VDE |
TV-15, 30 AMP (1 Form A) |
HE RELAYS |
Power Relay |
50 |
|
1.969 |
33 |
|
1.299 |
35.8
1.409
mm inch
FEATURES
• High contact capacity with superior inrush current characteristics;
|
1 Form A |
2 Form A |
Rating |
30 A 277 V AC |
25 A 277 V AC |
TV rating |
TV-15 |
TV-10 |
|
|
|
• Excellent high heat-resistance;
• High dielectric strength: 10,000 V surge Conforming to VDE0806 (Insulation gap: 8 mm .315 inch) VDE, TÜV also approved
SPECIFICATIONS
Contacts
Type |
|
|
|
DC coil type |
|
AC coil type |
||||||
|
|
|
|
|
|
|
|
|
|
|
||
Arrangement |
|
|
|
1a |
|
|
2a |
|
1a |
|
2a |
|
|
|
|
|
|
|
|
|
|
|
|||
Contact material |
|
|
|
|
Silver alloy |
|
||||||
|
|
|
|
|
|
|
|
|
|
|||
Initial contact resistance, max. |
|
|
|
100 mΩ |
|
|||||||
(By voltage drop 6 V DC 1A) |
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Nominal |
|
30 A |
|
|
25 A |
|
30 A |
|
25 A |
|
|
|
|
277 V |
|
|
277 V |
|
277 V |
|
277 V |
||
|
|
switching capacity |
|
|
|
|
||||||
|
|
AC |
|
|
AC |
|
AC |
|
AC |
|||
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Rating |
|
Max. switching |
|
8,310 |
|
|
6,925 |
|
8,310 |
|
6,925 |
|
|
power |
|
VA |
|
|
VA |
|
VA |
|
VA |
||
(resistive) |
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Max. switching |
|
|
277 V AC, 30 V DC |
|
|||||||
|
|
|
|
|
||||||||
|
|
voltage |
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Max. switching |
|
30 A |
|
|
25 A |
|
30 A |
|
25 A |
|
|
|
current |
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
Expected |
|
Mechanical |
|
107 |
|
|
5×106 |
|||||
|
(at 180 cpm) |
|
|
|
||||||||
life (min. |
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Electrical |
|
105 (1a: 30 A 277 V AC, 2a: 25 A 277 V AC) |
|||||||||
operations) |
|
|
||||||||||
|
(at 20 cpm) |
|
2×105 (1a: 30 A 250 V AC, 2a: 20 A 250 V AC) |
|||||||||
|
|
|
||||||||||
Coil (at 20°C 68°F) |
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
DC coil type |
|
|
AC coil type |
|
||||
|
|
|
|
|
||||||||
Nominal operating power |
|
1.92 W |
|
See Coil data (next page) |
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Remarks
* Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as "initial breakdown voltage" section *2 Detection current: 10 mA
*3 Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981 *4 Excluding contact bounce time
*5 Half-wave pulse of sine wave: 11ms; detection time: 10µs *6 Half-wave pulse of sine wave: 6ms
*7 Detection time: 10µs
*8 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24).
Characteristics
|
|
|
|
DC coil type |
AC coil type |
|
|
|
|
||||
Maximum operating speed |
20 cpm |
|||||
|
|
|||||
Initial insulation resistance*1 |
Min. 1,000 MΩ at 500 V DC |
|||||
|
|
Between open contacts |
2,000 Vrms for 1 min. |
|||
|
|
|
|
|
||
Initial |
|
Between contacts and |
5,000 Vrms for 1 min. |
|||
breakdown |
|
coil |
|
|||
|
|
|
|
|||
voltage*2 |
|
|
|
|
|
|
|
Between contact sets |
4,000 Vrms for 1 min. |
||||
|
|
|||||
|
|
(2a) |
|
|||
|
|
|
|
|
||
|
|
|
|
|
||
Surge voltage between coil |
Min. 10,000 V |
|||||
and contact*3 |
|
|
||||
|
|
|
|
|||
Operate time*4 |
|
Approx. 20 ms |
||||
(at nominal voltage) |
|
|||||
|
|
|
||||
|
|
|
|
|||
Release time*4 |
|
Approx. 5 ms |
Approx. 20 ms |
|||
(at nominal voltage) |
|
|||||
|
|
|
||||
|
|
|
|
|||
Temperature rise, max. |
|
60°C |
65°C |
|||
(resistive load)(at 55°C) |
|
|||||
|
|
|
||||
Shock resistance |
Functional*5 |
98 m/s2 {10 G} |
||||
Destructive*6 |
980 m/s2 {100 G} |
|||||
|
|
|
||||
|
|
|
Functional*7 |
10 to 55 Hz |
||
|
|
|
at double amplitude of 1 mm |
|||
Vibration resistance |
|
|||||
|
|
|
||||
Destructive |
10 to 55 Hz |
|||||
|
|
|
||||
|
|
|
at double amplitude of 1.5 mm |
|||
|
|
|
|
|||
|
|
|
||||
Conditions for opera- |
Ambient |
–50°C to +55°C |
||||
tion, transport and |
temp. |
–58°F to +131°F |
||||
storage*8 (Not freezing |
|
|
||||
Humidity |
5 to 85% R.H. |
|||||
and condensing at low |
|
|
|
|||
Air pressure |
86 to 106 kPa |
|||||
temperature) |
|
|||||
|
|
|
|
|
|
|
Unit weight |
|
|
Approx. 90 g 3.17 oz |
|||
|
|
(Plug-in type) |
||||
|
|
|
|
|||
|
|
|
|
|
|
TYPICAL |
ORDERING INFORMATION |
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||
APPLICATIONS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
HE |
1a |
|
|
|
N |
|
|
|
S |
|
|
|
|
|
DC12 |
|
V |
||||||||
1. Home appliances |
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
• Air conditioners |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
• Microwave ovens |
Contact arrangement |
|
Pick-up voltage |
|
|
|
|
|
Terminals |
|
Coil voltage |
|||||||||||||||
• TV sets |
1a: 1 Form A |
|
N: 70% of nominal |
|
Nil: Plug-in terminal type |
|
DC: 6, 12, 24, 48, |
|||||||||||||||||||
• Heaters |
2a: 2 Form A |
|
|
voltage |
|
|
|
|
|
S: Screw terminal type |
|
110 V |
||||||||||||||
• Stereo |
|
|
|
|
|
|
|
|
|
|
|
|
|
SW: Screw terminal type |
|
AC: 12, 24, 48, |
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(wide pitch) |
|
120, 240 V |
|||||||||
2. Office equipment |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Q: NEMA terminal type |
|
|
|
||||||||||
• Copiers |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
P: PC board terminal type* |
|
|
|||||||||||
• Vending machines |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Standard packing: Carton: 20 pcs.; Case: 100 pcs. |
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||
|
* PC board terminal are available only for 1 Form A type of DC coil voltage. |
|
|
|
||||||||||||||||||||||
|
UL/CSA, TÜV approved type is standard. |
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
110 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
HE
TYPES
|
Terminal shape |
Contact arrangement |
||
|
|
|
||
|
1 Form A |
2 Form A |
||
|
|
|||
|
|
|
|
|
|
|
HE1aN-DC6V |
HE2aN-DC6V |
|
|
|
|
|
|
|
|
HE1aN-DC12V |
HE2aN-DC12V |
|
|
|
|
|
|
|
Plug-in terminal |
HE1aN-DC24V |
HE2aN-DC24V |
|
|
|
|
|
|
|
|
HE1aN-DC48V |
HE2aN-DC48V |
|
|
|
|
|
|
|
|
HE1aN-DC110V |
HE2aN-DC110V |
|
|
|
|
|
|
|
|
HE1aN-S-DC6V |
HE2aN-S-DC6V |
|
|
|
|
|
|
|
|
HE1aN-S-DC12V |
HE2aN-S-DC12V |
|
|
|
|
|
|
|
Screw terminal |
HE1aN-S-DC24V |
HE2aN-S-DC24V |
|
|
|
|
|
|
|
|
HE1aN-S-DC48V |
HE2aN-S-DC48V |
|
|
|
|
|
|
|
|
HE1aN-S-DC110V |
HE2aN-S-DC110V |
|
|
|
|
|
|
|
|
HE1aN-SW-DC6V |
HE2aN-SW-DC6V |
|
|
|
|
|
|
DC |
Screw terminal |
HE1aN-SW-DC12V |
HE2aN-SW-DC12V |
|
|
|
|||
HE1aN-SW-DC24V |
HE2aN-SW-DC24V |
|||
type |
(wide pitch) |
|||
|
|
|||
HE1aN-SW-DC48V |
HE2aN-SW-DC48V |
|||
|
|
|||
|
|
|
|
|
|
|
HE1aN-SW-DC110V |
HE2aN-SW-DC110V |
|
|
|
|
|
|
|
|
HE1aN-Q-DC6V |
HE2aN-Q-DC6V |
|
|
|
|
|
|
|
|
HE1aN-Q-DC12V |
HE2aN-Q-DC12V |
|
|
|
|
|
|
|
NEMA terminal |
HE1aN-Q-DC24V |
HE2aN-Q-DC24V |
|
|
|
|
|
|
|
|
HE1aN-Q-DC48V |
HE2aN-Q-DC48V |
|
|
|
|
|
|
|
|
HE1aN-Q-DC110V |
HE2aN-Q-DC110V |
|
|
|
|
|
|
|
|
HE1aN-P-DC6V |
— |
|
|
|
|
|
|
|
PC board |
HE1aN-P-DC12V |
— |
|
|
|
|
||
|
HE1aN-P-DC24V |
— |
||
|
terminal |
|||
|
|
|
||
|
HE1aN-P-DC48V |
— |
||
|
|
|||
|
|
|
|
|
|
|
HE1aN-P-DC110V |
— |
|
|
|
|
|
|
Terminal shape |
Contact arrangement |
|
|
|
|
|
|
1 Form A |
2 Form A |
|
|
|
||
|
|
|
|
|
|
HE1aN-AC12V |
HE2aN-AC12V |
|
|
|
|
|
|
HE1aN-AC24V |
HE2aN-AC24V |
|
|
|
|
|
Plug-in terminal |
HE1aN-AC48V |
HE2aN-AC48V |
|
|
|
|
|
|
HE1aN-AC120V |
HE2aN-AC120V |
|
|
|
|
|
|
HE1aN-AC240V |
HE2aN-AC240V |
|
|
|
|
|
|
HE1aN-S-AC12V |
HE2aN-S-AC12V |
|
|
|
|
|
|
HE1aN-S-AC24V |
HE2aN-S-AC24V |
|
|
|
|
|
Screw terminal |
HE1aN-S-AC48V |
HE2aN-S-AC48V |
|
|
|
|
|
|
HE1aN-S-AC120V |
HE2aN-S-AC120V |
|
|
|
|
AC |
|
HE1aN-S-AC240V |
HE2aN-S-AC240V |
type |
|
HE1aN-SW-AC12V |
HE2aN-SW-AC12V |
|
|
|
|
|
Screw terminal |
HE1aN-SW-AC24V |
HE2aN-SW-AC24V |
|
|
|
|
|
HE1aN-SW-AC48V |
HE2aN-SW-AC48V |
|
|
(wide pitch) |
||
|
|
|
|
|
HE1aN-SW-AC120V |
HE2aN-SW-AC120V |
|
|
|
||
|
|
|
|
|
|
HE1aN-SW-AC240V |
HE2aN-SW-AC240V |
|
|
|
|
|
|
HE1aN-Q-AC12V |
HE2aN-Q-AC12V |
|
|
|
|
|
|
HE1aN-Q-AC24V |
HE2aN-Q-AC24V |
|
|
|
|
|
NEMA terminal |
HE1aN-Q-AC48V |
HE2aN-Q-AC48V |
|
|
|
|
|
|
HE1aN-Q-AC120V |
HE2aN-Q-AC120V |
|
|
|
|
|
|
HE1aN-Q-AC240V |
HE2aN-Q-AC240V |
|
|
|
|
COIL DATA at 20°C 68°F
|
|
|
Drop-out |
Nominal coil |
|
Nominal |
Max. allowable |
|
|
Pick-up voltage, |
Coil resistance, |
voltage |
|||
|
Nominal voltage |
voltage, |
current, |
operating power, |
|||
|
V DC (max.) |
Ω (±10%) |
(at 50°C 122°F), |
||||
|
|
V DC (min.) |
mA (±10%) |
W |
|||
|
|
|
|
V DC |
|||
|
|
|
|
|
|
|
|
|
6 V DC |
4.2 |
0.6 |
320.9 |
18.8 |
1.92 |
6.6 |
|
12 V DC |
8.4 |
1.2 |
160 |
75 |
1.92 |
13.2 |
DC coil type |
24 V DC |
16.8 |
2.4 |
80 |
300 |
1.92 |
26.4 |
|
48 V DC |
33.6 |
4.8 |
40 |
1200 |
1.92 |
52.8 |
|
110 V DC |
77.0 |
11.0 |
17.5 |
6300 |
1.92 |
121.0 |
|
|
|
|
|
|
|
|
|
|
|
Drop-out |
Nominal coil |
|
Nominal |
Max. allowable |
|
|
Pick-up voltage, |
Coil resistance, |
voltage |
|||
|
Nominal voltage |
voltage, |
current, |
operating power, |
|||
|
V AC (max.) |
Ω (±10%) |
(at 50°C 122°F), |
||||
|
|
V AC (min.) |
mA (±10%) |
VA |
|||
|
|
|
|
V AC |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
12 V AC |
8.4 |
1.8 |
138* |
75 |
1.7 |
13.2 |
|
|
|
|
|
|
|
|
|
24 V AC |
16.8 |
3.6 |
74* |
300 |
1.8 |
26.4 |
|
|
|
|
|
|
|
|
AC coil type |
48 V AC |
33.6 |
7.2 |
39* |
1200 |
1.9 |
52.8 |
|
|
|
|
|
|
|
|
|
120 V AC |
70.0 |
18.0 |
22.1* |
5200 |
2.7 |
132.0 |
|
|
|
|
|
|
|
|
|
240 V AC |
140.0 |
36.0 |
10.8* |
20800 |
2.6 |
264.0 |
|
|
|
|
|
|
|
|
*Value at 60 Hz