VDE
1c, 2c, 4c
MINIATURE RELAY
FOR WIDER APPLICATIONS HC-RELAYS
20.8 |
27.2 |
20.8 |
27.2 |
|
.819 |
1.071 |
|||
.819 |
1.071 |
|||
|
|
|
|
|
|
|
|
|
|
|
|
35.2 |
35.2 |
|||
1.386 |
||||
1.386 |
||||
|
|
HCE Amber Relays
mm inch
FEATURES
•Extra long life — Min. 10 8 mechanical operations (DC type)
•4 contact arrangements
4 Form C (for 5 A 250 V AC),
3 Form C (for 7 A 250 V AC),
2 Form C (for 7 A 250 V AC),
1 Form C (for 10 A 250 V AC)
•Applicable to low to high level loads (100 A to 10A)
•Amber sealed types available
•Bifurcated contact types available as HC4D
SPECIFICATIONS
Contacts
Arrangement |
1 Form C |
2 Form C |
3 Form C |
4 Form C |
||
|
|
|
|
|
||
Initial current resistance, max. |
|
30 mΩ |
|
|||
(By voltage drop 6 V DC 1 A) |
|
|
||||
|
|
|
|
|||
Contact material |
Gold-flashed silver alloy |
Gold-clad |
||||
silver nickel |
||||||
|
|
|
|
|
||
|
Nominal |
10 A |
7 A |
7 A |
5 A |
|
|
switching capacity |
250 V AC |
250 V AC |
250 V AC |
250 V AC |
|
|
Max. switching |
2,500 VA |
1,750 VA |
1,750 VA |
1,250 VA |
|
Rating |
power |
|||||
|
|
|
|
|||
(resistive) |
Max. switching |
|
250 V AC |
|
||
|
voltage |
|
|
|||
|
|
|
|
|
||
|
Max. switching |
10 A |
7 A |
7 A |
5 A |
|
|
current |
|||||
|
|
|
|
|
Coil
Nominal operating power
AC (50Hz): 1.3VA, AC (60Hz): 1.2 VA
DC:0.9 to 1.1W
Remarks
* Specifications will vary with foreign standards certification ratings. *1 Detection current: 10 mA
*2 Excluding contact bounce time
*3 Half-wave pulse of sine wave: 11ms; detection time: 10 s *4 Half-wave pulse of sine wave: 6ms
*5 Detection time: 10 s
*6 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 61).
Characteristics
Max. operating speed |
|
20 cpm (at max. rating) |
||
|
|
|
||
Initial insulation resistance |
|
Min. 1,000 MW at 500 V DC |
||
|
|
|
|
|
Initial |
Between open contacts |
700 Vrms for 1 min. |
||
|
|
|
||
breakdown |
Between contact sets |
700 Vrms for 1 min. |
||
voltage*1 |
|
|
|
|
Between contact and coil |
2,000 Vrms for 1 min. |
|||
|
||||
|
|
|
|
|
Operate time*2 (at nominal voltage) |
Approx. 10 ms |
|||
(at 20°C) |
|
|
(DC, AC type) |
|
Release time (without diode)*2 |
Approx. 5 ms (DC type) |
|||
(at nominal voltage) (at 20°C) |
Approx. 10 ms (AC type) |
|||
Temperature rise, max. (at 70°C) |
80°C |
|||
(at nominal voltage) |
|
|||
|
|
|||
Shock resistance |
Functional*3 |
Min. 196 m/s2 {20 G} |
||
Destructive*4 |
Min. 980 m/s2 {100 G} |
|||
|
|
|||
|
|
Functional*5 |
10 to 55 Hz at double |
|
|
|
amplitude of 1 mm |
||
Vibration resistance |
|
|||
Destructive |
10 to 55 Hz at double |
|||
|
|
|||
|
|
amplitude of 2 mm |
||
|
|
|
||
|
|
|
||
Conditions for operation, |
Ambient |
–50°C to +70°C |
||
transport and storage*6 |
temp. |
–58°F to +158°F |
||
(Not freezing and condens- |
Humidity |
5 to 85% R.H. |
||
ing at low temperature) |
||||
|
|
|||
Unit weight |
|
|
Approx. 30g 1.06 oz |
Expected life (min. operations)
Electrical (at 20 cpm)
Voltage |
|
125 V AC |
250 V AC |
|
30 V DC |
|
||||
|
|
|
|
|
|
|
|
|
|
Expected life |
Load |
|
Resistive |
Inductive |
Resistive |
Inductive |
Resistive |
Inductive |
|||
|
(cos ϕ = 1) |
(cos ϕ ] 0.4) |
(cos ϕ = 1) |
(cos ϕ ] 0.4) |
|
|||||
|
|
|
|
|
|
|
||||
HC1 |
|
|
10A |
5A |
10A |
3A |
— |
|
— |
2×105 |
|
Current |
7A |
3A |
7A |
2.5A |
3A |
|
1A |
5×105 |
|
(1 Form C) |
|
|
||||||||
|
|
5A |
2A |
5A |
1.5A |
— |
|
— |
1×106 |
|
|
|
|
|
|||||||
HC2 |
|
|
7A |
3.5A |
7A |
2A |
— |
|
— |
2×105 |
|
Current |
5A |
2.5A |
5A |
1.5A |
3A |
|
0.6A |
5×105 |
|
(2 Form C) |
|
|
||||||||
|
|
3A |
1.5A |
3A |
1A |
— |
|
— |
1×106 |
|
|
|
|
|
|||||||
HC3 |
|
|
7A |
— |
7A |
— |
— |
|
— |
1×105 |
|
Current |
— |
3.5A |
— |
2A |
— |
|
— |
2×105 |
|
(3 Form C) |
|
|
||||||||
|
|
5A |
— |
5A |
— |
3A |
|
0.4A |
5×105 |
|
|
|
|
|
|||||||
HC4 |
|
|
5A |
2A |
5A |
1A |
— |
|
— |
2×105 |
|
Current |
3A |
1A |
3A |
0.8A |
3A |
|
0.4A |
5×105 |
|
(4 Form C) |
|
|
||||||||
|
|
2A |
0.5A |
2A |
0.4A |
— |
|
— |
1×106 |
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
||||
Mechanical life (at 180 cpm) |
|
|
DC type: 108 , AC type: 5×107 |
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
395
HC
TYPICAL APPLICATIONS
Transportation, power station control |
ed machines, amusement devices, medi- |
equipment, refrigerators, building control |
cal equipment, etc. |
equipment, office machines, coin operat- |
|
ORDERING INFORMATION
|
|
|
EX. HC |
4 |
|
|
D |
|
|
|
|
H |
|
|
|
AC 240V |
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Contact arrangement |
|
Type classifications |
|
|
|
|
|
|
|
|
|
|
Terminal arrangement |
|
Coil voltage |
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
1: 1 Form C |
|
Nil: Standard type |
|
|
|
|
|
|
|
|
|
H: Plug-in |
|
AC 6, 12, 24, 48, 120/240 V |
|||||||||||||
2: 2 Form C |
|
D: Bifurcated contact type |
|
|
|
|
|
|
|
|
|
HP: PC board terminal |
|
DC 6, 12, 24, 48, 110 V |
|||||||||||||
3: 3 Form C |
|
(HC4D only. See Page 400.) |
|
|
|
|
HTM: Top mounting |
|
|
|
|||||||||||||||||
4: 4 Form C |
|
K: Latching relay type |
|
|
|
|
|
|
|
|
|
HL: Light emitting diode |
|
|
|
||||||||||||
|
|
|
(HC2K only. See Page 401.) |
|
|
|
|
|
wired, plug-in |
|
|
|
|||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
HPL: Light emitting |
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
diode wired, PC |
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
board |
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Notes:
1.When ordering VDE recognized types, add suffix VDE.
2.HC3 (3 Form C) series are not approved by VDE.
3.AC 48 V type is not available for LED wiring.
4.Standard packing Carton: 20 pcs.; Case: 200 pcs.
5.UL/CSA approved type is standard.
COIL DATA (Common for Standard, Amber sealed and Bifurcated contact types)
DC Type at 20°C 68°F
Coil voltage, |
Pick-up voltage, |
Drop-out voltage, |
|
Max. allowable |
Coil resistance, |
Nominal coil |
Operating power, W |
|||||||
|
voltage, |
|
current, |
|
|
|||||||||
V DC |
V DC (max.) |
|
V DC (min.) |
|
|
Ω (±10%) |
Nominal |
Minimum |
||||||
|
|
V DC |
|
mA (±10%) |
||||||||||
|
|
|
|
|
|
|
|
|
|
|||||
6 |
4.8 |
|
0.6 |
|
6.6 |
|
|
40 |
|
150 |
0.9 |
0.58 |
||
12 |
9.6 |
|
1.2 |
|
13.2 |
|
160 |
|
75 |
0.9 |
0.58 |
|||
24 |
19.2 |
|
2.4 |
|
26.4 |
|
650 |
|
37 |
0.9 |
0.58 |
|||
48 |
38.4 |
|
4.8 |
|
52.8 |
|
2,600 |
|
18.5 |
0.9 |
0.58 |
|||
110 |
88.0 |
|
11.0 |
|
121.0 |
|
10,000 |
|
10 |
1.0 |
0.64 |
|||
AC Types (50/60 Hz) at 60 Hz, 20°C 68°F |
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
||
Coil voltage, |
|
Pick-up voltage, |
|
Drop-out voltage, |
|
Max. allowable |
|
Nominal coil |
Operating power, VA |
|||||
|
|
|
|
voltage, |
|
current, |
|
|
||||||
V AC |
|
V AC (max.) |
|
V AC (min.) |
|
|
V AC |
|
mA (±20%) |
Nominal |
Minimum |
|||
|
|
|
|
|
|
|
|
|
|
|
||||
6 |
|
4.8 |
|
|
1.8 |
|
|
|
6.6 |
|
200 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
12 |
|
9.6 |
|
|
3.6 |
|
|
|
13.2 |
|
100 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
24 |
|
19.2 |
|
|
7.2 |
|
|
|
26.4 |
|
50 |
1.20 |
0.77 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
48 |
|
38.4 |
|
|
14.4 |
|
|
|
52.8 |
|
25 |
|||
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
110/120 |
|
96 |
|
|
36 |
|
|
|
132 |
|
10.9/11.9 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
220/240 |
|
176.0 |
|
|
66.0 |
|
|
|
264.0 |
|
6.0/6.5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NOTES:
1.The range of coil current is ±15% for AC (60 Hz), and ±10% for DC, at 20°C.
2.The relay is applicable to the range of
80% to 110% of the nominal coil voltage. However, it is recommended that the relay be used in the range of 85% to 110% to take temporary voltage variations into consideration.
3.The coil resistance of DC types is the
measured value at a coil temperature of 20°C. Please compensate coil resistance by ±0.4% for each degree centigrade coil temperature change.
4.All AC 240 V types are rated for double coil voltages, both AC 220 V and AC 240 V.
5. For use with 220 V or 240 V DC, connect a resistor as suggested in the chart below, in series with the 110 V DC relay.
Voltage |
1 Form C, 2 Form C, |
|
3 Form C, 4 Form C |
||
|
||
|
|
|
220 V DC |
11 kΩ (5 W) |
|
240 V DC |
13 kΩ (5 W) |
396
HC
DIMENSIONS (Common for standard, Amber sealed and Bifurcated contact (4C only) types)
Plug-in type
HC1-H (1 Form C) |
|
HC2-H (2 Form C) |
|
HC3-H (3 Form C) |
||||||
|
20.8 |
|
|
20.8 |
|
|
|
20.8 |
|
|
|
.819 |
|
|
.819 |
|
|
|
.819 |
|
|
1.7 |
1.7 |
27.2 |
1.7 |
1.7 |
|
27.2 |
1.7 |
1.7 |
|
27.2 |
.067 |
.067 |
1.071 |
.067 |
.067 |
|
1.071 |
.067 |
.067 |
|
1.071 |
|
|
0.6 |
|
|
0.6 |
|
|
|
0.6 |
|
|
|
.024 |
|
|
.024 |
|
|
|
.024 |
|
|
|
35.2 |
|
|
35.2 |
|
|
|
35.2 |
|
|
|
1.386 |
|
|
1.386 |
|
|
|
1.386 |
|
|
|
1 |
|
|
1 |
|
|
|
1 |
|
|
|
.039 |
|
|
.039 |
|
|
|
|
|
|
|
|
|
|
|
|
.039 |
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
6.4 |
|
|
6.4 |
|
|
|
6.4 |
|
|
2.54 |
.252 |
|
2.54 |
.252 |
|
|
2.54 |
.252 |
|
|
|
|
|
|
|
|
|
|||
|
.100 |
0.5 |
|
.100 |
|
0.5 |
|
.100 |
|
0.5 |
|
13.35 |
.020 |
|
13.35 |
4.41 |
.020 |
|
13.35 |
4.41 |
.020 |
|
|
|
.526 |
.174 |
|
|
.526 |
.174 |
|
|
4.45 |
.526 |
4.41 |
|
|
|
|
|
|||
|
|
4.06 |
|
|
|
4.06 |
|
|||
.175 |
|
.174 |
|
|
|
|
|
|
||
|
|
4.06 |
|
|
.160 |
|
|
|
.160 |
|
|
|
|
|
6.35 |
|
|
|
6.35 |
|
|
|
|
.160 |
|
|
|
|
|
|
||
|
|
|
|
.250 |
|
|
|
.250 |
|
|
|
|
6.35 |
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
.250 |
|
|
|
|
|
|
|
|
|
|
|
|
|
6.35 |
|
|
|
6.35 |
|
|
|
6.35 |
|
|
.250 |
|
|
|
.250 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
.250 |
|
|
|
|
|
|
|
|
mm inch
HC4-H (4 Form C)
|
20.8 |
|
|
1.7 |
.819 |
|
|
1.7 |
|
27.2 |
|
.067 |
.067 |
|
1.071 |
|
|
0.6 |
|
|
|
.024 |
|
|
|
35.2 |
|
|
|
1.386 |
|
|
|
1 |
|
|
|
.039 |
|
|
|
6.4 |
|
|
2.54 |
.252 |
|
|
|
|
|
|
.100 |
|
0.5 |
4.45 |
13.35 |
4.41 |
.020 |
.526 |
.174 |
|
|
.175 |
|
|
|
4.06
.160
6.35
.250
6.35
.250
General tolerance: ±0.2 ±.008
PC board type
HC4-H (4 Form C)
|
20.8 |
|
|
1.7 |
.819 |
|
|
1.7 |
|
27.2 |
|
.067 |
.067 |
|
1.071 |
|
|
0.6 |
|
|
|
.024 |
|
|
|
35.2 |
|
|
|
1.386 |
|
|
|
1 |
|
|
|
.039 |
|
|
|
1.5 |
|
|
|
.059 |
|
|
1.5 |
3.5 |
|
|
.059 |
0.5 |
|
|
.138 |
||
|
13.35 |
|
.020 |
|
4.41 |
|
|
4.45 |
.526 |
|
|
.174 |
|
||
.175 |
|
|
|
4.06
.160
6.35
.250
6.35
.250
General tolerance: ±0.2 ±.008
Dimensions of HC1-HP, HC2-HP, HC3-HP are the same as those of plug-in type except shapes of terminals.
PC board pattern (Copper-side view)
1c |
2c |
|
4.1 |
|
4.1 |
.161 |
|
.161 |
|
|
16.8 |
|
|
.661 |
|
|
10.4 |
4.45 |
|
.409 |
|
8-2 dia. |
|
.175 |
13.35 |
|
8 |
8-.079 dia. |
|
.350 |
.526 |
|
3c |
|
4c |
|
|
4.1 |
|
4.1 |
|
.161 |
|
.161 |
|
10.4 |
|
|
|
.409 |
|
16.8 |
|
16.8 |
|
.661 |
|
.661 |
|
10.4 |
13.35 |
11-2 dia. |
4.45 |
.409 |
|
|||
.526 |
11-.079 dia. |
.175 |
14-2 dia. |
|
8.9 |
||
|
|
14-.079 dia. |
|
|
|
.350 13.35 |
|
|
|
.526 |
|
Tolerance: ±0.1 ±.004
Note: Special PC terminal with 0.9 mm (.035 inch) width available with suffix "-31".
Schematic (bottom view) |
|
|
|
|
|
|
|
|
|
|
|
|
|
HC1-H, HC1-HP (1 Form C) |
HC2-H, HC2-HP (2 Form C) |
HC3-H, HC3-HP (3 Form C) |
HC4-H, HC4-HP (4 Form C) |
||||||||||
2 |
|
|
1 |
4 |
|
1 |
2 |
3 |
1 |
2 |
3 |
4 |
|
7 |
12 |
|
5 |
8 |
|
4 |
5 |
6 |
5 |
6 |
7 |
8 |
|
|
|
|
9 |
12 |
|
7 |
8 |
9 |
|
|
|
|
|
13 |
14 |
|
13 |
14 |
|
|
|
|
|
9 |
10 |
11 |
12 |
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
14 |
|
|
|
14 |
|
|
|
|
|
|
|
13 |
|
13 |
|
|
|||
LED AC type |
|
LED AC type |
|
LED AC type |
|
LED AC type |
|||||||
2 |
|
1 |
|
4 |
|
1 |
|
2 |
3 |
1 |
2 |
3 |
4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
7 |
12 |
5 |
|
8 |
|
4 |
|
5 |
6 |
5 |
6 |
7 |
8 |
|
9 |
|
12 |
|
7 |
8 |
9 |
|
|
|
|
||
|
|
|
|
|
|
|
|
||||||
13 |
14 |
13 |
|
14 |
13 |
|
|
|
9 |
10 |
11 |
12 |
|
( ) |
( ) |
|
|
|
14 |
13 |
|
|
|
||||
|
( ) |
|
|
( ) |
|
) |
|
|
( ) |
|
|
14 |
|
|
|
|
|
|
( |
|
|
( ) |
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
( ) |
|
LED DC type |
|
LED DC type |
|
LED DC type |
|
LED DC type |
|||||||
2 |
|
1 |
|
4 |
|
1 |
2 |
3 |
1 |
2 |
3 |
4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
7 |
12 |
5 |
|
8 |
|
4 |
5 |
6 |
5 |
6 |
7 |
8 |
|
|
9 |
|
12 |
|
7 |
8 |
9 |
|
|
|
|
||
|
|
|
|
|
|
|
|
||||||
13 |
14 |
13 |
(−) |
14 |
13 |
|
|
|
9 |
10 |
11 |
12 |
|
(−) |
|
|
|
14 |
13 |
|
|
|
|||||
|
(+) |
|
|
(+) |
|
− |
) |
|
(−) |
|
|
14 |
|
|
|
|
|
|
|
( |
|
(+) |
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
(+) |
397
HC
REFERENCE DATA
1. Life curve |
2. Switching capacity range |
3. H2S gas test |
Load: 250 V AC resistive load
10,000 |
Mechanical life (DC type) |
|
|
|
|
|
|
|
||||
|
5,000 |
|
|
|
|
|
resistanceContact |
100Ω |
||||
10Life,× |
|
|
|
|
|
Vvoltage,AC |
|
HC2c, 3c |
||||
times |
Mechanical life (AC type) |
|
250 |
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
||||
4 |
|
|
|
|
|
|
100 |
|
|
|
|
10Ω |
|
|
|
|
|
|
|
|
|
HC4c |
|
|
|
|
500 |
|
|
|
|
|
|
|
|
|
|
1Ω |
|
400 |
|
1c |
(250 V AC cosϕ = 1) |
10 |
|
|
|
|
|
||
|
300 |
|
|
HC1c |
|
|
100mΩ |
|||||
|
|
2c |
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
||
|
200 |
3c |
|
|
|
|
|
|
|
|
|
10mΩ |
|
100 |
|
|
|
|
|
|
|
|
|
||
|
4c |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
110 |
|
|
|
2 |
4 |
6 |
8 |
10 |
1mA |
10mA |
1A |
5A 10A |
|
|
|
|
|
|
|
|
|
|
|
AC current |
7A |
|
|
|
|
|
|
Load current, A |
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
Standard HC relay
Gas density:
2 to 5 ppm Temperature: 40°C Humidity: 90% RH
HCE Amber relay
20 50 100 200 500 1000 2000 5000
Exposure time, Hrs.
4. Coil temperature rise
Measured portion: Inside the coil Note: When the nominal voltage is applied to AC 120 or 240 V coil types respectively, the figures of coil temperature rise increase by approx. 10 degrees to the ones shown on each graph.
HC1 AC coil
Ambient temperature: 25°C 77°F |
|
|
||||
|
100 |
|
|
|
|
|
°C |
90 |
|
|
|
|
|
80 |
|
|
|
|
10A |
|
rise, |
|
|
|
|
||
70 |
|
|
|
|
7A |
|
Temperature |
|
|
|
|
||
|
|
|
|
|
5A |
|
60 |
|
|
|
|
2A |
|
|
|
|
|
|
0A |
|
50 |
|
|
|
|
|
|
40 |
|
|
|
|
|
|
|
30 |
|
|
|
|
|
|
20 |
|
|
|
|
|
|
10 |
|
|
|
|
|
|
0 |
80 |
90 |
100 |
110 |
120 |
|
|
Coil applied voltage, %V
HC2 AC coil
Ambient temperature: 30°C 86°F |
|
|
||||
|
100 |
|
|
|
|
|
|
90 |
|
|
|
|
7A |
°C |
80 |
|
|
|
|
|
rise, |
|
|
|
|
|
|
70 |
|
|
|
|
5A |
|
Temperature |
60 |
|
|
|
|
0A |
|
|
|
|
|
||
50 |
|
|
|
|
|
|
40 |
|
|
|
|
|
|
|
30 |
|
|
|
|
|
|
20 |
|
|
|
|
|
|
10 |
|
|
|
|
|
|
0 |
80 |
90 |
100 |
110 |
120 |
|
|
Coil applied voltage, %V
HC3 AC coil
Ambient temperature: 18°C 64°F
|
|
100 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
7A |
|
|
|
90 |
|
|
|
|
|
|
|
|
|
|
|
|
°C |
|
|
|
|
|
|
|
|
|
|
|
|
||
80 |
|
|
|
|
|
|
|
|
|
|
|
|
||
rise, |
|
|
|
|
|
|
|
|
|
|
|
5A |
||
|
|
|
|
|
|
|
|
|
|
|
|
|||
Temperature |
70 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0A |
|||
40 |
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
60 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
50 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
30 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
20 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
10 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
80 |
90 |
100 |
110 |
120 |
||||||||
|
|
|
Coil applied voltage, %V
HC2 DC coil
Ambient temperature: 29°C 84°F |
|
|
||||
|
100 |
|
|
|
|
|
|
90 |
|
|
|
|
|
°C |
80 |
|
|
|
|
|
rise, |
|
|
|
|
|
|
70 |
|
|
|
|
7A |
|
|
|
|
|
|
||
Temperature |
|
|
|
|
|
|
60 |
|
|
|
|
5A |
|
50 |
|
|
|
|
||
|
|
|
|
0A |
||
40 |
|
|
|
|
|
|
|
30 |
|
|
|
|
|
|
20 |
|
|
|
|
|
|
10 |
|
|
|
|
|
|
0 |
80 |
90 |
100 |
110 |
120 |
|
|
|||||
|
|
|
Coil applied voltage, %V |
HC4 AC coil |
HC1 DC coil |
Ambient temperature: 15 to 21°C 59 to 70°F |
Ambient temperature: 29°C 84°F |
|
|
||||||||||
|
|
|
|
|
|
|
|
100 |
|
|
|
|
|
°C |
180 |
|
|
|
|
|
°C |
90 |
|
|
|
|
|
160 |
|
|
|
|
|
80 |
|
|
|
|
|
||
rise, |
|
|
|
|
|
rise, |
|
|
|
|
|
||
140 |
|
|
|
|
|
70 |
|
|
|
|
|
||
Temperature |
|
|
|
|
|
Temperature |
|
|
|
|
|
||
120 |
|
|
|
|
5A |
60 |
|
|
|
|
10A |
||
|
100 |
|
|
|
|
3A |
|
50 |
|
|
|
|
5A |
|
|
|
|
|
|
|
|
|
|
0A |
|||
|
80 |
|
|
|
|
1A |
|
40 |
|
|
|
|
|
|
60 |
|
|
|
|
|
|
30 |
|
|
|
|
|
|
40 |
|
|
|
|
|
|
20 |
|
|
|
|
|
|
20 |
|
|
|
|
|
|
10 |
|
|
|
|
|
|
0 |
80 |
90 |
100 |
110 |
120 |
|
0 |
80 |
90 |
100 |
110 |
120 |
|
|
|
|
||||||||||
|
|
|
Coil applied voltage, %V |
|
|
|
Coil applied voltage, %V |
HC3 DC coil |
HC4 DC coil |
Ambient temperature: 29°C 84°F |
|
|
Ambient temperature: 17 to 18°C 62 to 64°F |
||||||||||
|
100 |
|
|
|
|
|
|
100 |
|
|
|
|
|
Temperaturerise, °C |
90 |
|
|
|
|
|
|
90 |
|
|
|
|
|
80 |
|
|
|
|
|
Temperaturerise, °C |
80 |
|
|
|
|
5A |
|
40 |
|
|
|
|
7A |
40 |
|
|
|
|
|||
|
70 |
|
|
|
|
|
|
70 |
|
|
|
|
|
|
60 |
|
|
|
|
5A |
|
60 |
|
|
|
|
3A |
|
50 |
|
|
|
|
0A |
|
50 |
|
|
|
|
1A |
|
|
|
|
|
|
|
|
|
|
|
|
||
|
30 |
|
|
|
|
|
|
30 |
|
|
|
|
|
|
20 |
|
|
|
|
|
|
20 |
|
|
|
|
|
|
10 |
|
|
|
|
|
|
10 |
|
|
|
|
|
|
0 |
80 |
90 |
100 |
110 |
120 |
|
0 |
80 |
90 |
100 |
110 |
120 |
|
|
|
|
||||||||||
|
|
|
Coil applied voltage, %V |
|
|
|
|
Coil applied voltage, %V |
398