This cooktop is for use with Natural Gas and Universal LPG
PCL985FAU PCR915B90A
PCN985FAU PCT915B90A
Robert Bosch Hausgeräte GmbH
Carl-Wery-Straße 34
81739 München
Cod. 9000198453 C
Internet:: http://www.bosch-hausgeraete.de
Dear customer,
We would like to thank and congratulate you for your choice. This practical modern appliance has been made using materials of the highest quality, which have been put through the strictest of Quality Controls during manufacture and meticulously tested to ensure that they meet all of your cooking demands. We kindly ask you to read and follow these simple instructions
in order to guarantee first-class results from the very start. This booklet contains important information not only concerning use, but also concerning your own personal safety and maintenance of the appliance.
Our products need to be carefully packed to protect them during transportation. All the material used for packing is considered essential for this purpose and is also completely recyclable. You too can contribut towards protecting the environment by disposing of this material at your nearest recyclable refuse collection point. Do not dispose of used cooking oil down the kitchen sink. Oil may seriously damage the environment. Dispose of it in a closed container at your nearest collection point or, failing this, dispose of it in your rubbish bin. Although this last solution is far from perfect, your oil will be taken to a controlled refuse dump where it will not be allowed to pollute water. You and your children will appreciate it. Render your old appliance useless before disposing of it at your nearest recyclable refuse collection centre.
Your local authority will be pleased to inform you where your nearest centre is.
2
CONTENT
Safety considerations |
4 |
For your safety |
4 |
What to do if yo smell gas |
4 |
Warnings |
4 |
Installation |
6 |
Preparing to install |
6 |
Clearances |
7 |
Installation of cooktop into Kitchen bench |
7 |
Installation procedure |
8 |
Connection |
9 |
Electrical connection |
9 |
Gas connection |
10 |
Conversion front Nat. Gas to Universal LPG |
11 |
To change injectors |
11 |
Injector size chart |
12 |
Minimum flame adjustment |
12 |
Operating instructions |
13 |
Burner location |
13 |
Burner ignition & control |
13 |
Wok burner operation |
14 |
User instructions |
17 |
Warnings concerning cooking |
17 |
Cleaning and maintenance |
18 |
Service |
19 |
Trouble shooting |
19 |
Wiring diagram |
20 |
Wiring diagram |
|
|
|
|
|
|
A |
|
|
|
C |
|
|
|
|
E |
|
|
|
|
|
|
B |
|
A. Switch |
|
|
|
|
B. Blue wire |
|
|
|
|
C. Brown wire |
C |
L |
N |
|
D. Terminal |
||||
|
||||
E. Ignition module |
|
|
D |
|
PCL985FAU |
|
PCN985FAU |
||
PCR915B90A |
|
PCT915B90A |
|
Robert Bosch Hausgeräte GmbH |
CIF: A-28-893550 |
|
|
Robert Bosch Hausgeräte GmbH |
CIF: A-28-893550 |
|||
|
|
|
|
|
|
|
|
|
|
|
E-Nr |
FD |
|
|
|
E-Nr |
|
FD |
|
|
|
|
|
|
|
|
|
|
|
|
Gas type |
NG |
U LPG |
|
|
|
Gas type |
NG |
U LPG |
|
Test point pressure (kPa) |
1,0 |
2,75 |
|
|
|
Test point pressure (kPa) |
1,0 |
2,75 |
|
Injectors sizes (mm) |
|
|
|
|
|
Injectors sizes (mm) |
|
|
|
LF |
1,55 |
0,85 |
|
|
|
LF |
1,65 |
0,93 |
|
LR |
0,90 |
0,50 |
|
|
|
LR |
0,90 |
0,50 |
|
RF |
1,18 |
0,67 |
|
|
|
RF |
1,65 |
0,93 |
|
RR |
1,18 |
0,67 |
|
|
|
RR |
1,18 |
0,67 |
|
C |
0,85/1,10 |
0,43/0,68 |
|
|
|
CF |
0,90 |
0,50 |
|
|
|
|
|
|
|
CR |
1,18 |
0,67 |
|
HGC (MJ) |
43,50 |
39,85 |
|
|||||
|
|
|
|
HGC (MJ) |
47,00 |
40,60 |
|||
|
Electrical compliance |
In compliance with AS 3100 |
|
|
|
|
|
|
|
|
|
|
|
Electrical compliance |
In compliance with AS 3100 |
||||
|
AGA approval number |
7127 |
|
|
|
AGA approval number |
|
7127 |
|
|
Preinstalled NG |
Made in Spain |
|
|
|
Preinstalled NG |
Made in Spain |
||
|
|
|
|
|
|
|
|
|
|
3 |
20 |