Bosch DKE 73, DKE 93 Operating And Installation Instructions

0 (0)
a
de Gebrauchs- und
Montageanleitung
en Operating and
installation instructions
fr Mode d’emploi et
notice de montage
montagevoorschrift
it Istruzioni d’uso
e per il montaggio
es Instrucciones de uso
y de montaje
pt Instruções de serviçio
e de montagem
sv Bruks- och
Monteringsanvisning
no Bruks- og
Monteringsanvisning
fi Käyttöo- ja
Asennusohje
da Brugs- og
montagevejledning
tr
Kullanma ve montaj k∂lavuzu
DKE 63 . . / DKE 73 . . / DKE 93 . .
Internet: http://www.bosch-hausgeraete.de Bosch Info-Team: de Tel. 01 80/5 30 40 50 (E 0,12/Min. DTAG)
2
mind.
650
mind.
550
de Seite 03–13
en page 14 – 24
fr page 25 – 35
nl pagina 36 – 46
it pagina 47 – 57
es página 58 – 68
Abb. 1
ELEKTRO ELECTR. ELETT. EL.
Abb. 1 GAS GAZ KAASU GASS
pt página 069 – 079
sv sid 080– 090
no side 091– 101
sivu 102 – 112
da side 113 – 123
tr Sayfa 124 – 134
14
Appliance description
Operating Instructions
Operating modes
Exhaust-air mode:
The extractor-hood fan extracts the kit-
chen vapours and conveys them through the grease filter into the atmosphere.
The grease filter absorbs the solid
particles in the kitchen vapours.
The kitchen is kept almost free of grease
and odours.
D
When the extractor hood is operated in exhaust-air mode simultaneously with a different burner which also makes use of the same chimney (such as gas, oil or
coal-fired heaters, continuous-flow heaters, hot-water boilers) care must be taken to
ensure that there is an adequate supply of fresh air which will be needed by the
burner for combustion. Safe operation is possible provided that the
underpressure in the room where the burner is installed does not exceed 4 Pa (0.04 mbar).
Lighting
Light / fan
switches
Filter grille
Chimney panelling
Operating modes
This can be achieved if combustion air can flow through non-lockable openings, e.g. in doors, windows and via the air­intake/exhaust-air wall box or by other technical measures, such as reciprocal interlocking, etc.
If the air intake is inadequate, there is a risk of poisoning from combustion gases which are drawn back into the room.
An air-intake/exhaust-air wall box by itself is no guarantee that the limiting value will not be exceeded.
Note: When assessing the overall requirement, the combined ventilation system for the entire household must be taken into consideration. This rule does not apply to the use of cooking appliances, such as hobs and ovens.
Unrestricted operation is possible if the extractor hood is used in recirculating mode – with activated carbon filter.
Circulating-air mode:
An activated carbon filter must be fitted
for this operating mode (see Filters and maintenance).
The complete installation set and
replacement filters can be obtained from specialist outlets.
The corresponding accessory numbers can be found at the end of these operating instructions.
The extractor-hood fan extracts the
kitchen vapours which are purified in the grease filter and activated carbon filter and then conveyed back into the kitchen.
The grease filter absorbs the grease
particles in the kitchen vapours.
The activated carbon filter binds the
odorous substances.
If no activated carbon filter is installed,
it is not possible to bind the odorous substances in the cooking vapours.
Before using for the first time
If you encounter a problem
If you have any questions or if a fault occurs, please call Customer Service.
(See list of Customer Service representatives).
When you call, please quote the following:
E-Nr. FD
Enter the relevant numbers into the box above. The E-Nr. (product no.) and FD (production date) are shown on the nameplate which can be seen inside the extractor hood after the filter frame has been detached.
Important notes:
The Instructions for Use apply to several
versions of this appliance. Accordingly, you may find descriptions of individual features that do not apply to your specific appliance.
This extractor hood complies with all
relevant safety regulations. Repairs should be carried out by
qualified technicians only.
Improper repairs may put the user at considerable risk.
Before using your appliance for the first
time, please read these Instructions for Use carefully. They contain important information concerning your personal safety as well as on use and care of the appliance.
Please retain the operating and
installation instructions for a subsequent owner.
Do not use the appliance if damaged.The appliance may be connected to the
mains by a qualified technician only.
The appliance is not intended for use by
young children or infirmed persons without supervision. Young children should be supervised to ensure they do not play with the appliance.
If the connecting cable for this
appliance is damaged, the cable must be replaced by the manufacturer or his customer service or a similarly qualified person in order to prevent serious injury to the user.
Dispose of packaging materials
properly (see Installation instructions).
This extractor hood is designed for
domestic use only.
Light bulbs must always be fitted when
the extractor hood is in use.
Defective bulbs should be replaced
immediately to prevent the remaining bulbs from overloading.
Never operate the extractor hood
without a grease filter.
Overheated fat or oil can easily catch fire.
If you are cooking with fat or oil, e.g. chips, etc., never leave the cooker unattended.
Do not flambé food directly under the
extractor hood.
Risk of grease filter catching fire due
! to flames.
The hotplates must always be covered
with a utensil.
Restrictions apply to the use of the
extractor hood over a solid-fuel burner (coal, wood, etc.). (See Installation instructions).
Gas hobs / Gas cookers
Do not use all the gas hotplates
simultaneously for a prolonged period (max. 15 minutes) at maximum thermal load, otherwise there is a risk of burns if the housing surfaces are touched or a risk of damage to the extractor hood. If the extractor hood is situated over a gas hob, operate the hood at maximum setting if three or more gas hotplates are operated simultaneously.
15
16
Operating procedure
Filters and maintenance
Grease filters:
Metal filters are used to trap the greasy element of the vapours that develop during cooking.
The filter mats are made from non­combustible metal.
Caution:
As the filter becomes more and more saturated with grease, not only does the risk of it catching fire increase but the efficiency of the extractor hood can also be adversely affected.
Important:
By cleaning the metal grease filters at appropriate intervals, the possibility of them catching fire as a result of a build-up of heat such as occurs when deep-fat frying or roasting is taking place, is reduced.
Cleaning the metal grease filters:
In normal operation (1 to 2 hours daily),
the metal grease filter must be cleaned after 8 to 10 weeks.
The filters can be cleaned in a dish-
washer. It is however possible that they will become slightly discoloured.
The filter must be placed loosely, and
NOT wedged, in the dishwasher.
Important:
Metal filters that are saturated with grease should not be washed together with other dishes etc.
When cleaning the filters by hand, soak
them in hot soapy water first of all. Then brush the filters clean, rinse them thoroughly and leave the water to drain off.
The most effective method of removing
vapours produced during cooking is to:
Switch the ventilator ON
as soon as you begin cooking.
Switch the ventilator OFF
a few minutes after you have finished cooking.
Switching ON:
Slide the right slide switch to the desired
fan setting.
Switching OFF:
Slide the right slide switch back to 0.
Lighting:
The light can be switched on at any
time, even though the fan is switched off.
1
2
3
Light Off/On
Ventilator settings