INSTALLATION INSTRUCTIONS

24" FLUSH MOUNT DEFLECTOR VENT: SKMD24F0AS / SKMD24F0AH

IMPORTANT NOTES TO THE INSTALLER

Read all of the Installation Manual that is included with the Microwave Drawer before installing in the flush mount configuration.

Observe all governing codes, ordinances, and safety instructions.

Be sure to leave these instructions with the consumer.

Parts includes:

Part

SKMD24F0AS

SKMD24F0AH

 

PREF-B019MRP0

PREF-B026MRP0

 

Flush Mount Deflector Vent (Stainless steel)

Flush Mount Deflector Vent (Dark gray)

 

Qty. 1

Qty. 1

 

LX-CZB055MRE0

LX-CZB073MRE0

 

Mounting screws (Stainless steel)

Mounting screws (Black)

 

Qty. 2

Qty. 2

1. Prepare cabinet opening as shown in Figures 1, 2A, 2B, 2C.

 

B

 

 

 

A

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

D

E

 

 

 

 

 

 

 

 

G

 

F

 

 

 

 

 

 

 

H

 

 

 

 

 

 

 

I

 

K

 

 

Note: the face of the shelf must

 

 

 

sit 1

3/4" (44.45 mm) back from

 

 

 

 

 

L

 

 

J

 

M

the face of the cabinet.

 

 

 

 

 

 

 

 

 

 

 

N

 

 

 

 

 

 

shelf face O

 

 

 

 

 

 

cabinet face

Figure 1

A.6" (152.40 mm)

B.Suggested electrical outlet location

C.Anti-Tip block

D.5" (127 mm)

E.3-1/2" (88.90 mm)

F.4" (101.60 mm)

G.24-3/16" (614.35 mm) minimum

24-1/2" (622.3 mm) maximum

H.14-13/16" (376.24 mm) to bottom of Anti-Tip block

I.1-1/16" (26.97 mm)

J.23-1/2" (596.90 mm) minimum depth

K.22-1/8" (561.97 mm)

L.1-3/4" (44.45 mm)

M.16-7/8" (428.62 mm) opening

N.Floor must support 100 lb (45.4 kg)

O.1-3/4" (44.45 mm)

Anti-Tip block

A

Mounting cleat

Drawer face

B

C

Cabinet

face

CL

Top view Note: the mounting surface of the finished cleat must sit 1 1/16" (26.97 mm) back from the face of the cabinet [pushing the face of the drawer out 1/4" (6.35 mm)].

A.22" (558.8 mm) mounting cleat opening width

B.1/4" (6.35 mm)

C.1-1/16" (26.97 mm)

Figure 2A

E 1

TINSEB541MRR4

 

No oven

Suggested electrical

A

 

outlet location

Anti-Tip block

 

B

 

C

Figure 2B

Front view

A.22-1/8" (561.97 mm) mounting cleat opening width

B.24-3/16" (614.35 mm) minimum

24-1/2" (622.3 mm) maximum flush opening width

C.3/4" (19.05 mm) shelf

Move oven location

 

downward for extended

 

countertops for better

 

viewing angle.

Anti-Tip

16 7/8"

block

 

(428.62 mm)

 

flush opening

3/4" (19.05 mm)

height

 

shelf

Front face of cabinet 1 3/4" (44.45 mm) front face of shelf

3.Place the drawer adjacent to the wall or cabinet opening. Plug the power supply cord into the electrical outlet.

4.Carefully guide the drawer into the prepared opening. Avoid contact with the sides of the cutout opening and also pinching the cord between the oven and the wall.

5.Slide the drawer all the way back until the mounting flanges touch the cleats mounted in the cabinet opening.

6.Openthedrawer.Usingthe4holesonthedrawerasatemplate, pre drill the cabinet using a 1/16” (1.57 mm) bit. See Figure 4.

Mounting

flange

Figure 4

7. Secure the drawer with the 4 screws supplied.

Figure 2C

Side view

2. Install deflector as shown in Figure 3A.

Shelf detail showing the deflector vent during installation.

Position deflector vent and mark holes. Pre drill using a 1/16" (1.57 mm) bit before mounting.

Figure 3A

Shelf detail showing the deflector vent installed.

Figure 3B

E 2