Mitsubishi electric MSZ-FD50VA, MUZ-FD50VA User Manual [ru]

0 (0)

SPLIT-TYPE AIR CONDITIONERS

INDOOR UNIT

MSZ-FD50VA

MSZ-FD50VAS

OPERATING INSTRUCTIONS

For user

To use this unit correctly and safely, be sure to read these operating instructions before use.

BEDIENUNGSANLEITUNG

For den Anwender

Für einen sicheren und ordnungsgemäßen Gebrauch des Geräts unbedingt diese Bedienungsanleitung vor der Inbetriebnahme durchlesen.

NOTICE D’UTILISATION

A l’attention des clients

Pour avoir la certitude d’utiliser cet appareil correctement et en toute sécurité, veuillez lire cette notice d’instructions avant de mettre le climatiseur sous tension.

BEDIENINGSINSTRUCTIES

Voor de klant

Om dit apparaat correct en veilig te kunnen gebruiken moet u deze bedieningsinstructies voor gebruik eerst doorlezen.

MANUAL DE INSTRUCCIONES

Para los clientes

Para utilizar esta unidad de forma correcta y segura, lea previamente estas instrucciones de funcionamiento.

LIBRETTO D’ISTRUZIONI

Per gli utenti

Per utilizzare correttamente ed in tutta sicurezza questo apparecchio, leggere il presente libretto d’istruzioni prima dell’uso.

ΟΔΗΓΙΕΣ ΛΕΙΤΟΥΡΓΙΑΣ

Για το χρήστη

Για να χρησιμοποιήσετε αυτή τη μονάδα σωστά και με ασφάλεια, βεβαιωθείτε ότι έχετε διαβάσει αυτό το εγχειρίδιο οδηγιών πριν από τη χρήση.

INSTRUÇÕES DE OPERAÇÃO

Para o utilizador

Para utilizar esta unidade correctamente e com segurança, certifiquese de que lê estas instruções de operação antes da utilização.

BETJENINGSVEJLEDNING

Til kunden

Læs denne betjeningsvejledningen før brug, så enheden bruges korrekt og sikkert.

BRUKSANVISNING

För användaren

Läs bruksanvisningen innan enheten tas i bruk så att den används säkert och på rätt sätt.

ÇALIŞTIRMA TALİMATLARI

Kullanıcı için

Bu üniteyi doğru ve güvenli bir biçimde kullanmak için, kullanmadan önce bu işletim talimatlarını okuduğunuzdan emin olun.

ИНСТРУКЦИИ ПО ЭКСПЛУАТАЦИИ

Для пользователя

В целях правильной и безопасной эксплуатации данного устройства обязательно перед его использованием прочтите настоящее руководство по эксплуатации.

English

Deutsch

Français

Nederlands

Español

Italiano

Ελληνικά

Português

Dansk

Svenska

Türkçe

Русский

● OPERATING INSTRUCTIONS ●

CONTENTS

 

 

 

N SAFETY PRECAUTIONS

1

 

 

 

 

N DISPOSAL

2

 

 

 

 

N NAME OF EACH PART

3

 

 

 

 

N PREPARATION BEFORE OPERATION

3

 

 

 

 

N AREA SETTING

4

 

 

 

 

N SELECTING OPERATION MODES

5

 

 

 

 

N FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT

6

 

 

 

 

N ECONO COOL OPERATION

7

 

 

 

 

N TIMER OPERATION (ON/OFF TIMER)

7

 

 

 

 

NNPLASMA OPERATION

7

 

 

 

 

NNCLEAN OPERATION

7

 

 

 

 

N CLEANING

8

 

 

 

 

N WHEN YOU THINK THAT TROUBLE HAS OCCURRED

9

 

 

 

 

N WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME

10

 

 

 

 

N INSTALLATION PLACE AND ELECTRICAL WORK

10

 

 

 

 

 

N SPECIFICATIONS

10

 

 

 

 

 

 

 

SAFETY PRECAUTIONS

Since rotating parts and parts which could cause an electric shock are used in this product, be sure to read these “Safety Precautions” before use.

Since the cautionary items shown here are important for safety, be sure to observe them.

After reading this manual, keep it together with the installation manual in a handy place for easy reference.

Marks and their meanings

WARNING : Incorrect handling could cause serious hazard, such as death, serious injury, etc. with a high probability.

CAUTION : Incorrect handling could cause serious hazard depending on the conditions.

WARNING

Do not connect the power cord to an intermediate point, use an extension cord, or connect multiple devices to a single AC outlet.

• This may cause overheating, fi re, or electric shock.

Make sure the power plug is free of dirt and insert it securely into the outlet.

• A dirty plug may cause fi re or electric shock.

Do not bundle, pull, damage, or modify the power cord, and do not apply heat or place heavy objects on it.

• This may cause fi re or electric shock.

Do not turn the breaker OFF/ON or disconnect/connect the power plug during operation.

This may create sparks, which can cause fi re.

After the indoor unit is switched OFF with the remote controller, make sure to turn the breaker OFF or disconnect the power plug.

Do not expose your body directly to cool air for a prolonged length of time.

• This could be detrimental to your health.

The unit should not be installed, relocated, disassembled, altered, or repaired by the user.

An improperly handled air conditioner may cause fi re, electric shock, injury, or water leakage, etc. Consult your dealer.

If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent in order to avoid a hazard.

When installing, relocating, or servicing the unit, make sure that no substance other than the specifi ed refrigerant (R410A) enters the refrigerant circuit.

Any presence of foreign substance such as air can cause abnormal pressure rise and may result in explosion or injury.

The use of any refrigerant other than that specified for the system will cause mechanical failure, system malfunction, or unit breakdown. In the worst case, this could lead to a serious impediment to securing product safety.

Meanings of symbols used in this manual

: Be sure not to do.

: Be sure to follow the instruction.

: Never insert your fi nger or stick, etc.

: Never step onto the indoor/outdoor unit and do not put anything on them.

: Danger of electric shock. Be careful.

: Be sure to disconnect the power supply plug from the power outlet.

: Be sure to shut off the power.

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the appliance.

Do not insert your finger, a stick, or other objects into the air inlet or outlet.

• This may cause injury, since the fan inside rotates at high speeds during operation.

In case of an abnormal condition (such as a burning smell), stop the air conditioner and disconnect the power plug or turn the breaker OFF.

A continued operation in the abnormal state may cause a malfunction, fi re, or electric shock. In this case, consult your dealer.

When the air conditioner does not cool or heat, there is a possibility of refrigerant leakage. In this case, consult your dealer. If a repair involves recharging the unit with refrigerant, ask the service technician for details.

The refrigerant used in the air conditioner is safe. Normally, it does not leak. However, if refrigerant leaks and comes in contact with a heat source such as a fan heater, kerosene heater, or cooking stove, it will create a harmful gas.

The user should never attempt to wash the inside of the indoor unit. Should the inside of the unit require cleaning, contact your dealer.

Unsuitable detergent may cause damage to plastic material inside the unit, which may result in water leakage. Should detergent come in contact with electrical parts or the motor, it will result in a malfunction, smoke, or fi re.

CAUTION

Do not touch the air inlet or the aluminum fi ns of the indoor/ outdoor unit.

• This may cause injury.

Do not use insecticides or fl ammable sprays on the unit.

• This may cause a fi re or deformation of the unit.

En-1

SAFETY PRECAUTIONS

CAUTION

Do not expose pets or houseplants to direct airflow.

• This may cause injury to the pets or plants.

Do not place other electric appliances or furniture under the indoor/outdoor unit.

Water may drip down from the unit, which may cause damage or malfunction.

Do not leave the unit on a damaged installation stand.

• The unit may fall and cause injury.

Do not step on an unstable bench to operate or clean the unit.

• This may cause injury if you fall down.

Do not pull the power cord.

This may cause a portion of the core wire to break, which may cause overheating or fi re.

Do not charge or disassemble the batteries, and do not throw them into a fire.

This may cause the batteries to leak, or cause a fi re or explosion.

Do not operate the unit for more than 4 hours at high humidity (80% RH or more) and/or with windows or outside door left open.

This may cause the water condensation in the air conditioner, which may drip down, wetting or damaging the furniture.

The water condensation in the air conditioner may contribute to growth of fungi, such as mold.

Do not use the unit for special purposes, such as storing food, raising animals, growing plants, or preserving precision devices or art objects.

This may cause deterioration of quality, or harm to animals and plants.

Do not expose combustion appliances to direct airflow.

• This may cause incomplete combustion.

Never put batteries in your mouth for any reason to avoid accidental ingestion.

• Battery ingestion may cause choking and/or poisoning.

Before cleaning the unit, switch it OFF and disconnect the power plug or turn the breaker OFF.

• This may cause injury, since the fan inside rotates at high speeds during operation.

When the unit will be unused for a long time, disconnect the power plug or turn the breaker OFF.

The unit may accumulate dirt, which may cause overheating or fi re.

Replace all batteries of the remote controller with new ones of the same type.

Using an old battery together with a new one may cause overheating, leakage, or explosion.

If the battery fluid comes in contact with your skin or clothes, wash them thoroughly with clean water.

If the battery fl uid comes in contact with your eyes, wash them thoroughly with clean water and immediately seek medical attention.

Ensure that the area is well-ventilated when the unit is operated together with a combustion appliance.

• Inadequate ventilation may cause oxygen starvation.

Turn the breaker OFF when you hear thunder and there is a possibility of a lightning strike.

• The unit may be damaged if lightning strikes.

After the air conditioner is used for several seasons, perform inspection and maintenance in addition to normal cleaning.

Dirt or dust in the unit may create an unpleasant odor, contribute to growth of fungi, such as mold, or clog the drain passage, and cause water to leak from the indoor unit. Consult your dealer for inspection and maintenance, which require specialized knowledge and skills.

DISPOSAL

To dispose of this product, consult your dealer.

Note:

This symbol mark is for EU countries only.

This symbol mark is according to the directive 2002/96/ EC Article 10 Information for users and Annex IV, and/ or to the directive 2006/66/EC Article 20 Information for end-users and Annex II.

Fig. 1

Do not operate switches with wet hands.

This may cause electric shock.

Do not clean the air conditioner with water or place an object that contains water, such as a fl ower vase, on it.

This may cause fi re or electric shock.

Do not step on or place any object on the outdoor unit.

• This may cause injury if you or the object falls down.

IMPORTANT

Dirty fi lters cause condensation in the air conditioner which will contribute to the growth of fungi such as mold. It is therefore recommended to clean air filters every 2 weeks.

For installation

WARNING

Consult your dealer for installing the air conditioner.

It should not be installed by the user since installation requires specialized knowledge and skills. An improperly installed air conditioner may cause water leakage, fi re, or electric shock.

Provide a dedicated power supply for the air conditioner.

A non-dedicated power supply may cause overheating or fi re.

Do not install the unit where fl ammable gas could leak.

If gas leaks and accumulates around the outdoor unit, it may cause an explosion.

Earth the unit correctly.

Do not connect the earth wire to a gas pipe, water pipe, lightning rod, or a telephone ground wire. Improper earthing may cause electric shock.

CAUTION

Install an earth leakage breaker depending on the installation location of the air conditioner (such as highly humid areas).

If an earth leakage breaker is not installed, it may cause electric shock.

Ensure that the drain water is properly drained.

If the drain passage is improper, water may drip down from the indoor/ outdoor unit, wetting and damaging the furniture.

In case of an abnormal condition

Immediately stop operating the air conditioner and consult your dealer.

Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and/or reused.

This symbol means that electrical and electronic equipment, batteries and accumulators, at their end-of-life, should be disposed of separately from your household waste.

If a chemical symbol is printed beneath the symbol (Fig.1), this chemical symbol means that the battery or accumulator contains a heavy metal at a certain concentration. This will be indicated as follows:

Hg: mercury (0,0005%), Cd: cadmium (0,002%), Pb: lead (0,004%)

In the European Union there are separate collection systems for used electrical and electronic products, batteries and accumulators.

Please, dispose of this equipment, batteries and accumulators correctly at your local community waste collection/recycling centre.

Please, help us to conserve the environment we live in!

En-2

Mitsubishi electric MSZ-FD50VA, MUZ-FD50VA User Manual

● OPERATING INSTRUCTIONS ●

NAME OF EACH PART

Indoor unit

Remote controller

Display section

 

Operation

Remote control

receiving section

indicator

 

lamp

Operation display

 

 

section

Signal transmitting section

Distance of signal : About 6 m

Beep(s) is (are) heard from the indoor unit when the signal is received.

Front panel

Air fi lter

Air inlet

Plasma

deodorizing

fi lter

Plasma electrode unit

Page 7

Plasma

 

 

anti-allergy

i-see sensor Page 4

 

enzyme fi lter

 

 

 

Air outlet

 

 

Fan guard

Heat

Emergency

Fan

exchanger

operation

Horizontal vane

Vertical vane

switch Page 5

Outdoor unit

 

 

 

 

Air inlet (back and side)

 

Piping

 

 

Drainage hose

 

Air outlet

Drain outlet

Outdoor units may be different in appearance.

ON/OFF

(operate/stop) button

Operation select button Page 5

FAN speed control button

Page 6

ECONO COOL button Page 7

PLASMA button

Page 7

VANE control button

Page 6

CLEAN button

Page 7

Lid Slide down to open

Temperature buttons

Page 5

Off-timer button Page 7

On-timer button Page 7

WIDE VANE button Page 6

TIME set buttons Pages 3, 7 Increase time

Decrease time

AREA button Page 4

CLOCK button Page 3

RESET button Page 3

i-see button Page 4

Remote controller

holder

Install the remote controller holder in a place where the signal can be received by the indoor unit.

Only use the remote controller provided with the unit. Do not use other remote controllers.

If two or more indoor units are installed in proximity to one another, an indoor unit that is not intended to be operated may respond to the remote controller.

PREPARATION BEFORE OPERATION

Before operation: Insert the power supply plug into the power outlet and/or turn the breaker on.

Installing the remote controller batteries

Be sure to set the installation position before installing the batteries. Page 4

4. Press RESET

1. Remove the front lid

2. Insert AAA alkaline batteries

3. Install the front lid

Make sure the polarity of the batteries is correct.

Do not use manganese batteries and leaking batteries. The remote controller could malfunction.

Do not use rechargeable batteries.

Replace all batteries with new ones of the same type.

Batteries can be used for approximately 1 year. However, batteries with expired shelf lives last shorter.

Press RESET gently using a thin instrument.

If the RESET button is not pressed, the remote controller may not operate

Setting current time

1. Press CLOCK

 

2. Press the TIME buttons to set the

3. Press CLOCK again

time.

Each press increases/decreases

the time by 1 minute (10 minutes

 

when pressed longer)

• Press CLOCK gently using a thin instrument.

En-3

PREPARATION

BEFORE OPERATION

Setting the installation position

Be sure to set the slide switch inside the remote controller in accordance with the installed position of the indoor unit.

Installation position:

Left:

Distance to objects (wall, cabinet, etc.) is less than 50 cm to the left

Center:

Distance to objects (wall, cabinet, etc.) is more than 50 cm to the left

 

and right

Right:

Distance to objects (wall, cabinet, etc.) is less than 50 cm to the right

(Left)

(Center)

(Right)

 

Slide switch

Area

 

Left

Center

Right

Slide switch

 

 

 

 

Remote controller display

Press

to activate i-see control operation.

• Press gently using a thin instrument.

 

 

lights. (Operation display section)

 

 

• The default setting is “active”.

 

 

Press

again to release i-see control operation.

i-see control operation

 

 

The sensors constantly measure the room and

Room

 

fl oor/wall temperature to automatically adjust to

Floor/wall

the set temperature by estimating the tempera-

temperature

temperature

ture actually perceived by a person inside the

30.9%

43.7%

room (“sensible temperature”).

Humidity

20.7%

i-see sensor

When the AREA setting is not activated, the sensing range of the i-see sensor differs depending on the installation location of the air conditioner.

Installation position

Left

Center

Right

Sensing range

Note:

Do not touch the i-see sensor. This may cause malfunction of the i-see sensor.

AREA SETTING

Press to select AREA. Each press changes AREA in the following order:

Cancel

(AUTO)

(Left)

(Right)

*1

The i-see control operation has to be active to select AREA.

Horizontal airflow direction cannot be selected when AREA is

set.

. Page 6

*1 Horizontal airflow direction set by

Press until “Cancel” is selected to release AREA setting.

• Pressing also releases AREA setting.

Area

(AUTO) ....The i-see sensor detects temperature disparities, efficiently cooling/heating the whole room.

In COOL mode:

Daytime

Nighttime

Warm area

Cold area

(LEFT) / (RIGHT)

Select the desired area to be air conditioned.

Indoor unit display

Horizontal airfl ow direction:

Left

Center or Swing

Right

 

Lighted

Not lighted

En-4

● OPERATING INSTRUCTIONS ●

SELECTING OPERATION MODES

1 Press

to start the operation.

2Press to select operation mode. Each press changes mode in the following order:

(AUTO) (COOL) (DRY) (HEAT)

3Press or to set the temperature.

Each press raises or lowers the temperature by 1°C.

Press to stop the operation.

• The same setting is selected the next time by simply pressing .

Multi system operation

Two or more indoor units can be operated by one outdoor unit. When several indoor units are operated simultaneously, cooling and heating operations cannot be done at the same time. When COOL is selected with one unit and HEAT with another or vice versa, the unit operated later becomes standby mode. The power lamp blinks (display section).

AUTO mode (Auto change over)

The unit selects the operation mode according to the difference between the room temperature and the set temperature. During AUTO mode, the unit changes mode (COOL↔HEAT) when the room temperature is 2°C away from the set temperature for more than 15 minutes.

Note:

Multi system operation

Two or more indoor units can be operated by one outdoor unit. When several indoor units are operated simultaneously, the unit may not be able to switch operation mode between COOL and HEAT. In this case, the indoor unit becomes standby mode.

COOL mode

Enjoy cool air at your desired temperature.

Note:

Do not operate COOL mode at very low outside temperatures (less than -10°C). Water condensed in the unit may drip and wet or damage furniture, etc.

DRY mode

Dehumidify your room. The room may be cooled slightly. Temperature cannot be set during DRY mode.

HEAT mode

Enjoy warm air at your desired temperature.

Emergency operation

When the remote controller cannot be used...

Emergency operation can be activated by pressing the emergency operation switch (E.O.SW) on the indoor unit.

Each time the E.O.SW is pressed, the operation changes in the following order:

Operation indicator lamp

Emergency COOL

Emergency HEAT

Set temperature : 24°C

Stop Fan speed : Medium

Horizontal vane : Auto

Note:

The fi rst 30 minutes of operation is test run. Temperature control does not work, and fan speed is set to High.

Auto restart function

If a power failure occurs or the main power is turned off during operation, “Auto restart function” automatically starts operation in the same mode as the one set with the remote controller just before the shutoff of the main power. When timer is set, timer setting is cancelled and the unit starts operation when power is resumed.

If you do not want to use this function, please consult the service representative because the setting of the unit needs to be changed.

En-5

FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT

Press to select fan speed. Each press changes fan speed in the following order:

 

 

 

 

 

 

 

 

 

 

 

 

(AUTO) (Low)

 

(Med.)

 

(High) (Super High)

 

 

 

 

 

 

 

 

 

 

 

Two short beeps are heard from the indoor unit when set to AUTO.

Use (Super High) to cool/heat the room more efficiently. It is recommended to lower the fan speed once the room is cool/warm.

If the operating sound of the air conditioner disturbs your sleep, use

(Low).

Press to select vertical airfl ow direction. Each press changes airfl ow direction in the following order:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(AUTO)

(1)

(2)

(3)

(4)

(5)

(SWING)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Two short beeps are heard from the indoor unit when set to AUTO.

Press to select horizontal airfl ow direction. Each press changes airfl ow direction in the following order:

Vertical airflow direction

(AUTO)

The vane is set to the most efficient airflow direction. COOL/DRY:horizontal position. HEAT:downward position.

(Manual)

For efficient air conditioning, select upper position for COOL/DRY, and lower position for HEAT. During COOL/DRY, when the vane is set to position (4) or (5), the vane automatically moves to horizontal position after 1 hour to prevent any condensation from dripping.

(Swing)

The vane moves up and down intermittently.

(SWING)

En-6

● OPERATING INSTRUCTIONS ●

ECONO COOL OPERATION PLASMA OPERATION

Press during COOL mode page 5 to start ECONO COOL operation.

The unit performs swing operation vertically in various cycle according to the temperature of the unit. Set temperature is set 2°C higher automatically.

Press again to cancel ECONO COOL operation.

ECONO COOL operation also is canceled when the VANE button is pressed.

What is “ECONO COOL”?

Swing air fl ow (change of air fl ow) makes you feel cooler than constant air fl ow. So, even though the set temperature is automatically set 2°C higher, it is possible to perform cooling operation with keeping comfort. As a result, energy can be saved.

TIMER OPERATION (ON/OFF TIMER)

1 Press

or

during operation to set the timer.

(ON timer) : The unit turns ON at the set time.

(OFF timer) : The unit turns OFF at the set time.

* or blinks.

*Make sure that the current time is set correctly. Page 3

2 Press

(Increase) and

(Decrease) to set the

time of timer.

 

Each press increases or decreases the set time by 10 minutes.

3 Press

or

again to cancel timer.

Note:

ON and OFF timers can be set together. mark indicates the order of timer operations.

If power failure occurs while ON/OFF timer is set, see page 5 “Auto restart function”.

Press to start PLASMA operation.

• PLASMA lamp turns on. (Display section)

Press again to cancel PLASMA operation.

What is “PLASMA operation”?

Plasma operation consists of deodorizing and air purifying features.

Particles of odor-releasing substances are absorbed and decomposed by the plasma deodorizing fi lter. Particles of allergens such as pollens and house dust are collected by the plasma anti-allergy fi lter. These fi lters work with negative ions generated by the plasma electrode unit.

CLEAN OPERATION

Press

to activate CLEAN operation.

The unit performs CLEAN operation when it is stopped with the button or OFF timer after COOL/DRY operation. CLEAN lamp turns on. (Display section)

CLEAN operation is not performed when: COOL is operated less than 3 minutes/ DRY is operated less than 6 minutes.

Press again to deactivate CLEAN operation.

• Pressing does not deactivate CLEAN operation.

What is “CLEAN operation”?

CLEAN operation function helps to keep the unit clean and prevents mold growth by generating small amount of ozone (*1) and performing FAN operation for about 40 minutes. It is recommended to keep CLEAN operation active at all times. *1 About 0.01 ppm at the air outlet. This is the same level found in nature, such as in forests, and there is no effect on the human body.

Note:

Fan is stopped for the fi rst 15 minutes of CLEAN operation.

During multi system operation, air from the unit may become warm. In this case, CLEAN operation is cancelled automatically to prevent undesirable rise in room temperature.

En-7

Loading...
+ 16 hidden pages