Dometic RM2354, DM2663, DM2652, RM2554, DM2862 INSTALLATION

...
0 (0)

®

RM2351 RM2554 DM2862 RM2354 DM2652 DM3862 RM2451 DM2662 NDM1062 RM2454 DM2663 NDR1292 RM2551 DM2852

FOR YOUR SAFETY

If you smell gas:

1.Open windows.

2.Don’t touch electrical switches.

3.Extinguish any open flame.

4.Immediately call your gas supplier.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

installation manual

Refrigerator for LP-gas & electric operation

Pour votre sécurité

Si vous sentez une odeur de gaz:

1.Ouvrez les fenêtres.

2.Ne touchez à aucun interrupteur.

3.Éteignez toute flamme nue.

4.Avertissez immédiatement votre fournisseur de gaz.

Pour votre sécurité

Ne pas entreposer ni utiliser de l’essence ni d’autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil.

!

WARNING

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier.

! AVERTISSEMENT

Une installation, un réglage, une modification, une réparation ou un entretien non conforme aux normes peut entraîner des blessures ou des dommages matériels.

Lisez attentivement le mode d’emploi fourni avec l’appareil. Pour obtenir de l’aide ou des renseignements supplémentaires, consultez un installateur ou un service d’entretien qualifié ou le fournisseur de gaz.

®

USA

Corporate Office

CANADA

Service Office

2320 Industrial Parkway Elkhart, IN 46515

Dometic Corporation

Dometic Corporation

 

48 Zatonski, Unit 3

2320 Industrial Pkwy.

For Service Center Assistance

Brantford, ON N3T 5L8

Elkhart, IN 46516

CANADA

Phone: 574-294-2511

Call: 800-544-4881

Phone: 519-720-9578

 

 

 

825125806

 

MO-M 0724

(French 825125850)

 

 

©2006-2007 Dometic Corporation

LaGrange, IN 46761

introduction

This manual describes the installation procedure of RM2351, RM2354, RM2451, RM2454, RM2551, RM2554, DM2652, DM2662, DM2663, DM2852, DM2862, DM3862, NDM1062 and NDR1292.

The installation is to be performed by qualified personnel only and must conform to all relevant local authorities. Please read this manual thoroughly before installing the refrigerator. To ensure safe and efficient operation, the refrigerator must be installed as described in this manual. Be aware of possible safety hazards when seeing alert symbols on the refrigerator as well as in this manual.

For information about maintenance and operating instructions, refer to the User manual.

contents

Certification and Code Requirements_______ 4

Ventilation requirements__________________ 4

General information.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Ventilation heights.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Clearances .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Overall and recess dimensions.. . . . . . . . . . . . . . . . . . . . . . . . . 6

installation instructions__________________ 7

mounting instructions ____________________ 11

Reversing the door swing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Mounting the door panel(s). . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

refrigerator removal_____________________ 12 appendix A - rearview equipment___________ 13 appendix B - wiring diagrams_______________ 16

Installing the refrigerator .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Securing the refrigerator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Symbols

The following symbols are used throughout the manual:

!

WARNING

Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury.

! CAUTION

CAUTION

Indicates a potentially hazardous situation, which, if not avoided, may result in minor or moderate injury.

Used without the safety alert symbol indicates, a potentially hazardous situation which, if not avoided may result in property damage.

Information

Step-by-step instructions

- -

Certification and Code Requirements

This appliance is certified under the latest edition of ANSI Z21.19•CSA 1.4 Refrigerators using gas fuel. The installation must conform with local codes, or in absence of local codes, the following standards as applicable.

In the U.S. the installation must conform with:

National Fuel Gas Code, ANSI Z223.1/NFPA 54

(latest edition).

Recreational Vehicles Code, ANSI A119.2 (latest edition).

Manufactured Home Construction and Safety Standard, Title

24 CFR, Part 3280.

If an external electrical source is utilized, the refrigerator, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, the National Electrical Code, ANSI/NFPA 70 - (latest edition).

In CANADA, the installation must conform with:

Natural Gas and Propane Installation Code, CSA B149.1

CSA Z240 RV Series, Recreational Vehicles.

Current CSA Z240.4, Gas-equipped Recreational Vehicles and Mobile Housing.

If an external electrical source is utilized, the refrigerator, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, the Canadian

Electrical Code, CSA C22.1, Parts I and II - (latest edition).

Ventilation requirements

General information

Ventilation is one of the requirements for proper cooling unit operation. The installation should be made in such a manner as to separate the combustion system from the living space of the mobile home or recreational vehicle. Openings for air supply or for venting of combustion products should have a minimum dimension of not less than 1/4 inch.

Proper installation requires one lower fresh air intake and one upper exhaust vent. Certified installations require one roof vent and one lower side vent. The ventilation kits shown in this manual have been certified for use with the different models as displayed in the “Certified Vent System Kits” table.

The ventilation kits must be installed and used without modification! An opening toward the outside at floor level in the refrigerator compartment has to be provided for ventilation of heavier-than-air fuel gases. The lower vent of the recommended kits is provided with proper size openings. The flow of combustion and ventilating air must not be obstructed.

CAUTION

It is of especially importance that the airflow around the burner housing, the boiler insulation and the flow of combustion gases must not be obstructed. Items placed in the vicinity of the refrigerator compartment accordingly must be secured away from the refrigerator tubing and flue.

The lower side vent is fitted with a panel, which provides an adequate access opening for ready serviceability of the burner and control manifold of the refrigerator. This should be centered on the back of the refrigerator.

Certified Vent System Kits

Model

Kit

Components

Part no..

No..

RM2351

2A

Roof Base

3103633.XXX* or 3310893.XXX*

RM2354

 

Roof Cover

3103634.XXX* or 3310894.XXX*

 

 

Lower Side Vent

3109350.XXX*

 

 

Lower Side Vent

RM183

 

3A

Upper Side Vent

RM123A

 

 

Lower Side Vent

RM183

 

 

PowerVentAss’y

3108705.751**

 

 

Upper Side Vent

RM123A

 

 

Upper Side Vent

3109492.003

 

 

Lower Side Vent

RM183

 

 

Lower Side Vent

3109492.003

 

 

 

 

RM2451

3A

Roof Base

3103633.XXX* or 3310893.XXX*

RM2454

 

Roof Cover

3103634.XXX* or 3310894.XXX*

RM2551

 

Lower Side Vent

3109350.XXX*

RM2554

 

 

 

DM2652

4A

Roof Base

3103633.XXX* or 3310893.XXX*

DM2662

 

Roof Cover

3103634.XXX* or 3310894.XXX*

DM2663

 

Lower Side Vent

3109350.XXX*

DM2852

 

 

 

DM2862

 

 

 

DM3862

 

 

 

NDM1062

 

 

 

ndr1292

5A

Roof Base

3103633.XXX* or 3310893.XXX*

 

 

Roof Cover

3103634.XXX* or 3310894.XXX*

 

 

Lower Side Vent

3103649.XXX*

 

 

PowerVentAss’y

3108705.744**

*Replace “XXX” with the color code numbers. For color codes, contact your supplier.

**Alternate instructions forwarded with the Ventilator Kit.

For further information, contact your dealer or distributor.

--

Ventilation requirements

Ventilation heights

It is essential that all maximum or minimum dimensions are strictly maintained, as the performance of the refrigerator is dependent on adequate flow of air over the rear of the refrigerator.

Minimum ventilation heights

 

Roof vent and

A

Upper and lower B

 

lower side vent

 

side vent

 

 

inches

mm

 

inches

mm

RM2351

 

 

 

 

 

31

787

 

34

864

RM2354

 

 

 

 

 

 

 

 

 

 

 

RM2451

37-3/4

960

 

 

 

RM2454

 

 

 

 

 

 

 

 

 

 

 

RM2551

44-1/2

1130

 

 

 

RM2554

 

 

 

 

 

 

 

 

 

 

 

DM2652

57-3/4

1465

 

 

 

DM2662

 

 

 

 

 

DM2663

 

 

 

 

 

 

 

 

 

 

 

DM2852

63-3/4

1620

 

 

 

DM2862

 

 

 

 

 

DM3862

 

 

 

 

 

NDM1062

 

 

 

 

 

 

 

 

 

 

 

ndr1292

65

1651

 

 

 

 

 

 

 

 

 

Clearances

Minimum clearances (in inches) to combustible materials:

Top (G)

0

 

Side (K)

0

 

Bottom (L)

0

 

Rear (M1)

0

/ 1 (RM2351 & RM2354)

A

Minimum ventilation height

The uppervent should be centered overthe condenser coil at the back of the refrigerator.

Condenser

B

Minimum

Condenser

ventilation

height

 

 

'

+

+

,

1M: The distance between the rearmost part of the refrigerator and the wall behind it.

- -

-

-

General view. Features may vary according to model.

Dometic RM2354, DM2663, DM2652, RM2554, DM2862 INSTALLATION

Ventilation requirements

Overall and recess dimensions

Dimensions

 

Overall

 

 

Recess

 

 

 

 

 

 

 

Model

 

Height A

Width B

Depth C

Height H

Width W

Depth D

RM2351

inches

30-5/32

21-7/8

22-22/32

29-3/4

20-1/2

21-3/8

RM2354

mm

766

556

577

756

521

542

 

RM2451

inches

37-3/8

24-7/8

24-11/16

39-9/16

23-11/16

24

RM2454

mm

948

632

627

928

602

610

 

RM2551

inches

43-1/2

24-7/8

24-11/16

42-5/8

23-11/16

24

RM2554

mm

1104

632

627

1083

602

610

 

DM2652

inches

54-21/32

24-7/8

26-1/32

53-3/4

23-11/16

24

DM2662

mm

1388

632

661

1365

602

610

DM2663

DM2852

inches

60-51/64

24-7/8

26-1/32

59-15/16

23-11/16

24

DM2862

 

1544

632

661

1522

602

610

DM3862

mm

NDM1062

inches

60-54/64

24-7/8

26-5/8

59-15/16

23-11/16

24*

 

1544

632

676

1522

602

610*

 

mm

NDR1292

inches

59-31/32

33-11/16

26-21/32

59-1/16

32-3/4

24*

 

1523

855

677

1500

832

610*

 

mm

* Add 1" (25 mm) depth for units with one or two optional ventilator fans.

 

 

 

Side view

$

(

 

View from above

 

#

 

$

!

"

7

 

General view. Features may vary according to model.

--

Loading...