Important safeguards

Use this appliance only as described in this instruction manual.

As with any electrical appliance, the instructions aim to cover as many situations as possible. Caution and common sense should be used when operating and installing this air conditioner.

This appliance has been manufactured to cool and dehumidify domestic environments and must not be used for other purposes.

It is dangerous to alter or modify the unit's characteristics in any way.

The appliance must be installed in accordance with the relevant national legislation.

Should repairs be necessary, contact the nearest authorized Repair Service Center. Unauthorized servicing can be dangerous.

The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

In the case that the power cord becomes damaged, this must be repaired only by specialized personnel authorized by the manufacturer in order to protect against fire.

Always ensure the appliance is plugged into a grounded 3-prong outlet. If you have any doubts check with a qualified electrician.

We strongly discourage the use of an extension cord due to potential safety hazards.

Before cleaning or maintenance operations, always unplug the unit from the outlet.

Do not pull on or place strain on the power cord when moving the appliance.

The appliance should not be installed where the atmosphere may contain combustible gases, oil or sulphur, or near heat sources.

Do not rest hot or heavy objects on the appliance.

Clean the filters at least once a week.

Avoid using heaters near the unit.

The unit should be transported in a vertical position. If this is not possible secure the unit at an angle, do not lie it horizontally.

Before transporting the unit, drain the unit. After transportation, wait at least 6 hours before switching the unit on.

The packaging materials can be recycled. You are therefore recommended to place them in the special containers for differentiated waste collection.

This appliance is fitted with a special safety device. When the compressor switches off, this device prevents it from switching on again for at least 3 minutes.

WARNING: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

SAVE THESE INSTRUCTIONS

THIS PRODUCT IS FOR HOUSEHOLD ONLY

DESCRIPTION

1

air outlet grille

12

air exhaust hose

2

control panel

13

hose adaptor (2 pieces)

3

castors

14

accessory for wall mounting

4

handles

15

window bracket grille

5

filter

16

window bracket cap

6

evaporator air intake grille

17

window bracket

7

air exhaust hose housing

18

additional window bracket

8

condenser air intake grille

19

6 screws

9

power cable

20

window outlet

10 drainage hose

21

remote control

11 wall flange

4

Pr e p a r i n g f o r u s e

ELECTRICAL CONNECTIONS

Before plugging the appliance into the mains socket, check that:

• The outlet’s power supply corresponds to the value indicated on the rating label on the back GB of the appliance;

The outlet and electrical circuit are adequate for the appliance;

The outlet is a 3-hole grounded outlet . If this is not the case, you must choose another outlet.

Failure to follow these important safety instructions absolves the manufacturer of all liability.

The power cable must be replaced by a qualified professional only.

The instructions below will enable you to prepare your air conditioner for operation as efficiently as possible. Before use, make sure the air intake and outlet grilles are unobstructed.

AIR-CONDITIONING WITHOUT INSTALLATION

Just a few simple steps and your comfort is ensured with your air conditioner:

Screw one hose adaptor

 

13

to the hose’s

 

 

 

 

 

 

 

 

 

 

 

 

 

end

12

.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fit the other hose adaptor

 

13

in the air

 

exhaust hose housing

 

 

 

 

at the back of

 

 

7

 

 

 

the appliance (see fig. A).

 

 

 

 

Screw the other end of the hose to the adaptor, that was already fitted to the appliance (see fig. A).

A

Sash window

• Attach the window bracket grille 15 to the window bracket 17 with the four screws provided 19 (fig. B).

B

Open the window.

Place the window bracket 17 in the window, extending it to fit the width of the window (fig. C).

C

D

Once the bracket is extended, it can be locked into his width by tightening the last two screws provided.

Close the window (fig. D).

Place the air conditioner near the window. Insert the assembled exhaust hose

12 into the window bracket grille 17 (fig.

E). Make sure the air exhaust hose is unob-

structed.

 

• When not used,

bracket can

be closed off

16 provided.

E

If you have a very large window, in order to cover your window aperture, use the additional window bracket without holes extending it to the desired dimension, then fix the bracket by using the pins provided. When extracting the window bracket and joining the two pieces pay attention you do not cover the hole or holes (depending on the model).

Keep the air hoses as short and free of curves as possible to avoid constrictions.

5

Delonghi Pacn100e Owner's Manual

Pr e p a r i n g f o r u s e

French window

Attach the window outlet 20 to the air exhaust hose as shown in fig. F.

2 1

F

Open the French window slightly and position the outlet 20 as shown in figure G

G

Keep the air hoses as short and free of curves as possible to avoid constrictions.

SEMI-PERMANENT INSTALLATION

If required, your appliance can also be installed semi-permanently (Fig. H).

30 cm

H

30 cm

Proceed as follows:

Drill a hole (ø134mm / 5,27 in.) in an outside wall or through a window pane. Respect the height and dimensions of the hole given in figures M and I.

134 5,27 in.

in the window

in the wooden

in the wall: you are

pane

 

kickboard of a

recommended

to

 

 

 

French window

insulate the section

 

I

 

 

 

of wall using suit-

 

 

 

 

able insulation.

 

Fit the wall flange 11

into the hole.

 

Screw the hose 12

to the adaptor 13

,

 

that was already fitted to the appliance (fig.

 

A).

 

 

 

 

 

Remove the

 

L

 

 

plastic

end

 

 

 

 

 

 

 

of the

hose

 

1

 

 

12

b

y

 

 

 

 

 

 

 

unscrewing it

 

 

 

 

and

in

its

 

2

 

 

place

screw

 

 

 

 

 

 

 

the

 

wall

 

 

 

 

m o u n t i n g

 

 

 

 

a c c e s s o r y

 

 

 

14(fig. L).

Fit the end of the hose 12 to the wall

flange 11 as shown in fig. M.

MAX100 cm

MAX 39,37 inches

MIN 35 cm

MAX 13,77 inches

M

When the hose 12 is not fitted, the hole can be closed with the flange cap 11 .

NOTE: When installing the air conditioner semi-permanently, you should leave a door slightly open (as little as 1 cm) to guarantee correct ventilation.

6

Control panel

THE CONTROL PANEL

GB

S H

G

Q O P I L T

NM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DESCRIPTION OF THE CONTROL PANEL

AON/OFF button

BMODE selection button

Air conditioning, dehumidifying, fan.

CFan speed selection button (MAX/MED/MIN)

DTimer button

EProgrammed operation increase temperature/time button

FProgrammed operation decrease temperature/time button

GDisplay Displays the temperature values set and the programmed operating time

HTimer in operation indicator light

I/L/M Fan speed lights

NFan mode light

OAir-conditioning mode light

PDehumidifying mode light

QAlarm light

RRemote control receiver

SLight: the inner temperature is shown on the display

TLight: the outdoor temperature is shown on the display

Never turn the air conditioner off by unplugging from the outlet. Always press the button, then wait for a few minutes before unplugging. This allows the appliance to perform a cycle of checks to verify operation.