Comelit 6601W, BM User Manual

5 (1)

EN

TECHNICAL MANUAL

Icona door entry monitor

 

Art. 6601W - Art. 6601W/BM

Passion.Technology. Design.

Table of contents

Warning

Table of contents..............................................................................

2

Monitor description.........................................................................

3

Soft-touch key activation.........................................................................

4

Soft-touch key description......................................................................

4

Indicator LED description........................................................................

4

Technical specifications..................................................................

5

Installation........................................................................................

7

Mounting the Icona SBC monitor on flush-mounted box Art. 6117.....

7

Wall-mounting (Art. 6620) / on 503 series box/round box.....................

8

Connections.....................................................................................

9

Variant: connection of call repetition device Art. 1122/A......................

9

Monitor configuration....................................................................

10

Standard configuration for soft-touch keys.........................................

10

Activation/deactivation Doctor function..............................................

10

Activation/deactivation Hands-Free function......................................

10

Configuration of Main and Secondary internal units - DIP 8 of S2....

11

Power supply configuration and management - DIP 7 of S2..............

11

Advanced monitor configuration...........................................................

12

Warning.............................................................................................

12

Programming for intercom call..........................................................

12

Programming/deleting intercom address (selective intercom only)

12

 

Programming buttons for intercom call......................................

13

Direct programming of intercom call..........................................

14

Programming keys for generic or coded actuator.............................

15

Programming buttons for other functions.........................................

16

Programming range...........................................................................

17

LED/alarm/lock-release/actuator programming................................

18

Changing monitor ringtones..............................................................

19

Programming reset............................................................................

19

System performance and layouts.................................................

19

2

Comelit 6601W, BM User Manual

Monitor description

The Icona series is comprised of hands-free monitors that can be used in “Building Kit” (exclusively 2-wire), Simplebus Top and Kit Video systems

Article 6601W is a colour monitor equipped as standard with 9 function buttons and 6 adjustment buttons.

Article 6601W/BM is a colour monitor equipped as standard with 9 buttons, 6 adjustment buttons and an induction loop.

1

2

3

4

 

5

 

11

 

 

10

6

 

7

 

 

 

 

8

B

 

A

 

9

 

1. Microphone

2. 4.3’’ LCD screen

3. Soft-touch keys/LED

4. Loudspeaker

5. S1 User code programming microswitches (see Addressing table)

6. CV1 CV2 remove in case of separate power supply.

7. CV5 Jumper for video closure. In systems with more than one monitor connected in cascade, only the monitor furthest away must have CV5 closed.

8.CV6

position A = contact IN1-IN2 > LED (default)

position B = contact CFP2-IN1 > ALARM/LOCK-RELEASE/ACTUATOR

9. S2 Microswitches for programming buttons and functions (marked with a red corner) DIP 1-2-3-4 for button function programming

DIP 5-6 access to programming

DIP 7 for management of power supply voltage, see “Power supply configuration and management”

DIP 8 for main and secondary monitor setting, see “Configuration of Main and Secondary internal unit”

10.M2 Terminal block for system connection: CFP1 CFP2 Floor door call input

S+ S- Call repetition device terminals IN1 IN2 LED input (programmable)

11.M1 Terminal block for system connection: L L Bus line connection terminals

- + Power supply terminals

3

Soft-touch key activation

 

1

 

2

x2

 

ff Swipe to enable function key row (1). ff Swipe to enable function key row (2).

ff Press the desired key once to activate the function associated with it

Soft-touch key description

Wait for approximately 1 sec. before pressing the same key again. Pressing the same key several times in quick succession will cancel the command

Audio key

Lock-release key

Keys 1-2-3-4-5 (programmable)

Self-ignition key (programmable)

Privacy key

Call volume key

Ringtone volume key

Value 'Up/Down' key

Contrast key

Brightness key

Indicator LED description

Audio LED

steady = audio enabled/hands-free function continuous flashing = call received

Lock-release LED

1 flash = confirm lock-release

4 flashes = programming successful

10 flashes = programming error continuous flashing = door open

Privacy LED - Doctor

4 flashes = device engaged slow flashing = programming

3 flashes (every 5 s.) = Doctor function enabled steady = privacy function enabled

The monitor Art. 6601W is designed for use in colour systems, in the SB2 section downstream of Art. 4888C, or in systems without mixer, such as the system with 2-wire KIT or Art. 1210.

4

Technical specifications

MAIN SPECIFICATIONS

6601W

6601W/BM

Flush-mounted

Yes

Yes

Wall-mounted

Yes

Yes

Desk base-mounted

Yes

Yes

Hands-free function

Yes

Yes

Induction loop

/

Yes

Type of display

LCD

LCD

Display size (inches)

4,3'' 16:9

4,3'' 16:9

Display resolution (H x V)

480 x 272

480 x 272

B/W or colour display

Colors

Colors

Product colour

White RAL9003

White RAL9003

Sensitive Touch technology

Yes

Yes

Total buttons

15

15

COMPATIBILITY

 

 

Simplebus Top audio/video system

Yes

Yes

Building Kit audio/video system

Yes

Yes

Kit audio/video system

Yes

Yes

FUNCTIONS

 

 

Actuator control function

Yes

Yes

Self-ignition

Yes

Yes

Switchboard call function

Yes

Yes

Priority calls

Yes

Yes

Intercom function

Yes

Yes

Selective intercom call

Yes

Yes

Call to multiple addresses

Yes

Yes

Call to group addresses

Yes

Yes

Call forwarding

Yes

Yes

Privacy function

Yes

Yes

Doctor

Yes

Yes

Redial

Yes

Yes

Floor door call function

Yes

Yes

Electronic bell

Yes

Yes

Customisable ringtone

Yes

Yes

Privacy conversation function

Yes

Yes

Key button function

Yes

Yes

HARDWARE SPECIFICATIONS

 

 

Removable terminals

Yes

Yes

SETTINGS

 

 

Loudspeaker volume control

Yes

Yes

Microphone volume control

Yes

Yes

Ringtone volume control

Yes

Yes

Display brightness control

Yes

Yes

Display contrast control

Yes

Yes

5

GENERAL INFO

6601W

6601W/BM

Product height (mm)

147

147

Product width (mm)

142,5

142,5

Product depth (mm)

23

23

TECHNICAL SPECIFICATIONS

 

 

Power supply voltage

22÷28Vdc

22÷28Vdc

Operating temperature (°C)

-5÷40

-5÷40

Relative humidity for operation

25 - 75 %

25 - 75 %

Clamps

L L - + CFP1 CFP2 S+ S- IN1 IN2

L L - + CFP1 CFP2 S+ S- IN1 IN2

6