NAIS HX2-24V, HX2-3V, HX2-4.5V, HX2-5V, HX2-6V Datasheet

...
4 (1)
NAIS HX2-24V, HX2-3V, HX2-4.5V, HX2-5V, HX2-6V Datasheet

Compact & Slim 2 Form C

HX-RELAYS

Non-polarized Relay

15.0

7.4

.291

.591

 

9.4

.370

mm inch

FEATURES

Compact size of (W) 7.4× (L) 15.0 × (H) 9.4 mm (W) .291× (L) .591× (H) .370 inch.

Surge withstand voltage of 1,500 V (between contact and coil)

Conforms to FCC Part 68.

High-density mounting is possible

High reliability

The use of a gold-clad bifurcated structure for the movable contacts, and a low gas material for the forming materials and coil wiring ensures high contact reliability.

SPECIFICATIONS

Contact

Arrangement

 

2 Form C

 

 

Initial contact resistance

Max. 100 mΩ

(By voltage drop 6 V DC 1 A)

 

 

 

Contact material

Gold-clad silver alloy

 

 

 

 

 

 

Nominal switching

1 A 30 V DC, 0.3 A 125 V AC

 

 

capacity (resistive load)

 

 

 

 

 

 

 

 

 

Max. switching power

30 W (DC), 37.5 VA (AC)

Rating

 

(resistive load)

 

 

 

 

 

 

 

Max. switching voltage

110 V DC, 125 V AC

 

 

 

 

 

 

Max. switching current

1 A

 

 

 

 

 

 

Min. switching capability 1

1 mA 1 V DC

 

 

 

Nominal operating power

320 mW

 

 

 

 

Expected

 

Mechanical (at 180 cpm)

107

 

 

105

life (min.

 

 

Electrical (at 20 cpm)

(1 A 30 V DC,

operations)

 

 

 

0.3 A 125 V AC resistive)

Note:

1This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.

Remarks

* Specifications will vary with foreign standards certification ratings.

*1 Measurement at same location as "Initial breakdown voltage" section.

*2 By resistive method, nominal voltage applied to the coil; contact carrying current: 1A.

*3 Nominal voltage applied to the coil, excluding contact bounce time. *4 Halfwave pulse of sine wave: 11ms, detection time: 10 s

*5 Halfwave pulse of sine wave: 6ms *6 Detection time: 10 s

*7 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 61)

Characteristics

Initial insulation*1 resistance

Min. 1,000 MΩ (at 500 V DC)

Initial

 

Between contacts

750 V rms for 1 min.

 

 

 

 

 

Between contact and

 

breakdown

 

1,000 V rms for 1 min.

 

coil

 

voltage

 

 

 

 

 

 

 

 

Between contacts sets

1,000 V rms for 1 min.

 

 

 

 

 

 

Temperature rise*2

 

Max. 60°C

Operate time*3

 

Max. 6 ms (Approx. 4 ms)

(at 20°C 68°F)

 

 

 

Release time(without diode)*3

Max. 5 ms (Approx. 3 ms)

(at 20°C 68°F)

 

 

 

Shock resistance

Functional*4

Min. 100 m/s2 {10G}

Destructive*5

Min. 1,000 m/s2 {100G}

 

 

 

 

 

 

Functional*6

10 to 55 Hz

 

 

 

at double amplitude of 1.0 mm

Vibration resistance

 

 

 

Destructive

10 to 55 Hz

 

 

 

 

 

 

at double amplitude of 1.5 mm

 

 

 

 

 

 

 

 

 

 

 

 

Ambient

–40 to +70°C

Conditions for

temperature

–40 to +158°F

opetation, transport

Humidity

5 to 85% R.H.

and storage*7

 

 

 

 

Atmospheric

86 to 106 kPa

 

 

 

 

 

 

pressure

 

 

 

 

 

 

 

 

Unit weight

 

 

Approx. 2g .07 oz

 

 

 

 

 

TYPICAL

APPLICATIONS

Telephone exchange, transmission equipment

Communications devices

Measurement devices

Home appliances, and audio/visual equipment

Office equipment

ORDERING INFORMATION

 

Ex. HX

2

 

 

 

 

3V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact arrangement

 

 

 

 

 

 

 

 

Coil voltage(DC)

 

 

 

 

 

 

 

 

 

 

 

 

2: 2 Form C

 

 

 

 

 

 

 

 

1.5, 3, 4.5, 5, 6, 9, 12, 24 V

 

 

 

 

 

 

 

 

 

 

 

 

Note: 2,500V Surge (Bellcore) type is also available.

Please consult us for details.

183