4 (1)

FEATURES

24-hour programme

Independent heating and hot water channels

One or Two ON/OFF periods per day

Built-in programme

Temporary programme override/advance

7-day battery back-up

Compact size

AM/PM or 24 hour clock format (factory option)

ST699

ELECTRONIC DUAL

ZONE TIMER

PRODUCT DATA

The ST699 electronic dual zone timer is used to control gravity, primary or fully pumped central heating systems requiring a single 24 hour programme with two ON/OFF periods per day.

ST699 incorporates a simple and intuitive programming concept which established its predecessor as the leading electronic dual zone timer on the market.

ST699 is designed for European CEN approval.

Wallplate compatibility with 7-day version (ST799)

10 minute programme resolution

3 A resistive/inductive (@ 0.6 pf) 230 V~ SPDT relay rating

Simple/intuitive programming

Surface or wallbox mounting options

Pack contains everything for immediate installation

EN0R 8439 R0

Honeywell ST699 Manual

ST699 ELECTRONIC DUAL ZONE TIMER

SPECIFICATIONS

Product type

: Electronic dual zone timer

Power supply

: 230 V~ (±10%), 50 HZ

Power reserve : Rechargeable battery with 7 days

 

backup following a 24 hour charging

 

period

Switch rating

: 2 x SPDT potential free

 

3 A resistive @ 230 V~ (± 10%), 50 Hz

 

3 A inductive @ 0.6 pf

Programme

: 24-hour with two ON/OFF periods daily

Programme

: 10 minutes

resolution

 

Programme day : 03.00 AM to 02.50 AM (on the next day)

Override

:

Advance next programme time

 

 

(change)

Wiring

:

Surface or single wallbox (UA1 size)

Wiring access : Rear or bottom edge (surface wiring access)

Wire gauge : 0.75 to 2.5 mm2 two max. per terminal Dimensions : 100 x 100 x 38 mm (w x h x d) Protection class : IP20 (IEC 529)

Environmental : Operating temperature range 0 to 45oC

 

Shipping and storage temperature

 

range -20 to 55oC

 

Humidity range 0 to 90% rh, non-

 

condensing

Approvals

: Designed to meet European CEN

 

approval EN60730

Life

: 7 years minimum

DIMENSIONS

ORDERING SPECIFICATION

 

ST699B1002

 

 

 

INSTALLATION

Mounting

Remove the subbase from the timer by depressing the securing clip A and pulling the two halves apart. See fig. 1

The ST699 can either be mounted onto the wall surface or a flush mounted UA1 (with 60.3 mm pitch mounting holes) using the screws supplied.

IMPORTANT

1.The installer must be a trained service engineer

2.Disconnect the power supply before beginning installation

Fig. 1