Omega Products CSi8DH Manual

5 (1)

Benchtop Digital Controllers

With Optional Embedded Ethernet Connectivity

Features

Universal

 

 

Input

and Dual 5

A

Control

 

 

Output!

CSi8DH, $685, shown smaller than actual size.

Thermocouple probe GKQSS-316U-12 sold separately. Visit omega.com/gkqin

CSi8DH Series

 

 

 

 

 

 

U Dual Display Standard, Indicates Both

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U Optional Embedded

Setpoint and Real-Time Process

Internet Connectivity

U Simple to Configure and Use

U Portable, Rugged Metal Benchtop

U Universal Inputs: Thermocouple, RTD,

Enclosure with Tilt Handle

Process Voltage/Current, and Strain

U Dual, Internal 5 A SSR Control Output

U Auxiliary Output to Drive

U Built Around OMEGA’s Award-Winning

Higher-Current SSRs

Series Controllers

U Totally Programmable

U High Quality

Color Displays, Standard

U 5-Year Warranty

U Optional RS232/485 Communications

U High Accuracy

U Operates from 90 to 240 Vac @ 50/60 Hz

P-89

Omega Products CSi8DH Manual

Just Hook Up Your Sensor, Plug In Your Heater, and You’re Ready to Go!

 

 

 

 

 

CSi8DH shown

 

 

 

 

 

 

 

smaller than

 

 

 

 

 

 

 

actual size.

 

 

 

 

 

 

 

The OMEGA® CSi8D is a 18 DIN size

 

 

 

 

(96 x 48 mm) digital panel controller

 

 

 

 

in a rugged benchtop metal enclosure

 

 

 

 

featuring the big iSeries

 

 

 

 

color-changing display. The digits

 

 

 

 

are twice the size of those of

 

 

 

 

typical 18 DIN panel meters. The

 

 

 

 

iSeries meters feature the only LED

 

Specifications

 

 

displays that can be programmed

 

 

 

to change color between Green,

 

Accuracy: See table on page P-92

 

 

Amber, and Red at any setpoint or

 

Resolution: 1°/0.1°; 10 µV process

 

 

alarm point. Other options include,

 

Temperature Stability:

 

 

serial communications, Modbus®,

 

RTD: 0.04°C/°C

 

 

and Ethernet.

 

Thermocouple: 25°C (77°F); cold-junction compensation of 0.05°C/°C

 

 

The universal temperature and

 

Process: 50 ppm/°C

 

 

 

NMRR: 60 dB

 

 

process instrument (model “i”)

 

 

 

 

CMRR: 120 dB

 

 

handles 10 common types of

 

 

 

 

A/D Conversion: Dual-slope

 

 

thermocouples, multiple RTDs,

 

 

 

 

Reading Rate: 3 samples per second

 

 

and several process (DC) voltage

 

 

 

 

Digital Filter: Programmable

 

 

and current ranges. Units can be

 

 

 

 

Display: 4-digit, 9-segment LED; 10.2 mm (0.40"): i32, i16, i16D, i8DV;

 

 

reconfigured in the field.

 

 

 

 

21 mm (0.83"): i8; 10.2 mm (0.40") and 21 mm (0.83"): i8DH; Red, Green, and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Amber, and programmable colors for process variable, setpoint and

 

 

 

 

 

 

 

temperature units

 

 

 

 

Patented

 

Input Types: Thermocouple, RTD, analog voltage, analog current

 

 

 

 

 

 

 

 

 

 

 

 

Thermocouple Lead Resistance: 100 Ω max

 

 

 

 

 

 

 

Thermocouple Type (ITS 90): J, K, T, E, R, S, B, C, N, L

 

 

 

 

 

 

 

RTD Input (ITS 68): 100/500/1000 Ω Pt sensor; 2-, 3- or 4-wire;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.00385 or 0.00392 curve

 

 

 

 

At Any

 

Voltage Input: 0 to 100 mV, 0 to 1 Vdc, 0 to 10 Vdc

 

 

 

 

 

Input Impedance: 10 MΩ for 100 mV, 1 MΩ for 1 or 10 Vdc

 

 

 

 

Setpoint

 

Current Input: 0 to 20 mA (5 Ω load)

 

 

 

 

 

 

 

Configuration: Single-ended

 

 

 

 

 

 

 

Polarity: Unipolar

 

 

 

 

 

 

 

Step Response: 0.7 s for 99.9%

 

 

 

 

 

 

 

Decimal Selection: None or 0.1 for temperature; None, 0.1, 0.01 or

 

 

 

 

 

 

 

0.001 for process

 

 

 

 

 

 

 

Control Output: Dual 5 A SSR (internal)

 

P

 

 

 

 

 

Setpoint Adjustment: -1999 to 9999 counts

 

 

 

 

 

 

Span Adjustment: 0.001 to 9999 counts

 

 

 

 

 

 

 

Offset Adjustment: -1999 to 9999

 

 

 

 

 

 

 

Network and Communications

 

 

Totally Programmable

 

Ethernet: Standards compliance IEEE 802.3 10 Base-T

 

 

 

Supported Protocols: TCP/IP, ARP, HTTPGET

 

 

Color Displays

 

RS232/RS422/RS485: Selectable from menu; both ASCII and Modbus protocol

 

 

The OMEGA® i/8, i/16, and i/32 are

 

selectable from menu; programmable 300 to 19.2K baud; complete programmable

 

 

 

setup capability; program to transmit current display, alarm status, min/max, actual

 

 

the first complete series of 18, 116, and

 

 

 

132 DIN process control instruments

 

measured input value and status

 

 

with totally programmable color

 

RS485: Addressable from 0 to 199

 

 

d i s p l a y s . T h e

 

Connection: DB9 connector on rear panel

 

 

display can be

 

General

 

 

programmed to

 

Power: 90 to 240 Vac, 50 to 60 Hz

 

 

change color at

 

 

 

 

any setpoint or

 

Note: Comes with 1 power cord rated for 120 Vac, POWER CORD-MOLDED. Additional

 

 

alarm point.

 

power cords for 230 Vac operation are available. See accessories table.

 

 

 

 

 

 

 

 

 

 