SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
OUTDOOR UNIT
No. OBB469
PARTS CATALOG
Wireless type
Models
MUZ-GC25VA - E1
MUZ-GC25VAH - E1
MUZ-GC35VA - E1
MUZ-GC35VAH - E1
CONTENTS
1. RoHS PARTS LIST ············································2
SERVICE MANUAL (OBH469)
MUZ-GC25VA
MUZ-GC25VAH
NOTE:
RoHS compliant products have <G> mark on the spec name plate.
1 RoHS PARTS LIST
MUZ-GC25VA MUZ-GC25VAH
1-1. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS
16 15
14
17 |
13 |
18
20 19
22 21
12 10 9
23 |
11 |
|
7 8
6
4 5
3
2
1
2
MUZ-GC25VA MUZ-GC25VAH
1-1. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS
Part number that is circled is not shown in the illustration.
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
RoHS
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
|
|
|
|
Symbol |
|
Q'ty/unit |
|
||
Part No. |
Part Name |
in Wiring |
|
|
|
Remarks |
|||
MUZ-GC25VA- |
E1 |
MUZ-GC25VAH- E1 |
|||||||
|
|
|
|
Diagram |
|
||||
|
|
|
|
|
|
|
|
||
E12 |
B72 |
521 |
GRILLE |
|
1 |
|
1 |
|
|
E12 |
B72 |
232 |
CABINET |
|
1 |
|
1 |
|
|
E12 |
B72 |
290 |
BASE |
|
1 |
|
|
|
|
E12 |
B84 |
290 |
BASE |
|
|
|
1 |
|
|
E12 |
B72 |
293 |
SEPARATOR |
|
1 |
|
|
|
|
E12 |
B84 |
293 |
SEPARATOR |
|
|
|
1 |
|
|
E12 |
928 |
900 |
COMPRESSOR |
MC |
1 |
|
1 |
KNB065FDTHC |
|
E12 |
065 |
506 |
COMPRESSOR RUBBER SET |
|
3 |
|
3 |
3RUBBERS/SET |
|
E12 |
927 |
661 |
STOP VALVE (GAS) |
|
1 |
|
1 |
{9.52 |
|
E12 |
927 |
662 |
STOP VALVE (LIQUID) |
|
1 |
|
1 |
{6.35 |
|
E12 |
B72 |
245 |
SERVICE PANEL |
|
1 |
|
1 |
|
|
E12 |
B72 |
233 |
BACK PANEL |
|
1 |
|
1 |
|
|
E12 |
931 |
961 |
4-WAY VALVE |
|
1 |
|
1 |
|
|
E12 |
927 |
640 |
EXPANSION VALVE |
|
1 |
|
1 |
|
|
E12 |
B84 |
079 |
THERMO HOLDER |
|
|
|
1 |
|
|
E12 |
B84 |
525 |
CONDENSER WIRE NET |
|
|
|
1 |
|
|
E12 |
B84 |
523 |
CONDENSER NET |
|
|
|
1 |
|
|
E12 |
B72 |
523 |
CONDENSER NET |
|
1 |
|
|
|
|
E12 |
A89 |
301 |
OUTDOOR FAN MOTOR |
MF |
1 |
|
1 |
RA6V21- |
|
E12 |
B72 |
501 |
PROPELLER |
|
1 |
|
1 |
|
|
E12 |
B72 |
515 |
MOTOR SUPPORT |
|
1 |
|
1 |
|
|
E12 |
B72 |
297 |
TOP PANEL |
|
1 |
|
1 |
|
|
E12 |
B82 |
630 |
OUTDOOR HEAT EXCHANGER |
|
1 |
|
1 |
|
|
E12 |
B84 |
526 |
DEFROST HEATER |
H |
|
|
1 |
|
|
E12 |
B84 |
381 |
HEATER PROTECTOR |
26H |
|
|
1 |
|
|
E12 |
B82 |
936 |
CAPILLARY TUBE |
|
1 |
|
1 |
{3.0O2.0O260 |
|
E12 |
927 |
493 |
EXPANSION VALVE COIL |
LEV |
1 |
|
1 |
|
3
MUZ-GC25VA MUZ-GC25VAH
1-2. OUTDOOR UNIT ELECTRICAL PARTS
7
8
6
9
5
1
4
2
3
Part number that is circled is not shown in the illustration.
No. |
RoHS |
|
1G
2G
3G
4G
5G
6G
7G
8G
9
G
G
10 G
11 G
|
|
|
|
Symbol |
Q'ty/unit |
|
|
Part No. |
Part Name |
in Wiring |
MUZ-GC25VA- E1 |
MUZ-GC25VAH- E1 |
Remarks |
||
|
|
|
|
Diagram |
|
||
|
|
|
|
|
|
|
|
E12 |
B72 337 |
REACTOR |
L61 |
1 |
1 |
|
|
E12 |
927 |
306 |
THERMISTOR SET |
RT61,RT62 |
1 |
1 |
DEFROST, DISCHARGE |
E12 |
B82 308 |
AMBIENT TEMPERATURE THERMISTOR |
RT65 |
1 |
1 |
|
|
E12 |
B72 490 |
R.V. COIL |
21S4 |
1 |
1 |
|
|
E12 |
735 |
241 |
FUSE HOLDER |
|
1 |
1 |
|
E12 |
735 |
382 |
FUSE |
F61 |
1 |
1 |
T20AL250V |
E12 |
573 |
375 |
TERMINAL BLOCK |
TB1 |
1 |
1 |
3P |
E12 |
927 |
374 |
TERMINAL BLOCK |
TB2 |
1 |
1 |
3P |
E12 |
B82 |
451 |
INVERTER P.C. BOARD |
|
1 |
|
Including heat sink and RT64 |
E12 |
B84 |
451 |
INVERTER P.C. BOARD |
|
|
1 |
Including heat sink and RT64 |
E12 |
127 |
382 |
FUSE |
F701,F801 |
1 |
1 |
T3.15AL250V |
E12 |
661 |
385 |
VARISTOR |
NR61,NR62,NR63 |
1 |
1 |
|
4