Important safeguards

Use this appliance only as described in this instruction manual.

As with any electrical appliance, the instructions aim to cover as many situations as possible. Caution and common sense should be used when operating and installing this air conditioner.

This appliance has been manufactured to cool and dehumidify domestic environments and must not be used for other purposes.

It is dangerous to alter or modify the unit's characteristics in any way.

The appliance must be installed in accordance with the relevant national legislation.

Should repairs be necessary, contact the nearest authorized Repair Service Center. Unauthorized servicing can be dangerous.

The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

In the case that the power cord becomes damaged, this must be repaired only by specialized personnel authorized by the manufacturer in order to protect against fire.

Always ensure the appliance is plugged into a grounded 3-prong outlet. If you have any doubts check with a qualified electrician.

We strongly discourage the use of an extension cord due to potential safety hazards. For temporary situations, use only CSA certified and UL listed 3-prong grounded extension cord, attachment plug and connector, rated 15A, 125V

Before cleaning or maintenance operations, always unplug the unit from the outlet.

Do not pull on or place strain on the power cord when moving the appliance.

The appliance should not be installed where the atmosphere may contain combustible gases, oil or sulphur, or near heat sources.

Do not rest hot or heavy objects on the appliance.

Clean the filters at least once a week.

Avoid using heaters near the unit.

The unit should be transported in a vertical position. If this is not possible secure the unit at an angle, do not lie it horizontally.

Before transporting the unit, drain the unit. After transportation, wait at least 6 hours before switching the unit on.

The packaging materials can be recycled. You are therefore recommended to place them in the special containers for differentiated waste collection.

This appliance is fitted with a special safety device. When the compressor switches off, this device prevents it from switching on again for at least 3 minutes.

WARNING: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

.

SAVE THESE INSTRUCTIONS

THIS PRODUCT IS FOR HOUSEHOLD ONLY

DESCRIPTION

1

air outlet grille

9

power cable

2

control panel

10 wall flange

3

castor wheels

11

air exhaust hose

4

handles

12

window outlet

5

filter

13

castor locks

6

air intake grille

14

remote control

7

air exhaust hose housing

15

window bracket with locking pins

8

drainage hose

 

 

4

 

 

 

Setting up your portable air conditioner

TO AVOID DAMAGE TO THE UNIT:

NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR ON ITS SIDE. IF THIS OCCURS, WAIT

GB

6 HOURS BEFORE TURNING THE APPLIANCE ON, 24 HOURS IS RECOMMENDED. (After the unit has

 

been on its side, oil needs to return to the compressor to ensure proper function. Without allow-

 

ing the unit this time (6-24 hours) The unit may function for only a short time, and then the com-

 

pressor will break down from lack of oil.)

 

ELECTRICAL CONNECTIONS

 

Before plugging the appliance into the outlet, check that:

 

The outlet’s power supply corresponds to the value indicated on the rating label on the back of the appliance;

The outlet and electrical circuit are adequate for the appliance;

The outlet is a 3-hole grounded outlet. If this is not the case, you must choose another outlet.

Failure to follow these important safety instructions absolves the manufacturer of all liability.

If it becomes necessary, the power cable must be replaced by a qualified professional only.

The instructions below will enable you to prepare your air conditioner for operation as efficiently as possible. Before use, make sure the air intake and outlet grilles are unobstructed.

AIR CONDITIONING WITHOUT INSTALLATION

NOTE: Keep the air hoses as short and free of curves as possible to avoid constrictions.

FOR OPTIMAL RESULTS SET-UP IN A DOU- BLE-HUNG WINDOW:

1)Place the bracket in the window sill, extend the bracket fully within the window frame, fix the bracket by using the pin then lower the window onto the bracket. (Should the window bracket be too large for the window. The plastic can be cut with a saw by a qualified professional.)

2)Fit the air exhaust hose in the housing at

the back of the

appliance. Insert it as

shown in figure

A.

3)Connect the window outlet (12 ) to the other end of the exhaust hose.

2

1

A

4)Insert the window outlet end of the exhaust hose into the slot of the window bracket (fig. B ).

B

Other set-up methods:

Thanks to the locking pins, it’s possible to use the window bracket also for sliding

windows. Position the hole of the bracket

so to allow a correct installation of the

exhaust hose (see figure

C ).

C

If you have a casement window (figure D ) follow steps 2 & 3 and place the window outlet ( 12 ) outside the window to exhaust the hot air.

D

For help with installation, operation, and for all accessories and spare/replacement parts, Please contact our toll free cus-

tomer service call center at:

1-800-322-3848 [US only]

Monday – Friday 8:30am – 5:00pm ET Or log onto our website at www.delonghiusa.com.

5

De'Longhi pinguino pac ct90 User Manual

Semi-permanent installation

SEMI-PERMANENT INSTALLATION

If required, your appliance can also be installed semi-permanently (Fig. E).

Fit the wall flange (

10 ) into the hole.

Fit the air exhaust hose (

11 ) in the rele-

 

vant housing located on the rear side of

 

the appliance. (fig.

pageA

5).

Fit the end of the hose (11 ) to the wall flange (10 ) as shown in fig. . G

 

30 cm

 

11,8 inches

30 cm

E

11,8 inches

 

Proceed as follows:

• Drill a hole ø 5,25 inches (134 mm) in an outside wall or through a window pane. Respect the dimensions and height of the hole given in figure andF G .

134 5,27 in.

in the

in the

in the wall:

window

wooden

you are

pane

kickboard

recommended

 

 

of a

to insulate the

 

 

French

section of wall

 

 

window

using suitable

F

 

 

insulation.

 

 

 

 

“As special tools are required for installation, we suggest you have the appliance installed by specialized personnel.”

MAX100 cm

MAX 39,37 inches

MIN 35 cm

MAX 13,77 inches

G

When the hose ( 11 ) is not connected, the drilled hole can be closed with the flange cap

(10 ).

NOTE: When installing the air conditioner semi-permanently, you should leave a door slightly open little as 1/2 “ (1 cm) to guarantee correct ventilation and room pressure.

Keep the air hoses as short and free of curves as possible to avoid constrictions.

6

Control panel

THE CONTROL PANEL

GB

C

 

 

F

 

 

G

 

R

H

E

 

B

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I

 

 

 

 

 

 

 

 

Q

 

L

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M

 

 

 

 

 

 

 

 

 

 

 

 

P

 

 

 

 

 

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

O

 

 

 

 

 

 

 

 

DESCRIPTION OF THE CONTROL PANEL

A ON/STAND-BY button

B MODE selection button:

Air conditioning, dehumidifying, fan.

CFan speed selection button (HIGH/MED/LOW/AUTO)

DTimer button

EProgrammed operation increase temperature/time button

FProgrammed operation decrease temperature/time button

GDisplay Displays the temperature values set and the programmed operating time

HTimer in operation indicator light

I/L/M/N Fan speed lights

andAUTO lights

O

Fan mode light

 

P

Dehumidifying mode light

 

Q

Air conditioning mode

light

R

Remote control receiver

Never turn the air conditioner off by unplugging from the outlet. Always press the button, then wait for a few minutes before unplugging. This allows the appliance to perform a cycle of checks to verify operation.

7

Operation

TURNING THE APPLIANCE ON

Plug into an outlet.

Two lines appear on the display indicating that the appliance is in standby.

Press the ON/STAND-BY button ( A ). When turned on, the air conditioner starts operating in the same mode as when it was turned off.

Press the MODE button ( B ) until the light corresponding to the desired mode lights up:

Light ( Q ) : air-conditioning mode

Light ( P )

: dehumidifying mode

Light ( O ) : fan mode

AIR CONDITIONING MODE

Ideal for hot muggy weather when you need to cool and dehumidify the room.

To set this mode: press the + (E) or - ( F) buttons until the desired temperature is displayed.

Then select the fan speed by pressing the button (C ) until the light corresponding to the required fan speed lights up:

MAXIMUM SPEED the air conditioner operates at maximum to achieve the target temperature as rapidly as possible

MEDIUM SPEED reduces noise levels while maintaining a comfortable temperature

LOW SPEED for silent operation and maxium energy efficiency

AUTO : the appliance automatically selects the most suitable fan speed in relation to the temperature set on the digital display and current room temperature.

The most suitable temperature for the room during the summer varies from 75°F to 81°F (24 to 27°C). You are recommended, however, not to set a temperature much below the outdoor temperature

DEHUMIDIFYING MODE

Ideal to reduce room humidity (spring and autumn, damp rooms, rainy

periods, etc). In dehumidifying mode, the appliance

beMUSTset-up in

the same way as for air conditioning, with the air exhaust hose attached

to enable the moisture to be discharged outside.

P ) comes on and

When the dehumidifying mode is selected, the light (

” appears on the display.

 

At the same time, the

AUTOfan light ( N ) comes on.

 

In this mode, fan speed is selected automatically by the appliance and cannot be set manually.

FAN MODE

The unit operates without cooling or dehumidifying. This mode provides ventilation only. When using the appliance in this mode, the air exhaust hose does not need to be connected. Adjust fan speed by pressing the

button ( C ) as described for the air-conditioning mode. In this mode, AUTO speed cannot be selected.

The fan speed selected will be displayed.

8

Loading...