EN
TECHNICAL MANUAL
Icona door entry monitor |
|
Art. 6601W - Art. 6601W/BM |
Passion.Technology. Design. |
Warning
Table of contents.............................................................................. |
2 |
Monitor description......................................................................... |
3 |
Soft-touch key activation......................................................................... |
4 |
Soft-touch key description...................................................................... |
4 |
Indicator LED description........................................................................ |
4 |
Technical specifications.................................................................. |
5 |
Installation........................................................................................ |
7 |
Mounting the Icona SBC monitor on flush-mounted box Art. 6117..... |
7 |
Wall-mounting (Art. 6620) / on 503 series box/round box..................... |
8 |
Connections..................................................................................... |
9 |
Variant: connection of call repetition device Art. 1122/A...................... |
9 |
Monitor configuration.................................................................... |
10 |
Standard configuration for soft-touch keys......................................... |
10 |
Activation/deactivation Doctor function.............................................. |
10 |
Activation/deactivation Hands-Free function...................................... |
10 |
Configuration of Main and Secondary internal units - DIP 8 of S2.... |
11 |
Power supply configuration and management - DIP 7 of S2.............. |
11 |
Advanced monitor configuration........................................................... |
12 |
Warning............................................................................................. |
12 |
Programming for intercom call.......................................................... |
12 |
Programming/deleting intercom address (selective intercom only) |
|
12 |
|
Programming buttons for intercom call...................................... |
13 |
Direct programming of intercom call.......................................... |
14 |
Programming keys for generic or coded actuator............................. |
15 |
Programming buttons for other functions......................................... |
16 |
Programming range........................................................................... |
17 |
LED/alarm/lock-release/actuator programming................................ |
18 |
Changing monitor ringtones.............................................................. |
19 |
Programming reset............................................................................ |
19 |
System performance and layouts................................................. |
19 |
2
The Icona series is comprised of hands-free monitors that can be used in “Building Kit” (exclusively 2-wire), Simplebus Top and Kit Video systems
•Article 6601W is a colour monitor equipped as standard with 9 function buttons and 6 adjustment buttons.
•Article 6601W/BM is a colour monitor equipped as standard with 9 buttons, 6 adjustment buttons and an induction loop.
1 |
2 |
3 |
4 |
|
5 |
|
11 |
|
|
10 |
6 |
|
7 |
|
|
|
|
|
|
8 |
B |
|
A |
|
|
9 |
|
1. Microphone
2. 4.3’’ LCD screen
3. Soft-touch keys/LED
4. Loudspeaker
5. S1 User code programming microswitches (see Addressing table)
6. CV1 CV2 remove in case of separate power supply.
7. CV5 Jumper for video closure. In systems with more than one monitor connected in cascade, only the monitor furthest away must have CV5 closed.
8.CV6
position A = contact IN1-IN2 > LED (default)
position B = contact CFP2-IN1 > ALARM/LOCK-RELEASE/ACTUATOR
9. S2 Microswitches for programming buttons and functions (marked with a red corner) DIP 1-2-3-4 for button function programming
DIP 5-6 access to programming
DIP 7 for management of power supply voltage, see “Power supply configuration and management”
DIP 8 for main and secondary monitor setting, see “Configuration of Main and Secondary internal unit”
10.M2 Terminal block for system connection: CFP1 CFP2 Floor door call input
S+ S- Call repetition device terminals IN1 IN2 LED input (programmable)
11.M1 Terminal block for system connection: L L Bus line connection terminals
- + Power supply terminals
3
Soft-touch key activation |
|
1 |
|
2 |
x2 |
|
ff Swipe to enable function key row (1). ff Swipe to enable function key row (2).
ff Press the desired key once to activate the function associated with it
Wait for approximately 1 sec. before pressing the same key again. Pressing the same key several times in quick succession will cancel the command
Audio key
Lock-release key
Keys 1-2-3-4-5 (programmable)
Self-ignition key (programmable)
Privacy key
Call volume key
Ringtone volume key
Value 'Up/Down' key
Contrast key
Brightness key
Audio LED
steady = audio enabled/hands-free function continuous flashing = call received
Lock-release LED
1 flash = confirm lock-release
4 flashes = programming successful
10 flashes = programming error continuous flashing = door open
Privacy LED - Doctor
4 flashes = device engaged slow flashing = programming
3 flashes (every 5 s.) = Doctor function enabled steady = privacy function enabled
The monitor Art. 6601W is designed for use in colour systems, in the SB2 section downstream of Art. 4888C, or in systems without mixer, such as the system with 2-wire KIT or Art. 1210.
4
MAIN SPECIFICATIONS |
6601W |
6601W/BM |
Flush-mounted |
Yes |
Yes |
Wall-mounted |
Yes |
Yes |
Desk base-mounted |
Yes |
Yes |
Hands-free function |
Yes |
Yes |
Induction loop |
/ |
Yes |
Type of display |
LCD |
LCD |
Display size (inches) |
4,3'' 16:9 |
4,3'' 16:9 |
Display resolution (H x V) |
480 x 272 |
480 x 272 |
B/W or colour display |
Colors |
Colors |
Product colour |
White RAL9003 |
White RAL9003 |
Sensitive Touch technology |
Yes |
Yes |
Total buttons |
15 |
15 |
COMPATIBILITY |
|
|
Simplebus Top audio/video system |
Yes |
Yes |
Building Kit audio/video system |
Yes |
Yes |
Kit audio/video system |
Yes |
Yes |
FUNCTIONS |
|
|
Actuator control function |
Yes |
Yes |
Self-ignition |
Yes |
Yes |
Switchboard call function |
Yes |
Yes |
Priority calls |
Yes |
Yes |
Intercom function |
Yes |
Yes |
Selective intercom call |
Yes |
Yes |
Call to multiple addresses |
Yes |
Yes |
Call to group addresses |
Yes |
Yes |
Call forwarding |
Yes |
Yes |
Privacy function |
Yes |
Yes |
Doctor |
Yes |
Yes |
Redial |
Yes |
Yes |
Floor door call function |
Yes |
Yes |
Electronic bell |
Yes |
Yes |
Customisable ringtone |
Yes |
Yes |
Privacy conversation function |
Yes |
Yes |
Key button function |
Yes |
Yes |
HARDWARE SPECIFICATIONS |
|
|
Removable terminals |
Yes |
Yes |
SETTINGS |
|
|
Loudspeaker volume control |
Yes |
Yes |
Microphone volume control |
Yes |
Yes |
Ringtone volume control |
Yes |
Yes |
Display brightness control |
Yes |
Yes |
Display contrast control |
Yes |
Yes |
5
GENERAL INFO |
6601W |
6601W/BM |
Product height (mm) |
147 |
147 |
Product width (mm) |
142,5 |
142,5 |
Product depth (mm) |
23 |
23 |
TECHNICAL SPECIFICATIONS |
|
|
Power supply voltage |
22÷28Vdc |
22÷28Vdc |
Operating temperature (°C) |
-5÷40 |
-5÷40 |
Relative humidity for operation |
25 - 75 % |
25 - 75 % |
Clamps |
L L - + CFP1 CFP2 S+ S- IN1 IN2 |
L L - + CFP1 CFP2 S+ S- IN1 IN2 |
6