
|
|
|
|
|
|
|
|
|
L2 |
|
|
|
|
DC24V |
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Contact arrangement |
|
|
Terminals |
|
|
|
|
|
|
|
Operating function |
|
|
|
|
|
|
|
Coil voltage |
|||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||
1a: 1 Form A |
|
|
Nil: Plug-in |
|
|
|
|
|
|
Nil: Single side stable for 3 Form A, |
|
|
|
DC 6, 12, 24, 48, 110 V |
||||||||||||||||||||||
|
|
|
|
|
|
|
|
W: 2 Form A 1 Form B |
|
|
|
|
|
|
|
|
|
|||||||||||||||||||
2a: 2 Form A |
|
|
|
terminal type |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||
|
|
|
|
L2: 2 coil latching for 1 Form A, 2 Form A |
|
|
|
|
|
|
|
|
||||||||||||||||||||||||
3a: 3 Form A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
WL2: 2 coil latching for 3 Form A, |
|
|
|
|
|
|
|
|
||||||||||||||||
2a1b: 2 Form A 1 Form B |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
2 Form A 1 From B |
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||
(Notes) 1. For UL/CSA recognized type, please add suffix UL/CSA. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||
2. Standard Packing: Carton 20 pcs, Case 100 pcs. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
TYPES AND COIL DATA |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
Single side stable (DC coils at 20°C 68°F): DC types of JH3a-W and JH2a1b-W |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
Nominal voltage, |
Pick-up voltage |
|
Drop-out voltage |
|
|
Maximum allowable |
|
|
Coil resistance (ohm) |
|
Nominal operating |
|||||||||||||||||||||||||
V DC |
|
|
|
voltage, at 50°C |
|
|
|
|
power, (W) |
|||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||
6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
18.7 |
|
|
|
1.92 |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
12 |
|
Less than 80% of |
|
More than 10% of |
|
|
|
|
110% of |
|
|
|
|
|
|
75 |
|
|
|
1.92 |
||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||
24 |
|
|
|
|
|
|
|
|
|
|
|
|
300 |
|
|
|
1.92 |
|||||||||||||||||||
|
nominal voltage |
|
nominal voltage |
|
|
nominal voltage |
|
|
|
|
|
|
||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||
48 |
|
|
|
|
|
|
|
1,200 |
|
|
|
1.92 |
||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
110 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6,300 |
|
|
|
1.92 |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||
2 coil latching (DC coils only at 20°C 68°F): DC types of JH1a-L2, JH2a-L2 and JH3a-WL2 |
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||
Nominal voltage, |
Set and reset voltage |
|
Maximum allowable |
|
|
|
|
Coil resistance, (Ω) |
|
|
Nominal operating power, (W) |
|||||||||||||||||||||||||
V DC |
|
voltage, at 50°C |
|
|
|
|
Coil I |
|
|
|
|
Coil II |
|
|
|
Coil I |
|
|
Coil II |
|||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||
6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
18.7 |
|
|
|
|
|
|
18.7 |
|
|
1.92 |
|
|
1.92 |
||||||
12 |
|
Less than 80% of |
|
|
110% of |
|
|
|
75 |
|
|
|
|
|
|
75 |
|
|
1.92 |
|
|
1.92 |
||||||||||||||
24 |
|
|
|
|
|
|
300 |
|
|
|
|
|
|
300 |
|
|
1.92 |
|
|
1.92 |
||||||||||||||||
|
nominal voltage |
|
nominal voltage |
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||
48 |
|
|
|
1,200 |
|
|
|
|
|
|
1,200 |
|
|
1.92 |
|
|
1.92 |
|||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||
110 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6,300 |
|
|
|
|
|
|
6,300 |
|
|
1.92 |
|
|
1.92 |
Notes:
1.Coil resistance varies ±10% for less than 1,000 W, and ±15% for more than 1,000 Ω. For each ±1°C change in ambi-
ent temperature, coil resistance varies
±0.4%.
2.For each ±1°C change in ambient tem-
perature, pick-up and drop-out voltages vary approximately ±0.4%.
3.Pick-up and drop-out voltages are measured with the relay mounted as follows.
4. The coil operating current should be pure direct current in principle. When rectified alternating current is applied to the coil, the relay characteristics (pick-up, drop-out voltage) may be changed due to the ripple factor. Confirmation of the characteristics in the actual circuit is suggested.
117